Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹9.3 L+₹5,125.02 (0.56%)Rejected-AOC | L2 | Rejected-AOC Second Lowest |
Tender Value
₹8.4 L
EMD Value
₹12,700
Closing Date
1 Sept 2021, 6:00 pmClosed
The Executive Engineer Electrical HEED Harbor Engi
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Chief Hydrographic survey Wing Office at Kamalewaram_Supply and Installation of Diesel Generator set_UPS and Automatic Water level controller
2021_HED_435487_1
23/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
90 days
kamleswaram
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,250
Yes
₹12,700
Yes
17 Nov 2021
17 Aug 2021
3 Sept 2021
17 Aug 2021
1 Sept 2021
17 Aug 2021
Amount
Supply,installation,testing and commissioning of diesel engine driven generator set rated 15 kVA/12 kW, silent type,water cooled,radiator type ,four stroke electric start with accoustic enclousure conforming to current CPCB norms. DG set shall have standard control panel with necessary engine protection and monitoring relay,remote start stop ,auto start and necessary controls.The engine shall be capable of taking 10% overload for one hour after 12 hours of continuous operation.The Synchronous Alternator shall be brushless,self exited,self regulated, drip proof screen protected,class F/H insulation suitable for continuous operation at 1500 rpm.(Preferred make- Engine: CUMINS, KIRLOSKAR , Alternator - KIRLOSKAR, STAMFORD). Generating 415 V ac ,+/- 5 % at 0.8 pf ,50Hz,0.85 load factor,3 phase,4 wire system conforming to BS 2613 and IS 4722. DG set shall have inbuilt diesel day tank with all necessary fuel piping,valves, fitting etc.Both Engine and Alternator shall be mounted on common channel MS base frame and with standard accessories such as antivibration pads,lead acid batteries specified by engine manufacturer, Engine driven alternator ,battery charging along with leads,speed governor,residential silencer,external battery charger with float and boost charger.
Exhaust piping with MS Class B pipe of 65mm dia, heavy duty bend and flexible connector, MS support etc.including 2 coat heat resistant painting.
Making thermal insulation on exhaust piping (using 100 mm thick rock wool & Aluminium cladding)
Leading to plinth and fixing of DG Set on foundation and alingment setting & installation of DG set (MR)
filling diesel (MR)
Documentation, arranging inspection and getting approval from Electrical Inspectorate including statutory fees (Fees applicable only for the DG set) to KSEB/Electrical Inspectorate.(MR)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C X 10 sq. mm (25mm)
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying bare earthing copper conductor 10 SWG laid 0.6 m below ground level through the existing GI pipe.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply of superior quality copper earth socket for the (4 SWG) earth conductor including crimping etc. as required.
Providing and fixing tinned 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 20 mm dia nominal bore G.I. pipes complete with G.I fittings including trenching and refilling etc. External work
Supply of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminium cable
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 sq.mm in the existing RCC/ HUME/ METAL pipe as required.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
Supply, installation, testing and commissioning of 3 KVA/2.4kW Online UPS Systems (Numeric Onfiniti , 1PH-1PH,FMI ) Floor Mountable Double conversion Pure Online UPS System( 72VDC or above) with built in Isolation Transformer ,Connecting in Standalone Configuration, Input Voltage 160V-280 VAC and output voltage :230V +/-1% , battery using 12 V C10 rated , 6 nos , 100AH Quanta/Exide make Tubular battery, recommended for 120 minutes backup (Minimum VAH 7200) and suitable Battery Rack for housing the batteries. The UPS should have ISO ,BIS,CE .PeP certification & RoHS marking. Warranty: 3 year onsite for UPS & 4 year for Battery
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following modular Switch/Socket on the existing modular plate&swich box including connections but excluding modular plate etc.5/6 A Switch
Supplying and fixing following modular Switch/Socket on the existing modular plate&swich box including connections but excluding modular plate etc.3 pin 5/6 A socket outlet
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supply and installation of Automatic water pump controller for single phase 230 V, 50 Hz ac, 1 hp pump with tank and sump sensors 2 Nos and level threshold indicators. Preferred make: SINICON/V-GUARD or Equivalent
Supplying and drawing 4 x 6.0 sq.mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supply of 3 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper Power cable
Supply of armoured cat 6 cable
Supplying and making end termination nickel plated single compression brass cable gland for 3 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supply and installation of wall mounting cubicle type 254x180x111 mm, TK 2518 - 11 Cape make empty enclosure with transparent lid
Supply and installation of Rocker type MPCB suitable for current range 2.5 - 4 Amps
Supply and installation of 2.5 sqmm Elmex connector
Supply and fixing 22.5 mm dia LED phase indication lamp of red / Green colour for indicating ON/OFF condition of pump and power supply
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supplying and fixing 2/ 6 amps rating, 240/415 volts, "C" curve, single pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 10 amps rating, 240/415 volts, "C" curve, double pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing IP 65 CAPE 24 module( Model No Ak 24) 370x250x122mm Thermoplastic polystyrene MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
Supplying and fixing IP 65, 3 module,100 x 170 x 105, 3902 T Cape make Thermoplastic MCB distribution Board with out PE + N terminals complete with connections,testing and commissioning etc. as required
Providing and fixing ISI marked 50A HRC fuse link in the existing Fuse unit.
Providing and fixing 125A ,230 V Porcelain Fuse unit in the Existing meter box including drilling holes in meter box, making connections, etc. as required.
Hi Range Equipents
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_618817.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .