Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹8.0 L+₹7,582.68 (0.96%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L2 | Rejected-Finance higher than L1 | |
| 3 | L3₹8.0 L+₹11,453.75 (1.45%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L3 | Rejected-Finance higher than L1 |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
10 Dec 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_NTKMD_PHED
Utility_Bldg__Beside_Delhi_Public_School_AA_ID_New_Town_Kol_700156
Overhauling_of _vertically_executed_Sewage_Pumping_machineries_with_allied_electrical_works_at_SLS-I_AA-IIIA_under_NTK_Project
2022_PHED_426304_16
PHE/NTKMD/e-08 of 2022-23
Open Tender
Project Work
Item Wise
15 days
work
Please refer Tender documents.
3 documents required · 3 mandatory
₹17,000
11 Jan 2023
25 Nov 2022
12 Dec 2022
26 Nov 2022
10 Dec 2022
27 Nov 2022
Amount
250kW Sewage Pump
Dismantling & taken out vertical 250kW motor from motor tool base on working platform after disconnection of all power lines by expert mechanic with the help of chain pulley as per direction of EIC.
Withdrawing of 250kW Kishor make defective Sewage pump in underground basement the pump house by existing lifting arrangment after decoupling the pump motor as per direction of EIC.
Dismantling the pump portion of the above pump motor set part by part for detection of fault as per direction of the EIC.
Cleaning , servicing of the 250kW vertical executed sewage pump and taken out the dirty materials from inner side of pump like that poly thene, parts of plastic, jute etc. by expert mechanic.
Supply, delivery at site and storage of the following item :
Bearings (DE & NDE) No. 7326B (SKF-Imported)
Re-assembling the pump portion part with the help of existing serviciable spares and newly supplied spares of item Sl. No. 6.01 above as per direction.
Installtion of the repaired pump motor set in its existing position inside the sewage pump house with the help of existing lifting arangement including recoupling the pump with the existing motor and reconnection of all power lines as per direction.
Testing of the newly installed pump motor set on full load condition as per full satisfaction of EIC.
37kW Sewage Pump
Dismanlling & taken out vertical 37kW motor from motor tool base on working platformar after disconnection of all power lines by expert mechanic with the help of chain pulley as per direction of EIC.
Withdrawing of 37kW Kishor make defective Sewage pump in underground basement the pump house by existing lifting arrangment after decoupling the pump motor & disconnection of all power lines as per direction of EIC.
Dismantling the pump portion of the above pump motor set part by part for detection of fault as per direction of the EIC.
Cleaning , servicing of the 37kW vertical executed drainage pump and taken out the dirty materials from inner side of pump like that poly thene, parts of plastic,jute etc by expert mechanic.
Supply of the following items :
Ball bearing Part No. 7317B
Pump Shaft (SS)
Shaft Sleeve (SS)
Re-assembling the pump portion part with the help of existing serviciable spares and newly supplied spares of item Sl. No. 15.00 above as per direction.
Installtion of the repaired pump motor set in its existing position inside the sewage pump house with the help of existing lifting arangement including recoupling the pump with the existing motor and reconnection of all power lines as per direction.
Testing of the newly installed pump motor set on full load condition as per full satisfaction of EIC.
Sump Pump
Withdrawing of 3.5kW Kishor make defective submersible dewatering pump motor set from its existing position after disconnection of all power lines as per direction of EIC.
Carrying of the defective submersible dewatering pump motor set as above from work site to our Kolkata workshop by hired vehicles for repairing as per direction of EIC.
Dismantling the submersible dewatering pump motor set part by part as per direction of the EIC.
Supply of the following items :
Mechanical Seal MG-1, 25 mm
O' Ring set
Oil Seal (25-62-10)
Lubricating oil, Servo
Ball bearing Make : SKF, Sl. No. 3305
Alankey bolt (8 mm x 20 mm)
Alankey bolt (8 mm x 25 mm)
Alankey bolt (6 mm x 16 mm)
Bolt (8 mm x 30 mm)
Rewinding the motor by supplying PVC insulated copper wire of suitable size after replacing burnt out cable.
Reassembling the pump motor set part by part with the old servicable spares & new spares as mentioned in Sl. No. 23.00
Recarriage of 1 no. repaired submersible dewatering pump motor set as above from our Kolkata workshop to the work site by hired vehicles as per direction of EIC.
Installation of the repaired submersible dewatering pump motor set in its existing position inside the sewage pump house including reconnection of all power lines as per direction.
Testing of the newly installed submersible dewatering pump motor set on full load condition as per full satisfaction of EIC.
450 mm dia sluice valve
Disconnecting the power and control cable from the actuator mounted on 450 mm dia sluice valve, taken out the actuator from the valve gear box & placing the same to the working platform of pump house with help of derrick as per direction of EIC.
Dismantling the valve bonnet and taken out the internal parts part by part for repairing by expert mechanic.
Repairing damaged wedge & stem by carrying the same to machine shop.
Replacement of gland packing, gasket for bonnet, nuts, bolts etc.
Thorough cleaning the valve body & internal parts by sand papering, cleaning the foreign particles wihin the sluice valve as per direction of EIC.
Re-assembling the internal parts like disc, wedge, stem, stuffing box, gland flanges, lock nut, yoke, hand wheel, nut, bolts, washer, gasket etc. for the above valve including greasing of movable parts. set part by part including greasing of movable parts by expert mechanic.
Re-fixing the actuator along with electrical connection, testing & commissioning.
Supply & delivery of the following :
Transformer oil
For HT panel : Thorough testing and calibration of 11KV VCB 3 Panel distribution board at site A) Cleaning of entire panel by carbon cleaner to remove all carbon particles and sulphation to improve insulation resistor (IR). B) 11KV Breaker completely servicing, cleaning by CRC & checking of all parts and make it in proper condition. C) IR value checking of PT & CT. D) All over current and earthfall relays tested by secondary injection. E)Tripping test of Breaker by primary injection. E)Tightness checking of all incoming & outgoing cables of breaker & transformers and Cable end termination to be cleaned by carbon cleaner. For LT (PCC) panel : A) Thorough cleaning of entire PCC panel & lighting. B) Testing & servicing of Air Circuit Breaker C) Testing of all MCCB, SFU, CT etc. D) All tightness checking.
Dehydration & filtrtation of 1 no, 11/0.433KV 1000 KVA transformer oil of the existing trasnformer (2 nos. x 900 ltr.)
Dielectric strength test as per specification of the IE rules (2 nos. 1000KVA transformer).
Transportation charges of filtration machine (to & fro).
GST @18% of Total Value in Amount
CESS @1% of Total Value in Amount
DAS ENTERPRISE
DEY ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .