Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAdmitted-Finance JABALPUR | ₹3.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.6 Cr+₹19.0 L (5.51%)Admitted-Finance | ₹3.6 Cr+₹19.0 L (5.51%) | L2 | Admitted-Finance |
| 3 | L3₹3.9 Cr+₹43.2 L (12.6%)Admitted-Finance | ₹3.9 Cr+₹43.2 L (12.6%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S P.N VYAS & SONS L2 | M/S NAGRAJA CONSTRUCTON L3 | Udairaj Infra Power Private Limited L1 |
|---|---|---|---|---|---|---|
| 1.00 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. | 484.37 | Cum | 450 ₹2,17,966.5 | 477.65 ₹2,31,359.33 | 360 ₹1,74,373.2 Lowest |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil | 866.47 | Cum | 150 ₹1,29,970.5 Lowest | 171.59 ₹1,48,677.59 | 260 ₹2,25,282.2 |
| 3.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 1 0 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. Ordinary rock | 126.43 | Cum | 450 ₹56,893.5 | 482.29 ₹60,975.92 | 250 ₹31,607.5 Lowest |
| 4.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. | 692.98 | Cum | 160 ₹1,10,876.8 | 189.47 ₹1,31,298.92 | 150 ₹1,03,947 Lowest |
| 5.00 | Extra for every additional lift of 1 . 5 m or part thereof in excavation I banking excavated or stacked materials.
All kinds of soil | 282.11 | Cum | 115 ₹32,442.65 Lowest | 122.58 ₹34,581.04 | 120 ₹33,853.2 |
| 6.00 | Extra for every additional lift of 1 . 5 m or part thereof in excavation I banking excavated or stacked materials.
Ordinary or hard rock | 82.73 | Cum | 227 ₹18,779.71 | 219.83 ₹18,186.54 | 200 ₹16,546 Lowest |
| 7.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
1 :2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 61.7 | Cum | 7,200 ₹4,44,240 Lowest | 7,616.15 ₹4,69,916.46 | 7,500 ₹4,62,750 |
| 8.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
1 :3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.32 | Cum | 7,295 ₹2,334.4 | 7,051.79 ₹2,256.57 | 7,000 ₹2,240 Lowest |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass
concrete | 102.03 | Sqm | 350 ₹35,710.5 | 379.09 ₹38,678.55 | 300 ₹30,609 Lowest |
| 10.00 | Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and
cantilevers | 389.1 | Sqm | 660 ₹2,56,806 Lowest | 711.88 ₹2,76,992.51 | 700 ₹2,72,370 |
Tender Value
₹4.0 Cr
EMD Value
₹8.0 L
Closing Date
30 May 2025, 3:00 pmClosed
GENERAL MANAGER CONSTRUCTION
GMVN HEAD OFFICE 74/1 RAJPUR ROAD DEHADRUN UTTARAKHAND
DEVELOMPENT OF TIMMERSAIN BASE CAMP AREA SITUTATED AT DISTT. CHAMOLI.
2025_GMVN_83697_1
GMVN- ENGG-TIMBCDE
Open Tender
Miscellaneous Works
Item Rate
548 days
TIMMERSAIN BASE CAMP AREA DISTT. CHAMOLI
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
GENERAL MANAGER CONSTRUCTION
₹8.0 L
DEHRADUN
11 Jun 2025
8 May 2025
30 May 2025
8 May 2025
30 May 2025
16 May 2025
13 May 2025
Amount
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 1 0 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Extra for every additional lift of 1 . 5 m or part thereof in excavation I banking excavated or stacked materials. All kinds of soil
Extra for every additional lift of 1 . 5 m or part thereof in excavation I banking excavated or stacked materials. Ordinary or hard rock
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1 :2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1 :3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1 :4 (1 cement: 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1 :6 (1 cement: 6 coarse sand)
Extra for forming cavity 5 cm to 1 1 . 5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1 :4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1 : 6 : 1 2 (1 cement: 6 coarse sand : 1 2 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1 :6 (1 cement: 6 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing cramps of required size & shape in RCC/ CC I Brick masonry backing with cement mortar 1 :2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 6 mm
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Providing and fixing 2nd class Deodar wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 25 mm thick
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) 35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Second class teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Extra for providing frosted glass panes 4 mm thick (weight not less than 1 0 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 1 0 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I ) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm, 1 :3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing & Fixing decorative high pressure laminated sheet of plain I wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 1 2 mm (average) thick cement mortar 1 :3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I . S . 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 1 2 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
1 2 . 5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0 . 1 6 mm thick fire retardant PVC film on the face side and 1 2 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
French spirit polishing : Two or more coats on new works including a coat of wood filler
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Himalayan stone - exposed face fine dressed with rough backing 50 mm thick ( 450mm x 200mm) (Wall Cladding Stone)
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH GS Size 200 mm, (Ref From DSR 9.81.1)
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH AB Size 100 mm (Ref From DSR 9.81.1)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete Model no- VX Size (200x12) mm (Ref From DSR 9.74.2)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete Model no- VX Size (150x12)mm, (Ref From DSR 9.74.3)
Providing and fixing bright finished brass 250 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Model No-Lever Handle Tango CY with Lock body and cylinder 60mm OSK (Ref From DSR 9.76)
Providing and fixing bright finished brass mortice latch and a pair of lever handles of approved quality with necessary screws etc. complete Model No- Lever Handle Tango DY with BL-3 Latch for bathroom (Ref From DSR 9.76)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (100x75x3) mm, (Ref From DSR 9.72.3)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (125x75x4) mm, (Ref DSR 9.72.1)
Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Brass casement stays (straight peg type ) 200 mm weighing not less than 0.24 kg Size 150 mm (Ref from DSR 9.86.3)
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Model No- DS 02 Size: 140 mm (Ref from DSR 9.82)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (Ref DSR 9.96.1) Sliding Bolt (300x16) mm, EX-02
Providing and fixing second class deodar wood hand rail having size of 75 mm x 65 mm with approved decorative shape etc
Providing and fixing 2nd class Deodar wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.25 mm thick
Providing, laying and fixing of Deodar Wood as in built runner having size of 100mmX75 mm through out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. It allows providing and applying minimum two coats of approved water base PU polishing complete with required primer / sealer coat, rubbing, sand papering, powdering, etc. to exposed surface complete as per manufacturer specification.
Providing and fixing Deodar Wood ceiling in 25 mm thick 150 mm wide deodar wood plank.
Providing and fixing Deodar Wood Jhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank.
Two or more coats on new works including a coat of wood filler Hydro Oil For Exterior Coating
Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles having multilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/ 8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H. The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Equivalent. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Eingeer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a compete job.
Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to Pattern 2 of IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and plug bend as per specifications; glazed vitreous / Coloured European Water Closet with metropole flush valve, with grouting the CI chair in side the floor/wall, rubber gaskets, connecting PVC 110mm dia soil pipe with PVC coupling, nuts, mounting cistern on WC.,1 No.CPVC connection with brass union nuts CP coated and solid verity heavy duty plastic seat cover as per IS-2548, of approved make; including painting of fittings and brackets, cutting and making good the walls wherever require: etc. complete. The rates including cost and conveyence of all materials, labour, machinery etc. EWC-P with Soft close Seat cover :, Model No: CNS-WHT-959S Metropole flush valve Dual flow : , Model No: FLV-1085NG
Providing and fixing White glazed vitreous Wash Basin Oval Under-Counter, size 560 x 430 x 195 mm dia., with supporting M.S. or C.I. Brackets, necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, Waste coupling 32 mm size full thread with 80 mm height Chrome plated, Bottle trap Chrome plated Basin Mixer necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. OVAL UNDER COUNTER BASIN: . , Model No: FLS-WHT-5701 WASTE COUPLING : . , Model No: ALD-CHR-705 BOTTLE TRAP : . , Model No: ALD-769L300X190 Basin Mixer: . , Model No: FLR-5001B
Providing and fixing 15mm C.P. brass angle valve with C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required. ANGLE VALVE : ., Model No. FLR-5053N BRAIDED HOSE Copper Pipe : ., Model no. ALD-CHR-805B
Providing and fixing in position 15 mm C.P. brass long body bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. BIB COCK : . Continental, Model No: CON-107KN
Providing and fixing of Hand Shower (Health Faucet), with 8mm Dia,1.2Rmt Long pvc Tube and Wall Hook accessories of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. HAND SHOWER : . , Model No: ALD-573
Providing and fixing in position best Indian make toilet recessed type paper holder complete in all respects including cutting and making good the walls etc. TOILET PAPER HOLDER : . , Model No: AHS-1553
Providing & fixing C.P. brass towel ring fixed to rawl plug with C.P. brass screws. TOWEL RING : . Continental, Model No.: ACN-1121BN
Providing and fixing C.P. brass liquid soap container of best quality. LIQUID SOAP CONTAINER: . , Model No: SDR-WHT-DJ0010F
Providing and fixing in position best Indian make C.P. brass twin way QUOTE and hat hooks fixed into wall with C.P. Brass screws and rawlplugs etc. complete including cutting and making good the walls etc. DOUBLE QUOTE HOOKS: ., Model No: -ACN-1161N
Providing and fixing of electrical type water Geyser inclusing all required accessories cutting, chassing and good the same. 6 Litre Insta, Make: . Elena vertical
Providing and fixing of electrical type water Geyser inclusing all required accessories cutting, chassing and good the same. 10 Litre Insta, Make: . Elena vertical
Electrical hand dryer, fully automatic type , cover shall be fabricated in extra heavy duty18 gauge type 304 SS with exposed surfaces satin finished, the unit shall deliver not less than 71 l/sec of hot air and electrical rating shall be 240 V / 1 phase / 50 cycles HAND DRYER : . , Model No: HDR-SSF-AK2803D
Providing and fixing perfume dispenser fixed to wooden cleats with C.P. brass screws complete. Air Purifier: Euronics , Model No: EA-33
Providing and fixing white vitreous china flat back urinal of size 385x325x635mm as per IS-2556 (Part-2) with C.I. hangers and 15mm dia. C.P. spreader,Waste coupling, 32mm dia CP bottle trap and pipe to wall with C.P. flange with Pressmatic Urinal Flush valve with wall Flange etc. complete including cutting and making good the walls wherever required. FLAT BACK LARGE URINAL : . , Model No: URS-WHT-13253N WASTE COUPLING : . ,Model No: ALD-705L130 BOTTLE TRAP : . , Model No: ALD-769L300X190 Pressmatic Urinal Flush : ., Model No: PRS-073
Providing and fixing in position 15 mm C.P. brass bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. BIB COCK : . Fusion , Model No. FUS-29037
Providing, installation, testing and commissioning of 50 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1. The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs, fixing waste pipes to the floor with concrete bedding for full length etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge. (Soil, Waste & Vent Pipe)
Providing, installation, testing and commissioning of 75 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1. The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs, fixing waste pipes to the floor with concrete bedding for full length etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge. (Soil, Waste & Vent Pipe)
Providing, installation, testing and commissioning of 110 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1. The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge. The scope shall be also include Providing and laying 100mm thickness cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) around the pipe etc. complete the job as directed by Engineer in charge. (Soil, Waste & Vent Pipe)
Supply, installation, testing and commissioning of Polypropylene (PP) 110mm x 110mm size P trap with necessary of self cleaning design with water seal with and without vent arm jointing with push fit rubber ring socket fittings complete, as required height riser for basin/ sink/ Urinal drain connection with necessary distance piece of pipe, inlet hopper with two or three inlets fittings to receive waste pipes from fixtures waste and hopper shall be Manufactured from 110 mm dia. up to 600 mm long, etc., cutting chases/ hole in floors/ slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended/ open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing, etc. complete the job as directed by Engineer in charge.
Providing and fixing PTMT grating of Rectangular type with openable circular lid of 150mm nominal size square 100 mm diameter of the inner hinged round grating of approved quality and colour.
Providing and fixing of 125 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge.
Providing and fixing of 180 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge.
Providing and fixing of 315 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge.
Making connection to Sewage water line / existing drain including bracking them in a systematic way with suitable excavation, dewatering, dismantling of the RCC or masonry wall or pipe line, passing the plumbing sewage/ storm/ water line in the existing structure either through masonry or CC and providing suitable "Y" tee to the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions tasting etc. complete.
Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 20 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 25 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 32 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 40 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 50 dia pipe
Supplying, laying/ fixing, testing and commissioning of following 50mm thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required.
Providing and fixing of 25mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 32mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 40mm diameter gun metal gate valve with C.I. wheel of approved quality
Supplying, fixing, testing and commissioning of 50mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified.
Supplying, fixing, testing and commissioning of 65mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified.
Providing and fixing of 65mm diameter gun metal non- return valve (vertical) of approved quality
Supply, Installation, Testing and Commissioning of 25 mm dia. air release valve.
Providing and fixing 25mm dia float valve with pressure type PTMT float valve.
Providing and fixing mosquito proof stainless steel overflow grating for tanks.
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
Supplying and fixing 50mm thick aluminium foil faced resin bonded fibre glass insulation (for polyethylene water storage tank) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cum after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting & butting all joints and laced with GI wire complete and finally covered with one layer of tar felt stuck with hot bitumen as per specifications and as required. (for outdoor applications)
Supply, intallation, Testing and Commisioning of 20mm diameter Garden Hydrant with gun metal Ball Valve, Flexinble hose Connection Provision and all required accessories etc.
Supplying, fitting & fixing of 65mm dia Pressure Reducing Valve set of approved make & best quality having by-pass valve arrangement including of 3 nos isolation valve.
Supply installation, testing and commissioning of drinking water filtration system comparision of multigrade sand filter, activated carbon filter, Ultra-filtration & High penetration Ultraviolet. The scope shall include interconnection piping, valves, instruments & pump system, all other required accessories, pump set is auto operation, including dry run protection,all valve controls, interconnecting piping of suction and discharge header, SS tank/ Pressure tank, control panel IP 55, ON-OFF and Trip Indicating lamps in each incomer and outgoing feeders, adequate NO NC contacts for integrating with Building Automation System(BMS), interlocking arrangement, level controller and other necessary cabeling works etc. complete the job. Capacity: 100LPH
Making connection to Water Supply line / existing tank including breaking them in a systematic way with suitable excavation, dewatering, dismantling of the RCC or masonry wall or pipe line, passing the plumbing water line in the existing structure either through masonry or CC and providing suitable "Y" tee to the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions tasting etc complete.
ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878 Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc.
Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 8way, Double door (IP43, IK09)
Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12way, Double door (IP43, IK09)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door (IP43, IK09)
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 25A
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 32A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A
Supply, installation, testing and commissioning 'B' series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supply, installation, testing and commissioning following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO) (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A. Approved Makes-LEGRAND / SCHNIEDER / SIEMENS / L&T / ABB
Laying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ DWC pipe as required. -Upto 35 sq. mm
Laying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required. -Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 3.5C x 70 Sq.mm. Aluminum XLPE armored cable
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 4C x 10 Sq.mm. CU XLPE armored cable
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 4C x 6 Sq.mm. CU XLPE armored cable
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 4C x 4 Sq.mm. CU XLPE armored cable
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 3C x 16 Sq.mm. CU XLPE armored cable
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 3C x 10 Sq.mm. CU XLPE armored cable
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 3C x 4 Sq.mm. CU XLPE armored cable
Supply, connection, testing and commissioning of heavy duty, medium voltage, XLPE (IS 7098 - PART-II) insulated, Stranded AL / Cu conductor Armoured / Flexible cables as per specification & IS. The cable shall have outer sheeth of XLPE and inner sheath of PVC with stranded AL conductor wherever specified. The cable shall be laid underground in excavated trench / prepared trench / hume pipes when laid outside the building. Cable shall be laid throught preapred trench / cable tray / duct / hume pipe / channel / floor trunks etc when laid inside the building as instructed by PMC/Site Incharge. The scope shall include: 1) Supply of Cables.(With Non Returnable Drums) 2) Delivery of the cables at site. 3) Unloading at site store. 4) Shifting of cable from site store to place of installation. 5) Connection of cable with proper tagging as specified ni specifications. 6) Supply & fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely. 7) Earthing the glands and armouring with earthing clamp and jumper and also connecting to common earth bar. 8) Testing of insulation and continuity of cable and submission of reports to the client's representative. 9) To prepare submission drawing and to take approval of consultant at each stage. 10) To prepare & submit as-built drawing and handing over document to end user. 11) Rate shall be inclusive of route markers at 15mtr intervals 12) Each run of cable to be tested with 1KV meggar 13) Proper cables tags of Aluminium shall be made and feeder shall be written. Approved Makes- FINOLEX / RAVIN / POLYCAB / RR KABEL / GEMSCAB /KEI / HAVELLS - 3C x 2.5 Sq.mm. CU XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -3.5C x 70 Sq.mm. Aluminum XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -4C x 10 Sq.mm. CU XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -4C x 6 Sq.mm. CU XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -4C x 4 Sq.mm. CU XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -3C x 16 Sq.mm. CU XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -3C x 10 Sq.mm. CU XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -3C x 4 Sq.mm. CU XLPE armored cable
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI /Equivalent or approve by E/I -3C x 2.5 Sq.mm. CU XLPE armored cable
Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required- Group C Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E), Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E), Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E), Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E), Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
power plug point modular type accessories: Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E), Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E), Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E), Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E), Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E), Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E), Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points. Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FRLS PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring. Wire Size for Lighting circuit Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board) From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E), Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E), Cost of MCB shall not be considered in point rate.Wherever sensor require, wiring to be done accordingly. Making of zari in wall using only electric cutter and finishing the surface as it was. earthing of fitting electrical connection to the fixture from the out let point/ceiling rose. Wire breaded PVC flexible conduit from ceiling point to light fixture. Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
Brass holder Supplying and flxing brass batten/angle holder including connection etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450mm sweep.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supply, installation, testing and commissioning of following sizes of Heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
Supply, installation, testing and commissioning of following sizes of Heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32mm
S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner. Approved Makes-OBO/ JEFF/ JMV
20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures: 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make BN021C LED20S PSU CW GR S2 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies/ Equivalent
18W, 2000 Lumen Recess mounted LED Down light fixtures: Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Recess mounted LED Down light fixtures equivalent to Philips make DN296B LED15S-6500 PSU WH complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies / Equivalent
WALL MOUNTED LED LIGHT : (MIRROR LIGHT) Supply, Installation, assembling, connection, testing & commissioning of wall mounted Supply, Installation, assembling, connection, testing & commissioning of wall mounted Mirror LED Light suitable for 12W luminaire along with all other necessary accessories. Equivalent to Philips/BN021CLED12S PSU CW GR/02. IP20. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Makes-Philips/Wipro/K-Lite/Lighting Technologies
LED BULK HEAD LIGHT FIXTURE: Supply, laying, connection and testing of LED bulk head lighting with all necessary details. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Makes-Neri/ Bega / DW Windor
Weather Proof Downlighter : Supply of CEILING LED Fixture -LED 12W,LED Electronic Driver which offers Protection against Short Circuit, Over- Voltage & Over- Current, IP 66 protection,CRI > 70,voltage input AC100-240V.Body-Die-casting and Extruded aluminium Body with Surface Anti-ageing electrostatic spray processing & screen. Body colour-RAL 9005 Matt ,Dimension-126mm(Dia.)x138mm(H),Weight-0.75kgs. Estimated Lifetime-L70 @ 50,000hours minimum. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make -Neri/ Bega / DW Windor
Supply of Weather Proof Downlighter (On Roof Chajja) Recessed Celiing Light - 10W,800lm,IP65,3000K, Dimension 100X80mm, Height 80mm Diameter is 100mm, Weight is 0.5kg, Fixing Suitable for ceiling-mounted recessed installation. Fixture is made of Die Cast Aluminium, Powder Coated, LED is COB, Inbuilt driver, Input AC 240V, 50/60Hz * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - Neri/ Bega / DW Windor
Up & Down Light Supply of 2X10 W LED Up down light suitable for wall mounting , BIS approved , Body made of pressure Die cast aluminium , proper heat sink should be designed for better heat dessipation , The diffuser should be clear toughned glass with IK08 protection . The luminaire is provided with surge protection of 4 KV . Electronic driver having power factor>0.95, THD <15 % and input voltage range from 150-270V AC at 50Hz. Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700 as per ANSI,LED Make CREE/Osram/Samsung with LM80 report to be submitted at the time of Supply , life of 50000 burning hours with 70% of initial lumens maintained.Ambient Operating Temperature is -10 Deg. to 50 Deg. Luminaire should Maintain Ingress Protection of IP65 for better weather proofing. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make -Neri/ Bega / DW Windor along with all other necessary accessories.
WALL MOUNT SURFACE DOWN OR UP LIGHTER/WALL WASHER Supply, Installation, assembling, connection, testing & commissioning of Wall Mount/ Wall washer Lights. LED FIXTURE - equivalent to NERI/NWL- 17S/13 * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - Neri/ Bega / DW Windor
Landscape Bollard Supply, laying, connection and testing of Landscape Bollards 15Watts Bollard LED, IP66, 800/100mm. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - Neri/ Bega / DW Windor
FIXTURE - 40-45W Power Module LED: Supply, Installation, assembling, connection, testing & commissioning of post top light fixture equivalent to LED FIXTURE - 40-45W Power Module LED, -MOUNTED AT 4 METER HEIGHT POST TOP POLE :it's - Upper frame made in die-cast and sheet aluminium (thickness: 2.5mm), with threaded coupling G3/4" for fixing,Bottom frame with ring made in die-cast aluminium and two arms made in hotgalvanized steel, with flange for fixing equipped of a hole (diam. 28 mm) .Gasket between the upper and bottom frames.Painted with polyester powder coating in Metallaic Grey (As per Architectural requirement). IP Rating - IP 66.Height –690mm, Dia - 550mm, Weight - 11.5Kg, Area Exposed to Wind(S) - 0.105 m2. Power LED's Module (with CREE/NICHIA/OSRAM/SEOUL SMD type LED’s with ESD=>8kV & Ceramic package are accepted. LED manufacturers tech sheet with buying documents should be submitted for verification. Individual LED's Minimum Luminous Flux (lm) is 139lm @ 350 mA (@ 85 °C) same should be supported by LED manufacturer's tech sheet) in compliance with IEC 62031(supporting type test report should be submitted), on Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 1.5kv(an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens (Polycarbonate), UV Resistant & Shock Resistance IK10.LM80 Reported LED Lifetime is L90@ 50,000hours minimum.(same should be supported by LM 80 report from NVLAP accredited lab) & Estimated LED Lifetime is L80 @ 100,000 hours(Ta-25°C) minimum..LM 80 report & TM 21 calculation should be submitted to support the same.The Light fixture shall be in compliance with IEC 60598-2-3; IEC 60598-1.(Supporting Test Report from NABL accredited Laboratory should be submitted) .LM79 report should be submitted from NABL accredited Laboratory. * Colour of light fixture shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - Neri/ Bega / DW Windor
Supply, Installation, assembling, connection, testing & commissioning of ARCHITECTURAL POLE (FOR POST TOP LIGHTING) 3.3M height Pole (Total height of the pole is 4m including post top) Made in combination of hot dip galvanised mild steel pipe sections 114mm dia. & 140mm dia. Arch. cast iron Base design starts with min 322mm Dia. ring, radially tapers to 140 mm for a height of min 235 mm matching to the drawing. Total weight of the base is min 15 Kgs. Decorative Ring-1 (140/114mm dia. – min 3kgs.) & Top Ring (weight- 3kgs.) are made of cast iron. Entire pole shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box (Concealed) to fix 32A connectors and 6A MCB (to terminate incoming and outgoing armoured cables with glands and lulgs), at the bottom -the inbuilt box should have a flush door of suitable size. The decorative pedastal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole design. Pole & it's parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint- customised colour Metallaic Grey (As per Architectural requirement). Adequate size cutout with opeanable hinged door should be provided on pole with necessary gasket to ensure water tight arrangement for pulling cables and installation of mcb, connectors etc, complete in all respect as per requirement and instruction of engineer in charge. Scope also includes necessary foundation, cable termination, earthing as per requirement, cable entry pipes, 3 core round flexible wire from junction box to light fixture etc. all require to complete job. * Colour of Pole shall be as per Architectural requirements. * Contractor to submit samples for Approval before ordering the fixture. Approved Make - Neri/ Bega / DW Windor
Supply, Transportation, Installation, testing and commissioning of of exhuast fan (450mm) Approved Makes-Havells/Usha/Almonard / Equivalent
Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1006 G/OBO/CAPE
Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1610 G/OBO/CAPE
Supply, Transportation, Installation, testing and commissioning of IP 67 weather proof Outdoor type junction boxes with terminal block/connector. Equivalent to Hensel catalogue no KF 1616 G/OBO/CAPE
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal)
SITC of 315 mm dia (OD-315 mm & ID-271 mm nominal)
Providing & Laying of HDPE Pipe 32mm PE-80,PN6 direct in ground; to be laid 75-100cm below the ground level for drawing of cables including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering,or G.I. conduit 32 mm dia( Heavy Duty) with concrete block 15cm X 15cm 1:2:4 with complete curing with splicing complete in all respect complete in all respect. Make: Jain/Dutron/Supreme/reliance
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends “ ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends “ ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. -150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. -300 mm width X 50 mm depth X 1.6 mm thickness
Supply, installation, testing and commissioning of Outdoor Cat6 cable. Make:- SYSTEMAX / CALIPLAST / DURANET / PANDUIT / Equivalent
Supply, Installation,testing and commissioning of 8Port POE Network Switch to provide Power and Data Communication for mentioned Camera. With 1 G SFP Module. Approved Makes- CISCO / HP / SIEMENS / R&M / NetGear / Equivalent
Supply, Installation, Testing & Commissiong of IP MFZ BULLET CAMERA Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Bullet Camera, 1/2.8" CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.7 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. Cyber Security PCI-DSS or equivalent Certified. Approved Makes- oneywell/ BOSCH/Hikvision/ Pelco/Axis/ Equivalent or approved by E/I
Supply, Installation, Testing & Commissioning of 8-channel network video recorder (NVR), Real-time recording: Up to 16 channels 1080P @ 4Mbps, Operating System LINUX, H.265, H.264 high quality decoding, RAID-0/1/5/6/10 support, motion detection, 3 USB 2.0 ports, USB storage device, 2 RJ-45 port, 1 RS-232, Hot swap, 2 bay HDDs, Support ONVIF Profile S, HTTP/HTTPS, TCP/IP, RTSP, UDP, NTP, HTTPS, DHCP, IP Search protocols can support Approved Makes- Bosch/Honeywell/Axis/Pelco/ Equivalent
Supply, Installation, Testing and Commissioning of Wall mounted 9U Rack along with power sockets strips and all other require components & acceessories to mount all the equipments for satisfactory job. Approved Makes- Rittal/Panduit/Valrack/Netrack / Equivalent
Supply, Installation, Testing and Commissioning of Junction Box(570X280X215) and all other require components & acceessories to mount all the equipments for satisfactory job. Approved Makes- 3C3/Hensel / Equivalent or approved by E/I
Supply, Installation, Testing and Commissioning of 6 single mode fiber optic cables (9/125 µm) with all necessary accessories to comply the installation. Approved Makes- SYSTEMAX / CALIPLAST / DURANET / PANDUIT /R&M / equivalent or approved make 3C3
Supply, Installation, Testing and Commissioning of 12 LC Port Loaded LIU SM with all necessary accessories to comply the installation. Approved Makes- Honeywell / Panduit / R & M / 3C3 / Equivalent
Supply, Installation, Testing and Commissioning of 06 LC Port Loaded LIU SM DinRail Type with all necessary accessories to comply the installation. Approved Makes- Honeywell / Panduit / R & M / 3C3
Supply, Installation, Testing and Commissioning of LC-LC SM Patch Cord 3 Mtr with all necessary accessories to comply the installation. Approved Makes- Honeywell / Panduit / R & M / 3C3
Supply, Installation, Testing and Commissioning of SC-LC SM Patch Cord 3 Mtr with all necessary accessories to comply the installation. Approved Makes- Honeywell / Panduit / R & M / 3C3
Supply, Installation, Testing and Commissioning of I/O User end and all necessary accessories to comply the installation.
Supply, Installation, Testing and Commissioning of Weather Proof Back Box for CCTV(120X120X75) with all necessary accessories to comply the installation. Approved Makes- Honeywell / Panduit / R & M / 3C3 / Equivalent
Hard Drive Disk: SITC of Enterprise surveilliance HDD 8 TB for 60 days storage at D1 resolultion. Approved Makes- Bosch/Honeywell/Axis/Pelco
Supply, Installation, Testing and Commissioning of industrial type 32" LED Display for 24x7 runningg (ON), 1920 X 1080 Resolution, 450 CD/M2 Brightness, Wall Mounting Bracket. Approved Makes- SAMSUNG / SONY / LG / Equivalent
Supply, Installation, Testing and Commissioning of 1 mtr. Cat 6 Patch cord. Approved Makes- Honeywell / Panduit / R & M / 3C3 / Equivalent
Supply, Installation, Testing and Commissioning of 24 Port fully loaded patch panel Approved Makes- Honeywell / Panduit / R & M / 3C3 / Equivalent
Any other Item Not included above but required to complete the Job:-
Supply installation Testing and commissioning of 2 KVA (SINGLE PHASE) on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / Single phase output with minimum 15 minutes battery back up of each UPS. Approved Makes-Eaton, Neumeric, APC / equivalent make or approved by E/I
Liaison with Local Electricity board for Permanent Electrical Power & DG set installation(if any DG set require) & Getting Approval from Licensee, Electrical Inspector - IM & E Dept. The scope includes to get the required power including DG Sets(if any DG set require) complete with providing necessary drg /document/ arranging visit etc from requirement of statutory authority. The payment towards official payment shall be reimbursed against receipt of such payment.
M/S P.N VYAS & SONS (BID ID -384521)
M/S NAGRAJA CONSTRUCTON (BID ID -384833)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
timDC1.pdf
Tender Documents • 2.00 MB
BOQ_99581.xls
BOQ • 0.56 MB
Tenderdocument.pdf
Tender Documents • 2.00 MB
BOQ.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .