Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.7 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | 1 | Accepted-AOC LOWEST TENDERER | |
| 2 | 2₹17.2 L+₹2.5 L (16.6%)Rejected-AOC 107 2 AMPA MANOR IST FLOOR NELSON MANICKAM ROAD AMINJIKARAI CHENNAI 0 600 029 NO 107 2 AMPA MANOR 1ST FLOOR NELSON MANICKAM ROAD AMINIJIKARAI AMINJIKARAI | 2 | Rejected-AOC Awarded work for lowest tender. | |
| 3 | 3₹18.9 L+₹4.1 L (28.0%)Rejected-AOC | 3 | Rejected-AOC Awarded work for lowest tender. |
Tender Value
₹19.5 L
EMD Value
₹29,200
Closing Date
8 Jun 2022, 2:30 pmClosed
Registrar,KUHS
The Registrar KUHS, Medical college P O , 680596
Airconditioning of simulation lab rooms in the first floor of University admin building.
2022_KUHS_492610_1
19602/2020/A2/06/WORKS/KUHS
Open Tender
Electrical Works
Item Rate
60 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹3,087
₹29,200
Yes
6 Aug 2022
30 May 2022
10 Jun 2022
30 May 2022
8 Jun 2022
30 May 2022
30 May 2022 - 8 Jun 2022
Amount
16.3.9 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dai. (50mm thick expanded polysterene)
16.3.10 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 65mm dia.(50mm thick expanded polysterene)
16.3.11 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)
16.3.12 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 40mm dia. (50mm thick expanded polysterene)
16.3.13 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 32mm dia. (50mm thick expanded polysterene)
16.3.14 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.<br>Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 25mm dia. (50mm thick expanded polysterene)
od347838/2021_2022 Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.r|n<br>Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.<br>Chilled water piping of nominal size - 20mm dia. (50mm thick expanded polysterene)
od348012/2021_2022 Supply and installing at site UPVC pasted pipe using Solvent cement ISI Marked( As per IS 4985) with ISI marked PVC fittings like tees, elbows, bends, Ys etc.Adapters,clamping with GI U clamps as required for firmly installing pipes.Testing of the entire system for leakage and air tightness. insulation of the Piping System using 9mm thick Nitrile rubber.Through Utrap and maintaining a slope of 1:100.SIZE 25MM OD
od341119/2021_2022 supply Installation testing and commissioning of 5 star inverter 1.5 ton split ac with indoor,outdoor unit,copper pipe and all the necessary fittings.
od348232/2021_2022 Supply, installation, testing and commissioning of 4Way, 1.5 Tr Ceiling suspended Cassette type fan coil unit complete with three row chilled water copper tube aluminium finned coil, quiet high efficiency centrifugal fan with permanently lubricated fractional horse power motor, easily cleanable synthetic filter, sandwich insulated drain tray, two way valve with actuator, Ball valve set with Flare Nut and all other required fittings and cordless remote for the operation of the fan. Attractive grill as integral part of the unit. Provision for the fresh air intake. The unit shall be suitable for operation on Single phase 230 volts 50- cycles, the fan shall have three speeds. Make: Midea/Carrier/Equivalent
od348234/2021_2022 Supply, installation, testing and commissioning of 4Way, 2 Tr Ceiling suspended Cassette type fan coil unit complete with three row chilled water copper tube aluminium finned coil, quiet high efficiency centrifugal fan with permanently lubricated fractional horse power motor, easily cleanable synthetic filter, sandwich insulated drain tray, two way valve with actuator, Ball valve set with Flare Nut and all other required fittings and cordless remote for the operation of the fan. Attractive grill as integral part of the unit. Provision for the fresh air intake. The unit shall be suitable for operation on Single phase 230 volts 50- cycles, the fan shall have three speeds. Make: Midea/Carrier/Equivalent
od348235/2021_2022 Supply, installation, testing and commissioning of 4Way, 2.5 Tr Ceiling suspended Cassette type fan coil unit complete with three row chilled water copper tube aluminium finned coil, quiet high efficiency centrifugal fan with permanently lubricated fractional horse power motor, easily cleanable synthetic filter, sandwich insulated drain tray, two way valve with actuator, Ball valve set with Flare Nut and all other required fittings and cordless remote for the operation of the fan. Attractive grill as integral part of the unit. Provision for the fresh air intake. The unit shall be suitable for operation on Single phase 230 volts 50- cycles, the fan shall have three speeds. Make: Midea/Carrier/Equivalent
16.7.1.5 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 80 mm
TOOT MNE TECH PVT LTD
INTIMATE REFRIGERATION AND AIR CONDITIONS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_707306.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .