Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹11.8 LAccepted-AOC | 1st | Accepted-AOC Lowest | |
| 2 | 2nd₹13.1 L+₹1.2 L (10.2%)Accepted-AOC | 2nd | Accepted-AOC Highest |
Tender Value
₹11.9 L
EMD Value
₹30,000
Closing Date
31 Oct 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
Assistant Executive Engineer Assistant Executive Engineer
SDRF-Urgent Rectification works to Poovanchira Aqueduct at 12-000Km to 12-240 km
2020_Irrig_393024_1
54/AEE/2020-21
Open Tender
Civil Works - Canal
Item Rate
120 days
Chuvannamannu-Pattikkad
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,400
online
₹30,000
30 Dec 2020
19 Oct 2020
2 Nov 2020
19 Oct 2020
31 Oct 2020
19 Oct 2020
60 days
Amount
Scheme 1 Chainage 12/020 to 12/030km
14.17 : Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead.as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil as per the direction of departmental officers at site
Scheme 2 Ch.12/030 to 12/040
14.17 : Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead.as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
5.25 : Providing and fixing in position copper plate as per design for expansion joints.as per the direction of departmental officers at site
Scheme 3 Ch 12/040 to 12/052 km
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
14.49.1 : Painting ( one or more coats ) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work75 mm diameter pipes as per the direction of departmental officers at site
od31792/2020_2021/IA : Supplying, welding and fixing 75 x 5 mm iron flat to the existing ends of braces fixing in the bed of aqueduct diagonally at frequent intervels to withstand the overturning due to water pressure. all necessary scrapping the old bit, applying a priming coat of approved steel primer are essential. as per the direction of departmental officers at site
Scheme 4 For 12/052 to 12/064Km
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
14.49.1 : Painting ( one or more coats ) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work75 mm diameter pipes as per the direction of departmental officers at site
od31792/2020_2021/IA : Supplying, welding and fixing 75 x 5 mm iron flat to the existing ends of braces fixing in the bed of aqueduct diagonally at frequent intervels to withstand the overturning due to water pressure. all necessary scrapping the old bit, applying a priming coat of approved steel primer are essential.
Scheme 5 For 12/064 to 12/076Km
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
14.49.1 : Painting ( one or more coats ) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work75 mm diameter pipes as per the direction of departmental officers at site
od31792/2020_2021/IA : Supplying, welding and fixing 75 x 5 mm iron flat to the existing ends of braces fixing in the bed of aqueduct diagonally at frequent intervels to withstand the overturning due to water pressure. all necessary scrapping the old bit, applying a priming coat of approved steel primer are essential.as per the direction of departmental officers at site
Scheme 6 for 12/076 to 12/088
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
14.49.1 : Painting ( one or more coats ) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work75 mm diameter pipes as per the direction of departmental officers at site
od31792/2020_2021/IA : Supplying, welding and fixing 75 x 5 mm iron flat to the existing ends of braces fixing in the bed of aqueduct diagonally at frequent intervels to withstand the overturning due to water pressure. all necessary scrapping the old bit, applying a priming coat of approved steel primer are essential.
Scheme 7 for 12/088 to 12/100
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
14.49.1 : Painting ( one or more coats ) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture on old work75 mm diameter pipes as per the direction of departmental officers at site
od31792/2020_2021/IA : Supplying, welding and fixing 75 x 5 mm iron flat to the existing ends of braces fixing in the bed of aqueduct diagonally at frequent intervels to withstand the overturning due to water pressure. all necessary scrapping the old bit, applying a priming coat of approved steel primer are essential.as per the direction of departmental officers at site
Scheme 8 for 12/100 to 12/110 Km
14.17 : Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead.as per the direction of departmental officers at site
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make as per the direction of departmental officers at site
od31791/2020_2021/IA : Providing and fixing welded mesh of size 50 x50 mm to be fixed & firmly anchored to the concretesurface by means of nail and proper tying or welding , including the cost of materials, labour, tool & plants as approvedby Engineer-in-charge.as per the direction of departmental officers at site
26.38.2 : Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge<br> Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.50mm thick in Grade M 25 with cement content not less than 330 kg per cum as per the direction of departmental officers at site
5.25 : Providing and fixing in position copper plate as per design for expansion joints.as per the direction of departmental officers at site
Paul Alias
Bidder Name
Paul Alias
SURESH P S
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_559116.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .