Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC | ₹25.5 L Quoted ₹26.7 L | L1 | Accepted-AOC Being L1 biddder |
| 2 | L2₹29.2 L+₹2.5 L (9.37%)Rejected-Finance | ₹29.2 L+₹2.5 L (9.37%) | L2 | Rejected-Finance Being not L1 bidder |
| 3 | L3₹31.0 L+₹4.3 L (16.1%)Rejected-Finance | ₹31.0 L+₹4.3 L (16.1%) | L3 | Rejected-Finance Being not L1 bidder |
| 4 | L4₹35.9 L+₹9.2 L (34.5%)Rejected-Finance MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | ₹35.9 L+₹9.2 L (34.5%) | L4 | Rejected-Finance Being not L1 bidder |
| 5 | L5₹38.1 L+₹11.4 L (42.6%)Rejected-Finance | ₹38.1 L+₹11.4 L (42.6%) | L5 | Rejected-Finance Being not L1 bidder |
| Sl No | Description | Qty | Unit | M/s NATIONAL ENGINEERING CONSTRUCTIONS CO L1 | NJ ENTERPRISES L2 | S R CONSTRUCTIONS L3 | PNR CONSTRUCTIONS L5 | jyothi constructions L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00NOTES / INSTRUCTIONS FOR STRICT COMPLIANCE :- (a) The contractor shall obtain sample approval for all materials incorporating in the work as per condition 10 of IAFW-2249 and Special Condition 11 of tender document mentioned here-in-after. (b) The Engineer-in-charge may direct the contractor in writing to procure and deposit up to 50% quantity of the material with in 30 days from the date of commencment as required at site out of quantity to complete the scope of work. Remaining 50% shall be procured as per site requirement during progress of work.The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material to the store of concerned subdivision within 30 days from the receipt of written direction. Failing which contractor shall liable to pay a penal recovery of Rs. 5000/- per week, levied on the dues of contractor, subject to maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as Electrician / FGM / Technician etc., readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge. (e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery etc., as per site requirement. | ||||||||
| 2.00 | M&L for overhauling / repair of 11KV vacuum circuit breaker (VCB) comprising of repairs, complete overhauling / servicing, cleaning of all parts, adjusting contacts, checking epoxy body, drive insulator, spring charge mechanism, locking arrangements tripping coil circuits (closed / open) etc, checking all mechanical operations supporting insulators bush trolley auxiliary contact. make female contact and check all wiring, carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repair / overhauling complete all as specified and as directed.
Note:- (i) The servicing includes for busbar duct chamber, cable alleys and connecting accessories
(ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning.
(iii) Major spares like Breaker bushings, vacuum interrupter assly, busbar spout, busbar spout connections, circuit spout, circuit spout connections, buffer fixed contacts, moving contacts, tank assly, barriers, solenoid spares, dependent, spring mechanism / motor mechanism, trip unit etc will be measured and paid separately under relevant items. However the rate quoted shall be deemed to include for any other minor spares requiring replacement.
(iv) The servicing shall be carried out by auhtorised service provider as specified and directed by Engr-in-Charge. | 9 | Each Job | 4,000 ₹36,000 Lowest | 6,000 ₹54,000 | 6,000 ₹54,000 | 7,500 ₹67,500 | 7,000 ₹63,000 |
| 3.00 | M&L for Overhauling / Repair of 11 KV VCB Panel with cleaning of all parts, checking & cleaning circuit all busbar spout bushings, CT/PT spout bushings, Busbar, cleaning of CT and PT, checking all wiring & rectifying Wiring faults, cleaning metering chamber, applying mono plast compound at busbar joints, fixing up issues with measuring instruments etc including minor item such as nuts, bolts, copper wires, HT insulation tapes etc required for repair complete all as specified and directed.
Note : The testing / inspecting Engineer shall be minimum a State Govt Licence holder or any OEM authorised License holder. | 9 | Each Job | 2,000 ₹18,000 Lowest | 3,000 ₹27,000 | 3,000 ₹27,000 | 6,500 ₹58,500 | 4,500 ₹40,500 |
| 4.00 | S&F busbar / CT supporting insulator for 11 KV VCB panel of rating 400 to 1250A, 25KA, suitable for 11kV VCB panel including taking down existing un-serviceable busbar / CT supporting insulator complete all as specified and as directed. | 6 | Each | 1,500 ₹9,000 | 12,000 ₹72,000 | 2,000 ₹12,000 | 1,250 ₹7,500 | 500 ₹3,000 Lowest |
| 5.00 | S&F spring charging universal motor with gear box 220V AC/DC of rating 400 to 1250A suitable for 11kV VCB including taking down existing un-serviceable spring charging universal motor with gear box complete all as specified and as directed. | 1 | Each | 10,000 ₹10,000 Lowest | 22,500 ₹22,500 | 22,000 ₹22,000 | 35,000 ₹35,000 | 19,800 ₹19,800 |
| 6.00 | S&F LED indication lamps, 110 V of various colours including taking down existing un-serviceable LED indication lamps complete all as specified and as directed. | 10 | Each | 100 ₹1,000 | 140 ₹1,400 | 100 ₹1,000 | 150 ₹1,500 | 50 ₹500 Lowest |
| 7.00 | S & F Epoxy Resin Spout bushings for busbar single pole R/B phase, 400-1250 Amps, suitable for 11KV VCB panel & of make as per OEM including taking down existing un-serviceable Epoxy Resin Spout bushings complete all as specified and as directed. | 2 | Each | 5,000 ₹10,000 Lowest | 8,500 ₹17,000 | 7,500 ₹15,000 | 9,500 ₹19,000 | 5,800 ₹11,600 |
| 8.00 | All as per Sl Item No. 7.00 here in before but Y phase | 1 | Each | 6,000 ₹6,000 Lowest | 11,000 ₹11,000 | 12,500 ₹12,500 | 12,000 ₹12,000 | 6,400 ₹6,400 |
| 9.00 | S & F Epoxy Resin Spout bushings for CT/PT/Circuit spout single pole R/Y/B phase, 400-1250 Amps, suitable for 11KV VCB panel & of make as per OEM including taking down existing un-serviceable Epoxy Resin Spout bushings complete all as specified and as directed. | 2 | Each | 5,000 ₹10,000 Lowest | 8,000 ₹16,000 | 6,000 ₹12,000 | 9,500 ₹19,000 | 6,900 ₹13,800 |
| 10.00 | S&F closing coil assembly, 110V DC suitable for 11KV VCB & of make as per OEM including taking down existing un-serviceable closing coil assembly complete all as specified and as directed. | 1 | Each | 3,000 ₹3,000 Lowest | 3,650 ₹3,650 | 4,000 ₹4,000 | 6,000 ₹6,000 | 4,800 ₹4,800 |
Tender Value
₹39.5 L
EMD Value
₹78,900
Closing Date
21 May 2026, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR / MAINT OF HT/LT DISTR SYSTEM, UG CABLES, TRANSFORMERS, RMUS, VCBS, CALIBRATION OF RELAYS AND REPAIR / MAINT OF LT PANELS, UG CABLE AND CERTAIN ALLIED WKS AT INHS KALYANI UNDER AGE E/M NO-I OF GE(U-I) VISAKHAPATNAM
2026_MES_762929_1
8846/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹78,900
Yes
21 Aug 2026
30 Apr 2026
23 May 2026
30 Apr 2026
21 May 2026
15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | M&L for overhauling / repair of 11KV vacuum circuit breaker (VCB) comprising of repairs, complete overhauling / servicing, cleaning of all parts, adjusting contacts, checking epoxy body, drive insulator, spring charge mechanism, locking arrangements tripping coil circuits (closed / open) etc, checking all mechanical operations supporting insulators bush trolley auxiliary contact. make female contact and check all wiring, carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repair / overhauling complete all as specified and as directed.
Note:- (i) The servicing includes for busbar duct chamber, cable alleys and connecting accessories
(ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning.
(iii) Major spares like Breaker bushings, vacuum interrupter assly, busbar spout, busbar spout connections, circuit spout, circuit spout connections, buffer fixed contacts, moving contacts, tank assly, barriers, solenoid spares, dependent, spring mechanism / motor mechanism, trip unit etc will be measured and paid separately under relevant items. However the rate quoted shall be deemed to include for any other minor spares requiring replacement.
(iv) The servicing shall be carried out by auhtorised service engineer of OEM and approval of the same shall be taken from Engr-in-Charge. | 9 | Each Job | - | - |
| 3 | M&L for Overhauling / Repair of 11 KV VCB Panel with cleaning of all parts, checking & cleaning circuit all busbar spout bushings, CT/PT spout bushings, Busbar, cleaning of CT and PT, checking all wiring & rectifying Wiring faults, cleaning metering chamber, applying mono plast compound at busbar joints, fixing up issues with measuring instruments etc including minor item such as nuts, bolts, copper wires, HT insulation tapes etc required for repair complete all as specified and directed.
Note : The testing / inspecting Engineer shall be minimum a State Govt Licence holder or any OEM authorised License holder. | 9 | Each Job | - | - |
| 4 | S&F busbar / CT supporting insulator for 11 KV VCB panel of rating 400 to 1250A, 25KA, suitable for 11kV VCB panel including taking down existing un-serviceable busbar / CT supporting insulator complete all as specified and as directed. | 6 | Each | - | - |
| 5 | S&F spring charging universal motor with gear box 220V AC/DC of rating 400 to 1250A suitable for 11kV VCB including taking down existing un-serviceable spring charging universal motor with gear box complete all as specified and as directed. | 1 | Each | - | - |
| 6 | S&F LED indication lamps, 110 V of various colours including taking down existing un-serviceable LED indication lamps complete all as specified and as directed. | 10 | Each | - | - |
| 7 | S & F Epoxy Resin Spout bushings for busbar single pole R/B phase, 400-1250 Amps, suitable for 11KV VCB panel & of make as per OEM including taking down existing un-serviceable Epoxy Resin Spout bushings complete all as specified and as directed. | 2 | Each | - | - |
| 8 | All as per Sl Item No. 7.00 here in before but Y phase | 1 | Each | - | - |
| 9 | S & F Epoxy Resin Spout bushings for CT/PT/Circuit spout single pole R/Y/B phase, 400-1250 Amps, suitable for 11KV VCB panel & of make as per OEM including taking down existing un-serviceable Epoxy Resin Spout bushings complete all as specified and as directed. | 2 | Each | - | - |
| 10 | S&F closing coil assembly, 110V DC suitable for 11KV VCB & of make as per OEM including taking down existing un-serviceable closing coil assembly complete all as specified and as directed. | 1 | Each | - | - |
| 11 | S&F tripping coil 110V DC suitable for 11KV VCB & of make as per OEM including taking down existing un-serviceable tripping coil complete all as specified and as directed. | 1 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
8846Tender.pdf
Tender Documents • 0.93 MB
BOQ_854589.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .