GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
Re-wiring of internal electrification and allied accessories, at OMQ, SMQ and repair and maint of internal electrification at GE (AF) No 02 Jodhpur
2024_MES_647793_1
8442/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) No 02 Jodhpur
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) No 02 Jodhpur
₹1 L
Yes
30 May 2024
23 Mar 2024
17 Apr 2024
23 Mar 2024
15 Apr 2024
7 Apr 2024
1 Apr 2024 - 6 Apr 2024
Amount
Taking down old unserviceable sub-main wiring aluminium/copper from surface/concealed conduits after necessary disconnection of electrical connection, making good to damaged surface of wall to match with existing surface with smooth finish complete all as directed and specified.
M&L for cutting upto a depth of 2.5 cm into brick/concrete/stone masonry walls, with or without reinforcement and trimming surface as required, for concealing PVC conduit 20/25mm dia and plastering in 1:4CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed by engr-in-charge.
M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulated flexible multi-stranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unserviceable sub-main wiring complete all as specified for following sizes of wires :-.
Two runs of 2.5 Sq.mm main cable alongwith one run of single core 2.5 Sq.mm for continuous earth wire
Two runs of 4.0 Sq.mm main cable alongwith one run of single core 4.0 Sq.mm for continuous earth wire
Two runs of 6.0 Sq.mm main cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire
Two runs of 10.0 Sq.mm main cable alongwith one run of single core 10.0 Sq.mm for continuous earth wire
M&L for Sub main wiring with four runs of 10.0 Sq.mm main cable alongwith two run of single core 10.0 Sq.mm for continuous earth wire (with approved colour coding as per IS), single core FRLS PVC insulated flexible multi-stranded copper conductor 1.1 KV grade drawn through & including 32mm PVC grey conduit heavy duty with necessary accessories (like bend, junction boxes etc.,) including taking down old unserviceable sub-main wiring complete all as specified. (Note : GI saddle shall be used to fix PVC conduit and distance between two saddle shall not be exceed 1.2 mtr)
Labour only for disconnecting all electrical connection of Mains TPN DB in meter box, disconnecting the removing energy metes from meter box and stacking at site for re-use of serviceable meters, removing old rusted/damaged MS iron meter/DB box fixed flush (semi-concealed) to wall surface, making good to damaged surface of wall with kiln burnt subclass-B brick work and plastering with CM 1:4 for smooth finish, white washing the repaired surface after drying all as directed and specified. (Note : Necessary curing shall be carried out by contractor for repaired portion of walls)
Supply, installations, testing and commissioning CPRI approved factory made indoor cubical type panel box for fixing energy meter, 6 each separate compartment for each energy meter, fabricated using 2.0mm thick MS sheet, duly provided with 8 mm thick flame proof backelite/hylem sheet for mounting Energy meters in each compartment, and provision pre-wiring and fixing of incoming and outgoing control MCCB/MCBs, each meter compartment shall provide with front opening hinged door with internal or external locking arrangement. MS box duly painted with two coats of powder coated Semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 160 Amps, 4 pole as incomer and vertical or horizontal copper busbar chamber for taking connection to incomer MCB of each meter by using 10 Sqmm, PVC insulated multi-stranded copper conduction wire single core in proper colour codes all as specified to accommodate as under :-(a) MCCB 160 Ams, 4 pole, 16 kA, (Ics=100 % of Icu) - as incommer(b) Copper Busbar 200 Amps duly sleev insulated for set of 3 phase, 4 wire system - 01 Set(c) 2 runs of PVC insulated single core multistraded FRLS grade copper wire for connection from busbar to input supply of Each energy meter by using necessary copper alloy lugs/thimbles.(d) MCB SPN 63 Amps on each meter incomming pre-wired - 6 Nos (Two outgoing on each meter)(e) MCB SPN 40 Amps on each meter outgoing pre-wired - 12 Nos (Two outgoing on each meter)(f) LED Indicator lamp (R,Y,B) - Set of Three. Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter panel on wall surface and re-fixing energy meter inside panel, making all incoming and outgoing electrical connections with existing input cable and outgoing wires.
Supply, installations, testing and commissioning CPRI approved factory made indoor cubical type panel box for fixing energy meter, 4 each separate compartment for each energy meter, fabricated using 2.0mm thick MS sheet, duly provided with 8 mm thick flame proof backelite/hylem sheet for mounting Energy meters in each compartment, and provision pre-wiring and fixing of incoming and outgoing control MCCB/MCBs, each meter compartment shall provide with front opening hinged door with internal or external locking arrangement. MS box duly painted with two coats of powder coated Semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 100 Amps 4 pole as incomer and vertical or horizontal copper busbar chamber for taking connection to incomer MCB of each meter by using 10 Sqmm, PVC insulated multi-stranded copper conduction wire single core in proper color codes all as specified to accommodate as under :-(a) MCCB 100 Ams, 4 pole, 16 kA, (Ics=100 % of Icu) - as incomer (b) Copper Busbar 200 Amps duly sleev insulated for set of 3 phase, 4 wire system - 01 Set(c) 2 runs of PVC insulated single core multi-standrded FRLS grade copper wire for connection from busbar to input supply of Each energy meter by using necessary copper alloy lugs/thimbles.(d) MCB SPN 63 Amps on each meter incoming pre-wired - 4 Nos (Two outgoing on each meter) (e) MCB SPN 40 Amps on each meter outgoing pre-wired - 8 Nos (Two outgoing on each meter) (f) LED Indicator lamp (R,Y,B) - Set of Three. Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter panel on wall surface and re-fixing energy meter inside panel and making all incomming and outgoing electrical connections with existing input cable and outgoing wires.
Taking down carefully MCBs and DBs TPN/SPN by disconnecting electrical connections and stacking at site for re-use after repairs or shifting unserviceable DBs/MCBs to store for taking credit, making good to damaged surface to match with existing specification all as specified and directed.
S&F Sheet metal enclosure distribution board TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, 200 Amps rated neutral copper bus bar for housing MCBs and including provision for fixing TPN MCB as incomer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification complete including taking out old all as specified all as specified and directed. Note : MCB SP/SPN/TPN will measured and paid separately under relevant item.
S&F sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified & directed.
S&F sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as specified & directed.
S&F MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F MCB SPN 32Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F in repair surface mounted 2' x 2' LED luminaire 36 watt, cool day/warm white light with white powder coated CRCA housing with LED driver, efficiency >100 Lm/w complete all as specified and directed. Make –Crompton or equivalent make mention in Appendix ‘B’.
S&F in repair round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light (Day cool/warm light) complete with drivers, holders, LED lamp suitable for roof ceiling (cut out size 80mm and surface dia 115mm approx.) including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. Make : Havells cat ref No LHEBADP7IZ1W006 or equivalent make mentioned in Appendix ‘B’. Note : Cutting and provn of light fitting is included in the quoted rates
S&F in repair round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light (Day cool/warm light) complete with drivers, holders, LED lamp suitable for roof ceiling (cut out size 120mm and surface dia 115mm approx.) including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. Make : Havells cat ref No LHEBADP7IZ1W006 or equivalent make mentioned in Appendix ‘B’. Note : Cutting and provn of light fitting is included in the quoted rates
S&F in repair round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light (Day cool/warm light) complete with drivers, holders, LED lamp suitable for roof ceiling (cut out size 80mm and surface dia 115mm approx.) including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. Make : Havells cat ref No LHEBADP7IZ1W006 or equivalent make mentioned in Appendix ‘B’. Note : Cutting and provn of light fitting is included in the quoted rates.
S&F in repair LED light fittings, 10 W bulk head luminaries 230V, 50 Hz complete with all accessories and including connecting up with three core copper conductor cable with suitable size complete all as specified and directed. Make: Havells/Crompton/Philips
S&F in repair LED mirror light fitting, 10 watt, 600 mm length complete with all accessories pre-wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. Make: Havells/Crompton/Philips
Taking down carefully copper/aluminium point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multi-stranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly, drawn in and including PVC Casing and Capping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : -
One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator.
One light point controlled by two No’s 5 Amps switch two way
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independent board.
One bell point controlled by one switch 5 Amps bell push.
All same as per BOQ item No 22.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independent board.
All same as per BOQ item No 22.00 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, FRLSH, single core, PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green colour) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers.
S&F Switch piano, flush type, single pole, one way, 6 Amp.
S&F Switch piano, flush type, single pole, one way, 16 Amp.
S&F Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
S&F Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
S&F (in repairs) Ceiling rose surface bakelite 65x50mm three terminal.
S&F(in repairs) Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or square box using necessary screw & gutti complete all as specified.
S&F Stepped type electronic fan regulator, switch size, flush type 230V AC.
S&F electronic Bell Bulbul music, 230 volt, single phase.
S&F bell push, type, 6 Amps, 2 Module
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F switch modular single pole one way 16 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Socket modular 6&16 Amp 2/3 pin combined two module.
S&F electronic fan regulator modular stepped type 120 watt, two module.
S&F modular white or Ivory cover plate with frame 1 module
S&F modular white or Ivory cover plate with frame 2 module
S&F modular white or Ivory cover plate with frame 3 module
S&F modular white or Ivory cover plate with frame 4 module
S&F modular white or Ivory cover plate with frame 6 module
S&F modular white or Ivory cover plate with frame 8 module
S&F Wall Mounted decorative luminaire fitting suitable for LED lamp B-22 Base 9 watt light fitting including in build LED light driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6/8 inch x 10 inch MS box and brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper multi-stranded cable all as directed at site by Engineer-in-charge. Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items.
All as per BOQ item No 46.00 here-in-before but new 3mm thick msonite laminated sheet top cover white or ivory fixed on 6/8 inch 4 inch MS box.
All as per BOQ item No 46.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 4 inch MS box.
Taking down carefully light fitting any type from surface/recessed/wall mounting type stacking at site for re-use or shifting unserviceable lights to store for taking credit all as directed and specified.
Supply and fixing LED lights fitting 1x 20W, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, including suitable bracket for fixing light on wall or any indicated location all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes.
S&F LED light fitting 1 x 10W bulkhead luminaires including in build LED light driver perfect interior and exterior application connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per Crompton cat ref no. LCTLR-36-FO-CDL or equivalent in approved makes.
M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7 mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete including concealed PVC conduit 20mm dia from TV Socket to dish antenna on roof of building complete all as specified. Note : 20mm conduit pipe inside building shall be concealed in wall surface and from external surface duly fixed with GI Saddles is deems to be included in quoted rates.
M&L for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
S&F Stepped type Modular /Non Modular electronic fan regulator, switch size, flush type 230V AC, for BLDC fans and supporting to all type ceiling fans. Note-Regulator should work on BLDC Fans and as recommended by Engineer-in charge.
M&L for SPN/DP RCBO 40 Amps 240 volts, 30 mA capacity and 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Make- Havells cat part no-DHCEACSN2030040 or equvelent make mentioned in Appx 'B'.
M&L for SPN/DP RCBO 32 Amps 240 volts, 30 mA capacity and 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Make- Havells cat part no-DHCEACSN2030032 or equvelent make mentioned in Appx 'B'.
S&F in replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete all as directed.
M&L for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of width all-around of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly reinforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
M/S VENUS BUILDER
DURGA ENGINEERING COMPANY
M/s Shiv Builder and Suppliers
M/S Balkishan Panwar Construction
VARDHMAN SALES CORPORATION
M/s Vishaka Enterprises
new india engineers
Shri Electrical Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .