Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.0 L+₹29,120 (0.79%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹44.6 L+₹7.9 L (21.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹46.3 L+₹9.5 L (26.0%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹47.8 L+₹11.1 L (30.1%)Rejected-Finance 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L5 | Rejected-Finance Being L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
REPAIR MAINTENANCE OF SUMMER APPLIANCES AND OTHER CONNECTED WORK IN CHANDIGARH AND RAMGARH AREA UNDER GE (I) R AND D CHANDGIARH
2024_MES_661615_1
GE I R AND D/CHD-41/2024-25
Open Tender
Civil Works
Item Rate
270 days
Ramgarh
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹96,000
Yes
23 Oct 2024
24 Jun 2024
24 Jul 2024
24 Jun 2024
22 Jul 2024
8 Jul 2024
Amount
RAMGARH AREA Providing services for attending all types of day to day complaints of maintenance, repair, replacement of unserviceable worn out spare parts, overhauling including soldering, spraying, chemical cleaning with detergents, leak repairing, charging fresh refrigerant, dismantling, reassembling and periodical services in respect of all make, work & type of cooling appliances i.e., air conditioners (window type, split type, cassette type and duct able type) , water coolers , desert coolers , water heater and voltage stabilizers installed at various labs/locations in TBRL range Ramgarh by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments/machine/test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp metre, brazing rod, butane gas cylinder, tape roll, vacuum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, & other instruments which are required for maintenance, repair and to make the equipment functional and for keeping all equipments in perfectly clean, tidy and functional condition in all times . The complaints record to be maintained on the complaint register & complaint slips complete all as specified and directed. Note: (i) Cost of spares including refrigerant for charging and rewinding /replacement of condenser fan motors, compressor , blower fan etc if required shall be measured and paid separately under respective item of sch'A' (ii) 01x ref mechanic and 1 x helper to be provided from 0900 hrs to 1700hrs. (iii) Non attending of complaints will be recovered @ Rs 250 per complaint ((iv) Location of complaints for any Ref mech /helper for item No-1 can be given for interest of the work a (v) The vehicles for attending complaint site (motorcycle or bicycle) provide by contractor.
CHANDIGARH AREA Providing services for attending all types of day to day complaints of maintenance, repair, replacement of unserviceable worn out spare parts, overhauling including soldering, spraying, chemical cleaning with detergents, leak repairing, charging fresh refrigerant, dismantling, reassembling and periodical services in respect of all make, work & type of cooling appliances i.e., air conditioners (window type, split type, cassette type and duct able type) , water coolers , desert coolers, water heater and voltage stabilizers installed at various labs/locations in TBRL range Ramgarh by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments /machine /test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp metre, brazing rod, butane gas cylinder, tape roll, vacuum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, & other instruments which are required for maintenance, repair and to make the equipment functional and for keeping all equipments in perfectly clean, tidy and functional condition in all times . The complaints record to be maintained on the complaint register & complaint slips complete all as specified and directed. Note: (i) Cost of spares including refrigerant for charging and rewinding /replacement of condenser fan motors, compressor, blower fan etc if required shall be measured and paid separately under respective item of sch'A' (ii) 01x ref mechanic and 1 x helper to be provided from 0900 hrs to 1700hrs.(iii) Non attending of complaints will be recovered @ Rs 250 per complaint((iv) Location of complaints for any Ref mech /helper for item No-1 can be given for interest of the work a (v) The vehicles for attending complaint site (motorcycle or bicycle) provide by contractor.
Supply only new blower motor (DC /AC ) for split type A/C unit of capacity 1.5/2.0TR as per existing model complete all as specified and directed.
Supply only air filter for split type A/C units of capacity 1.5 TR/2 TR as per sample complete all as specified and directed
Material and labour for providing insulation to copper tubing from indoor to outdoor units with foam insulation followed with PVC flexible pipe 50mm with clamps complete all as specified and directed
Supply only copper tubing 3/8” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed
Supply only indoor unit complete suitable for existing outdoor unit of any make of split AC of cap 1.5/2.0TR complete all as specified and directed
Supply only copper tubing 5/8” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed
Supply only copper tubing 1/2” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed
Supply only copper tubing 1/4” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed
Supply only starting relay for split type AC units of capacity 2 TR as required at site complete all as specified and directed.
Supply only contactor (max type), as per existing model, coil voltage 230V installed in split type AC units complete all as specified and directed
Supply only bush/bearings of condenser fan motor of split type AC units of capacity 1.5 TR/2 TR complete all as specified and directed.
Supply only bush/bearings of blower fan motor of split type AC units of capacity 1.5 TR/2 TR complete all as specified and directed.
Supply only indoor unit blower suitable for split AC capacity 1.5 / 2.0 TR complete all as specified and directed
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and replacing the same with new one from the company as per existing model complete all as specified and directed
Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and replacing the same with new one from the company as per existing model complete all as specified and directed
Supply only outdoor unit complete suitable for existing indoor unit of any make of split AC of cap 1.5TR complete all as specified and directed
Supply only outdoor unit complete suitable for existing indoor unit of any make of split AC of cap 2.0TR complete all as specified and directed
Supply only the new remote control unit (cordless)as per existing model for 1.5 TR/ 2 TR split type A/C unit complete all as specified and directed
Supply only condenser fan blade for split AC 1.5/2.0 TR complete all as specified and directed
Supply only drains hose pipe of length 05 metre for air conditioner/ water cooler complete all as specified and directed.
Supply only printed circuit board (PCB) of cooling unit of split AC 1.5TR/2.0TR as per sample of any make complete all as specified and directed
Supply only thermostat for split type AC 1.5/2.0 TR as required at site complete all as specified and directed
Supply only overload protector for compressor as required at site for AC 1.5/2.0TR complete all as specified and directed
Supply only starting relay as required at site for water coolers complete including connecting, testing complete all as specified and directed .
Disconnecting and rewinding of condenser motor single phase of 1/16 HP for water coolers and refixing the same with clamps bolts, nuts and rubber bushes including connecting, testing complete all as specified and directed
Supply only of gas R-22 complete all as specified and directed
Supply only of gas R-32 complete all as specified and directed
Supply only waste water tray as required at site made out of 20 gauge GI sheet complete with PVC drain pipe including painting with PVC drain pipe including painting with aluminium paint complete all as specified and directed
Supply only brass float valves accessories 15mm size as required at site complete all as specified and directed
Supply only starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 1.5TR/2 TR complete all as specified and directed
Disconnecting and taking out compressor ('R’ type) from water cooler and fixing new including flushing dehydration and gas charging complete all as specified and directed
Supply only running capacitor 30/36 mfd for split type AC unit as required at site complete all as specified and directed
Supply only capacitor 10 MFD suitable for air conditioner/ water cooler complete all as specified and directed
Supply only self closing taps of cast iron galvanised, chromium plated screwed for iron pipe suitable for water coolers complete all as specified and directed.
Supply only new condenser motor single phase of 1/16 HP as required at site for water cooler with clamps, bolts, nuts and rubber bushes complete including connecting testing complete all as specified and directed
Supply only distribution box with plug and socket and 20 A DP with plastic cover complete all as specified and directed.
Supply only new desert cooler pump. including testing for proper functioning complete all as specified and directed
Supply only wood cool pad set of three for desert cooler complete all as specified and directed.
Supply only desert cooler motor single phase, 50 Hz, 250 Volt, 180 W, 1400 RPM complete all as specified and directed
Supply only new body of desert cooler as per sample duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle, distributor and nut bolts washers for fixing fan clamps, complete all as specified and directed
Supply only front grill of desert cooler as per sample complete all as specified and directed
Supply only PVC distributor of desert cooler heavy duty as per sample complete all as specified and directed.
Supply only plug top 5 Amps complete all as specified and directed
Supply only plug top 15 Amps complete all as specified and directed
Supply only PVC flexible pipe 15mm bore heavy duty for desert cooler complete all as specified and directed
Supply only capacitor 40/45 mfd for AC as required at site complete all as specified and directed
Supply only capacitor 4 mfd for desert/water cooler as required at site complete all as specified and directed
Supply only over load protector for 1.5/2.0 TR W/AC complete all as specified and directed
Supply only blower motor as required at site for W/Ac single phase 230 volts double shaft with clamp bolts, nuts and rubber bushes complete all as specified and directed.
Supply only air filter of w/AC 1.5 TR capacity make-coir foam or equivalent as required at site complete all as specified and directed
Supply only starting relay for W/T A/C as required at site complete all as specified and directed
Supply only capacitor 50+6 mfd for AC as required at site complete all as specified and directed
Supply only thermostats as required at site complete for window type AC 1.5 TR complete all as specified and directed
Disconnecting and taking down compressor 1.5 TR W/AC as per existing make and refixing the same after replacing with new one including flushing, dehydration and gas changing complete all as specified and directed
Disconnecting and taking down compressor 2 TR W/AC as per existing make and refixing the same after replacing with new one including flushing, dehydration and gas changing complete all as specified and directed
Supply only of gas R-134A complete all as specified and directed
Supply only of gas R-410A complete all as specified and directed
Disconnecting and taking down of window type AC 1.5 TR of any make and refixing the same after replacement of cooling coil including soldering/welding dehydration complete all as specified and directed
Supply only blower suitable for window AC capacity 1.5 / 2.0 TR complete all as specified and directed.
Disconnecting and taking down of window type AC of any make and refixing the same after replacement of condenser coil including soldering/welding and commissioning complete all as specified and directed
Servicing and minor repair if any to voltage stabilizer of capacity 5 KVA complete all as specified and directed
Servicing and minor repair if any to voltage stabilizer of capacity 4 KVA complete all as specified and directed
Supply only PVC insulated copper conductor cable of size 3 core, 1.0 sqmm, 1100 volt grade complete all as specified and directed
Supply only PVC insulated copper conductor cable of size 3 core, 1.5 sqmm, 1100 volt grade complete all as specified and directed
Supply only PVC insulated copper conductor cable of size 3 core, 2.50 sqmm, 1100 volt grade complete all as specified and directed
Taking out of old, unserviceable worn out existing mild steel stand of any size and replacement fMS stand of suitable size fabricated out of angle iron alongwith 02 nos legs duly grouted on walls of the building near window and 02 nos diagonal angle iron supports duly welded to frame and legs and painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for shifting of AC's any type/capacity from any height and location and refix the same on another location after making necessary cutting on wall/roof/window/glass/grills as per requirement of users, complete all as specified and directed. (Note:- Necessary insulation for copper tubing, gas filling, ply work shall be measured and shall be paid separately under respective item)
Taking down carefully by sub main wiring/service connection of any type complete all as specified and directed
Material and labour for sub main wiring with two runs of single core, PVC insulated, unsheathed, multi standard copper conductor cable of size 4 sqmm, 1100 volts grade and one run of 4.0 sqmm PVC insulated earth continuity copper conductor cable drawn through and including suitable size of PVC concealed conduit with all necessary accessories such as bends, tees, junctions boxes, elbows etc complete with all in coming and out going cable connections complete all as specified and directed. (Note : Two runs of 4 sqmm cable, one run of 4.0 sqmm continuity earth wire and one run of PVC conduit with all necessary accessories shall be measured as one unit length).
Supply and fixing in replacement of PVC connections 15 mm size with PTMT nuts of length 450 mm suitable for water coolers/geysers complete all as specified and directed.
Supply and fixing in replacement of PVC connections 15 mm size with PTMT nuts of length 600 mm suitable for water coolers/geysers complete all as specified and directed.
Supply, installation and testing of printed control board of indoor unit and outdoor unit both of cassette type AC (inverter type) cap 2.5 TR as per sample complete all as specified and directed
Supply, installation and testing of printed control board of indoor unit and outdoor unit both of cassette type AC (inverter type) cap 4.0 TR as per sample complete all as specified and directed
Supply and fixing in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle, fancy type and chromium plated screwed both ends for iron pipe or for unions of size 15 mm bore , complete all as specified and directed
Supply and fixing in replacement of 15 mm nominal size, screw down bib taps, cast copper alloy with crutch or butterfly handle screwed down, fancy type, chromium plated complete all as specified and directed.
Supply and fixing in replacement of apparatus plate (geyser assembling unit) with rubber gasket including nuts, bolts and washers consisting of 6 nos of holes suitable for existing geysers complete all as specified and directed.
Supply and fixing in replacement of apparatus plate (geyser stainless steel assembling unit ) with rubber gasket including nuts, bolts and washers consisting of 9 nos of holes suitable for existing geysers complete all as specified and directed
Supply only thermostat 7'/11' for geyser with adjustable temperature setting range complete all as specified and directed
Supply only brazing rod for copper tube welding complete all as specified and directed
Supply only butane gas cylinder 230 gram for brazing rod welding complete all as specified and directed
Supply only suction valve with dead end cap at outdoor unit of split type air conditioner 1.5/2.0 TR complete all as specified and directed
Supply only discharge valve with dead end cap at outdoor unit of split type air conditioner 1.5/2.0 TR complete all as specified and directed
Supply and fixing for voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed
Supply and filling compressor oil complete all as specified and directed.
Supply, install, testing and commissioning of hermetically sealed scroll compressor of capacity 11.00 ton 3 phase 440 volts compatible with R22 refrigerant gas , suitable for water cooled AC plant complete all as specified and directed.
Supply, install, testing and commissioning of hermetically sealed scroll compressor of capacity 8.5 ton 3 phase 440 volts compatible with R22 refrigerant gas , suitable for duct able AC complete all as specified and directed.
Supply, install, testing and commissioning of hermetically sealed scroll compressor of capacity 5.5 ton 3 phase 440 volts compatible with R22 refrigerant gas , suitable for duct able AC complete all as specified and directed.
Taking out old unserviceable power/auxiliary contactor from control panel / starter and supply and fix new power contactor of following size and capacity complete all as specified and directed:- Power contactors of AC3 rating 9-12 Amps MNX/MO type
All as per serial item no 91.00 above but power contactors AC3 rating 25 Amps ML/MNX/MO (as per existing) type-ditto-.
All as per serial item no 91.00 above but power contactors AC3 rating 32-40 Amps ML/MNX/MO (as per existing) type -ditto-
Supply ,installation, testing and commissioning of centrifugal monoblock type pumping set i.e chiller water pump having discharge capacity minimum 500 LPM at 45 m head coupled with electric motor 3 phase, 415 volt ,50 Hz of suitable capacity (approx 10 HP or above) to drive pump delivering water up to 45 m head and suction del pipe size 100mmx80mm ,mounted on common MS base frame including pcc foundation, nut, bolts etc complete all as specified and directed
Supply ,installation, testing and commissioning of centrifugal monoblock type pumping set i.e chiller pump or condenser pump for AC plant having discharge capacity minimum 400 LPM at 35 m head coupled with electric motor 3 phase, 415 volt ,50 Hz of suitable capacity (approx 7.5 HP or above) to drive pump delivering water up to 45 m head and suction del pipe size 100mmx80mm ,mounted on common MS base frame including pcc foundation, nut, bolts etc complete all as specified and directed
Supply only printed circuit board (PCB) of servo voltage stabilizer up to 10 kVA to 20 KVA as per sample of any make complete all as specified and directed
Supply and fixing in replacement of exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250mm complete all as specified and directed
Supply and fixing for exhaust fan metallic body size 300 mm sweep with louvers, operated on 230/240V AC single phase electric supply 900 RPM complete including connecting with 3 core stranded copper conductor cable cord of size 0.5 sqmm from ceiling rose to fan connector complete all as specified and directed.
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc complete all as specified and directed
SANJEEV ENTERPRISES (BID ID -3061160)
Bharat Enterprises (BID ID -3065909)
satpal and brothers (BID ID -3070464)
ALPHA ENGINEERS AND BUILDERS (BID ID -3068913)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .