GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2020_MES_407898_1
GE MAINT EZHIMALA 8357
Open Tender
Civil Works
Item Rate
180 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹32,000
Yes
8 Feb 2021
29 Dec 2020
30 Jan 2021
29 Dec 2020
28 Jan 2021
12 Jan 2021
30 Dec 2020 - 5 Jan 2021
60 days
Amount
Material and labour for colour code point wiring with FRLS PVC insulated and unsheathed cable of 1.5 Sqmm copper conductor single core multistrand 1100 Volt grade confirming to IS 694 drawn through casing caping / PVC conduit of suitable size but not less than 25mm width and all accessories fixed to the chases on the walls etc, Junction boxes, suitable modular plates including suitable modular boxes made out of GI sheet of thickness should be not less than 1.2mm thick or Modular PVC box as per site requirement and modular plates/modular switches concealed in wall and 1.5 sqmm copper conductor as earth continuity wire to connecting common earth dolly complete all specified and directed for the following:- Note:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) cutting of chases on the wall and filling with cement mortar, after fixing of PVC casing & capping, shall be included in the quoted rate.
One light point/fan point controlled by one switch.
One socket point 6 Amp independent controlled by one switch.
Add to 1.01(a) for additional light point on the same switch circuit for five light point controlled by one switch.
Add to 1.01(a) for additional light point on the same switch circuit for two light point controlled by one switch.
All as per item no 1 above but using 2.5 sqmm cable for wiring for socket point
S&F Modular switch one way 6A,1 module, ISI marked as specified and directed by Engineer in charge.
S&F Modular switch one way 16A,1 marked as specified and directed by Engineer in charge.
S&F Modular fan regulator 120W 2 marked as specified and directed by Engineer in charge.
S&F Modular socket 6 Amps 16 A 2/3 pin 2 marked as specified and directed by Engineer in charge.
S&F Modular socket 6 Amps 2/3 pin 2 marked as specified and directed by Engineer in charge.
S&F Ceiling rose three terminal surface bakelite type AC 50Hz, 230 Volts complete all specified and directed.
S&F single pole and neutral enclosure with 2 pin and earth plug and socket complete with and including one single pole MCB 20 amps complete all specified and directed.
S&F MCB single pole 6 to 32 Amps capacity 230 Volts 10KA C curve complete all specified and directed by Engineer in charge.
S&F MCB single pole and neutral 32 Amps capacity,10 KA,50 Hz , 230 Volts complete all specified and directed by Engineer in charge.
S&F MCB single pole and neutral 40 Amps capacity,10 KA,50 Hz , 230 Volts complete all specified and directed by Engineer in charge.
S&F MCB DB SPN 8 way 230V double door type with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete all specified and directed by Engineer in charge.
S&F in repair MCB DB TPN double door for 4 way with 200 Amps rated bus bar 415 Volts complete all specified and directed by Engineer in charge.
S&F in repair MCB DB TPN double door for 6 way with 200 Amps rated bus bar 415 Volts complete all specified and directed by Engineer in charge.
S&F MCB TPN 415 Volts 63 Amps complete all specified and directed by Engineer in charge.
S&F MCB TPN 415 Volts 40 Amps complete all specified and directed by Engineer in charge.
S&F 33 W (+/- 2w ) LED 2x2 fitting with 4200 lumens light output, greater than 125 lumens per watt system efficiency, Ripple less than 5 %, CRI -80,Internal surge protection up to 4 KV, power factor > 0.95, THD< 10 % polystyrene diffuser for UGR less than 22. 50,000 burning hours as per L70 and 4000 K CCT. The luminaire shall be suitable for DALI dimming option of Philips /Jaquar/Crompton/Havells complete all specified and directed by Engineer in charge.
S&F 40 W (+/- 5w ) LED Track light with 4000 lumens light output, greater than 85 system efficiency 125 lumens per watt , Narrow beam angle and 4000 K CCT. Fitting shall be suitable for mounting on 3 wire Track including making connection with existing terminal block with suitable size of cable complete all specified and directed by Engineer in charge.
S&F LED Flood light made up of pressure diecast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection, option for 3000K CRI not less than 70,PF 0.95,Lumens per watt not less than 100,CCT 5700 K complete all specified and directed by Engineer in charge.
M&L sub main wiring using 2 runs of 2.5 Sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through suitable size of PVC casing caping along with 1run of 2.5 Sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly complete all specified and directed by Engineer in charge. Note:- (i) One run of PVC casing caping,3 runs of 2.5 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral, green for earthing.
M&L sub main wiring using 2 runs of 2.5 Sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through suitable size of PVC conduit along with 1run of 2.5 Sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly complete all specified and directed by Engineer in charge. Note:- (i) One run of PVC conduit,3 runs of 2.5 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral, green for earthing.
M&L sub main wiring using 2 runs of 4 Sqmm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through suitable size of PVC conduit/PVC casing & capping along with 1 run of 4 Sqmm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly complete all specified and directed by Engineer in charge. Note:- (i) One run of PVC conduit/PVC casing & capping,3 runs of 4 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral, green for earthing.
All as per item No.21 above but 4 runs of 6 sqmm FRLS plc. cable and 2 runs of 6 sqmm FRLS insulated copper conductor cable as earth lead complete all specified and directed by Engineer in charge. Note:- (i) One run of PVC conduit/ casing and caping,6 runs of 6 sqmm PVC insulated copper conductor cable will be measured as one unit. (ii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral, green for earthing..
M & L for maintenance free chemical earthing with 2 no's of copper cladded 17 mm dia nickel cadmium steel with high tensile strength electrode of each of 1.8 m each jointed with suitable compressive coupler planted at depth not less than 3.6 m depth and duly covered with low resistant superior conductive powdered non corrosive earth enhancing material all as directed as per OEM specification including connecting up to the common bus bar for a length up to 7.5 m with copper strip of size 25 x 4 mm to achieve an earth resistance of below 1.0 ohms.
Note:- (i) Three no's earthing shall be made for each grid and it shall be connected together for obtaining lowest earth resistance which shall be less than 1 Ohm. (ii) Electrode and copper strip of size 25x4 mm shall be welded using exothermic welding for interconnecting the earth electrodes and from earth to grid up to 15 m along with 40 mm dia GI light grade protection pipe. (iii) The carbon based compound shall have a resistance value of not less than 0.1 ohm. The compound shall be of minimum 30 kg per pit. (iv) The bore hole for earth electrode shall not be not less than 100 mm dia and 2 metre deep from GL and the extended rod shall be driven to a total depth of 4 metre. (v) Provision of earth pit chamber of internal size 150 x150 x 150 mm depth with PCC 1:3:6 cover slab 40 mm thick with reinforcement of 8 mm TMT bars @ 100 mm c/c both direction for each earthing all as directed by Engineer in Charge. (vi) Necessary earth work excavation in any type of soil ,returning filling in and making good the surrounding area complete. (vii) All the joints except test point shall be welded/ brazed properly and the copper earth strip whenever laid on the wall, floor etc shall be fixed on ceramic insulators not more than 600 mm apart.
Supply and fix copper strip 25x3 mm with saddles and fixing screws etc. for roof conductors/ down conductors / connecting to earth pit to equipment and brazing all the joints complete all specified and as directed.
Supply and fix DMC/FRP insulators of suitable size to separate the earth strips from the walls, duly screwed on the walls and making holes in the earth strips by drilling and fixing the earth strip rigidly with the insulators with GI bolts, nuts, washers etc complete all specified and directed.
Supply and fixing Air circulator (wall mounted fan) AC single phase 230/ 240 V of size 600 mm sweep, 1440 RPM, input power watt 180, heavy duty complete all specified and directed.
S&F in replacement suspended luminaires 36W LED 4 feet with colour temperature 6000K having extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including 02 Nos suspension kit, CRI -80,THD- < 10 %,Lumens >100,Powerfactor-.0.92,Internal surge voltage- 2kv, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals as specified and directed by Engineer-in-Charge.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx. storage and nominal cooling capacity of 40/80 Litres respectively including necessary platform and inlet pipe connection as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA
Supply and fix UV+UF water purifier complete with purification capacity of minimum 60 Litre/hour without storage type and prefilter to be connected in between purifier and water inlet for purification as specified and directed by Engineer in charge.
S&F in repair modular socket 6 Amps 2/3 pin 2 marked complete all specified and directed.
Supply and fix LED flood light fitting with robust design 150 watts, IP 66 protection and built in voltage surge protection as specified and as directed by Engineer in charge. Lumens->110 lumens/watt, CRI->80, THD- < 10, PF-0.95 ,Internal surge voltage- 10 KV complete all specified and directed.
Supply and fix copper cable flexible 2.5 sqmm 3 core 230 volts complete all specified and directed by Engineer in charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volts grade, cross sectional area 35 sqmm 3.5 core including necessary connection to the DB with suitable aluminium lugs and cable should be clamping on wall /ceiling as specified and directed by Engineer in charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volts grade, cross sectional area 25 sqmm 3.5 core including necessary connection to the DB with suitable aluminium lugs and cable should be clamping on wall /ceiling as specified and directed by Engineer in charge.
S&F Switch socket combination 5 pin,6 Amp ISI Marked with PVC box as specified and directed by Engineer in charge.
S&F Switch socket combination 5 in 1, 5 Amp/15 Amp ISI Marked with PVC box as specified and directed by Engineer in charge.
S&F MCB protected socket 25 Amp ISI Marked with PVC box as specified and directed by Engineer in charge.
S&F Plug top suitable for 6Amp/16Amp/25 amp ISI Marked as specified and directed by Engineer in charge.
S&F MCB DB SPN 230V double door type 6 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete all specified and directed by Engineer in charge.
S&F GI perforated cable tray with all accessories ISI Marked as specified and directed by Engineer in charge.
S&F in RCBOs for earth leakage protection 4 pole 30m Amps,63 Amps,415 Volts complete all specified and directed by Engineer in charge.
S&F MCB protected modular socket (Modular AC Box) 25Amp, heavy duty 230 V AC ISI mark complete all specified and directed by Engineer-in-charge.
S&F of MCB DB, 4-way triple pole vertical type, double door, 415volts 50Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) and connecting the electrical connections and making good the disturbed surface wall with the existing wall complete all specified and as directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply, complete all specified and as directed.
S&F MCB 'C' series TPN 40Amps rating, 10 KA breaking capacity, 440V, 50Hz, AC supply, complete all specified and as directed.
S&F MCCB, 4 pole , 16/18KA , 63 Amps rating, 440V, 50Hz, AC supply, complete all specified and as directed.
S&F MCCB enclosure for F frame MCCB four pole with neutral link, earth bar and DIN rail complete all specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4core duly saddled on wall by providing GI bar saddle duly fixed through gutties & screw not more than 50cm apart from each other complete all specified and directed by Engineer-in-Charge.
Supply, Installation & commissioning of split type Inverter Air Conditioner 2TR, BEE 3 star rated capacity suitable for operation on 230 volts, 50Hz, single phase AC supply, wall mounted with indoor unit, out door (condensing) unit to be fixed on readymade brackets / M.S. Angle stand as per site requirement complete in all respect including core cutting in brick/concrete/stone wall including arrangement of required T&P, copper refrigerant pipes for suction & discharge lines of standard size as per site requirement duly insulated, condensate water outlet pipe and 3 core copper wire of required length between stabiliser & indoor (in PVC casing caping)/outdoor units, leak check and topping up of refrigerant gas up to recommended level, making good the disturbed surface including making good the PCC and brick work and testing the unit for satisfactory functioning, complete all specified and directed. Note:- (a) The refrigerant of Air conditioner shall be in compliance of Non-CFC norms. (b) Air conditioner shall be initial filled/charged with refrigerant of specified quantity. (c) Additional refrigerant pipes required beyond the length as supplied by OEM, shall be included in the unit rate quoted. (d) Split type AC comprising of indoor and outdoor unit to be supplied with remote control for operation.
Supply & installation, connection, testing and commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 130 volt to 300 volt with output voltage stabilized at 230 V with accuracy of ± 2.5%, Load capacity 15 Amp suitable for 2Ton Air Conditioner including cable connection in PVC casing caping from socket to stabilizer, complete all specified and as directed.
M&L for rigid PVC conduit (medium grade) size 25 mm dia including fittings such as elbow, bend & tee etc. for water drain out line for AC, duly saddled on walls/floors with clamping/fixing nuts complete all specified and directed.
M&L for copper piping of size 5/8" and 1/4" with proper insulation suitable to 2TR Air Conditioner as extra length to lead conduits complete as specified and directed by Engineer-in-Charge. Note:- One running meter of both size of copper tubes with insulation will be measured as One Unit.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below GL) with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth wire 4mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 metre, provision of charcoal and salt complete all shown in electrical plate No 3 of schedule Part-I Note: (i) Cost of GI earth wire and GI protection pipe up to 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit
Supply and fix GI wire 4mm with saddles and fixing screws etc. for roof conductors / down conductors / connecting to earth pit to equipment including removing the old unserviceable strip and brazing all the joints complete all directed..
ANAND REFRIGERATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .