Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L1 | Accepted-AOC Accepted Contract being lowest | |
| 2 | L2₹14.1 L+₹1.2 L (9.30%)Rejected-AOC FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L2 | Rejected-AOC Rejected not being lowest | |
| 3 | L3₹14.9 L+₹2.0 L (15.5%)Rejected-AOC 121004 | L3 | Rejected-AOC Rejected not being lowest | |
| 4 | L4₹21.8 L+₹8.9 L (69.2%)Rejected-AOC 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L4 | Rejected-AOC Rejected not being lowest |
| Sl No | Description | Qty | Unit | SMEC Automation Pvt Ltd L4 | Neptune Engineers and Builders L3 | Bob Enterprises L2 | Green Ray Enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00Notes:- (i) The contractor can visit the site before quoting the tender. (ii) The contractor has to keep ready all the spare parts at main pump house for rectification of faults within no time. (iii) All minor breakdowns should be attended within 2 hrs and report to JE/AGE E/M or else Rs 2000/hr will be recovered from payments. | |||||||
| 1.01 | Comprehensive maintenance of water supply SCADA system including outsourcing of M&O services by employing 01 Nos Skilled Technician /shift of 8hrs in three shifts (Ist shift : 0600 hrs to 1400 hrs, IInd shift : 1400 hrs to 2200 hrs, IIIrd shift : 2200 hrs to 0600 hrs) with necessary reliever. (a) Maintenance / functionality checking of components of PLC based control panels including all accessories modem, antenna etc. installed at various pump houses, sumps and master control station.
The duties of staff are :-
(i) Manual/ Remote operations from the Control panels installed at various pump houses.
(ii) Monitoring of water receiving from KWA/Water distribution through SCADA system and should liase with KWA staff if required as directed by JE/AGE E/M.
(iii) Daily checking of chlorine, TDS, pH quality of KWA water received and report to JE/AGE E/M.
(iv) Adding of chlorine manually in case of absence of chlorine content in KWA water.
(v) To liase with sub stn 18 for DG supply in case of power failure.
(vi) Monitoring of pumps/LT panels/valves operation installed at main pump house and report to JE/AGE E/M accordingly. Changing of pumps to be operated manually as specified by JE/AGE E/M.
(vii) Opening main distribution valves manually incase of communication error / supply failures as directed by JE/AGE. | 11 | Per Month | 1,50,000 ₹16,50,000 | 90,000 ₹9,90,000 | 93,000 ₹10,23,000 | 89,700 ₹9,86,700 Lowest |
| 1.02The SCADA equipment’s installed at various pump houses are:- RL-30 pump house a) SCADA control panel. b) 100 HP pump sets with soft starters - 02 Nos. c) Main LT panel and sub LT Panel. d) SCADA operated valves - 03 Nos (Make : Marsh/Rite tork) e) ULS f) 1 kVA UPS g) Wireless modem, Make :Mcom Technology (Model: MCOM400TIRTU) RL-92 pump house : a) SCADA control panel b) SCADA operated valves - 02 Nos (Make : Marsh/Rite tork) c) ULS d) 1 kVA UPS e) Wireless modem, Make :Mcom Technology (Model: MCOM400TIRTU) RL-127 pump house : a) SCADA control panel. b) Main LT panel and sub LT panel. c) SCADA operated valves - 05 Nos (Make : Marsh/Rite tork) d) ULS e) 1 kVA UPS f) Wireless modem, Make :Mcom Technology (Model: MCOM400TIRTU) | |||||||
| 1.03The SCADA eqipments installed at various pump houses as under:-RL-146 pump house : a) SCADA control panel b) Main LT panel and sub LT panel c) SCADA operated valves - 03 Nos (Make : Marsh/Rite tork) d) ULS e) 1 kVA UPS f) Wireless modem, Make :Mcom Technology (Model: MCOM400TIRTU) RL-197 pump house : a) SCADA control panel b) Main LT panel and sub LT panel c) SCADA operated valves - 01 Nos (Make : Marsh) d) ULS make : Banner (Cat No. QT 50 ULB) e) 1 kVA UPS f) Wireless modem, Make :Mcom Technology (Model: MCOM400TIRTU) MIMIC panel : a) PLC make: Mitsubishi (Cat No.FX5U-80M) b) HMI make : Mitsubishi (Cat No.GS2107-WTBD-N) The SCADA control panel is having main components as : a) PLC make: Mitsubishi (Cat No.FX5U-80M) b) HMI make : Mitsubishi (Cat No.GS2107-WTBD-N) c) relays make : IDEC (Part No. RU4S-A220/Part No. RU4S-D24) d) SMPS make : NHP (cat No.NHP-ES-125-1-24) | |||||||
| 2.00Notes:- (i) The quoted rate is inclusive of charges for static IP, SIM communication cost and stationary required to note daily water reports / testing parameters. (ii)The contractor has to carryout minor changes in SCADA software/PLC programme as directed by Engr-In-Charge without extra cost. (iii) If contractor failed to provide the High-Skilled technician in shift wise for three shifts on daily basis as per labour law (including sundays and holidays) then a recovery of 2000/- per shift will be levied. (iv)The contractor has to follow labour laws and pay wages not less than the minimum fair wages subscriber EPF, ESI contribution and pay bonus as applicable and has to provide uniform, tools etc. (v) All spare parts will be measured and paid separtely as Supply and fix. | |||||||
| 3.00 | Supply and fix in repair/replacement of voltage sensing phase failure relay (Auto / Manual / Remote Reset Adj. Unbalance, 2 CO Contact,) suitable to fit in existing PLC panels complete all as specified and directed. Model : VSP D2 Make: - Minilec/L&T/Siemens or equivalent | 2 | Each | 3,000 ₹6,000 | 4,500 ₹9,000 | 2,000 ₹4,000 Lowest | 3,112 ₹6,224 |
| 4.00 | Supply and fix in repair/replacement of Relay with base - 4 C/O, 240V DC complete all as specified and directed. Make : IDEC (Part No. RU4S-A220)/ Omron (cat No. MY4N 220/240ACS) /Salzer (Cat No. MSP4P240A) | 10 | Each | 1,000 ₹10,000 Lowest | 1,000 ₹10,000 Lowest | 1,200 ₹12,000 | 1,200 ₹12,000 |
| 5.00 | Supply and fix in repair/replacement of Relay with base - 4 C/O, 24V DC complete all as specified and directed. Make : IDEC (Part No. RU4S-D24)/ Omron (cat No. MY4N DC24) /Salzer (Cat No. MSP4P24) | 10 | Each | 1,000 ₹10,000 | 800 ₹8,000 Lowest | 1,200 ₹12,000 | 1,200 ₹12,000 |
| 6.00 | Supply and fix in repair/replacement of LED Indicators of Colour : Red / Yellow /Blue complete all as specified and directed. Make : Schneider (Part No.XB7EV04MPN/XB7EV05MPN/XB7EV06MPN) or equivalent in ESBEE (L&T) (Cat No. EPLR240A/EPLY240A/EPLB240A) /TEKNIC (cat No.P2PLBR4L230VAC/ P2PLBR8L230VAC/ P2PLBR6L230VAC) | 6 | Each | 600 ₹3,600 | 350 ₹2,100 | 400 ₹2,400 | 250 ₹1,500 Lowest |
| 7.00 | Supply and fix in repair/replacement of Push Button with LED Indicator 240V A.C, Colour : Red/ Yellow/Green complete all as specified and directed Make : Schneider (Part No. XB5AW34M2N/XB5AW35M1N/XB5AW33M1N) or equivalent in ESBEE (L&T) (cat No. EG03FDLR240A/EG03FDLY240A/EG03FDLG240A)/ TEKNIC (cat No. P2ALRF4L230VAC/P2ALRF8L230VAC/P2ALRF3L230VAC) | 6 | Each | 1,200 ₹7,200 | 150 ₹900 Lowest | 500 ₹3,000 | 200 ₹1,200 |
Tender Value
₹15.7 L
EMD Value
₹31,360
Closing Date
23 Oct 2025, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2025_MES_732533_1
GE MAINT EZHIMALA 8774
Open Tender
Civil Works
Item Rate
330 days
Ezhimala
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMAL
₹31,360
Yes
11 Nov 2025
24 Sept 2025
29 Oct 2025
24 Sept 2025
23 Oct 2025
9 Oct 2025
24 Sept 2025 - 1 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
Tender.pdf
Tender Documents • 0.27 MB
BOQ_820183.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .