| Sl No | Description | Qty | Unit | EDISON ELECTRICAL ENGINEERING L2 | JAHFAR L1 |
|---|---|---|---|---|---|
| 1.00Electrical | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 19 | point | 1,551.58 ₹29,480.02 | 1,450 ₹27,550 |
| 1.00 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 60 | metre | 246.52 ₹14,791.20 | 240 ₹14,400 |
| 1.00 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 25 | metre | 291.09 ₹7,277.25 | 250 ₹6,250 |
| 1.00 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 25 | metre | 353.5 ₹8,837.50 | 330 ₹8,250 |
| 1.00 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 25 | metre | 100.61 ₹2,515.25 | 65 ₹1,625 |
| 1.01 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 8 | metre | 145.18 ₹1,161.44 | 145.18 ₹1,161.44 |
| 1.01 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 4 | each | 504.55 ₹2,018.20 | 500 ₹2,000 |
| 1.01 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). | 1 | each | 718.91 ₹718.91 | 650 ₹650 |
| 1.01 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator | 1 | each | 567.37 ₹567.37 | 567.37 ₹567.37 |
Tender Value
₹2.4 L
EMD Value
₹5,957
Closing Date
24 Sept 2025, 9:00 amClosed
ASSISTANT ENGINEER
MALAPPURAM MUNICIPALITY
Annual Plan-Electrification and Providing Pumpset at Peruparamba Chungam Center No 107 Anganwadi - Malappuram Municipality-Proj No S1230/25-General Electrical Work
2025_LSGD_798170_25
AE/LID-EW/MLPM/06/2025-26
Open Tender
Electrical Works
MALAPPURAM
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹5,957
Yes
28 Mar 2026
18 Sept 2025
25 Sept 2025
18 Sept 2025
24 Sept 2025
18 Sept 2025
Amount
Electrical
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD267303/2025-2026:Supply and fixing of 9W LED Bulb, as required
OD267304/2025-2026:Supply, installation testing and commissioning exhaust fan of size 150mm sweep Light duty in plastic body with self opening lowers in the existing opening, fixing necessary anchor bolts/bolt and nut with 0.3m,110mm PVC pipe neatly plastered in the existing exhaust fan hole, making good the damages, color washing etc as required and giving connection with required length of 24/0.20mm PVC insulted and PVC Sheathed 650/1100V grade 3 core round copper conductor flexible wire
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
2.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
OD267308/2025-2026:Supply and installation of dust and Vermi proof, single phase Syntex meter board (GS-MB-3525) [350 x 250 x 150] and to fix KSEB meters, fuse Unit, CT, RCCB etc as required including fixing it on wall, making good the damages, color washing etc as required.
OD267302/2025-2026:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
OD267305/2025-2026:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
OD267301/2025-2026:Supply, providing and fixing 2 x 25 x 3mm GI strip test joint and providing 25x6mm brass nut and bolt etc. and connection as required for earthing system
OD267309/2025-2026:Supply, providing and fixing 25 x 3mm GI Strip earth lead from the test joint to earth plate
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD267306/2025-2026:Charges for preparation of KSEB or KSELB test Report, drawings and other related documents etc as required by the contractor as per the instruction from the Assistant Engineer and submit it to the concerned KSEB section office or KSELB including application fee. Copy of application fee and related documents are to be submitted to the concerned Assistant Engineer.
OD267310/2025-2026:Supply and installation testing and commissioning of 2HP 20 Stage Borwell submersible motor pump set having 2850 RPM suitable for single phase 230/240V, 50 Hz, AC supply conforms to relevant ISS. Head 34 to 120m with a flow rate of 1.5 -0.55 LPS and should provide 1.2LPS at a head of 90m with standard size delivery pipe connected to the motor using leakproof materials as required including giving connection to the existing pipe as per the direction of the engineer. (Kirloskar/Texmo/Crompton or equivalent)
90.14.28.13:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 2 HP submersible motor pumps (DOL)
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD267311/2025-2026:Supply and providing 50 mm dia Full way valve (ISI)
OD267312/2025-2026:Supply threading, laying and joining of 50 mm Submersible Column/HDPE Pipe for submersible pump, approved make specials as delivery pipe using required leak proofing materials etc. as required.
OD267313/2025-2026:Supply and providing 50 mm dia Gun Metal Non return valve (ISI)
OD267314/2025-2026:Supply and providing 50 mm dia Flange set
OD267315/2025-2026:Supply and laying of 20mm or nearest size Nylon rope
OD267316/2025-2026:Supply and providing 50 mm stainless steel Hose Collar with hose clip
OD267317/2025-2026:Supply and fixing flat iron clamps made from 2 nos. 50x6 mm flat iron clamp of 50 mm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
OD267318/2025-2026:Supply, Fixing, Installation and Commissioning of 32 Inch, LED Google TV. (Sony/Haier) with superior quality Stabilizer(V-Guard or Equivalent)
EDISON ELECTRICAL ENGINEERING (BID ID -2354548)