GE NORTH AKHNOOR
GE NORTH AKHNOOR PIN 181201 CO 56 APO
COMPREHENSIVE REPAIR MAINT OF ACSR CONDUCTOR VECTOMETER EARTHINGS INSULATORS PAINTING OF POLES CLEANING OF BUSHES BRANCHES DISTRIBUTION PANELS MCCB LIGHTENING CONDUCTOR INCLUDING STORAGE TANKS CLEANING OF UG SUMPS OHT PAINTING WORKS AND CONNECTED IT
2022_MES_542751_3
GE(N)/AKH-42/2022-23
Open Tender
Civil Works
Item Rate
180 days
BARAKH NODE AND SUNDERBANI
Class D Cat b i
8 documents required · 8 mandatory
₹500
Yes
GE NORTH AKHNOOR
₹66,000
Yes
6 Jan 2023
13 Oct 2022
12 Nov 2022
13 Oct 2022
10 Nov 2022
27 Oct 2022
Amount
M&L for replacement of broken over head conductor of any type and length as required at site including removing of foreign objects,and the same replace with new Aluminium conductor steel reinforced all as specified and directed.
M & L for replacement of pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade.
All as per srl item No 2 above, but 150mm height, 150mm dia for 11000 volts grade.
M & L for replacement of shackle type porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 75 mm and max dia 90 mm suitable for working pressure 1100 volts grade.
All as per srl item No 4 above, but 150mm height, 150mm dia for 11000 volts grade.
Taking down UNSV PCC poles and replace with Steel tubular swaged pole complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9.0m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed (PCC, earth work shall be measured & paid separately under respective items).
Taking down UNSV PCC poles and replace with Steel tubular swaged pole complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-64 (11.0m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed (PCC, earth work shall be measured & paid separately under respective items).
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
M & L PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping, kneelers, apex stones, bed plates, bed blocks and the like including weathering, slightly rounded or chamfered angles as directed including necessary formwork and finishing the exposed surfaces, complete, all as specified.
M & L PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in pole base, kneelers, apex stones, bed plates, bed blocks and the like including weathering, slightly rounded or chamfered angles as directed including necessary formwork and finishing the exposed surfaces, complete, all as specified.
M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in coping or pole coupling of size 300x300 mm or chamfered on edges all as specified and directed.
Material and Labour in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size for HT,25X20cm size complete all as directed by Engineer-in-charge.
M & L for Restringing of loose over head conductor/GI earth wire of any size and type after untyeing binding wire from insulators/cross arms to achieve permissible sag limit of over head line including new binding wire of proper size and pruning of tree branches of concerned spans and jointing of jumpers properly complete all as specified and directed at site. Note:- (i) One job consist one span of 3-phase, 4-wire over head line. (ii) The distance of one span is approx 30 to 50 meter.
Supply and fixing in repairs mild steel galvanised stay assembly set complete comprising of 20mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part-I 2009 complete all as directed.
Supply and fixing in replacement female contact spring loaded having brass contacts suitable for GOD 200A for working pressure 11000Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation all as required at site or directed by Engr In charge.
Supply and fixing in replacement male contact with arching horn having brass contacts suitable for GOD 200A for working pressure 11000Volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation all as required at site or directed by Engr In charge.
Supply and fixing in replacement copper braided belt 400mm long with MS carrier suitable for GOD 200A for working pressure 11000Volts, galvanised iron bolts, nuts and washers for fixing all as required at site or directed by Engr In charge.
Supply and fixing in replacement lightning arrestor expulsion type complete with all fitings,transmissin class, discharge capacity 65 Kilo amp suitable for 11000V all as spfd and as dircted. Make :-BHEL,Jaipuria,Alsthom
Cutting/trimming/Chopping of tree branches along the over head lines of 33/11KV line upto 5 mtr from elect line on both sides of the span and disposing off the cut trees/branches to a distance of n.exc 50m and clearing the site as directed by Engr-in-Charge.
M & L for Construction of brick masonary platform of size 3x2.5x1.2mtr, 230mm thick with old size brick CM 1:6 including 15 thick plasterting in CM 1:4 in all sides with plinth protection of lenght of 60 cm around and brick steps with plastering in CM 1:6 with XPM fencing 1.2 mtr height with weight not less than 4 Kg per Sqm and angle iron 50x50x6mm for supports gate with locking arragement inculding painting with synthetic enamelled paint and PCC floor in cement concrete 1:2:4 type B1 50mm thick incuding filling all as specified and as directed.
Earthing complete with galvanised steel earth plate elcrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m below normal ground level connecting to the GI earthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregrate with 40mm thick cover of RCC (1:2:4) raniforced with XPM (weight not less than 4Kg/sqm) and frame of angle iron 25x25x6mm with lugs 02 nos and 6mm dia MS bars handle made to shape, GI Light grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth plate incl common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50m all as per electrical plate no 3 of SSR 1991 Pt-I and connecting to earh test point incl testing on completion. Note:- The required resistance of Earthing shall be less than 2 ohm, If not fouund to the required resisstance, the contractor has to re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
Scraping of old paint of pole structure without removing accessories and preparation of surfaces for repainting. Repainting the poles with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamel paint .Repainting the remaining Iron parts i.e. cross arms, supporting angles, XPM jali, clamps, GI bkt etc and steel pole above 1.5 mtr height by applying one coat of aluminium paint or PCC pole with snowcem of approved color all as required at site or directed.
Taking out carefully stone aggrgrate of any size from the bay/yard without damaging the equipments,cable or any parts of 33KV Grid bay,removing of ducts,sand/grass etc, spreading and levelling of finished gravel uniformally in layers not exc 20cm thick,rammed and watered to a true surface all as specified and directed.
M&L for sieving out graded coarse aggrgrate and taking out sand dust/gravel of size less than 25mm of nominal size and Supply filling and laying coarse aggregrate normal size 25 mm at 33 KV Grid bay/yard , deposted spread and levelled in layers not exc 15cm thick,rammed and watered to a true surface all as specified and directed.
Material and labour for retro reflective installation sign board size 6ft x4 ft fabricated out of 1.6mm MS sheet frame welded/riveted with stainless steel pipe finished in square of size 25mmx25mm at 2.5m height from ground level on stainless steel finished pipe of size 50mm fixed with PCC 1:2:4 Type B-1 of block size 45cmx45cmx60cm.The board shall be painted in stove enamelled paint and the front and back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The writing shall be in English language on both sides with reflective adhesive painter tape all as specified and directed.
Scraping of old paint of 33/11 KV Substation (02 Nos bay) steel structure posts by using emery/iron brush and painting with two coats of aluminium paint to complete 33/11 KV substation incl entire steel post in substation consisting of angle/channel steel structure upto height of 6mtr, spray painting of 02 Nos 33/11 KV 3.15 MVA transformer as per existing incl aluminium painting of XPM jalli around transformer, spray painting to CT/PT units all as specified and directed. Note:- contractor has to take complete shut down and contractor shall not be provided working periods more than 02 hrs/day .
M&L for black steel jalli mesh having steel wire dia 4mm interwooven in square shape upto height 5ft incl aluminium painting after fixing on steel angle post all as specified and directed.
M&L for joist,channel,angle or Tee sections, Fe 410-w (Gde -E-250 quality) fixed independently without connecting plates etc cut to ordinary length as required all as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation etc for laying cable including getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m deep for foundation etc for laying cable including getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading watering and well ramming in layers not exc 25 cm complete all as specifed .
Removing surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
Supply and fixing in repair Aluminium lugs of size 25 sqmm
Supply and fixing in repair Aluminium lugs of size 35 sqmm
Supply and fixing in repair Aluminium lugs of size 50 sqmm
Supply and fixing in repair Aluminium lugs of size 70 sqmm
Supply and fixing in repair Aluminium lugs of size 95 sqmm
Supply and fixing in repair Aluminium lugs of size 120 sqmm
Supply and fixing in repair Aluminium lugs of size 185 sqmm
Supply and fixing in repair Aluminium lugs of size 300 sqmm
M & L in replacement Switches air break,gang operated Triple pole, mechanically operated, mounted on insulator and steel work from ground level, for frame, with operating mechanism current rating upto 400 amps
Dismantling and taking down Aluminium strip fixed on roof, floor wall and taking out old saddles and earthing strip in original state all as specified and directed.
Aluminium strip obtained from Item Ser No 42, making it serviceable strip (afrer removed/avoided bends and foldings of aluminium strip) and the same refixing on new PVC saddles and connecting to earthing strip in original state all as specified and directed.
Supply & fix in replacement fix aluminium strip 25x3 mm to be fixed on PVC insulators with fixing screws on roof, wall including down conductors strip etc, and taking down of old aluminum conductor srtip from any position and places all as specified and directed.
Supply and fix in replacement PVC insulator along with screws, accessories on wall, roof etc suitable for fixing aluminium strip of size 25x3 mm complete including taking down on old unsv insulators complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement air termination single pointed aluminium rod 12 mm dia, 300 mm long fixed complete as specified and directed. Note : Cost of PCC block will be measured and paid separately Cost of minor job and spares required for fixing of aluminium rod on PCC block & for fixing Aluminium strip to rod is deemed to be included in the quoted rate.
Supply and fix in replacement test point terminal block made of Gun Metal or phosphrus bronze of size 75 x 75 x 25 mm drilled & screwed including 03 Nos 8mm dia 25mm long hex head screw including taking out all broken test point terminals from any position and any places.
Supply and fix in replacement galvanized iron strip of size 32x 6 mm to be fixed on wall or to be laid in ground , complete all as specified and including taking down from any position and any places and as directed by Engr-in-Charge.
Demolition and taking out old damaged earth pit PCC chamber with cover. M& L for preparation of new PCC chamber in cement concrete 1:2:4 type B1 cover duly reinforced with XPM (weight not less than 4 Kg/sqm and CI frame and other provisions all as shown electrical plate No-3 of SSR-2009 Part-I complete all as specified and directed.
M & L for laying GI tubes light grade, 40 mm dia for protection of earth continuity leads.
Cleaning of internal wall/floors of RCC over head reservoirs of Capacity 75000 Gallon including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste by opening wash out valves and applying caustic soda solution and one coat of lime wash internally including cement base white wash of complete OH tank external wall, bottom surface, pillar and painting of raising main pipe line and delievery line by black paint and writing work with one coat of synthetic enameled paint as per colour code for (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank etc, complete all as specified and as directed. NOTE : All precautionery measure such as safety belt, climbing rope etc to be taken by the contractor for safeguard of human life while working on overhead reservoir.
Surface excavation n exc 30cm deep and averaging 15 cm any type of soil all as specified and directed.
M&L for rolling and consolidating of soling of broken boulders not exceeding 15cm thick with power roller exc 5 tonne and nexc 8 Tonne.
M&L for broken stone boulder hardcore of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface.
M&L for cement concrete in foundation, filling and mass concrete type D2 1:4:8 40 mm graded (100mm) all as specified and directed.
M&L for cement concrete Type B2 1:2:4, 40 mm graded Aggrgrate 100mm thick all specified and directed.
Cleaning of internal walls for underground or semi underground sump located at Stage II, Pump House of Capacity 50000 Gallons. The work also includes washing with clean water and bleaching powder including scraping with wire brush on walls and floors & removing mud and grits & deposits etc throw out propeprly to a distance not exceeding 50 Mtr. including cement base white washing of external wall and painting of raising main pipe line and delievery line by black paint and Writing the date of cleaning and due date of cleaning on a rectangular box of size 75cm x 50cm, wriing in white in colour on black back all as specified and as directed.
M&L for Chlorine testing kit compete with test tubes, solution complete all as specified and directed by Eng-in-Charge.
Testing of water by the approved govt lab authority’ and test the following perameter of water :- PH range, Total solids, total hardness, Floride, Nitrites, Nitrates, Lead Arsenic, Ammonia, Chlorides, Cadmium, Cyanide, Mercury Iron, Management, Surphate, Phernolic and submission the report to Deptt or as directed by Engr-in-charge Note :- water collected on present of medical staff / MES staff and empty collection sample bottle will be provide by the contractor
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness with grey cement and pigment M35 Grade all as specified and directed.
M&L for sand filling under floors or in foundation incl watering and consolidation all as specified and directed.
Supply and fixing in replacement “Lithium based Energy Efficient Integrated Solar Street Light of 20Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 44/46Wp , Lithium Battery 11.1/12.8V, 24.2AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower lightl evel with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 10-12kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required.Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of Make:- Axxon (AXN-20W) or equivalent in Bajaj /phillips/Halonix
Material and labour for painting and writing letters "SAVE WATER" in Black letter size 36"X18" on dome of over head water RCC tank and UG Sump , writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 80 mm size on external surface of wall with white enamel paint over black background of any capacity over head tank and UG Sump all as directed Engr-in-charge
Supply and fixing Glow sign board made of acrylic sheet reactangular shape having lighting arrangement of superior quality of size 5'x2'x8" showing installation Nomenclature as approved marked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
Fabrication of angle stand made of angle size 50x50x6mm for Glow sign board, incl jointing of Tees,incl PCC all as specified and directed
m/s vishkarma construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .