Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹15.0 L+₹20,330 (1.38%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹21.2 L+₹6.4 L (43.5%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Nov 2023, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
REPAIR / REPLACEMENT OF SOLAR PANEL AND ITS CONNECTED ITEMS INCLUDING USE OF DISINFECTANTS FOR TREATMENT OF WATER AT RAJOURI AND NAUSHERA UNDER AGE E/M OF GE 862 EWS
2023_MES_622054_1
GER-52/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹70,000
Yes
18 Dec 2023
7 Oct 2023
6 Nov 2023
7 Oct 2023
4 Nov 2023
21 Oct 2023
Amount
Supply and adding to water as per requirement for Aluminium ferric Gr-IV as per IS-299 :2012 suitable for treatment of drinking water complete all as specified and directed by Engr-in-charge.
Supply and adding to water as per requirement for Calcium Hypo chlorite granular disinfectant chlorine suitable for treatment of drinking water in 45 Kg HDEP container in factory sealed having chlorine content level 65% to 70% complete all as specified and directed.
Supply and adding to water as per requirement for stable bleaching powder containing 33% of chlorine gas ISI maked Gde-I confirming to IS-1065/ISO-9001 CM/L-1650852 in 25Kg packing in HDPE bags complete all as specified and directed.
M&L for water testing of bore well/dug well and test to be carried out as per IS parameters of drinking water (chemical and beactrological test) from Govt approved labortary as per directed by Engr-in-Charge and report to be submitted to GE 862 EWS for record. Physico-chemical parameters as per the ground water standards IS 10500-2012 colour, odour, taste, turbidity, PH, total dissolved solids, total Hardness (as CaCO3), calcium (as Ca), Magnesium (as Mg, Chloride (as CI), Sulphate (as So4), Iron (as Fe), residual free chlorine (as CI2), Copper (as Cu), Manganess (as Mn), Nitrate (as NO3), Fluoride (as F), Phenolic Compound (as C6H5OH), Mercury (as Hg), Cadmium (as Cd), Selenium (as Se, Arsenic (as As), Cyanide (as CN), lead (as Pb), Zinc (as Zn), Annionic Detergents (as MBAS), Total Alkalinity (as CaCO3), Aluminium (as AI), Boron (as B), mineral oil, Barium (as Ba), Chloramines (as CI2), Silver (as Ag), Sulphide (as H2S), Molybdenum (as MO), Nickel (as Ni), Total Chromium (as Cr), Ammonia (as Total ammonia-N, E Coil, Total Coliforms, Polynuclear Aromatic Hydrocarbons (as PAH), Polychlorinated Biphenyls, Pesticides, Alachlor, atrazine, Aldrin, Dieldrin, Alpha HCH, Beta HCH, Gamma-HCH (Lindane), Delta HCH, Butachor, Chlorpyrifts, 2.4-Dichlorophenoxy Acetic Acid, DDT (o, p and p, p-Isomers of DDT, DDE and DDD), Endosulfan (alpha, beta and sulphate), Redioactive material (alpha emitters, beta emitters Bq/I.max), Ethion, Isoproturon, Malathion, Methyl Parathion, Monocrotophos, Phorate, Trichlocomethane, Bromoform, Dibromochloromethan, Bromodichloromethene, Chloroform. (Note: (i) Cost of collection of samples from any location at and around Rajouri area under the AOR of GE 862 EWS on requirement basis is deemed to be included in the quoted rate. (ii) Cost of transportation of samples form the location of the source to the laboratory within specified time is deemed to be included in the quoted rate. (iii) Test has to be carried out as and when required basis.)
Supply only chlorine test kit including one bottle each of orthotolidine test solution re-usable test vial storage case all as specified and directed.
M&L for over hauling & servicing the solar water heater 100 LPD capacity by repair/replacing of defective parts, descaling remaning bloks in the solar cells by the acid cleaner, including replacement of petty items such as washers, nuts, bolts etc complete all as specified and directed. Note:- Spare parts will be measured & paid separately under respective items).
S&F Heating element 2.5 KW suitable for solar water heater 100 LPD capacity complete all as specified and directed.
S&F Gasket set for solar water heater suitable for 100 LPD capacity complete all as specified and directed.
S&F in Replacement collector water circulater copper pipe complete set with connected Item of solar water heater 100 LPD capacity complete all as specified and directed.
S&F silicon washer for solar water heater 100 LPD capacity complete all as specified and directed.
S&F solar water heater tank Cap 100 LPD capacity complete all as specified and directed.
S&F Mild steel Inner tanks of solar water heater of 100 LPD capacity complete all as specified and directed.
S&F in Replacment of solar water heater Glass Panel of Cap 100 LPD capacity complete all as specified and directed.
S&F brass/bronz PRV 15 mm (pressure release valve) of solar water heater of capacity 100 LPD capacity complete all as specified and directed.
M&L in replacement for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete as in repair all as specified and directed.
M&L for over hauling & servicing the solar water heater 200 LPD capacity by repair/replacing of defective parts, descaling remaning bloks in the solar cells by the acid cleaner, including replacement of petty items such as washers, nuts, bolts etc complete all as specified and directed. Note:- Spare parts will be measured & paid separately under respective items).
S&F Heating element 3 KW suitable for solar water heater 200 LPD capacity complete all as specified and directed.
S&F Gasket set for solar water heater suitable for 200 LPD capacity complete all as specified and directed.
S&F in Replacement collector water circulater copper pipe complete set with connected Item of solar water heater 200 LPD capacity complete all as specified and directed.
S&F silicon washer for solar water heater 200 LPD capacity complete all as specified and directed.
S&F solar water heater tank Cap 200 LPD capacity complete all as specified and directed.
S&F Mild steel Inner tanks of solar water heater of 200 LPD capacity complete all as specified and directed.
S&F in Replacment of solar water heater Glass Panel of Cap 200 LPD capacity complete all as specified and directed.
S&F brass/bronz PRV 20 mm (pressure release valve) of solar water heater Cap 200 LPD.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs tank and making connections including dismantling old unserviceable tank, complete all as specifed and directed.
S&F in repair for stop valve, cast copper alloy, screwed for high pressure with crutch or butterfly handle, screwed suitable for 15mm bore iron pipe or for union both ends, complete all as specified and directed.
S&F brass elbows 20mm dia both end screwed complete all as specified and directed.
Supply and fixing brass unions 20 mm dia to connect iron pipe to polyethylene pipe and fixed complete all as specified and directed.
Supply and fixing brass unions 25 mm dia to connect iron to polyethylene and fixed complete all as specified and directed.
Supply and fixing GI nipple 20mm-45 gm/25mm-65 gm complete all as specified and directed.
Repair/replacment of motor 2 HP capacity for RO plant of 90 LPM capacity as per existing Make at site complete all as specified and directed.
Servicing of RO plant of capacity 90 LPM complete through company as per existing make complete all as specified and directed.
Servicing of RO plant of capacity 12 LPM complete through company as per existing make complete all as specified and directed.
S&F of Filter Membrane for RO plant of capacity 90 LPM as per existing make complete all as specified and directed.
S&F in replacement of RO plant Filter capacity 90 LPM as per existing make complete all as specified and directed.
S&F in replacement of RO plant Filter capacity 12 LPM as per existing make complete all as specified and directed.
Supply and fixing in repair 3 layer PPR ( Polypropylene random copolymer ) pipe having outer dia 20 mm (PN 25) stablized and anti microbial fusion welded having thermal stabilty for hot and cold water supply including all PPR plain and brass threaded polyproyline random fitting such as Elbow, Socket, Tee, Union, Clamp, end cap etc. fixed to wall ceilings or in floors etc. complete all as specified and directed.
Supply and fixing in repair 3 layer PPR ( Polypropylene random copolymer ) pipe having outer dia 25 mm (PN 25) stablized and anti microbial fusion welded having thermal stabilty for hot and cold water supply including all PPR plain and brass threaded polyproyline random fitting such as Elbow, Socket, Tee, Union, Clamp, end cap etc. fixed to wall ceilings or in floors etc. complete all as specified and directed.
Supply and fixing threaded Cap for PPR (Polypropylene random copolymer) pipe having outer dia 20 mm (PN25) complete all as specified and directed.
Supply and fixing threaded Cap for PPR (Polypropylene random copolymer) pipe having outer dia 25 mm (PN25) complete all as specified and directed.
Supply and fixing in repair gun metal Spindle of size 20 mm dia complete all as specified and directed.
Supply and fixing in repair gun meta Spindle of size 25 mm dia complete all as specified and directed.
S&F in repair for 20mm bore gun metal, gate valve with iron wheel head screwed on both sides for iron pipes, complete all as specified and directed.
S&F in repair for 25mm bore gun metal, gate valve with iron wheel head screwed on both sides for iron pipes, complete all as specified and directed.
S&F in repair for sheet metal enclosure for distribution board, triple pole and neutral enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 amp 10KA 'C' series, complete all as specified and directed
Supply, Laying, connecting and testing of aluminium multistrand wire of size 10 Sqmm 2 core 1100 volts grade heavy duty PVC insulated stranded, after taking down old unserviceable wire, complete all as specified and directed.
narayan construction
M/s Kay Aar Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .