| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L1 | Accepted-AOC AOC | |
| 2 | L2₹30.1 L+₹2.7 L (9.90%)Rejected-Finance | L2 | Rejected-Finance Being higher bid | |
| 3 | L3₹30.5 L+₹3.1 L (11.2%)Rejected-Finance | L3 | Rejected-Finance Being higher bid | |
| 4 | L4₹30.7 L+₹3.3 L (12.0%)Rejected-Finance 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L4 | Rejected-Finance Being higher bid | |
| 5 | L5₹30.7 L+₹3.3 L (12.1%)Rejected-Finance R O 89 PRABHAT NAGAR NEAR RAM JANKI MANDIR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L5 | Rejected-Finance Being higher bid |
Tender Value
₹47.0 L
EMD Value
₹94,060
Closing Date
27 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bareilly
HQ, CWE, MES, Station Road, Bareilly
CWE BLY/GE (W) /61 OF 2023- 2024 SPECIAL REPAIRS TO BLDG NO. T-117 (MULE LINES) AT ADV FD VET HOSP UNDER GE(WEST) BAREILLY
2024_MES_635782_1
8100/B/785/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Bareilly
As per NIT
6 documents required · 6 mandatory
₹500
GE (West) Bareilly
₹94,060
Yes
28 Feb 2024
4 Jan 2024
29 Jan 2024
4 Jan 2024
27 Jan 2024
19 Jan 2024
Amount
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 including demolition of brick work in cement mortar complete all as specified and directed.
M&L for 15mm thick rendering on internal surface in cement mortar 1:6 to on brick masonary wall on other than fair faces of brick masonary finished even and smooth with out using extra cement including taking down old cement plaster complete all as specified and directed.
M & L for 15 mm thick rendering on external surface on fair faces of brick work or concrete surfaces with cement mortar 1:4 with mixing of water proofing compound 3% by weight of cement or as per manufacturer’s instructions complete all as specified and directed.(Note:- Water Proofing compound shall be measured and paid seprately)
Taking down old cement or cement lime plaster, any description complete all as specified and directed.
Supply only liquid water proofing compounding conforming to IS specification complete all as specified and directed.
M&L for 100 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in floors, in alternate bay finished even, smooth and impression of expended metal while the concrete is green complete all as specified and directed
M & L for applying two coats of oil bound distemper white or tinted on newly decorated or undecorated wall surface with airless electric sprayers over a coat of primer applied using airless electric sprayer over a coat of wall care putty of 1mm th. including preparation of surfacesby washing rubbing down and stoping of distempered and painted surfaces complete all as specified and directed.
M&L for preparation of new plastered walls surfaces and applying two coats of Cement based paint paint over a coat of primer over chalk whitening on plastered surface complete all as specified and directed.
M&L One coat of cement base paint on old plastered wall surfaces of any description including preparation of old surfaces and filling depression surface with wall care putty, complete all as specified and directed.
M& L For forming necessary joints 12 mm wide to the full depth of PCC at every 3 mtr and every change of direction and filling the same with bitumen filler 1:3 by weight complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) as in floor/plinth protection, finish the surface even and smooth without using extra cement complete all as specified and directed.
Taking down Shutters of any description n exc 1 sqm each complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completek confirming to Fe -290 Gde-E-165 complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including distance pieces, cleats, nut bolts etc complete all as specified and directed.
M& L for Preparation of new iron surface and two coats of synthetic enamel paint ovar a coat of red oxide primer over 10 cm width and girth complete all as specified and directed.
S& F for M S Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ridge / cladding to wall, fixed with self tapping screws as specified for Asbestos cement two pieceadjustable plain wing ridge 6mm thick Fixed with L-type or Jtype or cranked hook bolts complete all as specified and directed.
Removing of demolished material or demolished materials exc. 250 m but n exc. 500 m and depositing where directed Complete all as specified and directed.
M&L for plain Cement concrete Type B2 1:2:4 (20mm graded graded stone aggregate) as in surface channels and drains or walls or retaining walls, any thickness, size or shape including pilasters, buttresses boundary pillars and posts (including caps and bases) complete all as specified and directed.
M&L for plain Cement concrete Type C2 1:3:6 (40 mm graded stone aggregate) as in foundations, filling and mass concrete for drain etc. complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms maulds intered stopped end etc.all as specified and directed.
S&F in replacement GI tubing of 15 mm dia medium grade with and including all fittings and fixed to walls or ceiling (concealed) or laid in floors and connections complete all as specified and directed.
S&F in replacemnt 15 mm dia bib tap fancy type chromium plated with flange quarter turn complete all as specified and directed.
S&F in replacement fancy type chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified and directed.
S&F in replacement GI tubing of 20 mm dia medium grade with and including all fittings and fixed to walls or ceiling (concealed) or laid in floors complete all as specified and directed.
S&F in replacement sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, including Waste fittings, brass, chromium plated overall size 685mm x 510mm bowl size 610mm x 460mm x 254 mm complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for 20mm (+ 2mm) thick marble tiles machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry including cutting and polishing of type and inclucding 10mm thick cement plaster on brick surfaces or concrete surface in cm (1:4) finished even and rough as screed including dismantling of wall tile including cement mortar bedding complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed
S & F rubber moulded coloured Chequered cement concrete tiles 25cm x 25 cm x 22 mm thick, bedded over and including screed bed 20mm thick in CM 1:6 set and jointed in neat cement slurry and pointed with white cement and pigment complete all as specified and directed.
S & F Machine pressed precast concrete inter moulded interlocking paver block any shape and size ISI marked of 80 mm thickness M-40 Grade bedded over 25 mm thick sand cushion including filling the joint with sand including dismantling existing tiles/paver block complete all as specified and directed.
S & F for Welded steel wire fabric N exc 4 kg supplied and fixed complete to wood or steel members complete all as specified and directed.
S & F 100 mm dia Tubes, medium grade' galvanised, with and including all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F 4mm thick Non asbestos fibre cement building boards fixed or laid / inserted to timber / Aluminium framework E-Board tiles for insulation and acoustic purpose of size 600x 600mm fixed with and including anodised GI prepainted snap grid with 25x25x1.5 mm thick Tee section and 38x25x2 mm thick angle with hanging/supporting arrangements as in false ceiling at bottom at spacing 60 cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fastners complete and making good disturbed surfaces complete all as specified and directed.
M&L for 75mm thick cement concrete type C2, 1:3:6 (using 40mm graded stone aggregatye ) as in sub base of floor and finished the surface even and fair complete all as specified and directed.
M & L for designer glazed ceremic coloured tiles as in vertical surface 350x 250x7mm / 450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick plaster in cement mortar 1:4 including dismantling of wall tile including cement mortar bedding complete all as specified or as directed.
M & L for Providing, cement concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in bed block / hold fast , roof kerbs or mud stops, rounded or chamfered on edges complete all as specified or as directed.
S & F 12mm dia of neck Mild steel bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n exc 15cm long complete all as specified or as directed.
S & F 20 mm dia Mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 15cm long and n Exc 30cm long complete all as specified or as directed.
Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixture such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Material and labour for point wiring with single core FRLSH 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered with modular plate and cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:- (a) One light / fan/ exhaust fan point controlled by one switch complete all as specified and directed.
(b) One 5 pin 5 Amp socket out let point controlled by one switch on same board.
(c) One multi Pin socket out let point on an independent board
Material and labour for point wiring with single core FRLSH 1100 volt grade cable with multi stranded copper conductor of size 2.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered with modular plate and cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified and as directed.
S&F Switch piano, flush button, single pole, one way, 16 Amps complete all as specified and as directed.
S&F socket outlet 16 Amps, 3 Pin complete all as specified and as directed.
S&F Switch piano, flush button, single pole one way 06 Amps complete all as specified and as directed.
S&F socket outlet 3 in1, 3 pin, 6 Amps complete all as specified and as directed.
S&F fan regulator 230 volt, electronic flush socket step type, AC complete all as specified and directed .
Supply and Fixing ceiling rose PVC / Poly carbonate, Isolated body, three terminal AC 230 volts complete all as specified and directed.
S&F in replacement LED light fitting high lumens battern type housed in extrud from powder coated aluminium , 20 Watt for soft diffuser lighting with and including lamp and connecting up complete with PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitabble size and testing on complet all as specified and directred.
Supply and fix LED lamp 7 Watt complete all as specified and as directred.
Supply and fix, Lamp Holder PVC type complete all as specified and directed.
Supply & Fixing security light fitting, LED type, 25 Watt, 6000 K, pressure die cast housing with prismatic polycarbonate diffuser & indvl LEDs as light source with integrated electronic driver complete with and including M&L GI pipe mounting bracket of size 32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
Material & Labour for earthing and testing complete with galvanised steel earth plate 600x600x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using 4 mm dia GI wire as earth wire electrode moulded and rivetted to earth plate at one end and connected to main switch/ control switches of buildings at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto main switch board of building including 20 dia bore GI pipe 'light grade' as water pipe from earth chamber and including excavation and earth work, PCC 1:3:6 type C1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced, as showm on electric plate No. 3 of SSR Part-I complete all as specified and directed.
Taking down carefully ceiling fan and refixing the same after bldg repair including painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. painting and servicing etc. complete all as specified and directed.
M&L in replacement for sub main wiring with two single core 4.0 Sqmm (FRLSH) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLSH) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 4.0 sqmm (FRLSH) and one run of 4. sqmm (FRLSH) copper conductor shall be measured as one unit length.) complete all as specified and as directed.
Rewinding of ceiling fan with copper wire including replacement of bearing bush rod greasing and painting with white paint including writing MES No on fan blade and top with black paint complete all as specified and as directed.
S&F in replacement flush sheet metal enclosure SPN DB 8 way with double door IP-42 protection detachable gland plates, flush mounting for MCB fitted with bus bar , earth bar and neutral links complete all as specified and directed.
S&F in replacement luminature circuit breakers type curve 'B' , 10KA, SP , 6 to 32 Amps complete all as specified and as directed.
S&F in replacement luminature circuit breakers SPN 32A, type curve 'B' 10 KA, 230 Volts complete all as specified and as directed.
Taking out old unserviceable LT cable and Supply, laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 4 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 m in depth, getting out in soft/loose soil etc., in luding trimming bottom and sides of trenches, leveling/grading and ramming bottom of excavation complete all as specified and directed
Returning , filling in including spreading, leveling, watering and well ramming in laying not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soils) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for river fine sand, washed and screened dry for cushioning to underground cable in trenches below and around underground cable including spreading and leveling punning complete all as specified and directed.
M&L for laying fly ash bricks for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed.
S&F Galvanized steel water tubes medium grade 40mm bore with and including all fittings laid in trench as complete all as specified and as directed.
Harsha Consultant and Builders
REHAN CONSTRUCTIONS
R K CONSTRUCTION
MARUTI BUILDERS
hardeep singh enterprises
Mohit Enterprises
khanna construction
M/S Gupta and Company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .