Loading…
Loading…
Tender Value
₹1.9 L
EMD Value
₹4,788
Closing Date
9 Jul 2026, 6:00 pm4d left
Assistant Executive Engineer
o/o The Assistant Executive Engineer PWD Electrical Sub Division Chembukavu,Thrissur-20
GENERAL-Maintenance contract for servicing and replacing the damaged items of Split Air Conditioning units in the various PWD rest houses at Irinjalakuda Kodungallur Chalakudy-works Electrical AC Work
2026_PWD_858706_1
ESDT(ET)27/AEE/26-27
Open Tender
Electrical Works
365 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
₹4,788
2 Jul 2026
2 Jul 2026
13 Jul 2026
2 Jul 2026
9 Jul 2026
2 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1AC AMC | |||||
| 1.001 | OD345510/2025-2026:Annual Maintenance and servicing of 1TR/ 2TR/3 TR, 240/415V Vertical and Wall/ Floor Mounting type Split /Ductable split Air Conditioner Units covering all routine and preventive maintenance, attending to all breakdowns and rectifying the defects if any (excluding the cost of spare). The cleaning and servicing of IDU and ODU includes 1no. water servicing using chemicals, water pump etc. and 3 nos. Air servicing using cleaning materials and pressure air pump etc. The operating status of the units should be regularly monitored and intimated to the department staff in charge and the Air conditioner Units should be maintained in proper working condition through out the period of contract | - | each | 2,226.09 | - |
| 1.002 | OD345524/2025-2026:Charges for filling sufficient quantity of Freon 22/32/410 A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including brezing and make the compressor in good working condition for the following. 1TR/1.5TR/2TR/3TR | - | kilogram | 1,007.43 | - |
| 1.003 | OD345518/2025-2026:Supply and renewing PCB suitable for 2TR/1.5TR/1TR A/C unit in the place of defective one and make the unit in perfect working condition.. | - | each | 4,197.85 | - |
| 1.004 | OD345506/2025-2026:Dismantled the defective PCB, rectify the defect, re-install the same and make the unit in perfect working condition. :- 1TR/1,5TR/2TR/3TR | - | each | 3,718.46 | - |
| 1.005 | OD345523/2025-2026:Supply and renewing sensor suitable for 1TR/1.5TR/2TR/3TR in the place of defective one. | - | each | 472.1 | - |
| 1.006 | OD345509/2025-2026:Supply and renewing 2.5/4 mfd capacitor suitable for out door fan motor of 1TR/1.5TR/2TR in the place defective one. | - | each | 95.53 | - |
| 1.007 | OD345512/2025-2026:Supply and renewing 36/45/50 mfd capacitor suitable for compressor motor of 1TR/1.5TR/2TR in the place defective one. | - | each | 503.14 | - |
| 1.008 | OD345519/2025-2026:Supply and renewing Cu flare nut suitable for 1TR/1.5TR/2TR/3TR in the place of defective one | - | each | 424.48 | - |
| 1.009 | OD345527/2025-2026:Supply and renewing Indoor Blower Motor suitable for 3TR/2TR/1.5TR/1TR in the place of defective one and make the unit in perfect working condition | - | each | 3,662.81 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.14 MB
Tendernotice_2.pdf
PDF • 0.05 MB
Tendernotice_3.pdf
PDF • 0.20 MB
Tendernotice_4.pdf
PDF • 0.21 MB
Tendernotice_5.pdf
PDF • 0.03 MB
Tendernotice_6.pdf
PDF • 0.27 MB
BOQ_1451779.xls
BOQ • 0.34 MB
NIT.pdf
Tender Documents • 0.03 MB
SBD.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid