Executive Engineer PHE Mech. Division Rajouri
Executive Engineer PHE Mech. Division Rajouri
Providing, installation, testing and commissioning of automatic LT control panel 415 volts, AC-3 Phase, 50 Hz. for 40 HP motor at pumping stations Lambri Jamina, Dharat old base, chakjarallan and Koterkhana.
2021_PHE_117296_1
e-NIT PHE/MDR/ 72 of 2020-21 DATED 18-02-2021
Open Tender
Machineries/ Mechanical Engg Items
Percentage
10 days
Rajouri
Please refer Tender documents.
3 documents required · 3 mandatory
₹250
Yes
Executive Engineer PHE Mech. Division Rajouri
Yes
27 Feb 2021
19 Feb 2021
26 Feb 2021
19 Feb 2021
25 Feb 2021
19 Feb 2021
Amount
Designing, fabrication, installation, testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. for 40 HP motor at pumping station......................... The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle job suitable size and provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given a coat of anti rust primer and two coats of steel grey paint. The panel should have equipped with following components / features: 1) M.C.C.B. The panel should be fitted with an M.C.C.B. of suitable capacity, 1 no. volt meter, 1 no ammeter along with a set of CTs, 1 No. V.S.S., 1 No. A.S.S. and a set of RYB indicators at incoming side. 2) Star delta Starter The panel should be fitted with a fully automatic star delta starter comprises of 3 Nos. air break contactor of suitable capacity (2 for main and delta supply, 1 No. air break contactor for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB 2 Amps. for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables to complete the star delta circuit of outgoing supply. 1) Protections devise / fault analyzer A protections devise / fault analyzer shall be fitted with the panel with capability to: a)Protect the motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings: i) Voltage related fault: Single phasing, reverse phase, under voltage, over voltage, unbalance voltage. Ii) Current related fault: Over load, Under load (dry running), unbalance load, earth leakage, short circuiting Short circuit a) Display line current of R, Y & B Phase and also line voltage of RY, YB and BR phase. Bimetal overload relay: A bimetal over load relay of suitable range should be fitted with in the starter as an extra protection to protect the motor in case of failure of fault analyzer with an isolation/bye pass switch to bye pass the fault analyzer. Complete job includes cost of Supply, loading, transportation (MT), insurance, Unloading, carriage/ shifting (head load), fitting, installation ,testing and commissioning at site.
PERFECT ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .