Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹44.7 L+₹2.2 L (5.14%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹44.9 L+₹2.4 L (5.64%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹46.0 L+₹3.5 L (8.20%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹46.1 L+₹3.5 L (8.33%)Rejected-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
10 Mar 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
SPECIAL REPAIR_ REPLACEMENT OF LT PANELS AND OTHER CONNECTED WORK AND PROVN OF CERTAIN SANCTIONED WORK AT VARIOUS LOCATION AT INAZ VILLAGE VERAVAL AND OTHER LOCATION UNDER GE I CG PORBANDAR
2022_MES_508927_1
8713
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Porbandar
Please refer tender Documents
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹83,000
Yes
11 Apr 2022
18 Feb 2022
11 Mar 2022
18 Feb 2022
10 Mar 2022
4 Mar 2022
18 Feb 2022 - 3 Mar 2022
Amount
SCHEDULE 'A'
Supply, fixing and install hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum BEE 5 star rating of capacity 1.5 Ton Inverter type, electric driven, single phase, 230 Volt, Heavy duty outdoor unit mounting bracket/stand complete all as specified and directed. Make : Voltas 185VJZJT 1.5 Inverter or Equivalant of Hitachi/Blue Star
Supply, fixing and install hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum BEE 5 star rating of capacity 2.0 Ton Inverter type, electric driven, single phase, 230 Volt, Heavy duty outdoor unit mounting bracket/stand complete all as specified and directed. Make : Voltas 245VADZ 2.0 Inverter or Equivalant of Hitachi/Blue Star
Supply, install and commissioning of water cooler, partially stainless steel, electric driven, single phase having approximate cooling capacity of 60/120 Ltrs and per hour also with and including PCC 1:2;4 raised plateform for installation of water cooler and drainage system as per manufacturer's instructions, complete all as specified and directed. Make : Blue Star or equivalent of makes Voltas /Usha
Supply, install and commissioning of Refrigerator Electric Driven, Single Door, Direct-cool single-door refrigerator; 215 litres capacity BEE 5 star rated, Free Operation with 360 Degree Air Flow, Internal LED illumination, with toughened and translucent shelving, compartments and trays with external locking arrangement with key, complete all as specified and directed. Make: LG Scarlet Charm, GL-B221ASCZ /Samsung/ Godrej.
Supply and fixing of Single pole and neutral enclosure wall Socket with DIN - Rail, IP 66 with SPN MCB 16/20Amps, Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper all as specified and directed by Engineer in Charge. Conforming to Cat No - AR 119 306 TS (16/20 A 2P + E) & Plug Watertight Cat No. 219306 of Hensel or Equivalent from Hager.
S & F VTPN DB 04 Way made of CRCA sheet, for flush mounting type with 250 Amp busbar copper, fully insulated & shrouded neutral bar, earth bar, fixed on wall, Prefitted masking sheet, Reversible Door confirming to IP 54 all as specified and comprising of following:- (i) MCCB 160 amp FP 36 KA 01 no (incoming) (ii) MCB 63 amp TP 25 KA C curve : 3 Nos (iii) MCB 6/32 amp SP 10 KA C Curve : 03 Nos MAKE: SCHNEIDER/ LEGRAND/ HAGER
Supply and Fix MCCB Metal enclosures, MCCB FP 63 Amps 415 Volts 16 KA fixing in Metal enclosure, in wall mounted type concealed/ Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper all as specified and directed by Engineer in Charge. Conforming to Cat No - 5078 01 & 4200 13 of Legrand or Equivalent from ABB/Havells/Schneider
S & F MCB DB 12 way SPN, PC (Polycarbonate), IP 65 “Weather proof” Concealed/ Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper all as specified and directed by Engineer in Charge. Make : Hensel / Hager.
Supply and fixing of MCB SPN, 240 volt, 16/20 Amps complete all as specified. Make: Legrand/ABB/Havells/Schneider
Supply and fixing of MCB SP, 240 volt, 6/32 Amps complete all as specified. Make: Legrand/ABB/Havells/Schneider
S & F Rigid non-metallic PVC conduit of size 25 mm dia, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including fixing arrangements/mounting brackets complete all as specified and directed. Make:Supreme/Astral/Plaza/Anchor Note: Drawn through wall surfaces AC copper conductor cables and waste water pipe, and including making good the disturbed surfaces of walls/ceiling/floor etc.,
S & F uPVC pipes of size 65 mm dia SCH-40 with fittings like elbow, tee, male threaded adapter, female threaded adaptor and unions incl fixing solvents all as per manufacturers recommenations and including fixing arrangements/mounting brackets complete all as specified and directed. Make:Supreme/Astral/Plaza/Anchor Note: Drawn through wall surfaces AC indoor and outdoor copper pipes, and including making good the disturbed surfaces of walls/ceiling/floor etc.,
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 50 Sqmm 3.5 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc all connections complete as required at site and as directed. Make: Havells/ Polycab/RR Kable/ KEI
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 35 Sqmm 3.5 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc all connections complete as required at site and as directed. Make: Havells/ Polycab/RR Kable/ KEI
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 16 Sqmm 4 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc all connections complete as required at site and as directed. Make: Havells/ Polycab/RR Kable/ KEI
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
S & F of GI steel tubing light grade 50 mm dia for laying in ground and road crossing along the pole in coping etc for cable protection including necessary fittings, clamps for supports, etc., including making good the disturbed surfaces of walls/floor etc all as specified and directed. Make - Tata/Jindal/Surya Prakash
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil.
Supply and lay 50 /38 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. Make: Rex/Poly/Gemini
Material & labour for Sub main wiring with two runs of 4.00 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC concealed/wall suface, making good the disturbed surfaces of walls/ceiling/floor etc., Conduit heavy duty grade ISI marked 20 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor complete all as specified and as directed. Note: All runs of cable and 1 run of conduit shall be measured and paid as one metre length of unit.
All as per Item no. 22 herenin above but 2x6.0 sq. mm +1x4.0 sq. mm earth wire complete all as specified and as directed.
M&L for bore Earthing, 150 mm bore for earthing with maintenance free chemical earthing using copper electrode of size 19 mm dia - 01 No, 3 m long, Copper earth strip, excavation and earth work, back fill with compound (Chemical for earth enhancer gel 2 x 25Kg) - 01 set. all as directed, shall be deemed to be included in the unit rate. Note: (i) IR Value should be less than 1.0 ohm. (ii) Copper earth stip of size 20 x 3.15 mm including installation 7.5 Mtr (Copper purity not less than 99%) is deemed to be included in the unit rate. (iii) Suitable FRP Chamber should be included in the unit rate.
Taking down the LT Panel of any size by disconnecting incoming and outgoing cable connection and getting bus bar further taken into schedule of credit all as directed by engineer-in-charge.
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, RAL 7035 finish confirming to IP 54 complete including Cu bus bar 630 Amps, 36 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Location : Power House
(a) Incoming MCCB 400 Amps four pole with Thermal based operated, having breaking capacity 25 KA, - 01 Nos
(b) Outgoing MCCB 200 Amps four pole with Thermal based operated, having breaking capacity 16 KA, - 02 Nos.
(c) Outgoing Blank compartment - 04 Nos (Suitable fixing for MCCB 200 Amps to 250 Amps four pole)
(d) Digital Voltmeter 0-500 V 96x96m - 01 nos.
(e) Digital Ammeter 0-500 A 96x96m - 01 nos.
(f) Indicating Lamps set RYB - 01 set Make : LT Panel polycarbondate : Hensel/Universal/Neptune. Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication.
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, RAL 7035 finish confirming to IP 54 complete including Cu bus bar 400 Amps, 36 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Location: MT Panel
(a) Incoming MCCB 250 Amps four pole with Thermal based operated, having breaking capacity 25 KA, - 01 No
(b) Outgoing MCCB 160 Amps four pole with Thermal based operated, having breaking capacity 16 KA, - 02 Nos.
(c) Outgoing Blank compartment - 04 Nos (Suitable fixing for MCCB 100 Amps to 160 Amps four pole)
(d) Digital Voltmeter 0-500 V 96x96m - 01 Nos.
(e) Digital Ammeter 0-500 A 96x96m - 01 Nos.
(f) Indicating Lamps set RYB - 01 Set Make : LT Panel polycarbondate : Hensel/Universal/Neptune. Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication.
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, RAL 7035 finish confirming to IP 54 complete including Cu bus bar 300 Amps, 36 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Location: Galley
(a) Incoming MCCB 200 Amps four pole with Thermal based operated, having breaking capacity 25 KA, - 01 No
(b) Outgoing MCCB 100 Amps four pole with Thermal based operated, having breaking capacity 16 KA, - 02 No.
(c) Outgoing Blank compartment - 03 Nos (Suitable fixing for MCCB 100 Amps Amps four pole)
(d) Digital Voltmeter 0-500 V 96x96m - 01 No.
(e) Digital Ammeter 0-500 A 96x96m - 01 No.
(f) Indicating Lamps set RYB - 01 Set Make : LT Panel polycarbondate : Hensel/Universal/Neptune. Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication.
Supply and fix MCCB FP 160 Amps , 415 V, breaking capacity 16 KA, Adjustable type, exisisting cables and connecting the cables with proper lugs and glands complete all as specified and directed. Make: L&T/ ABB/Havells
M&L for Stright through joint of size 70 to 120 Sqmm, regin cast complete type LT PVC / XLPE cable upto 1.1 KV complete with all accessories and generally conforming to IS 8438/1977 complete all as specified and directed.
SURESH ELECTRICALS
Parth Infrastructure Pvt. Ltd.
JAMNAGAR ELECTRIC AND MACHINERY CO
M/s SK Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .