Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.2 L+₹1.9 L (5.32%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹39.4 L+₹3.1 L (8.58%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹39.4 L
EMD Value
₹50,000
Closing Date
4 Apr 2023, 3:00 pmClosed
Executive Engineer
P.H Division Kochi-16
AMRUT-2-Improving water supply at Kumaranasan Road of Kochi Corporation by laying distribution pipe PVC pipe from Kathrikadavu Bridge to STP Jn
2023_KWA_567054_1
WRD/KWA-CE(CR)/TR/1198/2022
Open Tender
Civil Works - Water Works
Item Rate
180 days
Kochi Coroporation
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
₹50,000
29 May 2023
16 Mar 2023
5 Apr 2023
16 Mar 2023
4 Apr 2023
16 Mar 2023
Amount
Working Charges
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.2:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m
100.98.1008:Engaging Coolie.
100.98.1009:Engaging Fitter ( grade 1).
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.
OD14796/2022-2023:Installation of 400 mm HDPE-PE100 8 Kg/cm2 Pipe by horizontal directional drilling method in all types of soil below Ground Level up to 1.50m to 2m depth for gravity sewer including preparing, and setting up the plant and equipment , installing new pipe work, testing and commissioning including cost of pipe (6 m line pipe with butt joint) all related civil/mechanical works like entry/exit pits as necessary. De watering, drilling, tringing, reaming, pulling back the new pipe on the designed alignment and monitoring by approved guidance system. Wastage of pipes, proper disposal of drilling fluid/bentonite slurry. Proper back filling of pit and holes by approved borrow material as per specification, approved method statement or as directed by Engineer in charge.
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.
OD11879/2022-2023:Interconnecting the newly laid 160mm PVC Pipe line to the existing 450mm CI Pipeline by using 450X100mm MS Clamp etc. supplied by the contractor and placing in position,jointing with solvent cement and testing to the required test pressure,including cost of saddle clamp,adapter,labour charges and hire for tools,etc..complete.
OD11905/2022-2023:Interconnecting newly layed 160mm pvc pipe with existing 160mm HDPE pipe using 160mm CIR Joint etc. supplied by the contractor and placing in position, jointing with solvent cement and testing to the required test pressure, including cost of all materials, labour charges and hire for tools etc. complete.
OD11416/2022-2023:Discarding Existing pipe lines 110/90/75/63/50mm Pvc pipe endcapped both ends using Proper End cap supplied by the contractor and placing in position,jointing with solvent cement and testing to the required test pressure,including cost of saddle clamp,adapter,labour charges and hire for tools,etc..complete.
OD11417/2022-2023:Shifting the public hydrants/ house connections with 20mm ASTM pipe and specials from the existing line to the newly laid pipes at different places
15.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
18.35.1:Constructing masonry chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
100.98.239:Supply of PVC Pipe, 10kg/cm2, 160mm Dia.
100.98.484:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm.
100.98.482:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm.
K K RAMESAN
SREEJITH T.M.
Bidder Name
K K RAMESAN
SREEJITH T.M.
udayakumar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_836639.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .