Special repairing and renovation work of Substation, Installation of submersible pump motor Set at Girls Hostel and deployment of an electrician for one year at the College of Agriculture Extended Campus under Uttar Banga Krishi Viswavidyalaya, Majhi
2026_NBDD_1038264_3
NBDD/BS/EE /NIQ-16- (EL) of 2026-2027(SL No. 01 to 10)
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Dakshin Dinajpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.2 L
Yes
14 Aug 2026
14 Aug 2026
3 Sept 2026
14 Aug 2026
31 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)- i) 250 watt.(Model HLFLD-ML14-250-CWDL-R-B-P Make Halonix / Model JETASPECTRAFLS250WLED757SSYMTOPC Make Havells or equivalent model of Philips/Wipro) Submission of test report and warranty certificate of atleast five years from OEM is mandatory. | - | Each | - | - |
| 2 | ii) 70 watt | - | Each | - | - |
| 3 | Supplying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C,
internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P.F.≥0.95, IP-66,IK- 08, CRI >70, under voltage and over voltage
protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 900C)- 72 Watt.( Model HLSLD-01-72-CWDL-R-P Make Halonix/ Model Endura SundownNXT HO 70W(SLLT70) Make Havells or equivalent Model of Philips/Wipro as per the choice of EIC) | - | Each | - | - |
| 4 | Laying of one number PVC insulated and PVC
sheathed / XLPE power cable of 1.1 KV grade of
following size direct in ground including excavation,
sand cushioning, protective covering and refilling the
trench etc as required.
Upto 35 sq. mm | - | Meter | - | - |
| 5 | Above 35 sq. mm and upto 95 sq. mm | - | Meter | - | - |
| 6 | Laying of one number PVC insulated and PVC
sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing RCC/ HUME/ METAL
pipe as required- Upto 35 sq. mm | - | Meter | - | - |
| 7 | Supplying & fixing heavy gauge 80mm dia G.I. Pipe as par IS/1239 ISI MARKED. | - | Meter | - | - |
| 8 | Supplying and making end termination with brass
compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE
aluminium conductor cable of 1.1 KV grade as
required. i) 2 X 10 sq. mm (19mm) | - | Each | - | - |
| 9 | ii) 4 X 50 sq. mm (35mm) | - | Each | - | - |
| 10 | ii) 3½ X 95 sq. mm (45mm) | - | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2550518.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].