Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L1 | Accepted-AOC L1 bidder accepted after deducting schedule of credit amount | |
| 2 | L2₹24.2 L+₹1.3 L (5.68%)Rejected-Finance 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹27.3 L+₹4.4 L (19.2%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹28.7 L+₹5.8 L (25.3%)Rejected-Finance 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹28.9 L+₹6.0 L (26.0%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Mar 2024, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2024_MES_643851_1
GE MAINT EZHIMALA 8624
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
Yes
24 Apr 2024
23 Feb 2024
22 Mar 2024
23 Feb 2024
20 Mar 2024
8 Mar 2024
24 Feb 2024 - 2 Mar 2024
Amount
Notes for all items of BOQ:- a) Contractor has to provide one electrician and one helper each day including sunday and holidays to collect complaints from complaint cell/ JE E/M/ AGE E/M and rectify the same within 48hrs(two days) otherwise recovery will be done at Rs. 1000 per complaint per day delay. b) Contractor has to maintain complaint slip/ register and record day to day complaints and after rectification has to get signature of user/JE E/M on daily basis. c) contractor has to provide necessary safety equipments and will be fully responsible for any incidents occuring on site. d) Contractor has to visit the site before quoting the tender. e) Contractor has to provide proper ladder arrangement to work on any height of street light pole. f) If contractor failed to provide electrician to attend complaint or absent to attend complaints then recovery will be done at Rs. 2000 per day.
M&L for taking down the unserviceable LT UG cable of size 6 sqmm to 35 sqmm 4 core including removing electrical connection, keeping side serviceable cable, including removing cable protection cover etc complete all as specified and as directed.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed by Engr-in-charge. Notes:- a) For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification. b)The excavation has to be done manually only.
Returning and filling in including levelling, watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and directed by Engr-in-charge.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and directed by Engr-in-charge.
Supply and spreading riddled earth for cushioning and covering of the UG cable in trenches complete all as specified and as directed. Note:- Punned thickness shall be measured for payment purpose.
Supply and lay PCC un reinforced LT cable cover of size 250mmx 150mmx40mm, class LV type I flat for cable protection complete all as specified and as directed.
Relaying of PCC un reinforced LTcable cover of size 250mmx150 mmx40mm, item obtained from ser No 02 above complete all as specified and directed by Engr in charge.
Relaying cable XLPE insulated heavy duty galvanised steel strip armoured LT 1100 volt grade with aluminium conductors multistranded confirming to IS laid in trenches/pipes/wall of size upto 35 sqmm 4 core complete all as specified and as directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 16 sqmm 4 core complete all as specified and as directed.
All as per item No.10 above but size of 10 sqmm 4 core complete all as specified and as directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated armoured cable with copper conductors of size 2.5 sqmm 4 core complete all as specified and as directed.
M&L for mass filling in foundation/coping/wall with PCC 1:3:6 using 20 mm graded aggregate type C1 as per site requirement complete all as specified and as directed by Engr in charge.
M&L for dismantling/removal of existing pole of post top lantern of any type from it's position/foundation after necessary excavation and earth work and refixing on site complete all as specified and as directed.
M&L for cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 mtr and depth 0.7 mtr all as directed and making good the road/hard using pre mix bituminous as required at site to match with the existing surface complete all as specified and as directed. Note:- Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge.
S&F in replacement of GI tubing light grade 50 mm nominal dia in trench/road/pole for cable protection complete all as specified and as directed.
All as per item No.16 above but size of 40mm nominal dia complete all as specified and as directed.
S&F in replacement of copper cable flexible 1.5 sqmm 3 core 230 Volts complete all as specified and as directed by Engr-in-charge.
S&F in replacement of digital time switch programmable type, two module complete all as specified and directed by Engr in charge. Make:- Model No: 67DDT0 of L&T or equivalent in Havells/ Schneider/Seimens.
S&F in replacement of contactor four pole 415 volt 63 Amp capacity complete all as specified and directed by Engr in charge. Make:- Type: MCX 12 of L&T or equivalent in Havells/ Schneider/ Seimens.
S&F in replacement of post top lantern having opal acrylic and spun aluminium reflector with high power LEDs as light source having 40 watt capacity , 440V, 50Hz, IP 65 rated ,with 5Kv SPD included and PF above 0.95 suitable for pole dia upto 60 mm complete all as specified and directed by Engr in charge. Make:- Model No. CBP -610 - 40-57-SL-CA-NBK of Crompton/ BGCTNP 40W LED WH/WW of BAJAJ / SLE PT 40W ETPP of SURYA/ RUBYPT40WLED 757 PSYMTOPC of Havells. Note:- LM79 report by NABL accredited lab has to be submitted.
S&F in replacement of bollard light fitting tulip/robust type LED bollard light fitting made out of die cast aluminium with soft 360 light ouput and 10/9W capacity, CCT 3000k/5700k with IP 65 proctection complete all as specified and as directed by Engr-in-charge. Make:- Cat part no.LBLTW-10-WW of Crompton/BGBOM 605 9W of Bajaj/ TURINBLS10WLED830PSYMTOPC of Havells/SLE BL 10W-FLR650NX OF SURYA. Note:- LM79 report by NABL accredited lab has to be submitted.
S&F in replacement of old unserviceable street light fitting with LED street light fittings on poles of any height upto 11m using proper ladder arrangements. LED street light luminaire must have following specifications: minimum 60 watts capacity, 240V, 50Hz made out of pressure die cast housing, IP 66 rating, efficacy above 120 Lm/W, 10kv surge protection 5700K complete all as specified and as directed. Make:- Model No. TRP-409-60-57-SL-GL-NSG of Crompton / ENXT P 72L WH CR PC SD of BAJAJ / SLE UL 60W IP66 LXN of SURYA. Note:- Necessary fixtures needed to fix the street light fitting in pole of any dia has to be included in the quoted rate. LM79 report by NABL accredited lab has to be submitted.
S&F in replacement of old unserviceable street light fitting with LED street light fittings on poles of any height upto 11m using proper ladder arrangements. LED street light Luminaire must have following specifications: minimum 45 watts capacity, 240V, 50Hz made out of pressure die cast hosuing, IP 66 rating, efficacy above 120 Lm/W, 10kv surge protection 5700K complete all as specified and as directed. Make:- Model No. TRP-409-45-57-SL-GL-NSG of Crompton / ENXT P 54L WH CR PC SD of BAJAJ / SLE UL 45W IP66 LXN of SURYA. Note:- Necessary fixtures needed to fix the street light fitting in pole of any dia has to be included in the quoted rate. LM79 report by NABL accredited lab has to be submitted.
S&F in replacement of post top lantern, made of spun aluminium die cast material, energy saving, enviormental friendly, with high power LEDs as light source of 20/25 watt capacity warm white/ CDL, IP 65 rated protection suitable for pole dia of upto 60 mm complete all as specified and directed by Engr in charge. Make:- Model No.CBP-610-25-57-SL-CA-NBK of Crompton/ BGCTNP 20W LED WH/WW of BAJAJ / RUBYPT25WLED830SSYMTOPC of HAVELLS.
S&F in replacement of die cast aluminium IP 66 rated 100 W LED flood light luminaire on poles / buildings of any height using proper ladder arrangements with system efficacy above 120Lm/W and with 10KV surge protection device complete all as specified and directed by Engr in charge. Make:- Model No. GLATT MT 120L WH PO PC SD of BAJAJ / SLE UL 100W IP66 LMS NEO of SURYA/TFS-504-100-57-60D-SL-GL-NSG of Crompton / JETAADORNFLS100WLED757SSYMTOTG of Havells.
S&F in replacement of die cast aluminium IP 66 rated 80 W LED flood light luminaire on poles/ buildings of any height using proper ladder arrangements with system efficacy above 120Lm/W and with 10KV surge protection device complete all as specified and directed by Engr in charge. Make:- Model No. GLATT MT 96L WH PO PC SD of BAJAJ / SLE UL 80W IP66 LMS NEO of SURYA/TFS-504-80-57-80D-SL-GL-NSG of Crompton/ JETAAD ORNFLS80WLED757SSYMTOTG of Havells.
S&F in replacement of bracket made out of GI pipe medium grade, 50 mm dia, 90 cm long for fixing street light with and including clamps, nuts, bolts, washer etc complete accessories and applying two coats of oil painting over one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for taking down the defective security light fittings /street light fittings of any type from 11/10/8.5 mtr swan neck type pole and refixing in same position after carrying out necessary repair work/replacement of burn out parts and cleaning the fittings completely including replacement of minor burn out spares such as connectors/clamps/wire etc complete all as specified and directed by Engr-in-charge.
S&F in replacement of weather proof street light junction boxes made out of thermo plastic consisting of 4 nos of connectors of capacity 40 amp 415v and 1no of SP MCB rating 6 AMP 240 V with proper closing arrangement, elmax connector for neutral link including pole mounting clamp with nuts, bolts etc. The size of the box shall be minimum of size 205mmx255mmx112 mm. The box should have two cable entry complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of LED bulb B22 type 09 Watts in garden lights/ dome lights after removing the outer cover and refixing the same after replacement complete all as specified and directed by Engineer-in-Charge. Make:- Crompton/Bajaj/Havells/Philips/Surya
M&L for scrapping out faded / rusted old paint from street light pole of height upto 11m using wire brush, emery paper, preparing surface for painting, applying one coat of aluminium paint on poles including cross arms, bolts and nuts, anti climbing device etc and writting existing pole number with black paint over a yellow base and painting of coping/base using white cement paint complete all as specified and directed by Engineer-in-Charge.
M&L for scrapping out faded / rusted old paint from decorative PTL double arm/ single arm pole of height upto 3.5m using wire brush, emery paper, preparing surface for painting, applying one coat of aluminium paint on poles including cross arms, bolts and nuts etc and writing existing pole number with black paint over a yellow base and painting of coping/base using white cement paint complete all as specified and directed by Engineer-in-Charge.
M&L for welding of double arm decorative poles at joints by removing rusts from existing poles, patching of holes and making the surface even and jointing the arms using necessary fixtures or by using welding or bolts and nuts complete all as specified and directed by Engineer-in-Charge.
M&L for repairing of garden lights by removing defective garden light fitting and refixing the same after doing minor repairs such as cleaning, tightening loose connections, re aligning and replacing burnout lamp holder /connectors complete all as specified and directed by Engr-in-charge.
S&F in replacement of post top lantern, suspended type,energy saving, enviormental friendly, with high power LEDs as light source of 60/70 watt capacity warm white/CDL, IP 65 rated protection suitable for pole dia of upto 60 mm complete all as specified and directed by Engr in charge. Make:- Model No.SLE PT 60W tm VEGA of Surya/ BLS BOR 60W WW CL TM of BAJAJ / EROSPT72WLED730PSYMTOPC of HAVELLS.
Benchmark Engineers and Contractors
Gates Infra Construction Co
ROTECH ENGINEERS AND BUILDERS
SREEKRUPA ENTERPRISES
RASNA ENTERPRISES
TAMS ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .