Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.0 LAccepted-AOC 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹26.1 L+₹1.1 L (4.41%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L-2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L-3₹26.2 L+₹1.2 L (4.80%)Rejected-Finance 24 C VAIBHAV SUNCITY VISTAR BAREILLY UP 243001 | BAREILLY | UTTAR PRADESH | 243001 | L-3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L-4₹26.7 L+₹1.8 L (7.06%)Rejected-Finance 37 B MODEL TOWN NEAR HARI MANDIR BAREILLY UP 243001 | BAREILLY | UTTAR PRADESH | 243001 | L-4 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
Refer Docs
EMD Value
₹61,200
Closing Date
9 Dec 2020, 6:00 pmClosed
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
SR LT PANEL BOARD AND DOZING PLANT, SR WATER SUPPLY DISTRIBUTION NETWORK, PO CHLORINE PRESSURE FEED PUMP AND CONNECTED ACCESSORIES AND PO MONO BLOCK PUMP SETS FOR YODHA BLOCK AT AF STATION BAREILLY.
2020_MES_385101_2
8558 / E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
Bareilly
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹61,200
Yes
8 Jan 2021
16 Nov 2020
11 Dec 2020
16 Nov 2020
9 Dec 2020
23 Nov 2020
16 Nov 2020 - 23 Nov 2020
Amount
Supply, installation, connecting, commissioning and testing as in replacement of old unserviceable one, chemical dosing system plunger type suitable to inject solution upto 25 LPH comprising of dosing pump coupled with 3 phase, 415 volts, electric motor of 0.50 HP capacity 1440 RPM assembled with agitator in one motor for agitator with SS sweep blade alongwith FRP coated FRP tank of capacity 150 Litres complete as one single unit mounted on heavy duty mild steel fabricated frame duly painted with anti-corrosive paint with and including chemical grade PVC NRV, 3 phase suitable capacity starter complete all as specified and directed. NOTE: - The contractor must submit the certificate of compliance i.e. Test Certificate and Purchase Voucher as obtained from the manufacturers.
Design, supply, erection, testing and commissioning as in replacement of old unserviceable one, indoor type LT panel, overall size not less than 1050 mm wide X 800 mm High X 400 mm Deep, comprising mild steel channel Base Frame mounted (to be mounted on the 3 sides covered brick pedestal of height 900 mm above ground level), suitable for 3 phase, 4 wire, 415 volts AC supply, having 4 Nos. aluminium bus bars of rating 250 Ampere, provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables and 4 way ebonite cable connector (rating 32 Ampere) for termination of outgoing cables for MCBs.
The LT Panel shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of LT Panel and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL-7032 (SIEMENS GRAY). The LT Panel shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection shall not be less than IP-54 and general construction conforming to IS-13947. The LT Panel shall be made out of 2.00 mm thick CRCA mild steel sheet and 2.00 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The LT Panel shall be comprising of the following: -
(A) PROVISION FOR CABLE ENTRY The provision of cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. (B) BUS BARS AND INTERNAL CONNECTIONS The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos. Aluminium bus bars of rating 250 Ampere. All internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25 mm X 6 mm. (C) CONTROL WIRING All control wiring shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.
(D) INCOMING 4 pole MCCB (with panel mounted rotary handle) having breaking capacity of 16 KA, fixed magnetic and fixed thermal setting (100% - 80%) of rating 160 Ampere- 01 No. MAKE- LEGRAND or SCHNEIDER or ABB. (E) OUTGOING (i) MCCB 63 Ampere, 16 KA, 3 Pole Adjustable thermal (100% - 80%) and fixed magnetic setting- 02 Nos. MAKE- LEGRAND or SCHNEIDER or ABB. (ii) Fully automatic star delta strater in built in panel 415 volts, 50 Hz with over load protection as required for motor of 45 HP, 3 Phase. MAKE- L&T, Jyoti, Siemens.
NOTE: - All incoming and outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the LT panel. All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. All the inner / outer doors should have locking facility through castle locks. Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. The dimension of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. The thickness of mild steel sheet for outer shell and canopy shall be of 2.00 mm and inner doors and partitions shall be of 2.00 mm. The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
M & L for replacement of old defective earthing by providing new earthing comprising of galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth strip of size 32 X 6 mm by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point of size 75 X 75 X 25 mm including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 75 mm both ways center to center with suitable lifting handle made of 12 mm dia mild steel round bar to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. NOTE: - COST OF GI EARTH STRIP AND GI PROTECTION PIPE UPTO 7.50 METRES SHALL DEEMED INCLUDED IN THE UNIT RATE OF THIS ITEM. ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation, trenches for laying of water tubing or cables etc. and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for making horizontal hole by mechanical Boring under hard standing, pavements or roads for insertion of CI / GI pipes 25 to 200 mm bore and making good the disturbed surface complete all as specified and as directed.
Taking up cast iron water mains (including all fittings) with spigot and socketed ends and lead joints including burning out joints complete all as specified and directed for the following sizes: -
(a) CI pipe of 150 mm bore.
(b) CI pipe of 100 mm bore.
(c) CI pipe of 80 mm bore.
Relaying of cast iron pipe with spigot and socketed ends after cleaning of internal surface of serviceable pipe with wire brushes and cleaning the complete pipe with clear water throughly complete all as specified and directed for the following sizes: - NOTE: - Old CI pipes obtained from taking up or down shall be used under these items.
(a) CI pipe of 150 mm bore.
(b) CI pipe of 100 mm bore.
(c) CI pipe of 80 mm bore.
Supply and laying in trenches ductile iron (DI) pressure pipe with spigot and socketed ends, centrally cast, class K-7 conforming to IS-8329 (2000) with internal metallic zinc coating and external black bituminous coating suitable for push on joint (Tyton) with and including necessary jointing material complete all as specified and directed for the following sizes: - NOTE: - Cost of joints and jointing material shall be deemed included in the unit rate of this item.
(a) DI pipe of 150 mm bore.
(b) DI pipe of 100 mm bore.
S & F of 80 mm bore cast iron pipe with spigot and socket ends, centrifugally cast, class LA, suitable for lead joints, in any length, laid in trenches complete all as specified and directed.
S & F of cast iron fittings such as bend (any type, radius and angle) tapper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch, ‘Y’ junction, double branch, cross (all socket or socket and spigot) collar, caps and plugs suitable for upto 150 mm bore cast iron pipe complete all as specified and directed.
S & F of cast iron fittings such as bend (any type, radius and angle) tapper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch, ‘Y’ junction, double branch, cross (all ends flanged) collar, caps and plugs suitable for upto 150 mm bore cast iron pipe complete all as specified and directed.
S & F of cast iron fittings such as bend (any type, radius and angle) tapper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch, ‘Y’ junction, double branch, cross (one end flanged and other end socket or socket and spigot) collar, caps and plugs suitable for upto 150 mm bore cast iron pipe complete all as specified and directed.
M & L for run lead joint suitable for cast iron pipe spigot and socketed joint including lead, cocking spun yarn etc. complete all as specified and directed for following sizes: -
(a) Cast Iron pipe 150 mm bore.
(b) Cast Iron pipe 100 mm bore.
(c) Cast Iron pipe 80 mm bore.
Run lead joint by using old lead obtained from dismantling of item No. 8(a) to 8(c) hereinbefore suitable for cast iron pipe spigot and socketed joint including providing new cocking spun yarn etc. complete all as specified and directed for following sizes: -
(a) Cast Iron pipe 150 mm bore.
(b) Cast Iron pipe 100 mm bore.
(c) Cast Iron pipe 80 mm bore.
M & L as in replacement for 3 mm thick rubber or fiber board gasket to make the joint leak proof with and including provision of mild steel nut-bolts, washers as required at site of as per existing size complete all as specified and directed for following sizes: -
(a) Joint of 80 mm bore pipe line.
(b) Joint of 100 mm bore pipe line.
(c) Joint of 150 mm bore pipe line.
Supply, installation, commissioning and testing of 150 mm size cast iron sluice valve, class-I, both ends flanged & drilled conforming to IS-14846 (2000), PN-1.6, with gun metal or stainless steel spindle with and including all accessories such as nut-bolts, washers & fibre / rubber gasket as required at site including taking out old unserviceable sluice valve complete all as specified and directed.
Supply, installation, commissioning and testing of 100 mm size cast iron sluice valve, class-I, both ends flanged & drilled conforming to IS-14846 (2000), PN-1.6, with gun metal or stainless steel spindle with and including all accessories such as nut-bolts, washers & fibre / rubber gasket as required at site including taking out old unserviceable sluice valve complete all as specified and directed.
Supply, installation, commissioning and testing of 80 mm size cast iron sluice valve, class-I, both ends flanged & drilled conforming to IS-14846 (2000), PN-1.6, with gun metal or stainless steel spindle with and including all accessories such as nut-bolts, washers & fibre / rubber gasket as required at site including taking out old unserviceable sluice valve complete all as specified and directed.
Supply, installation, commissioning and testing as in replacement of old unserviceable one, 100 mm bore cast iron air release valve having 02 Nos. air outlets of 50 mm bore, suitable for fixing up in DI water supply mains complete all as specified and directed.
Supply, installation, commissioning and testing as in replacement of old unserviceable one, 150 mm bore cast iron air release valve having 02 Nos. air outlets of 50 mm bore, suitable for fixing up in DI water supply mains complete all as specified and directed.
Dismantling of old unserviceable, broken, damaged valve pit from its position and M & L for construction of brick masonry valve pit of size 1200 mm X 1200 mm X 1200 mm deep (Internal dimensions) with brick work using old size fly-ash bricks built in cement mortar 1:4 and 10 mm thick rendering on internal and 15 mm thick on exposed external surfaces, 50 mm X 50 mm X 6 mm mild steel angle iron frame, 3.15 mm thick mild steel sheet cover with appropriate size lifting handles and locking arrangement and 01 No. 50 mm size 4 levers lock with keys in duplicate make- Harison / Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing No. CEAF / TD / EM / 01 and as directed.
Taking up or down steel water tubing and connection from trenches or floor alongwith gate valve, stop valve if any, including segregation of serviceable pipes complete all as specified and directed for the following sizes: -
(a) GI pipe of 80 mm bore.
(b) GI pipe of 50 mm bore.
(c) GI pipe of 40 mm bore.
(d) GI pipe of 25 mm bore.
S & F of galvanised iron water tubing medium grade with and including all GI fittings as required at site, laid in trenches complete all as specified and directed for the following sizes: -
(a) GI pipe of 80 mm bore.
(b) GI pipe of 50 mm bore.
(c) GI pipe of 40 mm bore.
(d) GI pipe of 25 mm bore.
Relaying of galvaised iron water tubing and connection at any position including cleaning of old pipes (Internally and Externally complete) with and including provision of new GI fittings as required at site complete all as specified and directed for the following sizes: - NOTE: - Old GI pipes obtained from taking up or down shall be used under these items.
(a) GI pipe of 80 mm bore.
(b) GI pipe of 50 mm bore.
(c) GI pipe of 40 mm bore.
(d) GI pipe of 25 mm bore.
S & F of gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe with and including taking down old unserviceable one complete all as specified and directed for the following sizes: -
(a) Gate valve of 50 mm size.
(b) Gate valve of 40 mm size.
(c) Gate valve of 25 mm size.
Supply, installation, connecting, commissioning and testing of chemical dosing system plunger type suitable to inject solution upto 25 LPH comprising of dosing pump coupled with 3 phase, 415 volts, electric motor of 0.50 HP capacity 1440 RPM assembled with agitator in one motor for agitator with SS sweep blade alongwith FRP coated FRP tank of capacity 150 Litres complete as one single unit mounted on heavy duty mild steel fabricated frame duly painted with anti-corrosive paint with and including chemical grade PVC NRV, 3 phase suitable capacity starter complete all as specified and directed. NOTE: - The contractor must submit the certificate of compliance i.e. Test Certificate and Purchase Voucher as obtained from the manufacturers.
S & F of 15 mm bore UPVC pipe having pressure rating 10 Kg per Sqcm fixed to wall with necessary fitting and fixing arrangements complete all as specified and directed.
Supply, installation, commissioning and testing of 3 HP capacity monoblock pumping set, discharge capacity 972 Litres per minutes at 10 metre head suitable for 415 volts, 3 phase supply complete all as specified and directed.
S & F of gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed for the following sizes: -
(a) Gate valve of 50 mm size.
(b) Gate valve of 40 mm size.
Supply, installation, commissioning and testing of 40 mm bore brass Non Return valve (Reflex Valve) screwed both ends suitable for jointing with socket or union complete all as specified and directed.
Supply, installation, commissioning and testing of factory made LT panel box, outdoor cubical type, double door, floor mounted, made out of 3.15 mm thick powder coated mild steel sheet for outer cover and 1.60 mm thick powder coated mild steel sheet for internal partitions, having aluminum bus bar 200 Ampere for phases and neutral, mounted on epoxy based post insulators duly drilled hole for connections, provision of air vent, self moulded type duly enclosed over 75 X 75 X 6 mm angle iron frame duly grouted in foundation made of PCC 1:2:4 type B-1. Panel shall be suitable for 415 Volts 3 phase 4 wire system 50 Hz with and including necessary internal wiring with suitable size PVC insulated copper conductor cable and copper lugs comprising of the following accessories duly fitted in panel box:-
S & F of 1100 volts grade heavy duty 03 single core 10.00 Sqmm size PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC Conduit medium grade not less than 25 mm size with and including its all accessories & fittings, fixed on surface complete all as specified and directed.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade, ISI marked, 10 Sqmm 4 core, LT cable (heavy duty), XLPE insulated served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed with stranded aluminium conductor cable including commissioning and testing complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in soft / loose soil, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
M & L for providing plain cement concrete, type B-2, 1:2:4 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161(1979) grade St-240 complete all as specified and directed.
S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Grade E-250) quality-A complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
M & L for filling of moorum or red bajri under floors or paving, laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate as in hard standing / apron and the like etc. with and including all necessary form work for lateral support complete all as specified and directed.
M & L for construction of brick masonry valve pit of size 1200 mm X 1200 mm X 1200 mm deep (Internal dimensions) with brick work using old size fly-ash bricks built in cement mortar 1:4 and 10 mm thick rendering on internal and 15 mm thick on exposed external surfaces, 50 mm X 50 mm X 6 mm mild steel angle iron frame, 3.15 mm thick mild steel sheet cover with appropriate size lifting handles and locking arrangement and 01 No. 50 mm size 4 levers lock with keys in duplicate make- Harison / Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing No. CEAF / TD / EM / 01 and as directed.
M & L for laying of course sand free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required complete all as specified and directed.
M & L for laying brick as in protection covers over cables using well brunt sub class 'B' old size bricks in trenches over sand cushioning complete all as specified and directed.
Mohit Enterprises
SHRI SIDHI VINAYAK INFRASTRUCTURE DEVELOPERS
MOHINDER SINGH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .