Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.5 LAccepted-AOC AGGARSAIN CHOWK VILLAGE BHOJPUR POST OFFICE FETEHPUR SAHARANPUR ROAD YAMUNANAGAR HARYANA 135101 | YAMUNANAGAR | HARYANA | 135101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹57.4 L+₹92,666 (1.64%)Rejected-Finance HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | HARYANA | 134118 | L2 | Rejected-Finance Highest | |
| 3 | L3₹60.1 L+₹3.6 L (6.41%)Rejected-Finance HOUSE NO 966 URBAN ESTATE 2 125005 | HISAR | HARYANA | 125005 | L3 | Rejected-Finance Highest |
Tender Value
₹48.2 L
EMD Value
₹96,340
Closing Date
10 Mar 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. Of Haryana Govt. H.No. 1501 to 1512 (12 Nos.) in Sec.-39 at Chandigarh (1 Kanal) (Pdg. EI work) (Recall).
2022_HRY_206390_2
PWD/Elect-KNL/Elect-AMB/110230
Open Tender
Construction Works
Works
180 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹96,340
Yes
13 Jun 2022
25 Feb 2022
11 Mar 2022
25 Feb 2022
10 Mar 2022
25 Feb 2022
120 days
Amount
1 :- CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. 48" (1200mm) 20.71.1
2 :- Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge 20.72
3 :- COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group A 23.2.1.1
4 :- Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group A 23.2.2.1
5 :- Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A 23.2.4.1
6 :- Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A 23.2.5.1
7 :- Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) 23.5.6.1
:- 1 run of Size 4 Sqmm(1/2.24mm) 23.5.6.3
:- 1 run of Size 6 Sqmm(1/2.80mm) 23.5.6.4
:- 1 run of Size 10 Sqmm(1/3.50 mm) 23.5.6.5
8 :- Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. 23.6.6.1
:- MS pipe of 25 mm dia. 23.6.6.2
9 :- Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. 23.7.6.2
:- PVC pipe of 40 mm dia. 23.7.6.4
10 :- FITTING AND ACCESSORIES Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Bakelite angle/straight button holder large size. 23.8.1.12
11 :- Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data 23.8.10.1
:- 3 Modules 23.8.10.2
:- 4 Modules 23.8.10.3
:- 6 Modules 23.8.10.4
:- 8 Modules 23.8.10.5
:- 12 Modules 23.8.10.6
12 :- Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch 23.8.11.1
:- 5 amp 2 way switch 23.8.11.2
:- 15 amp 1 way switch 23.8.11.3
:- 5 amp Socket 23.8.11.4
:- 15 amp 6 pin Socket 23.8.11.5
:- Bell Push 23.8.11.6
:- Step type Fan Regulator 2 modules 300 watt 23.8.11.7
:- Telephone Socket outlet modular type 23.8.11.8
:- T.V. Socket outlet modular type 23.8.11.9
:- Blanking plate 23.8.11.10
:- 32A D.P. Main Switch With Key Ring Tag 2 Module 23.8.11.13
13 :- Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required 23.2
14 :- Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp 23.22.1.9
15 :- Supply and erection of sheet steel enclosures 1 Pole / 2 pole / 4 pole on wall/on existing pedestal complete with necessary connections etc, :- T.P.N enclosure suitable for TP, TPN or FP MCB 23.22.3.3
16 :- Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) 23.22.4.2
:- TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) 23.22.4.5
:- TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) 23.22.4.7
17 :- Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole 23.22.5.1
:- 40 amp to 63 amp. Double pole 23.22.5.4
:- 40 amp to 63 amp. MCB's TRIPLE POLE 23.22.5.6
:- 40 amp to 63 amp. MCB's FOUR POLE 23.22.5.8
18 :- Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. FP RCCB 30ma sensitivity , 63 A 23.22.6.6
19 :- Supply and erection of blanking sheet in existing distribution board. 23.22.7
20 :- Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire 23.23.8.1
21 :- Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required 23.23.9
22 :- EARTHING AND LIGHTENING ARRESTOR Earthing with G.I earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. 24.1.1
:- Extra for using salt and char coal/coke for pipe earth electrode as required. 24.1.2
:- Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. 24.1.11
:- Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. 24.1.13
23 :- Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 1.5 sqmm 24.2.6.1
24 :- S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Meter below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia 24.5.2.3
25 :- Supply of aluminium armoured cable of following size, Make as per approved list 16 Sqmm x 4 Core aluminium armoured cable NS-1 i)
:- 25 Sqmm x 4 Core aluminium armoured cable ii)
26 :- S/E of LED Bulk Head with die cast aluminium housing, opal diffuser with PC diffuser with E27 Cap, IP54 including all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work. Make-Jaguar NS-2
M/S GARG ELECTRICAL
Dandoria Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .