Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹100.0 LAccepted-AOC RABINDRA NAGAR P O RABINDRA SARANI SILIGURI 734 006 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹1.0 Cr+₹3.7 L (3.71%)Rejected-Finance RAJA RAMMOHAN ROY ROAD SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹1.0 Cr+₹3.9 L (3.87%)Rejected-Finance 389 A PURBACHAL PRADHAN NAGAR SILIGURI 734 003 | SILIGURI | DARJEELING | WEST BENGAL | 734003 | L3 | Rejected-Finance Higher Bid | |
| 4 | L4₹1.0 Cr+₹4.1 L (4.06%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L4 | Rejected-Finance Higher Bid | |
| 5 | Rejected-Technical 13 RAMLAL MUKHERJEE LANE P O KHAGRA DIST MURSHIDABAD PIN 742103 | KHAGRA | MURSHIDABAD | WEST BENGAL | 742103 | - | Rejected-Technical Documents are not in order |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
16 Jul 2025, 2:00 pmClosed
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
S.I.T.C of 10 nos. of 30 KVA and 1 no. of 40 KVA Silent D.G set along with inverter for Hon ble Judge s Bungalows at the Circuit Bench of Calcutta High Court Jalpaiguri.
2025_WBPWD_852681_1
WBPWD/SENBEC/NIT-02/2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Rate
365 days
Circuit Bench of Calcutta High Court Jalpaiguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹2 L
Siliguri
29 Aug 2025
26 May 2025
18 Jul 2025
26 May 2025
16 Jul 2025
10 Jun 2025
4 Jun 2025
Amount
SITC of 30 KVA Silent DG Set : SITC of 30 -KVA, 415V, 50Hz, 3Ø silent type new DG Set, comprising of Engine, alternator, separate AMF panel, Engine & alternator from the same manufacturer, Base frame, Fuel tank, Battery, CPCB-IV+ approved Engin & Acoustic Enclosure having following specifications :- (conformance standards - IS/IES 60034-1, ISO 1460, ISO 8528, ISO 3046, ISO 9001, ISO 13018)
ENGINE Make: Cummins/Catterpillar/VOLVO Penta/Mahindra/Kirloskar/ Ashok Leyland Engine Type : 4 Stroke Diesel Engine RPM : 1500 Rated Output : 40 BHP or Higher Duty : PRIME Cooling : Liquid Cooled Cylinder : 3 Aspiration : Turbo Charged inter cooled. Type of Governer : Electronic Fuel Tank Capacity : Minimum capacity 72 Liters Diesel Tank , with Inlet & outlet arrangement with Drain Plug and Air vents. Fuel Consumption at 75% rated Load with Radiator or Fan : 5.19 Ltr./ Hr. or Less Fuel Consumption at 100% rated Load with Radiator or Fan : 6.89 Ltr./ Hr. or Less Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator. Exhaust Silencer : HOSPITAL GRADE TYPE Starting system : 12V, DC power srtarting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard. LOAD :Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528 Battery : 12 V X 1, Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning. Emission Norm- CPCB IV+ Emission compliant. ALTERNATOR Make: Stamford/ Leroy Somer /Kirloskar /ABB/GE Rating : 415 V., 3Ph. 50 Hz. 30 KVA, 1500 rpm. Type : Brushless, self excited and self regulated through an AVR. Insulation Class : H Protection : screen-protected drip proof with Min.IP-23 degree of protection. RPM : 1500 Rated Current: 42 A
Voltage Regulation (max) : ±1% Winding connection : Star with Neutral Total Distortion factor : NO Load<1.5%, Non distorating balanced, Linear load <5% Power Factor : 0.8 pf (lag) Total Harmonic distortion in output waveform : < 5%
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure. ACOUSTIC ENCLOSURE The DG set should have integrated acoustic enclosure at the manufacturing state itself with 11 tank process. High quality acoustict enclosure must be certified as per CPCB-IV+ norms. Sound Level : <75 dBA at 1 meter distance. BASE FRAME Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
SITC of 40 KVA Silent DG Set : SITC of 40 -KVA, 415V, 50Hz, 3Ø silent type new DG Set, comprising of Engine, alternator, separate AMF panel, Engine & alternator from the same manufacturer, Base frame, Fuel tank, Battery, CPCB-IV+ approved Engin & Acoustic Enclosure having following specifications :- (conformance standards - IS/IES 60034-1, ISO 1460, ISO 8528, ISO 3046, ISO 9001, ISO 13018)
ENGINE Make: Cummins/Catterpillar/VOLVO Penta/Mahindra/Kirloskar/ Ashok Leyland Engine Type : 4 Stroke Diesel Engine RPM : 1500 Rated Output : 51.8 BHP or Higher Duty : PRIME Cooling : Liquid Cooled Cylinder : 3 Aspiration : Turbo Charged intercooled. Type of Governer : Electronic Fuel Tank Capacity : Minimum capacity 100 Liters Diesel Tank , with Inlet & outlet arrangement with Drain Plug and Air vents. Fuel Consumption at 75% rated Load with Radiator or Fan : 6.30 Ltr./ Hr. or Less Fuel Consumption at 100% rated Load with Radiator or Fan : 8.50Ltr./ Hr. or Less Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator. Exhaust Silencer : HOSPITAL GRADE TYPE Starting system : 12V, DC power srtarting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard. LOAD :Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528 Battery : 12 V X 1, Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning. Emission Norm- CPCB IV+ Emission compliant. ALTERNATOR Make: Stamford/ Leroy Somer /Kirloskar /ABB/GE Rating : 415 V., 3Ph. 50 Hz. 40 KVA, 1500 rpm. Type : Brushless, self excited and self regulated through an AVR. Insulation Class : H Protection : screen-protected drip proof with Min.IP-23 degree of protection. RPM : 1500 Rated Current: 55.6 A
Voltage Regulation (max) : ±1% Winding connection : Star with Neutral Total Distortion factor : NO Load<1.5%, Non distorating balanced, Linear load <5% Power Factor : 0.8 pf (lag) Total Harmonic distortion in output waveform : < 5%
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure. ACOUSTIC ENCLOSURE The DG set should have integrated acoustic enclosure at the manufacturing state itself with 11 tank process. High quality acoustict enclosure must be certified as per CPCB-IV+ norms. Sound Level : <75 dBA at 1 meter distance. BASE FRAME Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
DG UTILITIES Supplying and fixing exhaust gas piping (75 MM Diameter ). welded black MS, B class pipe conforming to IS: 3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50 mm thick wiremesh and aluminium cladding etc., as per requiremement of pollution control norms and required as per direction of Engineer-in-Charge and manufacturer recomendation.
Supply and pouring of H.S. Diesel oil for necessary commissioning of new DG incl. transportation cost. (for 11 Nos. Silent DG Set.)
Excavation of soil for installation of Earth Electrode and filling & ramming. - For Soft Soil.
Earthing with 65 mm dia GI pipe (TATA-Medium) x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mtr.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. - G-2/ 3.a.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode. - G-2/ 3.b.
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. G-3/ 5.e.
Supply of XLPE Insulated & armoured stranded Copper Conductor control cables having following numbers of core for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C]
7 Core 2.5 Sqmm
5 Core 2.5 Sqmm
2 Core 4.0 Sqmm
Supply of 2/4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C]
4 core x 25 sq.mm. (To be laid from each of the 30 KVA DG to each of the Judge's Bungalow panel/VTPN DB)
4 core x 35 sq.mm. (To be laid from DG Amf panel of 40 KVA DG Set to the Change over 100 A change over at the Chief Justice Bungalow)
Laying of one No. 35 sqmm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. [PWD/GS Page: F-2 Item: 1/a]
Laying of 3(Three) cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 915 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting F-1/ 2.b.
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting F-1/ 2.c.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : - [PWD/GS Page No.: F-4 Item No.: 7/c]
4 core x 25 sq.mm.
4 core x 35 sq.mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. [PWD/GS Page No.: F-5 Item No.: 8/b]
4 core x 25 sq.mm.
4 core x 35 sq.mm.
S&F medium gauge 50 mm dia GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required as per GS. PWD/GS Page: F-6 Item: 11
S&F medium gauge 40 mm dia GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required as per GS. PWD/GS Page: F-6 Item: 11
Supply & Fixing Single Bakelite Sheet Board (24" x 18") on wall with necy. Nuts, Bolts, Serews etc. as required incl. Supply & Fixing 3 Nos. 415V, 100A cutout (Make - Havells, Cat No. IHKKDN4100) and 1 No. Neutral Bar on Porcelain insulator on hylam sheet for cutout installation.
Supplying and fixing 415 V 100/125A TPN Main Switch with Sheet Steel enclosure on angle iron frame on wall with nuts, bolts etc.(One each in the ten Judge's Bungalows and one in Chief Justice's Bungalow ) - D-1/1(b)
SITC of 2 KVA Inverters and its allied batteries and rack: SITC of 2 KVA UPS including Battery Bank of 2496 VAH or higher (SMF Battery 12 Volt ) [Make- Amaron/ Exide] 1ph Input / 1ph Output, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 90% efficiency on 100% Load.The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 100% resistive Load, Wave form - Pure sine wave. It Should be capable of operating in 50’c above ambient temparature, Built in Solid State float cum boost charger with automatic boost /trickel charge mode with current limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load/ Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Inbuilt Isolation Transformer of 1:1 ratio connected in Delta- Star Mode . Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type : AGM or VRSLAB in ABS Flame Retardant Rating (12V SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe.Back up time 30 Min at full load.Warranty : One Year on UPS and One Year on SMF Battery on site against any manufacturing defects. Certificate ISO 9001:2015, ISO 14001:2015, IOS 18001,OHSAS 18001. CE Certification: IEC/ EN 62040-1-1, IEC/EN50091- 1,IEC/EN 60950(Safety),IEC/ EN 5009 I- 2,IEC/ EN 62040-2 (EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000-4(EMC Emmunity) & IEC/ EN 60146 (Design & Manufacture) (Make: APC-Schneider Electric / NUMERIC/ Power One/ VERTIV/ Switching AVO/ Powersafe / Delta)
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [17/ D-12]
M/S. P K ENTERPRISE (BID ID -6714682)
SUPER BUILDERS (BID ID -6714646)
ORIENT ENGINEERING WORKS (BID ID -6716350)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .