Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC | L1 | Accepted-AOC Agreement executed |
Tender Value
₹1.9 L
EMD Value
₹4,650
Closing Date
26 Sept 2024, 5:00 pmClosed
AEE
Harbour Engineering Construction subdivision, Beypore
Beypore Port - Upgradation of water supply system-Upgradation of water supply system and maintenance of SPC office building-General Civil Work
2024_HED_690394_1
Re-Tender HED/03/AEE(C)/24-25
Open Tender
Civil Works - Others
Item Rate
365 days
Beypore Port
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹4,650
18 Feb 2025
9 Sept 2024
28 Sept 2024
10 Sept 2024
26 Sept 2024
10 Sept 2024
10 Sept 2024 - 12 Sept 2024
Amount
APPENDIX - A
15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
18.31.3.2:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately): 150 mm diameterClass II
18.19.4.2:Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreVertical
18.19.4.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
50.18.8.6.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet
15.19:Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.
OD5115/2023-2024:Roofing with Aluminum traffored profile sheet powder coated approved colour ,fixing using stainless steel self drilling type high tensile strength screws with matching colour caps over fatner head fibre washers and silicon water profing sealant with necessery over laps at endsincluding cost and conveyance of all materials ,labour charges etc. complete.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
18.60.1:Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore
OD5190/2023-2024:Engaging coolie for cleaning and other petty works
OD3004/2024-2025:Supplying & fixing 10" PVC square gutter including clamps and fixtures for fixing
OD3068/2024-2025:Drilling Hole-For fixing MS plate on wall to hanging the angle sections of steel platform.
OD3119/2024-2025: bolts and nuts 6 mm dia and 25 mm long
Bidder Name
shigan kalankoli
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1074533.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .