Loading…
Loading…
Tender Value
₹5.7 Cr
EMD Value
₹5.7 L
Closing Date
30 Apr 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Dy.Minicipal Commissioner - West Zone
CONSTRUCTION OF PHYSIOTHERAPY& YOGA BUILDING AT F.P.NO :- 287-2-2, T.P.NO :- 66 IN RANIP WARD, WEST ZONE, AHMEDABAD
298435
9/25-26 (T.N.72)
Open
Civil Works - Others
Ahmedabad
4 documents required · 0 mandatory · 4 optional
₹12,000
Municipal Commissioner, Ahmedabad
₹5.7 L
22 Apr 2026
22 Apr 2026
22 Apr 2026
30 Apr 2026
22 Apr 2026
Name of Work:- CONSTRUCTION OF PHYSIOTHERAPY& YOGA BUILDING AT F.P.NO :- 287-2-2, T.P.NO :-
66 IN RANIP WARD, WEST ZONE, AHMEDABAD
Bill of Quantities
I. No. Qty Items Per Amount
Civil Work Estimate
1.0 Demolition & Dismantling work
Demolition of RCC work using Hydra Breacker
including stacking of servicable materials and
a 20.00 disposal of unservicable materials with all lead 1047.38 Cu.M.
and lift.Removal Of Existing Building
Foundation and Super Structure If Any.
Demolition of Brick work and stone masonry
including stacking of serviceable materials and
disposal of unserviceable materials with all
lead and lift.(ii) In Cement Mortar.Removal Of
Existing Building Foundation and Super
Structure If Any.
Dismentaling of sheet roofing including ridges,
Hips, Valleys, Gutters etc. stacking of
serviceable materials and disposal of
unserviceable materials with all lead and lift.
i 5.00 (i) G.I.sheet roofing. 47.25 Sq.mt
ii 5.00 (ii) A.C. sheet roofing. 53.55 sq.mt
Dismentling steel work including distempering
d 2000.00 and stacking the materials with all lead and 3.63 Kg.
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
e 2.00 architraves, hold fasts and other attachment 185.85 Each
etc. complete and stacking them with in all
lead and lift. (i)Notexceeding 3 Sq.M. in area.
Removing & Scrapping of Old deteriorated
Plaster of any thickness from Masonary /
f 200.00 R.C.C. member including stacking of 19.38 Sq.M.
serviceable material & disposal of un
serviceable from site of work with all lead & lift.
Dismentaling any type tiled of stone floors laid
in mortar including stacking of serviceable
materilas and disposal of unserviceable
materials with all lead and lift.
Excavation for foundation including sorting out
stacking of useful material & disposing of
excavated stuff upto 50 mt. lead. Loose & Soft
soil.Excexuted With Mechanical Effort
a 2127.00 up to 1.5 mt. depth 115.92 Cu.M.
c 1114.00 3.0 to 5.0 mt. depth 141.11 Cu.M.
Add extra for Disposing off the excavated stuff
of above items for lead of (A) 50 m to 100 m
Add extra for Disposing off the excavated stuff
of above items for lead of (B) 100 m to 200 m
Providing and installing cast in situ single
under reamed piles of specified diameter and
length below pile cap, excluding the cost of
Concrete, steel reinforcement but including the
f cost of boring with bentonite solution and the
length of the pile to be embedded in pile cap
etc. all complete. (Length of pile for payment
shall be measured upto to the bottom of pile
i 20.00 400 mm dia. Piles 638.83 Rmt.
ii 20.00 450 mm dia. Piles 705.03 Rmt.
Extra over single under ream for providing
additional bulbs in under reamed piles, under
g specified diameter excluding the cost of
Concrete, steel reinforcement (only the nos. of
extra bulbs are to be paid).
t 2.00 400 mm dia. Piles 813.05 Each
ii 2.00 450 mm dia. Piles 1103.43 Each
Provdg. & laying cement concrete 1:5:10 (1
cement : 5 course sand : 10 hand broken
3a 1.00 aggregates 40 mm nominal size) and curing 2492.52 Cu.M.
complete, excluding cost of form work in
foundation & Plinth.
Provdg. & laying cement concrete 1:3:6 (1
cement : 3 coarse sand : 6 hand broken stone
aggregates 40 mm nominal size) and curing
complete excluding cost of form work in
514.00 (A) Foundation and plinth 2976.00 Cu.M.
Supplying of graded hand brocken stone size
of 90 mm to 127 mm at site (Rubble or Spoul)
Labour charges for spreading the spouls
mm to 127 mm thick layer good earth filling in
voids correcting the grade & camber comp.
with rolling, watering, incl. preparing
thesurface by brushing for removing all loose
or dirts ect.comp.
Provdg. & laying cement concrete 1:4:8 (1
cement : 4 coarse sand : 8 hand broken stone
4.0 5.00 aggregates 40 mm nominal size) and curing 2653.67 Cu.M.
complete excluding cost of form work in
foundation& plinth.
Filling available excavated earth (excluding
rock) in trenches, plinth, sides of foundations
5.0 4650.00 etc. in layers not exceeding 20 cm. in depth 129.10 Cu.M.
consolidation each deposited layer by
ramming and watering.
Conveyance charges of earth lime, murrum,
building rubbish, manure, garbage, sludge,
excavated rock, fly ash, aggregate of any kind
a 200.00 Conveyance charges 0 km to 1 km 46.63 Cmt
b 100.00 Conveyance charges 0 km to 2 km 60.69 Cmt
c 4500.00 Conveyance charges 0 km to 5 km 100.44 Cmt
Extra For Lead on Above Item Above 5 km &
Extra For Lead on Above Item Above 6 km &
Extra For Lead on Above Item Above 7 km &
Extra For Lead on Above Item Above 8 km &
h 4500.00 Extra For Lead on Above Item Above 9 km 9.26 Cmt
Filling in plinth with sand under floors
7a 15.00 including watering, ramming, consolidating, 455.63 Cu.M.
compacting and dressing etc. completed.
Filling in foundation and plinth with murrum or
selected soil in layers of 20 cm. thickness
including watering, ramming and consolidating
Brick work using common burnt clay building
bricks having crushing strength not less than
35 kg/Sq. cm. in cement mortar 1:6 (1 cement
: 6 fine sand) conventional brick
a 106.00 (a) in foundation & Plinth 3981.21 Cu.M.
b 311.00 Super structure Upto Floor Two Level 4253.46 Cu.M.
c 64.00 Super structure Above Floor Two Level 4293.55 Cu.M.
I.Half brick masonry in common burnt clay
building bricks having crushing strength note
9.0 less than 35 Kg/Sq. Cm. in cement mortar 1:4
(1 cement : 4 coarse sand) using conventional
brick in Super structure upto floor Four level
a 245.00 All Floor Level 646.70 Sq.M.
Providing and laying controlled cement
concrete of M-25 Grade and curing complete,
10.1 Excluding the cost of form work, Scaffolding,
cost of reinforcement for reinforced concrete
work For any Height up to any FloorLevel.
a 70.00 Foundations,Raft,Footings,Mass concrete 4238.04 Cu.M.
b1 2.00 RCC Retaining wall at All Floor 4519.88 Cu.M.
Tie-Beam, Lintel , Beam- Bracket, Stair Case
c1 35.00 & Landing, Coping ,Slab, balcony, weather 4496.07 Cu.M.
shed, loft , any cantilever etc All Floor
d1 29.00 Columns,Pillars, posts and struts at All Floor 4593.91 Cu.M.
Providing and laying controlled cement
concrete of M-20 Grade and curing complete,
10.2 Excluding the cost of form work, Scaffolding,
cost of reinforcement for reinforced concrete
work For any Height up to Floor Four Level.
a 10.00 Foundations,Raft,Footings,Mass concrete 3977.88 Cu.M.
Tie Beam , Lintel , Beam- Bracket , Coping
b1 80.00 ,landing, Slab, balcony, weather shed, loft , 4460.36 Cu.M.
any cantilever etc at All Floor
c1 4.00 Column at All Floor 4558.20 Cu.M.
d1 1.00 Stair Case All Floor 5418.91 Cu.M.
Providing and laying in position Ready Mixed
M250 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to
site of work in transit mixer for all lead having
continuous agitated mixer, manufactured as
per mix design of specified grade for
reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of
laying with all lead and lift, excluding the cost
of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and
durability as per direction of the Engineer - in
charge. Without Fly Ash (Min cement level as
per latest IS 456 shall be maintained) (Cement
Providing and laying in position Ready Mixed
M200 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to
site of work in transit mixer for all lead having
continuous agitated mixer, manufactured as
per mix design of specified grade for
reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of
laying with all lead and lift, excluding the cost
of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and
durability as per direction of the Engineer - in
charge. Without Fly Ash (Min cement level as
per latest IS 456 shall be maintained) (Cement
Drilling suitable holes in reinforced or plain
cement concrete with power driven drill
machine to a minimum depth of 80mm upto
250mm in RCC beams, lintels, columns and
slabs to introduce steel bars for
sunshades/balconies including fixing the steel
bars in position using Hilti Chemical HY200-R
but excluding the cost of reinforcement, all
complete as per direction of Engineer-In-
a 200.00 8 mm Dia in 80 mm Deep & 12 mm Dia Drilling 183.52 Each
10 mm Dia in 100 mm Deep & 14 mm Dia
12 mm Dia in 120 mm Deep & 16 mm Dia
16 mm Dia in 160 mm Deep & 20 mm Dia
e 20.00 20 mm Dia in 200 mm Deep & 25 mm Dia 1024.44 Each
25 mm Dia in 250 mm Deep & 32 mm Dia
Providing and laying controlled cement
concrete 1:2:4( 1cement : 2 coarse sand :
Graded stone aggregate 20 mm nominal size )
and curing complete, Excluding the cost of
form work and reinforcement for reinforced
concrete work in:
Foundations, footings, base of columns,grade
slab and mass concrete.
slab, landing shelves, Balconies, lintels,
b 1.00 beams, girders, and cantilever, up to aany 4012.47 Cu.M.
P/A Trimix with dewatering machine and
floater machine on constructed R.C.C. work
incl. cost of machine and labour etc. comp. as
Making 15 mm Groove in R.C.C work on road
and filling it with poly sulfied selant and
finished it good incl. all labour charges etc.
comp. as directed
Providing and laying and fixing 25 mm thick
expansion joint by hydrocell semi rigid UV
e 9.00 resistance with high performance laminated 738.13 Sqmt
closed cell polythene foam joint filler in sheet
foam as directed, etc. complete.
Providing form work in ordinary timber
planking so as to give a rough finish including
centering, shuttering, strutting and propping
12.0 etc. height of propping and centering below
supporting floor to celling not exceeding 4 M &
removal of the same for in situ reinforced or
plain concrete work in
(A) Foundation, footings, bases of columns
etc. and mass concrete.
(B) Flat surface such as soffits of slabs,
landing and the like
(C) Vertical surfaces such as walls (any
thickness) partitions.
(D) Columns, pillars, posts & struts.
d 1518.00 (1) Square, rectangular, polygonal in plan 297.68 Smt
e 20.00 (2) Circular or curved in plan. 422.10 Smt
(H) (1) Sides and soffits of beam, haunchings
f 2214.00 cantilevers, girders, bressumers, Coping and 192.15 Smt
lintels not exceeding 1 M in depth.
(2) Sides and soffits of beam, haunchings
g 10.00 cantilevers, girders, bressumers and lintels 259.88 Smt
exceeding 1 M in depth.
(L) chullah hoops, weather sheds, chhajas,
carbels etc including edges.
(M) Staircase with-sloping or stepped soffits
incl. risers & strings excluding landing.
Extra for additional height of propping and
centering where the height of propping and
centering exceeds 4 .O M between supporting
floor to ceiling including temporary brick or
stone pillars for supporting as required.
(i)Height more than 4.0 M.and upto 5.0 M.
Providing T.M.T Fe 500D bar reinforcement for
R.C.C. work including bending, binding and
placing in position complete up to any floor
a 170262.55 All Floor Level 75.46 Kg.
Providing and laying polished Kota stone slab
(Polished / River Finish, Green colour ) flooring
over 20 mm. (average) thick base of cement
14.0 60.00 mortar 1:6 (1 cement : 6 coarse sand) or lime 982.83 Sq.M.
mortar 1:1.5 laid over and joined with grey
cement slurry including rubbing and polishing
complete.25 mm th.
Providing and laying polished Kota stone slab
25 mm. thick in Platform ,Riser of Stair
Skirting, Tread , dado and pillars laid on
15.0 40.00 mm. thick cement mortar 1:3 (1 cement : 3 1176.03 Sq.M.
coarse sand) jointed with grey cement slurry
including rubbing and polishing and MAking
groove where it is Required etc. compl
Providing and laying white/Colur glazed tiles
mm thick in flooring treads of steps and
16.0 5.00 landing laid on a bed of 12 mm thick cement 908.17 Sq. M.
mortar 1:3 (1 cement : 3 coarse sand) finished
with flush pointing in white cement.
Providing and layingWhite / Colour glazed tiles
of size 600 mmx300mm x 8 mm / 300 mmx
450mm x 8 mm in skirting, risers of steps,
Floor and dedo on 10 mm. thick cement
plaster 1:3 (1 cement : 3 coarse sand) and
jointed with white cement slurry.
Providing and laying marble stone slab flooring
over 20 mm. (Average) base of cement mortar
1:6 (1 cement: 6 coarse sand) or L.M. 1:1.5
laid and jointed with grey cement slurry
including rubbing and polishing complete: (A)
Marble slab 25 mm. thick.
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in flooring treads of steps and
19a 1130.00 landing laid on a bed of 12mm thick cement 1062.50 Sq. M.
mortar 1:3 (1-cement : 3-coarse sand) finishing
with flush pointing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in skrting risers of steps and
19b 650.00 dedo on 10mm thick cement plaster 1:3 1130.15 Sq. M.
(1cement : 3-coarse sand) and jointed with
white cement slurry
Providing and Fixing 18 mm thick concrete
base exposed brick cladding including surface
waterproffing, polymer modified tile adhesive
and polymer modifies tile grout ( grey / white)
with neccesary scafolding etc compl. As per
direction of engg. Incharge.
P & L 24" x 24" vitrified 8 mm thick tile flooring
20 mm (average) base of cement mortar 1:6 (
1cement: 6 coarse sand) on new surface or
19d 70.00 fixing on existing flooring by adhesive material 1383.99 Sq.M.
including dismentaling of existing flooring and
jointed with color cement slurry including
finised with flush pointing & cleaning the
surface etc. complete for Antiskid
Providing and Laying Tactile Tile (For Vision
Impaired Persons as per Strandards) of Size
300x300x9.8 mm Having with Water
Absorption less than 0.5% and Confirming to
is:15622 of Approved Make in all Colours and
Shades in for Outdoor floors such as footpath,
19e 70.00 Courtyard, Multi models Location etc., laid in 1663.72 Sq.M.
20 mm Thick Base of Cement Mortar 1:4 (
Cement : 4 Course Sand) in all Shapes &
pattern including Grouting the Joints with
White Cement mixed with Matching pigment
etc. Complete as per Direction of Engineer-in-
Providing and laying Ceramics tiles 6 to
mm thick in flooring, treads of steps, landing
20.0 10.00 and dedo on 12 mm. thick cement plaster 1:3 960.47 Sq. M.
(1 cement : 3 coarse sand) and jointed with
white cement slurry.
Providing & Laying 18 mm thick Mirror polish
granite For flooring , counter , stair -riser
tread , skirting , dedo , Jambs etc. machine cut
21.0 345.00 or chiselled on bed of cement mortar 1:1 2385.71 Sq. M.
pointing with neat cement slurry incl. moulding,
Making grooves where it is required etc. comp.
as per instruction of engineer in charge.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat on fair side of brick /
22a concrete walls for interior plastering upto any
Floor level and finished even and smooth in
i 2172.00 All Floor Level 190.58 Sq.M.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat plastering on ceilings,
Beam side and sofits of stairs upto any Floor
level and finished even and smooth in C.M.1:4.
i 1510.00 All Floor Level 215.15 Sq.M.
Providing & fixing 23 cm wide chicken mesh
jali with nails & then application of 15 mm
plaster on R.C.C. & masonary joints as per dir.
of engg. In charge.
Providing and mixing water proofing materials Per Bag
in cement mortar in proportion recommended of 50 Kg
by the manufacturer. etc. comp. as per of
instruction of engineer in charge. Cement
Providing 20 mm th. Double coat Sand face /
Mala Cement Plaster on Walls upto any Height
Above Ground level consisting of 12 mm th.
Backing coat of C.M. 1:3 ( 1 cement : 3 Ssand
) & 8 mm th. Finishing coat of C.M. 1:1 (
cement : 1 sand ) ets. Complete.
White / Color washing with lime on
undecorated wall surfaces (two coats) to give
24a 200.00 an even shade including thoroughly brooming 12.29 Sq.M.
the surface to remove all dirt, dust mortar
drops and other foreign matter.
Providing & Applying 3 mm thick External Wall
Rustic Type Texture as per Design & Make
24b 1400.00 as Approved by Consultants / Engineer in 424.92 Sq.M.
Charge. Work Includes All Necessary
Scaffolding Work upto Any Height.
Finishing walls with Acrylic Smooth exterior
paint of required shade :New work (Two or
24 c 3000.00 more coat applied @ 1.67 ltr/10 sqm over and 174.97 Sq.M.
including priming coat of exterior primer
applied @ 2.20 kg/10 sqm)
P./L. METALIC HERITAGE SURFACE
Providing and fixing of HERITAGE textured
homogeneous wall finishing system from
BAKELITE HYLAM LTD or equivalent make
consisting of a two component system of (25
kgs per Pack) made of 92% silica particles
coated with fade resistant pigments, 100%
acrylic polymer bonding agent (5kgs per pack)
24d 30.00 with the applied thickness of the coating being 637.38 Sq.M.
between 0.8mm-1.2mm to be applied on
acured, smooth level plaster without keying, as
per the shades/combinations approved, as per
the manufacturer directions, for usages, tobe
applied by an approved applicator of the
manufacturer, as per the directions /
supervision of the engineers in charge, all
complete. Includes All Necessary Scaffolding
Work upto Any Height.
Wall Painting (two coats) with plastic emulsion
/ Oil paint of approved brand and manufacture
and of shade required on undecorated wall
surfaces to give an even shade, over and
including a priming coat with alkali resistance
primer of approved brand and manufacture
after thoroughly brushing the surface free from
mortar droppings, and other foreign matter and
also including preparing the surface even and
sand -papered smooth
Extra over above item for every subsequent
b 3000.00 coat of of wall painting with plastic emulsion / 33.39 Sq.mt.
Oil paint of approved brand.
Applying two coats of Birla (white cement
based) or Asian (acrylic lapy-putty) or
equivalent & two coats of primer of approved
brand and manufacture on new wall surface to
give an even shade including thoroughly
brushing the surface free from mortar dropping
and other foreign matter and sand papered
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
mt.,refilling, trasporting the pipe to work site,
unloading, lowering in trenches, laying and
jointing the pipes in c.m. 1:1 incl. all jointing
26.0 materials such as cement, sand, hemp,
bitumen as dire. testing the pipe line to a head
of 1.5 mt. and hydraulic test as dire incl.
watering trenches, spreading , and carting
away of surplus earth within 100 mt.lead as
dire. etc. comp.
a 70.00 23 cm dia. 344.64 Rmt
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
mt.,refilling, trasporting the pipe to work site,
unloading, lowering in trenches, laying and
jointing the pipes in c.m. 1:1 incl. all jointing
materials such as cement, sand, hemp,
bitumen as dire. testing the pipe line to a head
of 1.5 mt. and hydraulic test as dire incl.
watering trenches, spreading , and carting
away of surplus earth within 100 mt.lead as
dire. etc. comp.
b 20.00 15 cm dia 211.05 Rmt
c 15.00 10 cm dia. 288.23 Rmt
Constructing brick masonry chamber for under
ground C.I. Inspection chamber and bends
with bricks having croshing strength not less
than 35 Kg. Cm2 in C.M. 1:5 C.I. cover with
frame (Lightduty) 455mm x 610 mm intenal
dimensions total weight of cover with frame to
be not less than 38 Kg. (Wt. of cover 23Kg.)
27.0 20.00 and Wt. of frame 15Kg.) (R.C.C.top slab with 3863.85 No.
1:2:4 mix (1-cement:2-coarse sand:4-graded
stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15 mm thick with
cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed
concrete etc. complete.(i) Inside dimensions
455 mm x 610 mm and up to 850 mm deep
Constructing Manhole with R.C.C. top slab in
1:2:4mix (1-cement: 2-coarse sand:4-graded
stone aggregate 20 mm nominal size)
foundation concrete 1:3:6 mix (1-cement:3-
coarse sand:6-Brick bats 40+50mm size)
inside plastering 15mm thick with Cement
Mortar 1:5 (1-Cement:5-coarse sand) finished
with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-
Cement:2 -Coarse sand:4-stone aggregate
28 a 3.00 mm nominal size) finished smooth complete 19139.07 No.
including curing and festing (i) Inside size
900mm x 1200mm and up to 1.5M. deep
including C.I. cover with frame size 560 mm
diameter total weight of cover and frame to be
not less than 128kgs. (Wt. of cover 64Kg. and
Wt. of frame 64Kg.) (A) With 230 mm thick
walls of brick masonry using brick having
crushing strength not less than 35Kg./Sq.cm.
in Cement Mortar 1:5 (1-Cement: 5-Coarse
sand) (2)B type depth up to 1.50 Metre
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal
basin of 340x280x470 mm sizes respectively
with standard flush pipe, Waster Pipe, Waste
29a 16.00 Coupling, PVc Connection and G.I clamps 3344.35 No.
complete, including painting of fittings and
brackets, cutting and making good the walls
and floors wherever required : Cera Model No.
S4020103 or Equivalent
Providing and Fixing of C.P. Brass BIB Cock of
15 mm Dia of Jaquar make florentine series
b 25.00 model no. 5047n or equivalent make with all 1564.17 No.
necessary fittings. as approved by Engineer -
Providing and fixing brass screw down Angle
stop tap.(A) 15mm dia. Of Jaquar make
c 25.00 florentine series modelno. 5053n or equivalent 1160.57 No.
make with all necessary fittings. as approved
by Engineer - in - charge.,
Providing and fixing C.P. brass shower rose
d 2.00 with 15mm or 20mm inlet Shower Arm.(A) 279.37 No.
100mm dia. Each
Provding and Fixing of autoclosing pressmatic
pillar cock / bib cock with all necessary fittings
of Polished Bright Chrome Finish of Jaquar
e 4.00 make model no. 031L65 or equivalent make as 3280.52 No.
approved by Engineer in Charge. Rate
including of cost of labour, material etc. in
complete manner.
Providing and Fixing of C.P. Brass Two Way
Bib Cock of 15 mm Dia of Jaquar make model
f 10.00 no. 041kn or equivalent make approved make 1411.58 No.
with all necessary fittings. as approved by
Engineer - in - charge.,
Providing and Fixing of C.P. Brass urinal Valve
Auto Closing System With Full Built in Control
Cock & Wall Flange of 15 mm Dia of Jaquar
make model no. 077 or equivalent make
approved make with all necessary fittings. as
approved by Engineer - in - charge.,
Provdg. & laying S.W. Gully trap with C.I.
garting brick masonry chamber & water tight
30.0 10.00 C.I. cover with frame of 300 mm x 300 mm 1234.57 No.
size ( inside) with standard weight. sqare
mouth trap size 150 x100 mm P trap
Providing erecting and fixing double coated ISI
water tank of required capacity each with all
necessary fittings and connection etc.
complete on terrace
Extra rate over item of excavation of earth for
excavation of asphalt pavement/RCC of
thickness up to 0.20 meter including
32.0 20.00 demolishing the asphalt carpet, metal, soiling / 71.43 Sq.M.
cutting Reinforcement etc.comp. with stacking
the material as directed.-up to 0.20 meter
Providing and fixing PVC SWR Nahni trap IS
14735 for drain - 100 mm diameter with jali of
33.0 25.00 following nominal diameter of self cleansing 565.43 No.
design with C.I scread down or hinged grating
including the cost of cutting and making good
Provdg. And fixing Concealed / Open to wall,
ceiling & floor in true line and level UPVC pipe
Schedule- 40 of make as approved by engg.
incharge. pipe shall be fix on wall with the help
of clamp at every twi meter center to center of
shall be concealed as directed in cluding
neccesarry fitting etc. in cluding testing of pipe
and jointd and fixing the same with adhesive
solvent , including cost of all materials of
following nominal bore
iii 15.00 32 mm 117.97 Rmt
Providing and fixing concealed center point to
wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF)
seal for potable water of following dia. nominal
bore tube fittings and clamps including making
good the wall, ceiling and floor etc. complete
iii 5.00 25 mm 247.25 Rmt
Provdg. And fixing to wall ,ceiling and floor
10.00 kg. F/Sq.Cm2 working pressure
polythelene pipes of the following outside
diameter, low, density, complete with special
flange compression type fittings, wall clips etc.
making good wall ceiling and floor.
b 40.00 (A) 75mm dia 274.68 Rmt
Providing and fixing water closet squatting Pan
( Indian type W.C. Pan) size 580mm
(A)VitreousChina. (I)Long pattern = White
colour with Trap and Pair of Foot Rest
Providing and fixing white vitreous china
extended wall mounting water closet of Cera
37a 14.00 Make S1043101 Carat Model Or Equivalent 12613.27 No.
Model With EWC Soft Close Seat Cover, Chair
Bracket, nuts, bolts and gasket etc complete.
Providing and fixing chromium plated brass
b half trun flush cock of approved quality
including fixing in pipe line etc. complete.
Providing and fixing Health Faucet of Jaquar
make model no. 573 oe equivalent make as
approved by engg. In charge with flexible tube
upto 1 metre long etc. complete.
Providing and fixing 24"x18"x8" Carysil
Elegance or Equivalent Make of Single Bowl
38a 2.00 Sink S.S. Matt Finish With Waste Coupling, 7960.60 No.
Waste Pipe,etc. cutting and making good the
walls wherever required.
Providing and fixing Under counter Wash
basine including 15 mm C.P. Brass Pillar tap,
32 mm C.P. Brass Waste of Standard make,
Include All Accessaries, Cutting & Making
good the wall / granite Wherever Required in
White Color : Model S2030101 of Cera Clair
Series or Equivalent make Waash basine of
size : 520x450 mm
Providing and fixing Wall Hung wash basin
Including 32 mm C.P. brass waste of standard
pattern, Include All Accessaries, cutting and
c 4.00 making good the walls / granite wherever 3825.20 No.
require:In White Color : Cera Cadal Or
Equivalent Make Wash basin of size 515 x
Provdg. & fixing 600mm x 450 mm Bevelled
edge mirror of superior glass mounted of .6
39a 10.00 mm th. A.C. sheet or plywood sheet and fixed 825.48 No.
to wooden pluge with C.P. brass screws and
Provdg. & fixing C.P..Brass towal rail
complete with C.P. brass brackets fixed to
wooden plugs with C.P. Brass screws.(600
mmx 20 mm size)
Providing and fixing ball valve (brass) of
41 approved quality, High or low pressure, with
plastic floats complete :
ii 1.00 20 mm dia 1099.94 No.
iii 16.00 25 mm dia 1552.93 No.
iv 8.00 40 mm dia 3312.60 No.
Providing and fixing Full Way valve (HEX)
with wheel of approved quality :
i 2.00 15 mm Full Way valve (HEX) 1461.17 No.
ii 1.00 20 mm Full Way valve (HEX) 1924.61 No.
iii 10.00 25 mm Full Way valve (HEX) 2535.55 No.
iv 1.00 32 mm Full Way valve (HEX) 3377.64 No.
v 6.00 40 mm Full Way valve (HEX) 4661.10 No.
vi 2.00 50 mm Full Way valve (HEX) 6675.14 No.
Providing and Fixing of C.P.Brass Pillar Cock
of 15 mm Dia of approved make with all
necessary fittings. as approved by Engineer -
Providing fixing of SS grab bar with all
hardwares for Physically Handicap toilet.
Providing and laying integral cement based
water proofing treatment including preparation
44a 665.00 of surface as required for treatment of roofs, 1150.48 Sq.M.
balconies, terraces etc consisting of following
(a) Applying a slurry coat of neat cement using
2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS.
and approved by Engineer-in-charge over the
RCC slab including adjoining walls upto
mm height including cleaning the surface
before treatment.
(b) Laying brick bats with mortar using broken
bricks/brick bats 25 mm to 115 mm size with
50% of cement mortar 1:5 (1 cement :
coarse sand) admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineer-in-charge over 20 mm
thick layer of cement mortar of mix 1:5 (1
cement :5 coarse sand ) admixed with water
proofing compound conforming to IS :
and approved by Engineer-in-charge to
required slope and treating similarly the
adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a
second coat of cement slurry using 2.75 kg/
sqm of cement admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge.
(d) Finishing the surface with 20 mm thick
jointless cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge
(e) The whole terrace so finished shall be
flooded with water for a minimum period of two
weeks for curing and for final test.“All above
operations to be done in order and as directed
and specified by the Engineer-in-Charge :and
shall be guaranteed for minimum period of
years after handing over the completed
building by the main contractor to be finished
as directed. Stamp paper guarantee 10 years
to be furnished before receiving any payment
from the client.
With average thickness of 120 mm and
minimum thickness at khurra as 65 mm.
Providing and laying broken chine mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be
b 665.00 tempered to bring mortar creme out upto 739.89 Sq. M.
surface using white cement including
rounding off junctions and extending them upto
15 cm along the wall,clearing with water and
oxalic acid etc. as directed.
Providing and applying fibre reinforced
elastomeric liquid water proofing membrane
with resilient acrylic polymers having Sun
Reflectivity Index (SRI) of 105 on top of
concrete roof in three coats @10.76 litre/
sqm. One coat of self-priming of elastomeric
waterproofing liquid (dilution with water in the
c 350.00 ratio of 3:1) and two coats of undiluted 562.40 Sq. M.
elastomeric waterproofing liquid (dry film
thickness of complete application/system not
less than 500 microns). The operation shall be
carried out after scrapping and properly
cleaning the surface to remove loose particles
with wire brushes, complete in all respect as
per the direction of Engineer-in-Charge.
Filling in Sunken Portion with good Quality
Aerated light weight concrete block having
crushing strength not less than 35 kg/sqcm
and where directed by the Architect /
Engineer-in-charge, in sunk in layer. including
watering, ramming where it is required etc.
complete, as directed by the Architect /
Engineer-in-charge .
Providing and laying cement concrete flooring
( I.P.S.) 1:2:4 (1-cement : 2-coarse sand : 4-
45.0 100.00 graded stone aggregate 20mm nominal size) 348.08 Sq.M.
laid in one layer and finished with a floating
coat of neat cement. (B) 50mm thick.
Providing and fixing M.S. grills/ Gate of
required pattern to wooden/ Granite frames of
windows etc. with M.S. flats at required
46a 5500.00 spacings and frame alround, square or round 100.17 Kg.
bars with round headed bolts and nuts or by
screws all complete as per the structural
designs and directions of Engineer in charge
Providing & Fixing Structural steel work (
Confirming to IS 4923-1997) riveted, bolted or
welded in builtup for all type sections, in
framed work, including cutting, hoisting, fixing
in position and applying a priming coat of
approved steel primer all complete as per the
structural designs and directions of Engineer in
Applying priming coat over new steel and other
metel surface after and including preparing the
surface by throughly cleaning, oil, grease, dirt
c 400.00 and other foreign matter and scoured with 34.34 Sqmt
brushes fine steel wood, scrapers and sand
paper with ready mixed priming paint brushing
Painting two coats (excluding priming coat) on
new steel and other metal surface with enamel
paint, brushing, interior to give an even shade
including cleaning the surface an even shade
including cleaning the surface of all dirt, dust
and other foreign matter.
Providing & Fixing 1 mm Thick S.S.-304 Grade
90 mm High S.S. Railing having Hand Rail
Member of 50 mm Dia., 3 No. of Horizontal
Pipe of 16 mm Dia. & Baluster Suppprt of
mm Dia. At Every Third Step as per Detail
Given. Rate Includes All Work Complete as
per Description & as per Direction of Engg. in
Providing and fixing in position collapsible
steel shutters with vertical channels 20x10x2
mm braced with flat iron diagonals 20x5 mm
size with top & bottom rails of T-iron 40x40x6
mm with 38 mm dia. Steel pulleys complete
with bolts , nuts , locking arrangement
stoppers , handles including applying a priming
coat of red lead paint.
Providing corrugated 0.80 mm (22 gauge)
thick G.I. sheets roofing fixed with galvanized
iron ‘J’ or ‘L’ hook bolts, and nuts 8 mm. dia
with bitumen and G.I. limpet washers filled with
white lead complete excluding the cost of
purlines, rafters and trusses.
Providing valleys 900 mm. overall in plain
mm. thick G.I. sheet Class – 3 fixed with ‘J’ or
‘L’ hook bolts and nuts galvanized from ‘J’ or
‘L’ hook bolts and bitumen washers complete.
Providing and fixing rolling shutters of
approved make made of 80 mm wide M.S.
laths inter-locked together through their entire
length and jointed together at the ends by end
locks mounted on specially designed pipe
shaft with bracket plates, guide channels and
arragements for inside and outside locking
with push-pull operation including the cost of
hood cover and spring etc. complete.(A)
Shutters having width below 3.5 M.
Providing and fixing rolling shutters of
approved make made of 80 mm wide M.S.
laths inter-locked together through their entire
length and jointed together at the ends by end
locks mounted on specially designed pipe
shaft with bracket plates, guide channels and
arragements for inside and outside locking
with push-pull operation including the cost of
hood cover and spring etc. complete. (B)
Shutters having width 3.5 M. and above
Providing and fixing 27mm domal Series -
mm Th. Alluminium Section Three track Sliding
window With Metalic Powder Coating and
MM Clear Glaas(Non Tuffen) Include All
Accessaries and Fixture etc. complete as per
the direction of Engineer-in-charge.
Providing and fixing 27mm domal Series -
mm Th. Alluminium Section Two track Sliding
window With Metalic Powder Coating and
MM Clear Glaas(Non Tuffen) Include All
Accessaries and Fixture etc. complete as per
the direction of Engineer-in-charge.
ALUMINIUM DOOR WORK
Providing and fixing Aluminium Door work
(Single Shutter OR Double Shutter with or
without fix glass) made from Jindal or
equivalent make Powder Coated (50 micron
pure polyester coating ) ,aluminium section
frame built up standard tubular and other
section of approved make confirming to IS
and IS 1285 , member size with shutters of
horizontal member , vertical member
Confirming to IS733 and IS 1285 fixed with
rawl plug abd screws or fixing clips or with
expansion hold fasteners including necessary
filling up of gaps at junctions at top bottom and
c 37.00 sides with required PVC/ Neoprene felt, 8/12 5401.70 Sq. M.
mm toughened glass of approved make etc.
Aluminum sections shall be smooth, rust free,
straight.mitred and jointed mechanically
wherever required including Door Hardware
such as cleat angles aluminum snap beading
for glazing /paneling, CP Brass/ Stainless steel
screws, Stoppers, heavy duty floor hing, S.S.
Hinges, aldrop , Locking system, heavy duty
Floor Springs, Pivot and fixtures and
transparent silicon sealant glass fixing to frame
as per details all complete as per architectural
drawings and the direction of Engineer in
Charge. rate incl. all type of alumnium sections
for doors as per the detail Architectural dwg.
Providing and fixing standared extruded of
alluminium section of size 63 mm x 38.10 mm
x 1.2mm (Section:2434, @ Wt.0.643Kg/mt )
with colour anodized alluminium frame for
ventilation with 5 mm thick frosted glass as
details etc complete for Ventilation
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x
mm ( Section no: 4605, @Wt 1.094 Kg / Rmt
with colour anodized alluminium frame with
mm thick transparent bronze colour tinted float
glass as details etc complete for Fix window.
Providing Fixing 1.2 mm thick Alluminium
Section Partition -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
50c 36.00 Having Size of Section of 2.1/2 x 1.1/2 with 4 3124.44 Sq.mtr.
mm Compact Sheet / 5 mm thick Glass Fixing
with 4 mm thick EPDM Rubber etc. Complete
as per Direction of Consultant / Engg.incharge.
Providing Fixing 1.2 mm thick Alluminium
Section Partition Door -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled , frame
Having Size of Section of 2 .1/2 x 1 .1/2 and
Door Section Having Size of Tips Vertical
.3/4 x 1 .3/4, Top Rail 4 x 1 .3/4, Middle Rail
1 .3/4 x 1 .3/4, Bottom rail 4 x 1 .3/4 with
mm Compact Sheet / 5 mm thick Glass Fixing
with 4 mm thick EPDM Rubber Including Lock,
Handle, Door Closer, Door Stoper, Stopper etc
Complete as per Direction of Consultant /
Providing and fixing Structural Glazing with
using the 17 Micron anodised of approved
colour alluminium section as transium, mullium
of size 63mm x 38mm x 2 mm with using
mm thick reflective structural glass of
approved make, colour / Tinted, toughned and
shade and fixed with silicone sealant and
spacer tap and at corner sealed neoprene
foam dust and Air sealed gasket mirred
including scaffolding, cleaning of glass
etc.complete at all heights anf lifts with all
necessary fitting and fixtures, anchore
51a 50.00 fasteners, necessary M.S. or Aluminium 3953.75 Sq.mt.
brackets, suitable design for openable or
sliding window as per Architectural drawing
and as directed by Engineer-in-charge.
Grooves between the glasses to be filled with
sealant of Dow corning - structural sealant
995, weather sealant 789. The entire facade
should be water proof. The mullions are to be
connected to bracket by SS-304 nut bolts.
Measurement shall be given as per actual
execution of the work. (Rate are included
providing & fixing of MS structure steel work
wherever Required)
Providing and fixing wall acoustical paneling
using ecotone Slato/ Anutone slato or
equivalent Acoustic Panel make Slats L-16 of
size 128mmx2430mmx16mm thick up to
2400mm high as per the following specification
:-Slats L-16- 2mm @16mm, 32 x 128 x
mm high grade Pine wood base Medium
Density Fiber acoustic boards with Tongue &
Groove Edge,2mm slot perforation @ 16mm
centre, slates perforations, This Work Includes
Providing and Fixing of Rockwool Insulation of
48 Kg Density and 50 mm Thickness, The
acoustic should be furnished with a Black
51b 270.00 absorbent felt backing with an airflow 3526.02 Sqmt
resistance of 330-460 Ns/m³ (DIN
53887),wood practical core,NRC : should be
Up to 0.75,should meet the safety
requirements of EN 14190. Fixing :- Sound
Strut CC18 screw fixed horizontal/vertical to
wall at every 600mm c/c. Metal cleat can be
fixed on top edges of Sound Strut CS55 fixed
directly by stamping to the CS55 and IC91
which is screw fixed directly to the wall where
ever required with a backing black color fabric
as approved by Architect and as specified
including all accessories, material & labor
complete as directed by Architect / Engineer.
Providing and fixing ISI marked 35 mm thick
flush door shutters conforming to IS :
(Part I) decorative type, core of block board
construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with
vertical grains or cross bands and face
veneers on both faces of shutters with
52a 35.00 mm thick Decorative Laminated Sheet on both 4332.15 Sq.mt.
faces of shutters including ISI marked
Stainless Steel butt hinges, bright /matt
finished 125 mm Stainless Steel handles of
approved quality & make, ISI marked oxidised
M.S. door latches / Aldrop Conforming to
IS:5930 with necessary screws etc. complete
as per direction of Engg. incharge.
Providing wood work in frames of Doors,
windows cleare story windows and othersimilar
works wrought, framede and fixed in position. Cu.Decim
(A) Indian Teak Wood
Providing and fixing 35 mm th. Shutters for
doors windows & clearstory windows incl.
wood frames as specified 12 cm. x 7cm. size
incl. anodised alluminium fixtures and
fastenings including primer coat of approved
quality and two coats of oil paint etc. complete.
a 3.00 Fully glazed 4788.50 Sq. M.
b 3.00 Fully panelled 5478.89 Sq. M.
c 3.00 Partly panelled and partly glazed 5133.69 Sq. M.
Providing and Fixing FRP FRAME size 125 x
65 mm and 35 mm thick FRP shutter with
wood grain raised pannel design finish shutter
having extra reinforcement on sides and edges
and in polish finish The core of the shutter is to
be filled up with injected fire extingushing
grade.polyurethane foam done in situ along
with embedded wooden pieces for stiffering
and also for tacking hinges and fixtures. The
whole FRP frame and shutter is to be water
proof.weather proof,tennite proof and
resistance to mild acid/ Alkali, Rates are to be
inclusive of S.S. hinges with necessary screws
and brass fixtures and fasening.
Making connection to the ex.M.H.in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be
well repaired as per instructions.
a 1.00 For Pipe 150 mm to 300 mm diameter 1339.29 No.
b 1.00 For Pipe 400 mm to 600 mm diameter 2232.14 No.
Making connection of galvanised Mild steel
distribution branch with galvanised mild steel
56 1.00 main 50mm to 80mm nominal bore by 600.08 No.
providing and fixing tee including cutting and
threading the pipes complete
Providing throating or plaster drip, grooves
and moulding to Wall , R.C.C. chajja and slab.
Providing & Laying cement vatta 10 cm x
cm in size quarter round in c.m. 1:1 (
57b 80.00 cement, 1 coarse sand) laid in one layers 23.45 Rmt
finishing with a floating of neat cement
watering etc complete as dire.
Carring out plinth treat ment to post
construction/ existing structure by spraying
chemical solution for termite control treatment
including labour and material consist ment
withI.S.I specification. Using Chlordene and
Chiorpur files 20EC. As Per 6131_ paret- II
Consentration Weight one percent is
recommended i.e one litre 20EC chemical
emulsion with19 liter give1% concrentration
inclusive of one litre chemical emulsion
appication at the rate of 5 Litre chemical/ Sqm
of surface is recommended as per I.S
Carring out timber treatment to all wood work
including drilling holes and spraying oil based
chemical solution on surface of timber work for
termite control including labour and material
etc. complete. Using Chlordene 20EC. As Per
6113_part III Consentration Weight
percent is recommended one litre chemical
emulsion dillute with 9 liter of kerosene precent
concentration. Total dillute concrentration will
be10litre inclusive of the litre chemical
emulsion application 0.75/Litre chemical per
one Sqmt printed two coat wood surface.
Paver Block Providing and laying shot blasted
Non - interlocking, Paver blocks of specified
thickness, size, grade of concrete and colour
machine made and blasting by automatic shot
blasting machine and high density of as per
approved sample of approved make for
footpath, parking areas, service lanes,cross
over and other areas as mentioned in the
drawing. Including providing and laying 50 mm
thick averave bedding layer of coarse sand
below paver block as per required grading and
specification. Laid paver block shall be
mechanically compacted. The work of the
paving blocks shall be executed in line and
60 300.00 level by skilled mason of flooring work only. 758.93 Sq.mt.
Small size of paver block with same
specification shall be used at residue or at
end. It should be laid in such a way that the no
cutting of the paver block to be necessary. If
cutting of paver block shall be required , than
cut by machine only and laying to be done by
skilled flooring mason. The finished surface of
the paver block shall have coarse sand
Texture Finish. Pave blocks shall be
compacted and shall be re-laid if necessary.
Actual laid area shall be measured and paid
without any wastage. (A) 80 mm thick M-35
grade Grey Paver block of size 200mm x
200mm. As per approved rate
SProviding and fixing pre-cast concrete kerb
stone of gray cement based concrete block
30cm length,30cm height and 15cm thick of
61 350.00 M250 grade concret as per approved design 358.06 R.mt.
and including excavation for fixing in proper
line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
Providing and fixing double action hydraulic
floor spring of approved brand and
manufacture conforming to IS : 6315, having
brand logo embossed on the body / plate with
double spring mechanism and door weight
upto 125 kg, for doors, including cost of cutting
62a 4.00 floors, embedding in floors as required and 4558.89 No.
making good the same matching to the
existing floor finishing and cover plates with
brass pivot and single piece M.S. sheet outer
box with slide plate etc. complete as per the
direction of Engineer-in-charge. With stainless
steel cover plate minimum 1.25 mm thickness
Providing and fixing aluminium extruded
section body tubular type universal hydraulic
door closer (having brand logo with ISi, IS :
3564, embossed on the body, door weight
upto 36 kg to 80 kg and door width from
mm to 1200 mm), with double speed
adjustment with necessary accessories and
screws etc. complete.
Designing, fabricating, testing, installing and
fixing in position Curtain Wall with Aluminium
Composite Panel Cladding, with open grooves
for linear as well as curvilinear portions of the
building , for all heights and all levels etc.
(a) Structural analysis & design and
preparation of shop drawings for pressure
equalisation or rain screen principle as
required, proper drainage of water to make it
watertight including checking of all the
structural and functional design.
(b) Providing, fabricating and supplying and
fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of
approved shades made out of 4mm thick
aluminium composite panel material consisting
of 3mm thick FR grade mineral core
sandwiched between two Aluminium sheets
(each 0.5mm thick). The aluminium composite
panel cladding sheet shall be coil coated, with
Kynar 500 based PVDF / Lumiflon based
fluoropolymer resin coating of approved colour
andshade on face # 1 and polymer (Service)
coating on face # 2 as specified using
stainless steel screws, nuts, bolts, washers,
cleats, weather silicone sealant, backer rods
(c) The fastening brackets of Aluminium alloy
6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the
wind load movement, fasteners, SS 316 Pins
and anchor bolts of approved make in SS
Nylon separators to prevent bi-metallic
contacts all complete required to perform as
per specification and drawing The item
includes cost of all material & labour
component, the cost of all mock ups at site,
cost of all samples of the individual
components for testing in an approved
laboratory, field tests on the assembled
working curtain wall with aluminium composite
panel cladding, cleaning and protection of the
curtain wall with aluminium composite panel
cladding till the handing over of the building for
occupation. Base frame work cost for ACP
cladding is included in this item rate. The
Contractor shall provide curtain wall with
aluminium composite panel cladding, having
all the performance characteristics all
complete , as per the Architectural drawings,
as per item description, as specified, as per
the approved shop drawings and as directed
by the Engineer-in-Charge. However, for the
purpose of payment, only the actual area on
the external face of the curtain wall with
Aluminum Composite Panel Cladding
(including width of groove) shall be measured
in sqm. up to two decimal places.
Providing and Fixing Box type metal letters
forming composite box made from 1mm thick
stainless steel plate of grade 304 having brush
finish of following font size to be fixed at Main
Gate in english and or Gujrati and including
fixing charges. etc. complete as per direction
of Engg. incharge. for Payment Purpose
Height of Letter will be measured.
a 960.00 Upto 300 mm Height 93.85 R. Inch
Providing and Fixing MURAL made out of
2mm thick s.s. plate grade 304, including
making necessary design as per Architect
dwg. Through laser cutting including
connection to the R.C.C./Masonary with
necessary frame,anchor fastnuts,M.S.Plate
etc. complete as per direction of Engg.
Providing and Fixing Sinage - internal and
external signage boards with Vinyle Text on
ACP sheet / 2 mm th. S.S. Plate etc. complete
as per direction of Engg. incharge.
Providing and fixing retro Reflective Hi
Intensity Micro Prismatic Grade Board using
2mm Aluminum / 4mm ACP, angle iron 75 x
75 x 6mm. Descaling and degreasing the
board as per requirement using epoxy
reflactive process by screen painting as
directed etc. complete including transporting
and fixing in C.C. 1:2:4 with necessary
excavation curing etc. complete as per I.R.C.
67-2012 design. A warranty for 7 years for the
Retro reflective sheeting from original
manufacturer & a certified copy of 3 year
outdoor exposure test report from third party
test lab for the product offered shall be
submitted by contractor. (B)Class B Type-
4(MDR/ODR) retro reflective sheeting
Road marking with hot applied thermoplastic
paints with reflectorising glass beads on
bitumin surface providing and laying a hot
applied thermoplastic compound 2.5 mm thick
including reflectorising glass beads @ 250gms
per sqm area, thickness of 2.5mm is excluding
of surface applied glass beds as per IRC:35-
2015. The finished surface to be level, uniform
and free from streaks and holes. zebra patta
/bump patta lane/center line/ edge line/cut
patta. The white color marking should provide
liminance coefficinet on cemend road shalll be
min 130 mcd/m2/lux and Asphalt road shall be
min 100 mcd/m2/lux during the service life
during the day time. The marking should meet
the performance criteria for night time
reflectivity, wet reflectivity and skid resistance
as mentioned in the section-15 of IRC
Warranty for the Retro reflectivity should be
CAT EYE/Pavement Marker(MNC two nail)
made out of acrylic StreneAcrylonitrile or hi-
impact poly Steren fitted with moulded of
metheacrylate(MNC)reflector cube corner
reflector design,filled with tightly adhering
pooting compound as per ASTMD-788 size
65e 10.00 11.5x7x1.60 cms or 10x10x1.75 cms provided 160.71 Nos.
with bituminous adhesive in sufficient quantity
with each unit fixing with two shrank .Reflector
on both side.Co efficient of lumination as per
specification and compressive strenth 13 tones
at 23 degree centigrade etc.B) Double side
Providing and fixing eco-friendly light weight
calcium silicate false ceiling tiles having T
egular edge & 15mm Thick Densified edges on
the Tile Periphery for Extra Strength The Light
66a 560.00 weight calcium silicate ceiling tiles shall have, 1632.63 Sq.mt.
light reflection 85% non-combustible as per
B.S.476 part IV, 100% humidity resistance and
also having thermal conductivity 0.043° w/m
KC. for the best thermal Insulation.
The Light weight calcium Silicate tile shall be
of approved texture Fine fissured/ Spintone/
Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent
of size 595X595 mm to be laid on true
horizontal level suspended inter locking metal
grid of hot dipped galvanized steel sections
(galvanizing @ 120 grams per sqm including
bothside) consisting of main ‘T’ runner suitably
spaced at joints to get required length and size
of 24X38 mm made from 0.30 mm thick
(minimum) sheet, 1200 mm centre to centre,
and cross ‘T’ of size 24X28 mm made out of
0.33 mm (Minimum) sheet spaced 1200 mm
along spaced between main ‘T’ at 600 mm
centre to centre to form a grid of 1200X600mm
and secondary cross ’T’ of length 600mm and
size 24x28mm made of 0.30 mm thick
(Minimum) sheet to be interlocked at middle of
the 1200X600mm panel to form grid of size
600X600mm resting on periphery walls /
partitions on a perimeter wall angle pre-coated
steel of size (24X24X3000mm made of
0.40mm thick (minimum)
sheet with the help of rawl plugs at 450mm
centre to centre with 25mm long dry wall
screws @ 230mm interval and laying 15mm
thick Densified edges light weight calcium
silicate ceiling tiles of approved texture (Fine
Fissured/ Cosmos/Spintone) in the grid
including, cutting /making opening for services
like diffusers, grills, light fittings, fixtures,
smoke detectors etc., wherever required, Main
‘T’ runners to be suspended from ceiling using
G.I. slotted cleats of size 25X35X1.6mm fixed
to ceiling with 12.5mm dia and 50mm long
dash fasteners, 4mm G.I. adjustable rods with
galvanized steel level clips of size
85X30X0.8mm, spaced at 1200mm centre to
centre long main ‘T’ bottom exposed with
24mm of all T-sections shall be pre-painted
with polyester baked paint, for all heights,
, as per specifications, drawings and as
directed by engineer-incharge.Note:- Only
calcium silicate false ceiling area will be
measured from wall to wall. No deduction shall
be made for exposed frames/ opening (cut
outs) having area less than 0.30 sqm. The
calcium silicate ceiling tiles shall have NRC.
Value of 0.50 (Minimum) for Fine fissured/
Spintone/ Cosmos and 0.75 NRC for Globe,
light reflection 85% noncombustible as per
B.S. 476 part IV, 100% humidity resistance
and also having thermal conductivity. 0.043°
w/m KC.for the best thermal Insulation
Providing and fixing single layer water proof
gypusm board 12.5 mm thick of the make New
good Group Co.Ltd. or equivalent & New good
Group Co.Ltd. company sections using water
proof board of size 1220 mm x 1830 mm x
mm suspended by G.I suspender of size
mm x 3 mm with intermediate channel of size
18mm x40mm x0.80mm at 1220 mm center to
66b 360.00 center ceiling section of size 40mmx 35mmx 600.94 Sq.mt.
0.55mm at 457 mm center to center and
perimetre chanel A of size 20mm x 27mm x
30mm x 0.50mm at edges & drops including
paper taps and sofit cleat, anchor fastener,
scoch bolt connecting cleat joining compound
top coat on ceiling including making necessary
opening for light fitting, diffuser etc. complete
as per detail drawing as directed.
Providing and Fixing 6 mm thick Lexan
Polycarbonate multi wall roofing sheet fixed
67 10.00 with hilti screw and rubber silicon sealer and 1427.62 sq.mt.
alluminium strip of size 50 x 3 mm etc
complete as directed by Engineer in charge
Manufacturing,testing ,supplying
loading,,transporting to work site,loading
unloading lowering in trenches,laying and
jointing RCC NP3 class pipes in C:M 1:1
including all jointing materials such as
cement,sand,hemp bitumen as directed testing
the pipe line to a head of 1.5 mt and hydraulic
test as directed etc comp.
a 130.00 300 mm Diameter 616.07 Rmt
b 10.00 450 mm Diameter 806.25 Rmt
Constructing Bombay Pattern Type Catch Pit
of size 0.60 x 0.60 depth up to 1 mt including
excavation, B.B.C.C. (1:5:10), 23 cms thick
brick maso. wall in the prop. of CM (1:6) with
40 mm thick IPS flooring in the prop M15 at
bottom and 15 mm thick cement plaster inside
the catch pit in the proportion of CM (1:3) with
out jali etc. comp. as directed.
CatchPit Jali Fixing P/F FRC catch pit jali with
70 15.00 frame 600mm x 600mm clear opening etc. 1383.93 No
comp.. As directed by engineer in charge.
PERCOLATION WELL
Drilling of pilot bore hole in Alluvial Strata by
direct Rotary Rig of 250 mm.
72 120.00 Reaming 400 mm 212.50 Rmt
73 1.00 Electro Logging charges with carting 16071.43 Job
Providing and Installing 200 mm dia IS:12818
upvc Casing Pipe "CM" class plain Pipe
Providing and Installing 200 mm dia IS:12818
upvc End Cap, with Air Vent cowl
200 mm dia Regular with 1.5 mm sloted size
cage type trapezoidal shape wire wound little
carbon galvanized screen confirming to
77 10.00 Supply of Pea sized Gravel 2029.46 Cmt
78 1.00 Air Vent of 50 mm Bend 401.79 Unit
Lowering and Removing of Dropline up to
80 1.00 Air Compressor 60 CFM/150 PSI 22205.36 Ls
Estimate For Civil Work With Percolation
I. No. Qty Items Rate Per
Electrical Work Estimate
1.0 INTERNAL WIRING
1.1 Point wiring for Light / Bell with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/HRFR PVC insulated
multi strand copper wires up to 10 mtr length , in
below type of pipe erected with 6A Modular type
switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate
modules erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed.
120 (f) with medium class Rigid PVC pipe and 505.05 Pt
accessories erected concealed in wall/ceiling
1.2 Point wiring for FAN with 2-1.5 sq.mm & earth wire
of 1.5 sq.mm (Green) both are of .ISI marked
KV Grade ZHFR/HRFR PVC insulated multi strand
copper wires up to 10 mtr length, in below type of
pipe erected with 6A Modular type switch and hum
free EME four or more step type electronic fan
regulator with separately mounted and accessories
with earth continuity of following type erected on
PVC / Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as per
pipe erected. with necessary ceiling rose /
H.D.Connector as directed.
20 (f) with medium class Rigid PVC pipe and 701.40 Pt
accessories erected concealed in wall/ceiling
1.3 Point wiring for secondary light point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both are
of ISI marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires, in below type of
pipe to be erected complete with earth continuity
and necessary connection with primary light with
accessories erected on Metal / PVC / wooden box
covered covered with appropriate front plate
modules erected on / in wall / ceiling for open /
concealed wiring. with necessary Lamp holder /
ceiling rose / H.D.Connector as directed.as per pipe
erected with following type of accessories.
Note:- Maximum up to 6 mtrs length, excess will
be considered as Mains for Secondary Point.
120 (f) with medium class Rigid PVC pipe and 174.30 Pt
accessories erected concealed in wall/ceiling
1.4 Point wiring for Individual Plug with & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade ZHFR/HRFR PVC insulated multi strand
copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch &
pin Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected with
following type of accessories.
1.4.1 40 [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm 530.25 Pt
Cu. Wire from nearby switchboard/mcb db
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
1.4.2 25 [II] For 16A Plug and 16 amp switch with 2-2.5 774.90 Pt
sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
1.4.3 2 [III] For 16A Plug and 16 amp switch with 2-4 906.15 Pt
sq.mm Cu. Wire with 2.5 sq.mm ( green)
earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
1.5 50 Point wiring for on board Looped Plug with 6A 255 Pt
Modular type switch & 5 pin socket erected on PVC
/ Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories
1.6 Point wiring for Two Way Controlled Light Point
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green)
both are of .ISI marked 1.1 KV grade ZHFR/HRFR
PVC insulated multi strand copper wires erected in
below type of pipe with 6A Modular type switches
and following type of accessories erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or
ceiling rose or H.D.Connector as directed.
3 (f) with medium class Rigid PVC pipe and 627.90 Pt
accessories erected concealed in wall/ceiling
1.7 Providing following type of Modular Type
Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with
textured / metallic/white front plate , modules
erected with necessary connections as per site
situation directed by Engineer In charge.
1.7.1 5 (1)One No. SP 6 Amp. 150 E.a.
1.7.2 5 (2) One No 5 pin plug 150 E.a.
1.7.3 40 (7) Blank Plate Single 25 E.a.
1.7.4 1 (8) Computer RJ-45 socket 159 E.a.
1.7.5 15 (9) 16 Amp. SP one way switch 179 E.a.
1.7.6 15 (10) 6/16Amp. Universal socket 198 E.a.
1.7.7 2 (13) 6A/10A/16A/20A/25A/32A Single pole Modular 307 E.a.
Modular MCB Switch
1.8 Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in
approved manner as directed
1.9 Providing & erecting PVC Corrugated Flexible
Conduit with required nos. of coupling, PVC
bushes, Check-nuts etc. complete of following
1.10 providing and erecting Mains with ISI marked
electrolyte stranded copper conductor, Non PVC
Zero Halogen free fire retardant insulated copper
conductor, insulated wire (HRFR) conforms to IS-
694, erected in existing pipe with 1.5sq. mm copper
conductor of same specifications for earth continuity
of following size.
In Existing medium class Rigid PVC pipe and
1.10.1 750 (a) 2 wire 1.5 sq. mm 51 Mtr
1.10.2 1190 (b) 2 wire 2.5 sq. mm 71 Mtr
1.10.3 85 (a) 2 wire 4 sq. mm 101 Mtr
1.10.4 410 (b) 2 wire 6 sq. mm 139 Mtr
1.11 providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of
(A) with medium class Rigid PVC pipe and
1.11.1 60 (h) 4 wire 6 sq. mm 258 Mtr
1.11.2 10 (i) 4 wire 10 sq. mm 421 Mtr
(use earth wire of 4 sq.mm )
1.12 providing and erecting Mains with ISI marked,
1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing
pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters
& control wiring) with required size of copper lugs,
nuts and bolts if required.
1.12.1 20 (e) One wire 6.00 sq. mm 56 Mtr
1.12.2 20 (f) One wire 10.00 sq. mm 91 Mtr
1.12.3 10 (g) One wire 16.00 sq. mm 141 Mtr
1.12.4 5 (h) One wire 25.00 sq. mm 234 Mtr
1.12.5 10 (i) One wire 35.00 sq. mm 298 Mtr
1.12.6 40 (j) One wire 50.00 sq. mm 466 Mtr
1.12.7 20 (k) One wire 70.00 sq. mm 663 mtr
1.12.8 20 (l) One wire 95.00 sq. mm 910 mtr
1.13 Supplying and erecting Flexible PVC insulated
multi strand multi core 1.1 kv grade ISI marked
copper wires of following size to be erected as
1.13.1 120 e) 1.50 Sq.mm 3 core round PVC sheathed 46 Mtr
1.13.2 40 h) 2.50 Sq.mm 3 core round PVC sheathed 77 Mtr
1.13.3 20 k) 4.00Sq.mm 4 core round PVC sheathed 175 Mtr
1.14 Supplying & erecting M.S. Box having 16 Gauge
painted with red oxide or Heavy duty PVC box
erected flushed on wall or concealed in wall with
necessary plastering & finishing as directed of
following size.
1.15 Supplying and laying UPVC cable trunking system
comprising unplasticised polyvinyl, chloride rigid
material with ignition free and flame proof
confirming BS with necessary end caps Internal and
external bend, flat bends, coupler, tee etc..All
necessary accessories and measuring of following
1.15.1 5 (2) 100 mm x 50 mm trunking 424 Mtr
1.15.2 5 (4)100 mm x 50 mm trunking with TWIN 1309 Mtr
compartment With clip in divider
1.16 Supply & installation of surface mounted U PVC
snap-on adaptable trunking raceways, fabricated
out of U-PVC to Off-White or approved shade as
per IS 733 of thickness 2.0mm for the base and
sides with all accessories like removable covers,
joints ,height spacer,angles complete with
necessary bends, suitable sized junction boxes and
tees etc, Complete.
5 (a)Size: 50x80mm PVC Raceways for Power & 1052 Mtr
Data with 2 compartments above specifications.
1.17 Supply & installation of modular type accessories
for U PVC snap-on adaptable trunking/Pop up Box
with required items erected with necessary
connection. As desired by Engineer In charge
1.17.1 1 i) 6 A SP 1 Way Switch 204 No
1.17.2 1 ii) 16A SP 1 Way Switch 351 No
1.17.3 1 iv) 6A universal socket shuttered 347 No
1.17.4 1 iv) 6/16 A universal socket shuttered 458 No
SUB - TOTAL OF INTERNAL WIRING
2.0 Switchgears , Panels , MCBDBs & MCBs
2.1 Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 50 KA and above at 415 V having
Normal current rating 400A. with variable Thermal
& magnetic release suitable to work on A.C.supply
50 c/s. With all internal connections, spreader
tinned copper & complete erected in existing
G.M.S. housing. Overload release Range: 215 -
1 ICS=100% of ICU only 27476.9 No
2.2 providing and erecting Approved make Earth fault
Relay suitable to mount with inter connection
suitable to following size of moulded case circuit
breaker having CT ratio & MCCB rating as
following along with shunt trip 220V AC. with all
internal connections & complete erected in existing
2.3 Design, fabrication, assembling, supply, installation,
testing and commissioning of cubicle type, wall /
Floor mounted LT panel suitable for 415 V
phase, 4 wire 50 Hz AC supply system fabricated in
compartmentised design from CRCA sheet steel of
2 mm thick for frame work ,Doors and partitions IP
42 and covers,3 mm thick for gland plates i/c
cleaning and finishing complete 9 tank process in
house facility for powder coating in approved
shade, extendable type FP aluminium alloy busbars
of high condectivity, DMC/SMC busbar supports,
entire panel shall have a common copper earthbar
of size 25mm X 5 mm / 50 x 6 Al at the rear with
Nos. earth studs, solid connection from main busbar
to switchgears with require size of aluminium
busbar & control wiring with 1.5 sqmm FRLS
insulated copper conductor cable, cable alleys,
cable gland plates i/c accessrories as per
specification and providing switchgears, metering
instruments etc. for following panel.G.A.Drawing to
be approved by EIC or consultant. ( Outgoing
connectors must be nut-bolt type. Outgoing mains
for 63Amp MCBs must be of 4 x 16sqmm cu flexible
wires).Incomers Mains for MCBs shall be always
from the busbars.
( a ) Providing cable clamps / supports within
distribution boards cable alley.
( b ) All hinged door shall be earthed through 2.5 sq
mm tinned b raided copper wire.
( c ) Pad locking of MCCB’s handles in “OFF”
( d ) All the C.T.s should be auto short link type.
( e ) All the MCCB's should be with rotary handle.
( f ) All incoming and outgoing air circuit breakers
shall be placed on middle portion of the vertical in
single tier formation.
( g ) Any descripancy found in SLD & Boq , it should
be brought in the notice of the client / consultant,
and the decision will be taken final by Client /
2.3.1 1 MAIN P.D.B. 309280 No
A. Incoming Feeder:-
(i) 1 Nos. of 400 Amps, 415V,50kA, FP MCCB with
Thermal magnetic Based releases having O/C, S/C
protection, extended Rotory handle for operation
along with following
(ii)LED type Indicating Lamp with suitable rating 2A
(iii) Digital type 3 phase KWH Meter with suitable
rating of MCB & 3 Nos. of single core epoxy resin
cast type CTs of 400/5 Amps, 15 VA, CL
ratings -1 Sets.
Suitable size of C.T. for APFC Panel
400 Amps, 415 V, FP Aluminium Busbars with Heat
shrinkable color code insulation sleeves. 1sqmm
( I ) 1 Nos. 160Amp, 25kA FP MCCB with Thermal
magnetic based releses having O/C, S/C , extended
Rotory handle for operation. Indicating Lamp- ON
Digital type 3 phase KWH Meter with suitable rating
of MCB & 3 Nos. of single core epoxy resin cast
type CTs of 125/5 Amps, 15 VA, CL 1.0 ratings -1
Sets. Feeder power supply from the incomer of
400A FPMCCB of the panel.
( II ) 3 Nos. 125Amp, 25kA FP MCCB with Thermal
magnetic based releses having O/C, S/C , extended
Rotory handle for operation. Indicating Lamp- ON
Digital type 3 phase KWH Meter with suitable rating
of MCB & 3 Nos. of single core epoxy resin cast
type CTs of 100/5 Amps, 15 VA, CL 1.0 ratings -1
( III ) 1 Nos. 80Amp, 25kA TP MCCB with Thermal
magnetic based releses having O/C, S/C , extended
Rotory handle for operation
(IV )40Amp FP MCB, 10kA - 4 Nos.
( V )40Amp DPMCB , 10kA "C" Curve - 13 Nos.
( VI )25Amp DPMCB , 10kA "C" Curve - 1 Nos.
2.3.2 1 HVAC- Physiotherapy hall 76835 No
A. Incoming Feeder:-
(i) 1 Nos. of 125 Amps, 415V,25kA, FP MCCB with
Thermal magnetic Based releases having O/C, S/C
protection, extended Rotory handle for operation
along with following
(ii)LED type Indicating Lamp with suitable rating 2A
125 Amps, 415 V, FP Aluminium Busbars with Heat
shrinkable color code insulation sleeves. 1sqmm
16Amp FP MCB, 10kA - 10 Nos.
2.3.3 1 HVAC- YOGA & Meditation Hall 80782 No
A. Incoming Feeder:-
(i) 1 Nos. of 160 Amps, 415V,25kA, FP MCCB with
Thermal magnetic Based releases having O/C, S/C
protection, extended Rotory handle for operation
along with following
(ii)LED type Indicating Lamp with suitable rating 2A
160 Amps, 415 V, FP Aluminium Busbars with Heat
shrinkable color code insulation sleeves. 1sqmm
16Amp FP MCB, 10kA - 10 Nos.
2.3.4 1 Design, Supplying, installing, testing of factory
fabricated ready made Three phase APFC Panel
Cubical Panel fabrication should be type tested as
per IEC 61921, 61439:1&2 Capacitor Duty
Contactor for switching as per following Steps
Incomer Switch of MCCB type Icu=Ics=50KA at
400/440 Volts, with OC, SC, internal earth fault
protection Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with OC, SC,
internal earth fault protection,Copper tinned
insulated Busbar,Cubical panel should be indoor
type with IP 43 and IK 10,Metalized polypropylene
film tye3-phase 550Volt Capacitor,De tuning
Reactor for each capacitor,Panel having Short
Circuit and Overload protection,Each step Capacitor
having suitable MCB with Sc, OL, internal earth
fault relay,Each stage having Stage Contactor
(Capacitor load rating),PF regulator master
controller having suitable steps with LCD display,
Rs 485 Communication port, Indication LED Lamps
for main incomer and ON-OFF for each capacitor
bank,MS Chanel for Floor mounting, Cable entry as
per site situation,Cooling fans for panel
1 (A)50KVAR 141527 No
2.3.5 Supplying & erecting approved make IP 55 grade
Company fabricated Timer Panel of following
capacity for switch On-Off street lights on time
scheduling basis made from 16G CRCA sheet duly
epoxy power painted inside and outside with hinged
doors and locking arrangement consisting of
suitable size of 4 Pole MCB and 4 pole contactor
(cat-III)with analog time switch, auto manual switch
of same make and suitable input and output
Bakelite terminals and with door earthing approved
by Engineer in charge.
MCBDBs and MCBs
2.4 140 providing and erecting Miniature circuit breaker 111 E.a.
single pole 6A to 25A suitable to operate on 240 V
A.C. system and having breaking capacity 10 KA to
be erected in existing box. confirming to IS
8828/1996 with ISI Mark
2.5 Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity
2.6 Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in existing
box having following capacity
2.7 4 Sheets steel powder coated enclosure suitable 175 E.a.
for incorporating One/Two nos. MCB.
2.8 Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted
fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of
MCBs.(The DBs should be used of same company
of MCB to be used) suitable for
(A) single phase incoming and horizontal single
(b) sheet steel double door (IP-43)
2.8.1 4 (i)4 way ( concealed manner ) 747.60 E.a.
2.8.3 2 (iii)8 way ( concealed manner ) 1369.20 E.a.
2.8.5 12 (iv)12 way ( concealed manner ) 1773.60 E.a.
2.9 (B) three phase incoming and single phase
horizontal type outgoing Per phase isolation
(b) sheet steel double door
2.9.1 2 (i)4 way ( concealed manner ) 2779.20 E.a.
2.9.3 1 (ii)6 way ( concealed manner ) 3462 E.a.
2.10 providing and erecting Approved make ELCBs /
RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on
single phase 240 V,50Hz. having characteristic of
quick action & tripping with all advance feature & do
not incorporate any electronic component. for
following Max. rating erected as directed
2.10.3 1 (iii) 63 Amps. DP 2628 E.a.
2.11 15 Providing and erecting metallic vitrified danger 69 E.a.
notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE
installation to be erected as per IS-2551.
2.12 15 Providing & erecting Medium Voltage Danger 26 E.a.
Notice Board sticker as per language suggested
by engineer incharge of standard size as per IS-
SUB - TOTAL OF Switchgears , Panel and
Follow IS code :3043 is the guideline for the
3.1 180 Providing and erecting required size HOT deep 77 KG
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc.
using proper clamp.
3.2 20 Providing and erecting required size Copper strip 787 KG
for earthing of H.T. OCB / ACB/ Transformer, LT
panel board, Motors etc. using copper clamp.
3.3 15 Providing and erecting Annealed bare Copper 787 KG
wire 8 to 16 SWG.
3.4 45 Providing and erecting HOT deep Galvanised iron 77 KG
strip wire 8 to 16 SWG.
3.5 Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia of
25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant
ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and
heavy duty cover.(approved make OEM has to
submit test certificate) & having back filling
compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 W/ meter testing as
per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be
capable to retain moisture for long time Necessary
test report must be submitted.
(a) For Electrical Installation up to 440V in normal
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
3.5.2 1 (c) For Electrical Installation covering Transformer 8551 E.a.
Neutrals, Lightning arrester Earthing, A.C.Plant &
Sensitive Computer System(like Automation,
SCADA) i.e independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
3.6 Supplying & erecting in earthpit of minimum bore
dia. 225mm size approved make Safe Earthing
Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 80 mm having
80-200 Micron galvanising, Inner pipe dia of 40 mm
having 200-250 Micron galvanising, connection
terminal dia of 14 mm with constant ohmic value
surrounded by highly conductive compound with
high charge dissipation suitable for following type of
applications with chamber and heavy duty cover
(A)(approved make OEM has to submit test
certificate including value of earth resistance of
installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing
resistane mentioned in test Certificate) & having
back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as
per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be
capable to retain moisture for long time Necessary
test report must be submitted by Agency.
4 [C] For Electrical Installation covering Transformer 10489 E.a.
Neutrals, Lightning arrester Earthing, A.C.Plant
& Sensitive Computer System(like Automation,
SCADA)i.e. independent Earthing located in
other than normal soil i.e. Soft Rock, Marshy
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
SUB - TOTAL OF Earthing
4.0 CABLES, Cable Termination and cable
4.1 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables
4.1.1 40 (A-1) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) 218 Mtr
4.1.2 75 (B) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core) 282 Mtr
4.1.3 35 (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) 375 Mtr
4.1.4 20 (E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) 486 Mtr
4.1.5 50 (F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) 535 Mtr
4.2 Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables
4.2.1 25 (a) 4 core 4 Sq. mm 116 Mtr
4.2.2 370 (b) 4 core 6 Sq. mm 125 Mtr
4.2.3 90 (c) 4 core 10 Sq. mm 139 Mtr
4.3 Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables
4.3.1 60 (d) 4 core 16 Sq. mm 152 Mtr
4.3.2 15 (e) 4 core 25 Sq. mm 189 Mtr
4.4 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be
erected as directed of following size.
4.4.1 15 (G) 3 core 6 Sq. mm 290 Mtr
4.4.2 10 (H) 3 core 10 Sq. mm 439 Mtr
4.5 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe at
road crossing or floor of following size of cables.
4.5.1 30 (A) 4 core 2.5 Sq. mm 269 Mtr
4.5.2 560 (B) 4 core 4 Sq. mm 361 Mtr
4.5.3 50 (C) 4 core 6 Sq. mm 505 Mtr
4.6 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road crossing
or floor of following size of cables.
20 (C) 4 core 10 Sq. mm 670 Mtr
4.7 280 Making trench in soft soil of suitable width of 90 cm 55 Mtr
deep for laying cable or locating the fault all over
the run and back filling the same and making the
surface as normal ground.
4.8 30 Covering of cable with second class bricks or 139 Mtr
cement tiles laid cover the cable crosswise & also
on both sides with covering of 7. 5 Cm. layer of
sand above & below cable (16 bricks per meter)
4.9 15 ( A )Making trench in Hard Murrum / Tar Road of 74 Mtr
suitable width of 90 cm or required depth for laying
any size of cable or locating the fault all over the
run and back filling the same and making the
surface as normal ground.
4.10 5 (B) If additional machinery like hammer driller or 354 Mtr
4.11 Drilling the road without breaking the road
surface (Asphalt) for laying of cable for feeding
power supply by making up to following size of
holes at both ends complete.
4.11.1 5 (A) Up to 100 mm bore dia 488 Mtr
4.11.2 5 (B) Up to 150 mm bore dia 610 Mtr
4.12 Supplying following size of Light duty “A” Class
G.I . Pipe & erecting as directed by Engineer-in-
20 (A) 25 mm dia 171 Mtr
4.13 Providing & laying. R.C.C. Hume pipe for cable to
be laid 90 cm. below ground across the road
crossing or on floor with necessary material in an
approved manner and making the ground as per
4.14 Providing & laying approved make Double walled
corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable
4.14.1 90 (A)50 mm outer dia 62 Mtr
4.14.2 380 (B)63mm outer dia 73 Mtr
4.14.3 50 (C))90 mm outer dia 95 Mtr
4.14.4 40 (D)120 mm outer dia. 136 Mtr
4.15 Providing & laying approved make ISI marked
Rigid PVC pipe having 6Kg / cm2 (Class-3) to be
erected at road crossing on or floor as directed for
laying of cable. The pipes as following size of dia &
weight per 6 mtr.
4.15.1 15 (D) 75 mm inner Dia. (5.5 Kg/6RMT) 124 Mtr
4.15.2 10 (F) 110 mm inner Dia. (11.63 Kg/6 RMT) 234 Mtr
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables.
4.16.2 45 (b) 2 to 4 core 6 Sq. mm 38 E.a.
4.16.3 16 (c) 2 to 4 core 10 Sq. mm 38 E.a.
4.16.4 4 (d) 2 to 4 core 16 Sq. mm 47 E.a.
4.16.5 2 (e) 2 to 4 core 25 Sq. mm 51 E.a.
4.17 Providing and, fixing heavy duty flange type brass
double compression type cable gland with
rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
4.18 Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
4.19 Solder less crimping type Copper lugs conforming
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner.
4.20 Providing and fixing approved make Perforated C
type cable tray. Made from sheet steel. The cable
tray should be single or double bended as per
required and as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS
2629/4759. with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like nut -
bolt and washers etc. erection with necessary
support( included) as per Specification and as per
instruction of engineer in charge..
SUB - TOTAL OF Cables,Cable
Terminations & Cable Trenches
5.0 Light Fixtures & Fans
Supply , Installation, testing and commissioning of
pre-wired, LED fitting/post top luminaries etc of all
types, complete with all accessories and tube etc.
directly on ceiling/ wall, including connection with
1.5 sq. mm FRLS PVC insulated, flexible, copper
conductor, single core cable with flexible conduits
and coupler and earthing etc. as required. Note:-
The LED Light fixtures should comply all
international standards third party ( LM 79 for
complete fixture, LM 80 for individual LED ).
The Manufacturer / Channel Partner of the
Manufacturer has to submit 4- Years
unconditional free Replacement Guarantee for
complete fixture.
5.1 Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt assembled on
single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor
more than 0.95, THD < 15%,CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver
efficiency > 85 %( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
5.1.1 ( A ) Tube Light with integral / non integral
5.1.1a 2 (iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 2/ 293 No
5.1.1b 10 (v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 530 No
5.1.2 (B) LED Panel Light with provision for Plane front
frame with translucent cover fixed to housing
5.1.2a 4 (i)up to 8 Watts,4" x 4", Surge-2 KV 271 No
5.1.2b 60 (iii) 12-15 watts, 6" x 6", Surge-2 KV 462 No
5.1.2c 50 (iv) 18 to 20 watts, 8" x 8", Surge- 2 KV 607 No
5.1.2d 4 (vi) 36 watts, 24" x 24", Surge- 2KV 1777 No
5.1.3 (G) Spot Light 425 Lumens, Surge-2KV
5.1.3a 10 (a) 3 to 7 Watts 805 No
5.1.3b 10 (b) 8 to 11 Watts 1354 No
5.1.4 5 (H) Mirror Light 9 Watts, wall mounted minimum 1 309 No
5.1.5 (I) Adjustable spot light with COB led having
aluminium reflector of following wattage
5.1.5a 40 (ii) 12 Watts 957 No
5.1.5b 6 (iii) 15 Watts 1087 No
Providing & erecting Approved make Power
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C.
50 Hz 1200 mm sweep complete having 3blades
with aluminium blades with , canopy & 30 cm. down
rod erected with earthing.(Make shall be approved
by Engineer in charge))
5.3 1 Providing & erecting Approved make Ceiling Fan 1721 No
with double ball bearing ISI mark with condenser
A.C.230V 50c/s. 1400 mm. sweep complete,
canopy erected on existing hook or clamp with
earthing [ Make shall be approved by Engineer in
5.4 1 Providing & erecting Approved make Ceiling Fan 1963 No
with double ball bearing with Condenser 230 volt
A.C.50 Hz. 900 mm sweep complete having
Aluminium blades, canopy erected complete. [
Make shall be approved by Engineer in Charge]
5.5 1 Supplying and erecting approved make oscillating 2329 No
type medium duty bracket fan with Aluminium
Blades A.C. 23OV. 50cy/s wall mounted with height
adjustment and rotary tilting device complete with
guard, mounting accessories kit, pull cord for speed
and oscillation flexible Core plug top complete
erected with lead wires as directed. 400MM.
5.6 2 Supplying & erecting approved make low noise 1687 No
decorative exhaust fan having size 200mm with
1350 RPM with square frame ABS body with inbuilt
lowers & square frame.
5.7 20 Supplying & erecting fan hook box of 10 mm M.S. 107 No
round bar bounded to the RCC bars up to 50mm
length each side and pierced through a 16 Gauge
M.S. box / Heavy Duty PVC box complete erected
concealed in Ceiling with necessary finishing.
5.8 20 Providing 2.5mm.thick laminated acrylic sheet to 18 No
cover the fan hook or Fan box.
Supplying and erecting 19 / 20 mm. nominal bore
Medium Class M.S. Pipe down rod erected duly
painted for fan complete with proper insulation
without leakage and earthing.
5.10 Supplying & erecting single phase approved
make industrial exhaust fan suitable for medium
duty ring mounted low noise operation suitable for
medium duty having following dia size and
maximum speed in RPM
1 [D] 450 mm dia 900 RPM 3306 No
5.11 1 Providing suitable M.S. louver shutter of the 365 No
5.12 1 Supplying & erecting electro galvanised G.I. wire 628 Sqmtr
micro mesh jali cover of grade 304 required size
with suitable wooden frame duly fitted in wall
outside of exhaust fan for insect protection.
5.13 6 Providing and erecting PVC body surface or 780 No
pendent mounting LED Bulk type 9 watt Lighting
Fitting with electronic driver. And lumen output from
luminaire 720lm , input voltage range 90-300VAC
50Hz cool white(3000 to 6500k), inbuilt driver, -
20degC to +60degC working temperature, AL frame
with Beam Angle 120deg
SUB - TOTAL OF Light Fixtures & Fans
6.0 External lighting
Supply , Installation, testing and commissioning of
pre-wired, LED fitting /post top luminaries etc of all
typesof external lights, complete with all
accessories and tube etc. directly on pole / pole
bracket , including connection with 1.5 / 2.5 sq. mm
FRLS PVC insulated,3 core flexible, copper
conductor, with flexible conduits and coupler and
earthing etc. as required.
6.1 Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency >
85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
6.1.1 (A) Street Light (IP-65), Surge protection -4KV
/5000K integral and 10 kv non integral ,Light must
have 440VAC line supply protection. It should
withstand 48 hours for 440VAC line supply.
18 (f) Above 60 watts to 90 watts ( Required 72w ) 5917 No
6.1.2 (B) Flood Light (IP-65), Surge -4KV/5000K ,Light
must have 440VAC line supply protection. It should
withstand 48 hours for 440VAC line supply
6.1.2.a 8 (c) Above 60 watts to 100 watts 6028 No
6.1.2.b 2 (v) above 120 to 160 watts 8370 No
Supply of approved make frp/grp pole having
followiing specifications :
FRP/GRP pole made by centrifugal moulding
process using thermoset resin polyester/epoxy
resin system having minimum glass content
45.0%.The pole should be in one pieceand tapered
round in shape,having smooth outside surface
finish and should be totally fre from corrosion as
well as non conductive and shock proof. Pole
should be provided with FRP/GRP base bracket
dully fabricated from metal(M.S) and dully claded
with FRP/GRP material to avoid any metal exposer
and painted with PU paint.
Pole should mechanical properties i.e 1. Specfic
gravity (ASTM D 792) 1.3‐1.8 Kg/m3, 2. Glass
Content % by weight (ASTM D 2584) 45.0 ‐55.0%,
3. Water absorption (ASTM D 570) <0.5%,
Tensile Strength(ASTM D 638) 200+/‐50Mpa,
Flexural strength (ASTM D 790) 250+/‐50Mpa,
Compressive Strength (ASTM D 695) 200+/‐
50MPa, 7. Yeild Strength(ASTM D638) 250 +/‐
Pole should be flame retardant as per IS
6746.Resin used shall be UV resistance and
pigmented. Pole should be painted with first coat of
epoxy primer and then two coat of highly weather
resistance polyurethen paint to ensure proper
addhesion of the paint.Minimum thickness shall be
80 to 100 micron.Defelection of the pole shall not
exceed more than 10.0 % of the length of the pole
for the given load.Pole should be generally made as
per the dimensional data,performance criteria and
some interchagebility features of poles as per the
standard ANSI C123.20 latest version of ASTM D
923/01 including cable termination box with
necessory accessories.The size of pole and type
of installation with foundation , Anchor Base &
Internal junction box as per the manufacturer
details and site requirement . The cost of 6 Mtr
& 10 Mtr pole's Flood light mounting ring is
(3) 'B' class (Heavy Duty) frp/grp pole suitable
for base plate mounting
16 [D] Overall Length of 6.0 meter, Average thickness : 16815 E.a.
7mm, Top/Bottom Outside Dia. 76/176mm +/‐
2.Weight of Pole 25.0 Kg approx. (Without base)
Metal Anchor Base dully frp claded (Size : 340 Ø *
12mmthk , Mounting hole PCD 285mm * 6 nos. of
Providing FRP/GRP arm bracket of having 15˚ arm
with 50 mm OD pipe *5 mm thk,1000mm long from
6.3.1 14 (a) Single arm bracket 1882 No
6.3.2 2 (b) Double arm bracket 2390 No
6.4 18 Supplying & erecting sintex make SMC press 472 No
moulded composite FRP. loop-in, loop-out approx.
2mm thick box complete with bakelite connector
strip 4way & hinged doors having locking
arrangements with mounting clamp with nuts, bolts
& washers suitable for erection on wall ( c)150mm x
125mm x 100mm [deep].
6.5 8 Providing cement concrete.for foundation or for 5077 CU Mtr
concrete filling in 1:2:4 ratio with 20 to 25 mm stone
metal duly plastered with necessary curing for pole
muffing or any other purpose.
6.6 2 B' class galvanised iron pipe 32 mm outside dia 45 340 No
cms long duly welded on 20 cms x 20 cms x 3 mm
thick M.S. base plate, erected on wall or corner for
mounting street light luminaire with necessary
hardware materials duly painted.
SUB - TOTAL OF External Lighting
7.1 1 Supplying & erecting approved make Automatic 2332 Job
liquid level controller 6A. with sensor testing as
per instruction of Engineer in charge on site
complete with wiring connection with existing wires
with copper conductor from pump to upper and
7.2 Supplying and erecting Flexible PVC insulated
multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as
90 e) 1.50 Sq.mm 3 core round PVC sheathed 46 Mtr
7.3 Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in
approved manner as directed .
7.4 2 Providing & erecting water cooler having storage 55340 No
capacity 150 Ltr. & cooling capacity 150 Ltr.per
hour @ an ambient temp of 45˚ C. The outlet temp.
of the water should drop by 15˚C within a hour, The
water cooler should be comprising of hermetically
sealed compressor, fan motor, condensing unit,
water tank surrounded by evaporating, coil,
thermostats, relay etc.complete with necessary inlet
& outlet connection. The body of water cooler will
be made from Stainless Steel.
7.5 2 Supplying and erecting water filter cum purifier with 5371 No
ultra violate technology. (Aquaguard / waterdoc
model or equivalent symphony/ crystal/videocon
7.6 Providing & erecting open well horizontal mono
block pump set with cast iron body, complete for
three phase submersible motor having
7.6.1 1 [D] For 5 HP 3 phase open well horizontal mono 18561 No
block pump set suitable for 1350 LPM to 310 LPM
@ 10 to 42 Mtr head suitable for 50/65 mm dia
7.6.2 2 [C] For 3 HP 3 phase open well horizontal mono 15552 No
block pump set suitable for 85 LPM to 270 LPM @
11 mtr to 33 mtr head suitable for 50/65 mm dia
7.7 Supplying & erecting approved make motor
control cubical panel (Direct - on - line) made
from 16 G. CRCA sheet duly epoxy powder painted
inside and outside with hinged doors and locking,
arrangement consisting of suitable size of ON- OFF
isolator (AC - 3/23duty) main fuses, single phasing
preventer, indicating lamps for R- Y - B phases,
overload relay, Automatic water level controller,
Ammeter, Voltmeter each with two way selector
switch incoming, wires duly socket crimped, main
contactor & overload relay, start - stop push
buttons, to be erected on angle iron frame grouted
on wall as directed. The isolator, overload relay &
contactors will be of L & T, Siemens or BCH make
2 (a) DOL up to 5.0 H.P. 7646 No
7.8 Supplying & erecting approved make 3 phase motor
control cubical panel ( Star - Delta) made from16
G. CRCA sheet duly painted with epoxy powder
painted inside and outside with hinged doors and
locking arrangement, consisting of suitable size of
ON- OFF isolator (AC - 3/23 duty) main fuses,
single phasing preventer cum water level. Guard
(Complete unit), Toggle switch to by pass Single
phase preventer cum WLG, indicating lamps for R-
Y- B phases, over load relay, Automatic water level
controller, Ammeter & Voltmeter each with two way
selector switch incoming wires duly socket Crimped,
Panel to be erected on angle iron frame grouted
on wall as directed. Star Delta & main contactor,
overload relay, thermal / Electronic Star delta cutoff
timer, start - stop push buttons. The isolator
overload relay & contactors of L& T, Siemens or
Cuttler Hamer make only. Panel to be erected on
angle iron frame ground on wall.
2 (A) S/D up to 7.5 H.P. for sewerage pump in 12865 No
7.9 1 Charges for doing liasioning work for obtaining the 25423.73 No
necessary clearances from the Electrical inspector /
competent Authorities for the total Electrical
installation,co-ordinating with various agencies and
High rise building permission. All necessary
drawings, calculations, test certificates, etc. as
required by these authorities shall be prepared and
furnished by the EPC Vendor. Any
modification/rectification as required by these
authorities shall be carried out by theEPC Vendor at
free of cost. The fees required to be paid to these
authorities for inspection shall be borne by Owner
on production of documentary evidences.
7.10 online Un-interruptible Power Supply
Supplying and erecting approved make online Un-
interruptible Power Supply system comprising flat
cum-boost charger with IGBT base rectifier &
Inverter & sealed maintenance free SMF batteries.
The charger having operating capacity for input
160-270V AC & inverter having output 230V,50 Hz
Ac with 0.8 load power factor with battery,
over/under voltage output with over load & short
circuit protection equipment. The system housed in
CRC sheet duly powder coated paint with following
power backup.with MS painted batteries stand, 10%
Overload capacity for momentary load.
1 (C) 3 KVA with 1Hr Backup 82120 No
SUB - TOTAL OF MISC. Work
PASSENGERS ELEVATOR
Supply ,installing , commissioning and testing of
M.R.L. Passengers Elevator 8 to 10 passengers
as per R & B S.O.R ( Category - Premium ) having
following specifications:- Ground+ 1 upper
Supplying, Erecting, Testing & Commissioning the
passenger lift having following main features:
[1] GEAR LESS LIFT DRIVE comprising of High
Starting torque Lift 3 phase 440 V A. C. Permanent
Magnet Synchronous motor of proper rating with
high efficiency shall be used.
[2] Micro processor based / PLC, ACVVVF, vector
control drive with encoder feedback closed loop
system shall be used for lift car and door operation
which shall be full collective selective operation hall
call demand response, UP/DOWN hall stops, Main,
Up/ Down Contactor with overload and phase
reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate
size and to sustain the impact load cabin +
passenger with safety factor of fire for steel and
side panels of Stainless steel of sheet of grade
duty. Car ceiling will be S.S. finishes with aesthetic
appearance with LED ceiling lights. Car flooring
shall be of anti skid PVC with choice of colour of
engineer in charge. Car doors shall be of stainless
steel grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will also be
S.S. 304 finished with emergency stop device,
mechanical door safety device, facility of auto/
attended mode. All car panel buttons and all floor
switches must be with brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour
shall be fully automatic centre opening/ telescopic
opening made of hairline finish steel grade of
with key holes and infrared curtains with Unlocking
facility from outside
[5] Appropriate battery operated emergency light in
the car along with alarm switch shall be provided.
Also, Emergency Light & Fan should start
immediately without any Time Delay as soon as
[6] Digital scrolling indicator system for up-down
arrow along with floor position indicator shall be
provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity with
Manual Rescue Operation ( Manual Cranking
[9] Audio visual indication in the lift car showing
over loading shall be provided such that doors kept
open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and
safety parameters shall be provided in control
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and
submission of calibration certificate submission,
door key holes in the floor doors, fireman switch
shall be provided.
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit should
be provided by the lift agency, along with the other
steel structure works, foundations for the machine
[16] In the hoist way fascia plate shall be provided
without any extra cost, where ever required as / if
directed by engineer in charge.
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage Under
Voltage protection and THD eliminator in circuit for
lift machine room and lift well with proper numbers
of light points, with fixtures, exhaust fan and plug
points shall be provided by the agency. Only
phase Power Supply shall be made available by
department in lift machine room. Necessary
Earthing as per Lift Act/Rules shall be arranged by
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without
any extra cost. (granite/marble fixing around all
landing door openings are not in lift agency’s
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all
necessary permission from lift inspector and other
[20] acrylic transparent licence/display A4 size
holder in lift car
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has to
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after
lift erection and provide report by third party
authorized by concern licensing authority
5.agency has to provide third party insurance upto
completion of free maintenance period and submit
the document for the same.
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly
visible when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should
be provided at appropriate height on the Rear &
Side Wall Panels in Lift Car.
[23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller,
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb
required for lift is in scope of work which rating
is sugested by CEICED Department (electrical
(B) SPECIAL FEATURES DESCRIPTION OF
LIFTS for PREMIUM category
1. Advanced control system dual 64 bit embedded
microprocessor with CANBUS Serial
Communication mode including Regenerative
power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS with
necessary online real time monitoring system
having necessary connectivity for remote monitoring
& other suitable supporting hardware & software
devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration
& brail mark with arrival gong and hall lantern & TFT
Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for car
and all Doors, All landing doors must have fire
rating up to 2 hours and car door must have multi-
level crisscross beam door protection.
4. To & fro communication system & wiring (i.e. car
, control room & guard room ) and Each elevator
are equipped with remote monitoring
system.agency has to provide mobile app and user
id and password for monitoring
8/10 passengers Ground + 1 upper floor with
Rated Speed of 1.0 m/sec -
AMC LOGO design as per given by department
to be embossed inside the lift car wall opp. To
1 (C) With General PLUS ADDITIONAL SPECIAL 1347854 No
FEATURES attached herewith. Prem. Cat.
SUB TOTAL of Passengers Elevator
9.1 Providing and erecting approved make split air-
conditioning unit consisting of copper condensing
unit with fan motor, hermetically sealed rotary
compressor with accessories etc. duly connected
separately erected evaporating unit and blower
motor with its accessories by means of extra
supplied proper insulated copper tubing,drain PVC
pipes suitable for ( cost includes powder coated
Stand, Eco Friendly green gas charging, 15A plug
top & Remote Control) with necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99)
Premium Category
9.1.1 1 [a] For 0.8 to 1.0 Ton Capacity 38986 No
9.1.2 1 (b) for 1.5 ton capacity 51923 No
9.1.3 2 (c) for 1.7 to 2.0 ton capacity 58706 No
9.2 Providing and erecting approved make Cassette
type split air-conditioning unit consisting of
condensing unit with fan motor, hermetically sealed
scroll/rotary compressor with accessories etc. duly
connected separately erected evaporating unit and
blower motor with its accessories by Eco friendly
Green gas charging & Internal copper wiring &
Remote control with necessary core cutting.
18 (D) for 4 ton capacity- 3Phase 103083 No
9.3 Supply, Installation, testing and commissioning
including vaccumiazation and Nitrogen testing of
following nominal sizes of soft/hard drawn copper
refrigerant piping for VRV system, complete with
fittings, with suitable adjustable ring type hanger
supports, jointing/brazing including accessories,
insulated with XPLE Class-0 tubular insulation/with
Class-0 closed cell elastometric nitrile rubber
tubular sleeves sections of specified thickness as
given below for Suction and Liquid lines, all
accessories as per specifications etc with
necessary refrigerant joint as required :
9.3.1 350 (B) 9.5 mm dia (OD) (Soft drawn) with tube 367 Mtr
thickness 1.2 mm with 19 mm thick insulation
9.3.2 350 (D) 15.86 mm dia (OD) (Soft drawn) with tube 658 Mtr
thickness 1.2 mm with 19 mm thick insulation
9.4 Supplying and installing MS angle , powder coated
/ Painted standard type of wall/floor stand mount for
outdoor unit of split AC of following capacity,
erected with necessary hardware materials as
9.4.1 1 (A) 25mm*25mm*3mm thick M.S angle suitable for 1305 No
upto 2 TR. Capacity of ac machine
9.4.2 3 (B) 35mm*35mm*5mm thick M.S angle suitable for 1496 No
above 2 TR to 4 TR Capacity of ac machine
9.4.3 40 Supplying and erecting insulated pair of soft copper 956 RMT
tubing including power and control cable,necessary
PVC drain pipes for Split AC machine up to 4 TR
9.5 Rigid UPVC drain pipe of 10 Kg/cm2. rating with
mm thick.nitrile rubber insulation.
9.6 345 Supplying & fixing 50mm thick TF quality expanded 409 Sqmtr
polystyrene for underdeck insulation on slab/wall
/shaft exposed to sun/atmosphere as per
specifications.
9.7 4 Supply, installation, testing and commissioning of 19575 No
ceiling mounted Single Inline fan - 1000 cfm ,
mm static pressure suitable for 220±10% volts,
Hz,single phase AC supply and complete with all
standard accessories such as motors,blades
etc.The casing of inline fan shall be accoustically
lined and shall be selected for lower noise level.
Fan motor shall have inbuilt speed controller.
Provision of connection with 1.5 sq. mm PVC
insulated FR copper conductor wire from the point
outlet to the fan as required shall be deemed to be
point outlet to the fan to be included in this cost.
9.8 SHEET METAL DUCT
Supply, installation, balancing and commissioning
of fabricated at site GSS sheet metal
rectangular/round ducting complete with neoprene
rubber gaskets, elbows, splitter dampers, vanes,
hangers, supports etc. as per approved drawings
and specifications of following sheet thickness
complete as required.
9.8.1 18 ( A ) 0.63 MM Sheet 1245.00 Sq Mtr
9.8.2 3 ( B ) 0.80 MM Sheet 1453.00 Sq Mtr
9.9 2 Supplying, fixing testing commissioning of Return 9301.00 Sqmtr
air diffuser of powder coated aluminium without
volume control dampers with anti smudge ring &
removable core and size & shape as per site
requirement and approved design..
SUB TOTAL of HVAC WORK
10.0 COMPREHENSIVE Maintenance
Annual Comprehensive Type Maintenance
Contract of ELECTRICAL + HVAC + passenger
elevator For 1-Year DLP + ONE Year
10.1 1 Annual comprehensive Type Maintenance FREE Year
Charges only During Guarentee / Defect
Liability period.
10.2 1 Annual comprehensive Type Maintenance 179536.71 Year
Charges for 1st Year after Guarentee / Defect
Liability period.
SUB-TOTAL Of ANNUAL comprehensive
maintenance contract Of Electrical / ELV /
HVAC and passenger elevators
Final specification and block diagram shall be
submitted by CCTV camera system vendor.
SITC of 1/2.8" CMOS 3MP IP Fixed Lens IR rugged
DOME Camera having progressive scanning
system , Pixels 3MP (2304 x 1296),Lens 2.8 mm,
Fixed, F1.4, Minimum Illumination color / BW:
Color: 0.002 Lux @ F1.6, BW 0 Lux IR ON,IR
Distance 40 Mtrs,Wide Dynamic Range
Db,Privacy Masking Off/On (5 Areas),Local Storage
Micro SD/SDHC/SDXC card slot (2TB),Gain Control
0 ~ 100%,Angle of View (H x V) H:87.2°
V:49.1°,Ethernet 10 Base-T/100 Base-TX Ethernet
(RJ-45),Protocols:IPv4, IPv6, TCP/IP, HTTP,
HTTPS, RTSP/RTP/RTCP, IGMP/Multicast, SMTP,
SNMP, DHCP, NTP, DNS, DDNS, CoS,
QoS,802.1X, UPnP, mDNS(Bonjour), UDP, ICMP,
ARP, TLS, SFTP,Body Material Aluminium +
Polycarbonate,Number of Video Streams 4,Ingress
Protection IP66, IP67, Event Notifi cation HTTPS,
HTTP, SMTP, ONVIF, Bit Rate 100 K ~ 6 Mbps
Certificates: FCC PART 15, CE (EN 55032), ICES-
003,CE (EN 55035),UL listed to UL/CSA 62368-1,
BIS IS 13252 (Part 1)/IEC 69050-1,RoHS, REACH,
WEEE,BIS ER, STQC
SITC of 1/2.8" CMOS 3MP IP Fixed Lens IR rugged
Bullet Camera having progressive scanning system
, Pixels 3MP (2304 x 1296),Lens 3.6 mm, Fixed,
F1.4, Minimum Illumination color / BW: Color:
Lux @ F1.6, BW 0 Lux IR ON,IR Distance
Mtrs,Wide Dynamic Range 130 Db,Privacy Masking
Off/On (5 Areas),Local Storage Micro
SD/SDHC/SDXC card slot (2TB),Gain Control 0 ~
100%,Angle of View (H x V) H:87.2°
V:49.1°,Ethernet 10 Base-T/100 Base-TX Ethernet
(RJ-45),Protocols:IPv4, IPv6, TCP/IP, HTTP,
HTTPS, RTSP/RTP/RTCP, IGMP/Multicast, SMTP,
SNMP, DHCP, NTP, DNS, DDNS, CoS,
QoS,802.1X, UPnP, mDNS(Bonjour), UDP, ICMP,
ARP, TLS, SFTP,Body Material Aluminium +
Polycarbonate,Number of Video Streams 4,Ingress
Protection IP66, IP67, Event Notifi cation HTTPS,
HTTP, SMTP, ONVIF, Bit Rate 100 K ~ 6 Mbps,
Certificates: FCC PART 15, CE (EN 55032), ICES-
003,CE (EN 55035),UL listed to UL/CSA 62368-1,
BIS IS 13252 (Part 1)/IEC 69050-1,RoHS, REACH,
WEEE,BIS ER, STQC
Supply , Installation , Testing and
commissioning of 32 Channel NVR (Network
Video Recorder) Embedded Linux based for
recording upto 32CH at 1080P, 960fps with
nos. SATA HDDs minimum 40TB storage or
more (recording requirement all cameras
recording at 2MP, 25fps for 30 days), H.265
HEVC/H.264/MJPEG codec decoding, Front
Panel with LEDs Indication for Power & HDDs
Status, 3 nos. USB, ONVIF S, Time Sync with
NTP, Encrypted Streaming & Control, 2-Way
Audio Line & Out, PTZ Operation Pan, Tilt,
Zoom, Support, Pre & Post Alarm Recording
Support, Recording/Evidence Clip Export to
USB, 16 Channel Synchronous Playback,
Playback control i.e Play, Pause, Stop, Fast
Forward, Backward, Speed Control, Timeline &
Zoom; Snapshot, Web Client, Central
Monitoring Software, iPhone; iPad; Android
based Mobile clients, 02HDMI & 01VGA Output,
04 On Board HDDS each up to 10TB, Alarm
Input (16 nos.), Alarm Output (04 nos.),
RS232/485, eSATA, 256 Mbps throughput,
NDAA Section 889 Compliant, Operating
Temperature –10°C to 55°C, Certification :
Certifications: ONVIF compliant, UL/CSA
62368-1, CE (EN 50130-4), FCC Part 15, EN
55032, NDAA & RoHS (EN63000) compliant.
Including fixing accessories and cable
termination with required connectors/Jack,
complete in all respect as per instruction of
engineer in-charge.
Supply Installation Testing & Commissioning of 8TB
Surveillance Harddisk
Supply, Installation, Testing and Commissioning of
43 inch, Professional LED Display Cum
Commercial TV with Android 11 & Inbuilt play store,
UHD resolution, 400 nits brightness, It's 24*7
usage, 50,000 hours life, 3 years warranty, Android
11 with inbuilt play store, Inbuilt wifi, Landscape /
Portrait mode, Inbuilt Bluetooth, 2 GB / 16 GB
Memory, Inbuilt SOC with HDMI cable
1.6 Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in
approved manner as directed
CAT 6 UTP Cable
Supplying & erecting approved make LAN cable of
following size in existing pipe as per direction
1.8.1 1 Supply, Installation, Testing & Commissioning 12053.57 No
of 9U wall mount rack.
3U wall mount Rack
1.9 1 SITC of 24 x 10/100/1000BASE-T PoE ports 4 x 31680.00 No
Gigabit RJ45/SFP Combo ports Advanced L2
switching and security features L2+ Static Routing
Optional “standard mode” or “surveillance mode”
management user interface 193 W PoE budget
(Including Five year free maintenance with
1.10 3 SITC of 8 x 10/100/1000BASE-T PoE ports 2 x 18218.00 No
Gigabit SFP ports Advanced L2 switching and
security features L2+ Static Routing Optional
“standard mode” or surveillance mode”
management user interface 65W PoE budget
[Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
Supply, Installation Testing & Commissioning
Mtr. HDMI Interface Cable as per the detailed
Specifications supports transmission of 4K Signals
as per the detailed Specifications
1.12 21 Supply, installation, fixing, testing and 440.00 No
commissioning of PVC Junction box for CCTV
Camera, IP65, outdoor application. Junction Box
size will be as per vendor's requirement and site
SITC of Patch Panel Cat 6 UTP Keystone Type-
Port-Fully Loaded (Including Five year free
maintenance with guarantee)
1.14 21 SITC of Jack Cat 6 Keystone UTP (Including Five 160.00 No
year free maintenance with guarantee)
SITC of CAT6 UTP 24AWG PATCH
CORD:1M,Plug 30U' Snag less (Including Five
year free maintenance with guarantee)
SUB -TOTAL OF CCTV SYSTEM
2.0 COMPREHENSIVE Maintenance
Annual Comprehensive Type Maintenance
Contract of CCTV System For 1-Year DLP +
2.1 1 Annual comprehensive Type Maintenance FREE Year
Charges only During Guarentee / Defect
Liability period.
2.2 1 Annual comprehensive Type Maintenance 16370.60 Year
Charges for 1st Year after Guarentee / Defect
Liability period.
SUB -TOTAL OF CCTV Comprehensive
Maintenance work
I. No. Qty Items Rate Per
FIRE FIGHTING SYSTEM
Design,Drawing, Supply,installing,testing
and commissioning of FIRE HYDRANT
Internal / External Hydrant
1.1.1 Supplying, Installation, Testing and Commissioning
of electric driven main Hydrant fire pump
suitable for automatic operation and consisting of
following: complete in all respect as required.
1 a) Horizontal type, single stage, centrifugal, end 143626.00 Set
suction pump of cast iron body & bronze impeller
with stainless steel shaft, mechanical seal to ensure
a minimum pressure of 3.5 kg/sq. cm. at highest
and farthest outlet at specified flow of 1680 lpm at
56 Mtr. head conforming to IS 1520.with suitable
size of footvalve confirming to IS 4038, Pressure
rating PN2 , preventing entry of foreign body to
pump through suction pipe, perfectly flat seating
surfaces for good sealing.
b) Suitable HP Squirrel cage induction motor,
TEFC, suitable for opertion on 415 volts, 3 phase
50 Hz. AC with IP 55 class protection for enclosure,
horizontal foot mounted type with Class - 'F'
insulation, conforming to IS-325.
c) M.S. fabricated Common base plate, coupling,
coupling guard, foundation bolts etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
The pump shall be capable of giving not less than
150% discharge at ahead not less than 65% of the
1.1.2 1 Supplying, Installation, Testing and Commissioning 61717.00 Set
of electric driven pressurisation pump suitable
for automatic operation and consisting of following:
complete in all respect as required
a) Horizontal type, single stage, centrifugal, end
suction pump of cast iron body and bronze impeller
with stainless steel shaft, mechanical seal at
specified flow of 180 lpm at 56/70 m. head
conforming to IS: 1520.with suitable size of
footvalve confirming to IS 4038, Pressure rating
PN2 , preventing entry of foreign body to pump
through suction pipe, perfectly flat seating surfaces
for good sealing.
b) Suitable HP Squirrel cage induction motor TEFC
type suitable for operation on 415 volts, 3 phase
Hz. AC with IP 55 Class of protection for enclosure,
horizontal foot mounted type with Class F'
insulation, conforming to IS :
c) M.S. fabricated Common base plate, flexible
rubber coupling, coupling guard, foundtion bolts etc.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1.1.3 ENGINE DRIVEN PUMP
1 Supplying, Installation, Testing and Commissioning 506181.00 Set
of diesel engine driven main fire pump suitable
for automatic operation and consisting of following:
complete in all respect as required
a) Horizontal type, single stage, centrifugal, end
suction pump of cast iron body and bronze impeller
with stainless steel shaft, mechanical seal to ensure
a minimum pressure of 3.5 kg/sq. cm at highest and
farthest outlet at specified flow of 2280 lpm at
m. head conforming to IS
b) Suitable HP, 1500 /1800 RPM water cooled
with radiator, diesel engine conforming to relevant
BS & IS standard complete with auto starting
mechanism, 12/24 volts electric starting equipment,
180 AH lead acid battery with battery stand,
exhaust pipe extended upto 6 m. outside pump
house duly insulated with 50 mm thick glass wool
with 1.0 mm. thick aluminium sheet cladding,
residential silencer, instruments and protection as
per specification, stop solenoid for auto stop in the
event of fault with audio indications, painted with
post office red colour etc. as required.
c) One 200 Ltr capacity day oil storage tank
fabricated from 3 mm thick M.S. plates. Tank shall
be provided with inlet, outlet, overflow, air vent,
drain connections, filling connection & level
indicator. Tank shall be mounted on a suitable steel
structure (Painted with 2 coats of red oxide paint).
Tank shall be provided with two or more coats of
synthetic enamel paint outside over two coats of red
d) M.S. Fabricated Common base plate, coupling,
coupling guard, foundation bolts etc. as required.
e) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1 A. Incoming Feeder:- 258883.00 No
(i) 1 No of 125 A,25KA, 415V,FP MCCB with
Thermalmagnetic Based Releases having O/C, S/C
,E/F protection, Digital ELR 96x96mm with CBCT,
FP Spreader Terminals 1 set= 8 Pcs, Extended
Rotory Handle for MCCB, 240V AC Shunt Trip coil
(ii) LED type indicating Lamp with suitable rating
Amp SP MCB:- 1 Set (each set comprise of R,Y,B)
(iii) Digital type 3 phase Multi function Meter with
suitable rating of MCB & 3 Nos. of single core
epoxy resin cast type CTs of 125/5 Amps, 10 VA,
CL 1.0 ratings -1 Set.
415 V, 125 Amps, FP Aluminium Busbars with Heat
shrinkable color code insulation sleeves.
OUTGOINGS:-( All outgoing feeders for pumps
should have digital Ammeter with selector switches
and LED type ON,OFF,Trip indicating Lamps )
1 sets - 80 A, 25kA TPN MCCB, Ics=100% Icu, with
fully automatic Star/Delta starter suitable for 60 HP
pump with overload protection, current sensing type
single phase preventor complete with all
acceessories and internal wiring required for
automatic operation,selector switch for local/remote,
auto/manual/OFF operation.
1 no.40A,10KA MCB Ics=100%,Extended Rotry
handle with TM release having O/C & S/C
protection with 10 HP fully automatic star/ delta
starter , current sensing type, Single Phase
Preventer, ON/OFF Push Button & LED type
Indicating lamps complete with all accessories and
internal wiring required for automatic operation,
selector switch, for local/remote, auto/manual
Diesel Engine Control.
Control for Diesel Engine comprising:
i) Auto/Manual selector switch & 3 attempt starting
device, timers and relays as required, push buttons,
start/stop in manual mode.
ii) LED type Indication lamp for High/Low Lub. Oil
pressure, High Water Temp and Engine ON
iii) Battery charger suitable for 12 V/24 V DC with
boost and trickle selector switch, 0-30 V DC volt
meter, 0-20 Amp DC Ammeter.
iv) All standard relays, accessories for automatic
operation of diesel engine, wiring with 1.5 sq mm
PVC insulated copper wire between various
sensors and system controller / starter, suitable size
cable for battery charging etc. as required.
System Controller
Designing, Supply, Installation, Testing and
Commissioning of system controller to control
operation of Main Electric Fire Pump, Diesel Pump,
Pressurisation Pump, Terrace Pump in sequence
as per specification consisting of relays, timers,
sensors, annunciation window for fault indication,
control wiring complete as specification.
3 NOS. 25A DP MCB " C " Curve
1.3 PRESSURE GAUGES , Air vessel AND
1.3.1 3 Providing, fixing, testing and commissioning of 1329.87 Set
Pressure Switch with Needle Valve.
1.3.2 3 Providing and fixing in position the industrial 967.73 Set
type pressure gauges with gun metal / brass
valves complete as required
1.4 Providing, laying, testing & commissioning of 'C'
class heavy duty MS Pipe conforming to IS
i/c fittings like elbows, tees, flanges, tapers, nuts
bolts, gaskets etc., in ground including excavation
and providing cement concrete blocks as support,
anticorrosive treatment with coaltar/asphalt tape as
per IS 10221, refilling the trench etc. of following
sizes complete as required .( For HYDRANT )
25 100MM Dia 2300.63 Mtr
1.5 Providing, laying, testing & commissioning of 'C'
class heavy duty MS pipe conforming to IS 3589/IS
1239 including Welding, fittings like elbows, tees,
flanges,tapers, nuts bolts, gaskets etc. and fixing
the pipe on the wall/ceiling with suitable
clamp/support frame and painting with two or more
coats of synthetic enamel paint of required shade
complete as required :
1.5.9 5 200mm Dia ( wall thickness 6.3mm ) 4938.01 Mtr
1.6 Supplying and fixing Single headed internal /
External hydrant valve with 1 No. 63 mm dia
instantaneous FM Gunmetal/Stainless Steel
coupling and cast iron wheel,ISI marked,
conforming to IS 5290 (type A) with blank
Gunmetal/Stainless Steel cap and chain as required
9 Single headed Stainless steel 5549.04 No
1.7 8 Providing, fixing, testing and commissioning of Wall 10499.50 No
mounting swing type first aid Fire Hose Reel with
drum, hanging bracket, 30 M x 25 mm dia high
pressure hose reel tubing as per IS:884 with shut
nozzle and ball valve and all required accessories.
1.8 8 Supplying, Installation, Testing and commissioning 4726.50 No
of weather proof Fire Hose cabinet size 900x
600x300mm to house fire hydrant & hose,
including all other related accessories fabricated
from M.S. sheet (16 Gauge) of fully welded
construction having front door with locking
arrangement, partially glazed with 4 mm thick glass.
Cabinet shall be powder coated & painted with post
office red colour
1.9 16 Providing ISI marked RRL (IS : 636, type‐A) fire 4020.55 No
hose pipe 15 meter long and 63 mm dia with ISI
marked (IS : 903) Stainless steel male and female
coupling bound and rivetted to hose pipes with
copper rivets and copper wire complete as required.
1.10 8 Providing Stainless steel ISI marked 63 mm. dia. 1502.28 No
male Instantaneous pattern short branch pipes with
20 mm dia. Nozzle as per IS : 903, suitable for
Kg/sqcm operating pressure and suitable for
interconnections to hose pipe coupling as required.
1.11 Supplying and fixing of fire brigade connection of
cast iron body with gun metal male instantaneous
inlet couplings complete with cap and chain as
reqd. for suitable dia MS pipe connection
conforming to IS
1 2 way - 100 mm dia M.S. Pipe 6094.09 No
1.12 2 Providing, fixing, testing and commissioning of 25 1949.25 No
mm dia Air Release Valve and Ball Valve
assembly on top of each riser for Air release
1.13 1 Providing, fixing, testing and commissioning 4940.68 No
Pressure Relieaf Valve 25mm dia with Ball Valve.
1.14 9 Supplying and fixing orifice plate made out of 6 1932.76 No
mm thick stainless steel (Grade 304) with orifice of
required size to be fitted between flange & landing
valve of external and internal hydrants to reduce
pressure at the outlet to the level of 3.5 kg/cm2
complete as required.
1.15 Supplying, fixing, testing and commissioning of
butterfly valve of PN 1.6 rating with
bronze/gunmetal seat duly ISI marked complete
with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required :
1.16 Providing, installation, testing and commissioning of
non-return valve of following sizes confirming to
IS:5312 complete with rubber gasket, GI bolts,
nuts,washers etc.as required :
1.17 Providing, installation, testing and commissioning of
stainless steel Y-strainer fabricated out of 1.6 mm
thick stainless steel, Grade 304, sheet with 3 mm
dia holes with stainless steel flange.
1.18 8 Supply, Installation, Testing and Commissioning of 737.27 No
Brass. Ball Valves with all fittings required. 25mm
1.19 Supplying and erecting Flexible PVC insulated
multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as
80 f) 1.50 Sq.mm 4 core round PVC sheathed 67.00 Mtr
1.20 2 SITC of fire pump start stop push buttons in box. 954.50 No
1.21 1 SITC of 2 Zone standalone Fire Alarm control 9300.00 No
Panel, 16X2 Character LCD Display, provision for
zone wise contact and sounder. Panel does not
have provision to connect Repeater Panel. Make:
Ravel Approval: CE Mark. (Including Five year free
maintenance with guarantee)
1.22 Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in
approved manner as directed
1.23 2 Supply, Installation, Testing and Commissioning of 1201.75 No
Single action Manual Pull Station.Shock and
Vibration Resistant, pull Down Lever Remains
Down Until Reset. Shall be Polarity Insensitive (with
all mounting accessories , complete with Junction
Box for mooting on Surface, Cable lugs at Ends,
cable compression glands, cable tags and ferruling.
1.24 2 Supply, Installation, Testing and Commissioning of 1201.75 No
Conventional Sounder cum strobe having tone
settings with range of 95dbA and field selectable
15/30/75/110 candelas.(with all mounting
accessories , complete with Junction Box for
mooting on surface, cable lugs at ends, cable
compression glands, cable tags and Ferruling.)
CABLES AND TERMINATIONS
1.25 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps or
in existing trench / pipe at road crossing or floor of
following size of cable.
1.25.1 36 (B) 3 core 4 Sq. mm 285.00 Mtr
1.25.2 15 (G) 3 core 6 Sq. mm 392.00 Mtr
1.26 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps or
in existing trench / pipe at road crossing or floor of
following size of cable.
1.27 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps or
in existing trench / pipe at road crossing or floor of
following size of cables.
1.28 Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables.
1.28.2 4 (C) 2 to 4 core 10 Sq. mm 38.00 No
1.28.3 2 (D) 2 to 4 core 16 Sq. mm 47.00 No
1.29 Solder less crimping type Copper lugs conforming
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner.
1.30 Providing and fixing approved make Perforated C
type cable tray. Made from sheet steel. The cable
tray should be single or double bended as per
required and as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS
2629/4759. with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like nut -
bolt and washers etc. erection with necessary
support( included) as per Specification and as per
instruction of engineer in charge..
1.31 1 Supply, installation,testing and commissioning of 12230.00 E.a.
Chemical Earthing with UL Certified 17.2mm Dia. X
3000mm Long 254 Micron-Copper bonded M.S.
Rod manufactured as per IEC 62561-2 with 25Kg
Bentonite powder plus " U " bolt rod clamp
complete with Lockable high performence chamber
suitable & tested for 5000T capacity with SS
Hardware.or equivalent
1.32 2 Supplying, Installation, Testing and commissioning 19676.50 No
Sewage water submersible pumping sets of CI
casing & impeller, SS shaft, including with inbuilt
water level sensors for operating the pumps
automatically and all accessories suitable for
operation on 220 V-240 V, single phase, 50 Hz. AC
supply etc. as reqd.
> 10 mm solid handling capacity,Minimum
Capacity - 50 LPM,Minimum Head >
1.33 1 Charges of Preparing Design , Drawings ,Testing 76271.19 job
of Fire Fighting System with necessary Approval
from Local Fire authority.( Including Pre-NOC and
NOC from Fire authority. )
1.34 Providing, fixing, testing and commissioning of
below Auto Glow Signages.
1.34.2 2 Fire Equipment: 4" X 12" 514.97 No
1.34.3 2 In case of Fire, do not use lift, use staircase: 8" x 8" 650.00 No
1.34.4 2 Fire Lift 4"X12" 514.97 No
1.34.5 2 Fire Extinguishers 8"x 4" 480.00 No
1.34.6 2 Floor Sign": 4" X 12" 514.97 No
1.34.7 2 Fire Hydrant 4” X 12” 514.97 No
1.34.8 2 Fire Hose Reel.4” X 12” 514.97 No
1.34.9 2 DCP Extinguisher 8"x 4" 480.00 No
1.34.10 2 CO2 Extinguisher 8"X 4" 480.00 No
1.35 Providing, fixing, testing & commissioning of 15mm
dia quartzoid bulb type sprinklers of rating with
required accessories :
1.35.1 70 Pendent Sprinkler 57°C standard response (K-80) 362.25 No
1.35.2 2 Pendent Sprinkler 68°C standard response (K-80) 471.50 No
1.36 Supplying, installation, testing & commissioning of
sprinkler flexible pipe (UL Listed) of stainless steel
complete with 15 NPT on reducer thread with
maximum working pressure of 175 PSI test
pressure of 875 PSI (Burst) with branch line (Inlet)
25mm NPT male thread to sprinkler head (Outlet)
15mm NPT female thread with reducer, nipple,
side brackets,center bracket, stockbar of following
sizes complete as required etc of following sizes as
1.37 1 Providing fixing, testing and commissioning of 4939.25 No
Drainning & Testing Assembly 25mm dia with Sight
Glass , Union joint , Ball Valve & Drain Valve.
SUB-TOTAL OF FIRE HYDRANT System
2.0 FIRE EXTINGUISHERS AND LIGHTNING
2.1 FIRE EXTINGUISHER
2.1.1 3 FIRE EXTINGUISHER Supplying, Installation, 2724.25 No
Testing and commissioning of Dry Chemical
Powder (DCP) 6 Kg Fire Extinguisher Mono
Ammonium Phosphate Powder 40, Stored Pressure
Type, Pressure Gauge, Controllable discharge
mechanism Class A, Rating 3A & Class B rating
21B as per IS 15683 ISI MARK (ABC Dry Chemical
Powder - MAP 40%)fitted with required accessories
including wall suspension brackets.
2.1.2 3 Supplying, fixing, testing and commissioning of CO2 6526.00 No
type Fire Extinguisher of capacity 4.5 kg filled with
Co2 Gas as per IS 15222 with controll discharge
mechanismfitted with Hose & Horn applicable on
Class B fire rating 21B confirms to IS
bearing ISI mark. Co2 Cylinder as per IS
2.1.3 1 Providing & fixing of ISI marked water CO2 type 3450.00 No
Portable fire extingusher,9 LTR capacity, Hydraulic
test pressure 35Kgf/ cm2, Discharge range
Mtr,Average discharge time: Min. 13Sec,Fire Rating
3A,Grade: IS:15683.
2.1.4 1 Providing & fixing of ISI marked, Squeeze Grip 4200.00 No
Cartridge Type water CO2 type Portable fire
extingusher,9 LTR capacity, Hydraulic test
pressure 35Kgf/ cm2, Discharge range
Mtr,Average discharge time: Min. 13Sec,Fire Rating
3A,Grade: IS:15683.
2.1.5 1 Providing,fixing, testing and commissioning of 10Kg 2950.00 No
Modular type fire extinguisher having Nitrogen
expellant ,ceiling mounted,Sprinkler Nozzle is gas
tight the release temperature is adjusted with
sprinkler imported bulb set at 57 degree C or
degree C ,coverage area 4 to 5 sqmtr,
2.2 LIGHTNING ARRESTER
2.2.1 6 SITC of Vertical Air Termination Solid aluminium 9323.00 No
with Base- 10 mm dia and 1000 mm long. Air
Termination Base tested for conditioning, Ageing
Test & Lightning impulse current withstand test:
kA of 10/350µs waveform in an accredited Third
party laboratory as per 6.3 & 6.4 of IEC 62561-1
2017 protocol with MAST 34mm dia 3000 mm long-
Cold Galvanized
2.2.2 140 SITC of 8 mm dia solid Aluminium Conductor for 297.00 Mtr
roof top mesh grid and tested as per IEC 62561-
conducted in the Govt. accredited thirty party
laboratory to meet the requirement of IS/IEC
with Required Accessories - Aluminium Holding
clamp at every 1 mtr distance, Aluminium/SS cross
splicer at every crossing of Alu. conductor,
Expansion piece with connectors at every 20 mtr
distance, Aluminium straight Splicer to connect
conductors. All Accessories should be tested as
per IEC 62561-1 2018 Cl. 6.3 for conditioning &
Ageing Test & 6.4 for Lightning impulse current
withstand test: 100 kA of 10/350µs
waveform(Ageing & Electrical test ) conducted in a
sequence manner & tested in the Govt. accredited
Third party laboratory to meet the requirements of
2.2.3 60 SITC of Galvanized Steel Flat 25x6 mm thickness 153.00 Mtr
from earth electrode directly in ground as required.
Zinc coating: 500 g/m square (Approx:70 micron
coating) tested and used exclusively for lightning
protection earthing system and ring equipotential
2.2.4 6 SITC of 14.2 mm dia 3 mtr long Earth electrode of per set No
High tensile steel electrode with 250 micron copper
bonding & 1 bag of Carbon fill Based environment
friendly backfill tested as per IEC 62561-7 in NABL
accredited Laboratory and suitable stainless Steel
double sided clamp. Eco Friendly rust proof heavy
duty weather proof Polyethylene Earth Pit Chamber
with following dimensions :254 mm dia (top),
mm dia (bottom) & 260 mm (height).
SUB TOTAL of FIRE EXTINGUISER &
Lightning Arrester
FIRE DETCTION & FIRE ALARM SYSTEM
3.1 1 SITC of Microprocessor based Net-workable 118852.50 No
Analogue Addressable Fire Alarm Control
Panel. The Panel shall be compliant with EN54-2,
EN54-4 and approved by LPCB. The Fire Alarm
Control Panel shall have inbuilt one loop. The
Panel must have large graphic display. The Panel
must also have the capability to take Addressable
Intelligent Wired and Wireless Devices on same
loop. Each loop shall have a capacity of
analogue Addressable devices and 127 Base
sounders/Base Sounder Beacons. The Panel shall
have 240 V AC power supply along with automatic
Battery Charger. Non-Networkable
Approved by LPCB (Including Five year free
maintenance with guarantee)
3.2 75 SITC of Analogue Addressable Multi- Sensor 3597.20 No
which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's allow
360 degree viewing, User selectable sensitivity
modes 1% to 4.5% obs/m, Incorporate Optical and
dual Heat elements, lock mechanism (sensor to
base), Electronically addressed, Pulsing/non-
pulsing controlled from panel. Approved by LPCB &
VdS. (Including Five year free maintenance with
3.3 4 SITC of Analogue Addressable Multi- Heat Sensor 3498.30 No
which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's allow
360 degree viewing, User selectable sensitivity
modes 0 to 88 degree Celsius, Incorporates Fixed
Temperature and Rate Of Rise Heat elements, lock
mechanism (sensor to base), Electronically
addressed, Pulsing/non-pulsing controlled from
panel. Approved by LPCB (EN54: Part 5) (Including
Five year free maintenance with guarantee)
3.4 79 SITC of sensor common mounting base, includes 354.20 No
stainless steel contacts, slim profile - only 8mm,
quick connection via square cable clamps, facility
for remote indicator, Approved by LPCB (Including
Five year free maintenance with guarantee)
3.5 6 Supply,Instllation,Testing and Commissioning of 2477.10 No
Fault isolator Module capable of monitoring shorted
loop circuit and automatically restore
communications when shorted conditions are
corrected (Including Five year free maintenance
with guarantee)
3.6 20 Supplying, installation, testing & commissioning of 193.20 No
response indicator on surface/recessed MS Box
having two LED, metallic cover complete with all
connections etc as required.
3.7 4 SITC of Manual Call Point approved to EN54- 4191.75 No
11:2001, Approved by LPCB Easy to install, push-fit
wiring terminals (Including Five year free
maintenance with guarantee)
3.8 4 SITC of Analogue addressable loop powered Base 7442.80 No
Sounder, variable sound output 50 ~ 98 dB(A) (±2
dB(A)) output at 1 metre, 51 user-selectable tones
(all tones EN54-3 compatible), Auto shutdown
feature prevents noise-pollution, Approved by LPCB
& VdS (Including Five year free maintenance with
3.9 1020 Supplying & laying of 2x1.5 sqmm fire alarm 135.70 Mtr
armoured cable, 600/1000V rated with annealed
copper conductor having XLPE insulation, steel
wire armouring & FRLS outer sheath complete
SUB -TOTAL OF FIRE DETECTION&
4.0 Annual Comprehensive Type Maintenance
Contract of for Above Fire Fighting System For
1-Year DLP + ONE Year
Every six months Testing certificates with
Photographs should be sent to competent
authority by concern contractor.
4.1 1 Annual comprehensive Type Maintenance Charges 0.00 Year
only During 1st Year DLP / Defect Liability period.
4.2 1 Annual comprehensive Type Maintenance Charges 85360.00 Year
for 1st Year after Guarentee / Defect Liability
SUB TOTAL of Annual Comprehensive
Maintenance of Fire Fighting Sytem
LANDSCAPING WORK :
I. No. Qty Items Unit Rate Per Amount
LAYING OUT LAWN – After excavating soil
upto 30 cm. depth & removing unwanted stuff,
stones etc. Preparing soil for planting by
supplying and mixing 6 inch river fine site and
0.5 cmt FYM maximum 100 sqmt of lawn area
and doing termicide @ 1 fit / 100 sqmt area
and planting selection 1 type / approved lawn
grass at maximum 6 cm x 6 cm distance and
maintain it upto 120 days. Maintainance
include all operations i.e. watering, grass
cutting, gap filling, applying of fertizer if require
Supplying, Spreading and leveling of good
earth like firtile soil as directed etc compt.
Supplying, Spreading and leveling of good
3 280 quality river Kap Filling 100 mm as directed etc 575.00 Cmt.
Supply and Planting saplings of Hedge plants
like kadvi mahendi, karmda, dyuranta,
4 700 nikodeviya etc. specifies bag size is 4 inch x 15.00 Nos
6 inch, well established & free from disease at
site. as per the instructions
Supply and Planting saplings of Ficus panda,
Ficus benjamina, Ficus benjamina variegated,
5 280 Ficus longisland bag size is 13 inch x 13 inch, 150.00 Nos
well branched, well established & free from
disease at site as per the instructions
Supply and Planting saplings of (Jasud,
Ixora, Ticoma Gaudi-chaudi, Gultora,
Jetropha, Haemeliya, Chandani, Mogaro,
Galfemia, , Allamenda, Desi Gulab, Euphorbia
mili, Jasud Hybrid, Chandani double,
6 150 Madhukamini, Madhumalti, Ticoma Capensis, 85.00 Nos
Ixora draft, Nikadevia, English Karen etc.)
having height of minimum 2.00 to 2.5 ft. and
bag size is 8 inch x 10 inch, well branched,
well established & free from disease at site as
per the instructions.
Supply and Planting saplings of Golden
Bamboo having height of minimum 5 to 6 ft.
7 250 and bag size is 8 inch x 10 inch, well 45.00 Nos
branched, well established & free from disease
at site as per the instructions.
Supply and Planting saplings of Palm(Botal
palm,foxtel) having height of minimum
8 40 to 12.00 ft. and bag size is 21 inch x 21 inch, 3500.00 Nos
well branched, well established & free from
disease at site as per the instructions
Supply and Planting saplings of champa
(deshi) having height of minimum 8 to 10 ft.
9 40 and bag size is 15 inch x 16 inch, well 450.00 Nos
branched, well established & free from disease
at site as per the instructions.
Supply, Spreading and leveling of Brick dust
10 20 (Chharu) particle size having maximum 10 1300.00 Cmt
Supply Saplings and Planting of trees
species as specified ( Alstonia scholaris,
Erythrina indica, Jacaranda
mimosifolia,Delonix regia , Anthocephalus
cadamba, Spathodea companulata,Neem
(Azadirachta indica), Lagerstromia speciosa
Tabebuia argentea, Cordia sebestena,
Mimusops elengi, Bauhinia blakeana, Kigelia
pinnata, Cassia fistula, Banyan, Ficus
11 140 religiosa, Peltophoroum, Bottle brush, Silver 250.00 Nos
Oak, Billi, Mahagony, Pendula, Desi
Asopalav,Sevan, Badam, Ficus infectoria,
Pinkesiya, Millingtonia hotensis, Rain Tree,
Bakm limdi, kasid, Ashok tree, parkia,
Tabebuia Rosea, millettia, etc.) having height
of minimum 7.00 to 8.0 ft. and bag size is
inch x 13 inch, well branched, well established
& free from disease at site as per the
Supplying insecticides at site well packed in
bottle of 20 litre. weight including royalty and 20 L
carriage with all leads and lifts (product to be Bottle
brought in company sealed packing only)
Signature of Bidder
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- WEST ZONE
Name of Work : CONSTRUCTION OF PHYSIOTHERAPY& YOGA BUILDING AT F.P.NO :- 287-2-2, T.P.NO :-
IN RANIP WARD, WEST ZONE, AHMEDABAD.
FINANCIAL BID (Online Only)
Sr.No. Description Amount
1 Amount For Civil Work Rs.4,47,06,575.80
2 Amount For Electrical Work Rs.
3 Amount For CCTV & ELV Work Rs.
4 Amount For Fire Fighting System Work Rs.
5 Amount For Landscaping Work Rs.
I/We am/are willing to carry out work at ______% above / below (should be written in figures and words)
the estimated cost mentioned above.
Estimated cost put to tender : Rs. 5,71,45,526.97 Estimated cost put to tender : Rs.
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Signature of contractor Additional City Engineer ( W.Z. )
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
PROJECT DRAWINGS.pdf
RANIP PHC Final Price Bid.pdf
RANIP PHC Vol-1 Part B.pdf
RANIP PHC Vol-1 Part C.pdf
RANIP PHC Vol-1 Part D.pdf
RANIP PHC Vol-1 Part E.pdf
RANIP PHC Vol-1 Part A.pdf
Download all tender documents and submit your bid