Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹20.4 L+₹1.3 L (7.01%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹21.6 L+₹2.6 L (13.7%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance NOT L1 |
Tender Value
₹19.3 L
EMD Value
₹38,600
Closing Date
13 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
PROVN OF E/M SANCTION WORKS MW 08,09,10 AND SWR 18 AT INFANTRY LINES JAMNAGAR
2023_MES_580668_1
8953
Open Tender
Electrical and Maintenance Works
Item Wise
180 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE A JAMNAGAR
₹38,600
23 Mar 2023
13 Feb 2023
15 Mar 2023
14 Feb 2023
13 Mar 2023
27 Feb 2023
Amount
PROVN OF THREE PHASE CONNECTION INCLUDING AUTOMATIC METER READING (AMR)/ PREPAID METER AT SHOPPING COMPLEX BACKERY AND CONVERSION OF THREE PHASE LT UG CABLE AND OTHER CERTAIN ALLIED WORKS AT BDE MESS INFENTRY LINES & 152 AD REGT UNDER GE (ARMY) JAMNAGAR(JNR/MW/08/22-23)
Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in soft / loose soil (By manual means) and including laying / taking out of LT UG cable complete all as specified and directed.
Returning, filling in including necessary spreading, leveling , watering and well ramming in layers not exc 25 cm thick in soils complete all as specified and directed..
Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point complete all as specified and directed..
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak of size 250 mm x 150 mm x 40 mm with minimum average breaking load 200 Kg as per IS 5820:1970, ISI marked complete all as specified and directed.
Supply, Spread and filling for clean dry river sand in trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified and directed. Note :- Punned thickness only will be measured and paid.
Supply & lay GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc of following sizes complete all as specified and directed . (a) 50 mm dia bore
(b) 40 mm dia bore
(c) 20 mm dia bore
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of following sizes complete all as specified and directed. (a) 3.5 core x 70 Sqmm
(b) 3.5 core x 50 Sqmm
(c) 4 core x 25 Sqmm
(d) 2 core x 6 Sqmm
Supply, installation, testing & commissioning of Three Phase, 4 Wire, Pre-paid Energy Meters, BIS 15884 with Pre Payment Shock Proof capacitive touch Key pad, communication based Digital having current range 10-100 Amp, 415 V, accuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, (GPRS Type) containing provision for TOD & RTC, (wireless, without DCU, USB, Pen drive & Sim, no other extra equipment required for data, meter itself capable for data storage) capable to define 4 tariff slabs, happy hour & holiday definition, when user go outside of the home, via mobile app user can decrease its sanctioned load complete all as specified and directed. That the manufacturer or their service provider shall furnish 5 (Five) years replacement guarantee for prepaid meters installed under this contract. (Model- Liberty 370) Make ABB, L&T, Schneider, SECURE or Eqv of make specified (i) Meter Should support the following data: 30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand (ii) Meter should have connect / disconnect functionality operable from prepaid billing software (iii) The meter should support open communication protocol DLMS with the software. Note:- (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters would carry 5 year warranty.
Supply and "Commissioning and testing of configuration of multi user web based software with following modules: (i) Meter Data Management Module:- The meter data management software would be responsible for collecting the data concentrator and make the data available to the billing system. The system would support meter data entry. The meter data management system would capture and provide the following:- (ii) Monthly billing survey data for cum energy and max demand (ii) Billing Module:- The billing module would collect the data from the meter management module, calculate billing determinate and make energy data/ billing data available to admin and end users. (iii) Occupation and Vacation Module :- The system would support occupation / vacation based on the unit categories. The system would support data capture on occupation and vacation events. (iv) Customer Portal :- The system would include a customer portal for the resident / occupant to log in and view their own energy / billing data. (v) Energy Accounting Module:- The system would include features of energy accounting the system would be able to account for total energy. (vi) Will provide internet infrastructure at AGE/ BSO office for server having minimum speed of 10-20 MBPS without any extra cost to the department for the period of one years (vii) Contractor/OEM will be fully responsible for server connectivity and also functioning of complete system comprising of server for data base. " Note:- (a) The software would be hosted on MEITY (Ministry of Information Technology) approved GCC (Government Community Cloud) (b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc. (c) Annual vending charging for one year complete all as spcified and as directed
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Tripple pole and neutral (TPN) rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Dismantling of PCC poles of any type or size including necessary demolition of PCC foundation etc and hand over to storeyard of AGE E/M Jamnagar complete all as specified & as directed.
Dismantling of cross arms of MS channels or angle, section etc complete all as specified & as directed
Dismantling of OH ACSR conductor of any size and hand over to storeyard of AGE E/M Jamnagar complete all as specified & as directed.
Dismantling of OH Areal bunch cable conductor of any size and hand over to storeyard of AGE E/M Jamnagar complete all as specified & as directed.
Taking down existing single phase electric energy meter single phase after disconnecting all necessary electrical connections and deposit to store yard of AGE E/M Jamnagar complete all as specified and as directed.
Dismantling of stay assembly complete all as specified & as directed.
M &L for Demolition for Concrete in ground floors/ hard Road standing of 20 cm width & 45 cm depth for laying UG cable/ GI Protection pipe including making good with PCC 1:2:4 type B2 match with existing PCC complete all as specified & directed.
PROVN OF 70 NOS DIFICIENT CEILING FANS TO BLDG NOS NP-35 TO NP-42 AT NP LINES AND POLICE LINES OF 9 MADRAS (TRAVANCORE) UNDER GE (ARMY) JAMNAGAR(JNR/MW/09/22-23) and PROVN OF 86 NOS DIFICIENT CEILING FANS FOR BLDG NO P-385 TO 391, P-393 & P-437 AT DWARKA ENCLAVE AT 13 JAKLI UNDER GE (ARMY) JAMNAGAR( JNR/MW/10/22-23)
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including PVC casing and capping with all accessories such as screws, plastic gutties, etc. fixed to wall/ roofs/ ceiling etc, with mild steel/ pressed sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly painted with two coats of anticorrosive paint over a coat of red oxide metal primer , covered with 3 mm thick ISI marked backelite hylam sheet for fixing the swiches & fan regulators etc with brass screws & brass washers, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for One fan point controlled by one, one way switch 5 Amps and regulator
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for stepped type electronic fan regulator flush type suitable for 100 watts complete all as specified and directed at site.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
S & F GI pipe medium grade 50 mm dia for supprting the ceiling fan including necessary fixing arrangements in between two walls of room with cement work complete all as specified and as directed.
M & L for fabrication of Fan hook made MS Flat of size 50 x 6 mm with 12 mm MS rod bend to required shape fixing to GI pipe with bolt & nuts required suitable size complete all as shown, specified and as directed.
M & L for fabrication of Fan hook made MS Flat of size 50 x 6 mm with 12 mm MS rod bend to required shape fixing to RCC ceiling with provn of 02 Nos hold fashner nuts required suitable size including drilling complete all as shown, specified and as directed.
S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1(5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC) without remote system and electrical connections from ceiling rose fan terminal complete all as specified and as directed. (Make shall be as per Make specified in Cat I and Appx A of PS)
SPECIAL REPAIRES/ REPLACEMENT OF EXISTING UNSV CHLORINE DOSING SYSTEM AND OTHER ALLIED WORKS UNDER GE (ARMY) JAMNAGAR(18/SRW (E/M)/JAM/22-23)
Taking down existing old extg LT UG cable of any description and size from Motor Starter Panel to Centrifugal pump set Motor connector complete all as specified and directed of following sizes:- (a) 3.5 core x 50 Sq mm
(b) 3.5 core x 95 Sq mm
Supply and fix Hot dipped Galvanized CABLOFIL wire mesh cable trays should comply Standard EN ISO 1461, manufactured with a longitudinal 'T- welded' safety edge, constructed with 50 X 100 mm mesh configuration including couplers, covers with clips and wall mounting accessories as per site requirement. Supports, brackets or hangers, covers designed loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537 of following sizes complete all as specified and as directed. (a) 150 mm width x 54 mm height
(b) 200 mm width x 54 mm height
Supply & Laying, testing & commissioning of LT cable PVC sheathed PVC insulated, screened PVC bedded, unarmoured electric power cable heavy duty with stranded copper conductor 1100 volts grade, laid in trenches/ surface of wall including brass cable glands,clamps,etc including removal of existing unsv cable from motor terminal to star delta starter and making good damaged surfaces as required of following sizes complete all as specified :- (a) 3 core x 16 Sqmm (for 60 HP Motor)
(b) 3 core x 35 Sqmm (for 100 HP Motor)
Supply , Testing and install for heavy duty chemical dosing system plunger type suitable to injet solution upto 25 LPH working pressure 10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of capacity 0.50 HP, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweep blade duly FRP coated, FRP tank 150 Ltrs capacity,(incl first fill of chlorination chemical dose) complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete all as specified. Make Sathya Sai Aqua Pura Services Model No SSAPS/CDSPT/25/ST or its equivalent make specified
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe (light grade) and watering pipe 20mm bore GI pipe(light grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc incl taking down old earthing . complete all as specified and directed by Engineer-in-Charge. Note :- GI earthing wire of same size upto 7.5m shall deemed to be included into quoted rate
ABR Trading Co
JAYESH TRADING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .