Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹20.5 L | L1 | Accepted-AOC AOC |
| 2 | L2₹21.5 LRejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹21.5 L | L2 | Rejected-Finance Other then lowest bidder |
| 3 | L3₹24.0 LRejected-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | ₹24.0 L | L3 | Rejected-Finance Other then lowest bidder |
| Sl No | Description | Qty | Unit | Electricals India L2 | M/s SK Traders L1 | BK CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning of indoor type HT vaccum circuit breakers panel of suitable size to match with existing VCB extensible type having 3 Nos out going VCBs to be coupled with existing VCB panel installed at New MRS building, capacity of each VCB 11 KV, Minimum 800 Amp, 3 Phase, 3 wire, 50 Hz, having 26.3 KA breaking capacity, all specified as per IEC 62271-100 & IEC 62271-200 totally enclosed single bus bar for each phase, floor mounting, metal clad, flush fronted, horizonal draw out type, horizontal. isolation type, Indor extensible type, with Elecrtical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assembly of 3 vaccum interrupters, with epoxy support insulations and self- aligning finger type isolating contracts, truck having integral racking with necessary interlocks ( for insertion and withdrawal of VCB), manual and automatic motor charged independent closing/tripping spring, trip free operating mechanism with closing and tripping push buttons and mechanical breaker, all standard fitting and accessories of following :-
(a) Bus bar chamber with 3 phase copper bus bar 1000 Amp rating duly insulated - 01 Set (set of three).
(b) Electrical trip coil 30 V DC / 110V DC-1 No
(c) Electrical shunt coil 30 V DC/110 VDC-01 No
(d) CT Chamber incorporating 3 Nos single phase rasin cast current transformer ratio 200/100/5-5 class 1.0 for metering & class 5P10 for protection and burdon 15 VA, 11 KV, 25 KA for 1 Sec-1 No
(f) Digital ammeter 0 to 200 Amp, (100% of CT ratio) for 3 Phase- 01 No
(g) Digital voltmeter rating 0 to 12 KV, for 3 phase-01 No
(h) Digital Load manager for amps, volts, KW, KVA, KVAR and PF Make : Conserve EM 6400, Secure Ellite 443 or requivelant/ model-01 No as approved by GE. | 1 | Set of 3 | 17,91,000 ₹17.9 L | 16,00,000 ₹16 L | 21,00,000 ₹21 L |
| 1.01(j) Three phase over current and earth fault digital numeric relay (over current (INST 50) & IDMT - 51-3 pole & earth fault (INST (50N) & INST (50N) & IDMT 51N- single pole) & negative sequence 46 auxiliary supply 20-110V AC/DC CT out put Contacts 2 Nos + NC rating-5, O/C Is=20-200% in step of 5% E/F Os=5-80 % in step of 5 %. with common port, the features and specification confirming to model No. MI COM P 122 of AREVA or equivalent Make of ABB-REJ601 or Seimen 7SR10. (k) Auxiliary relay with 6 N/O & 6 N/C Make Alstom/ABB/L&T- 1 No (l) Master trip circuit Make Alstom/ABB/L&T- 1 No (m) TNC switch and LR switch - 1No (n) Heat control switch- 1 No (o) RYB, ON/OFF, spring charged and discharged & VCB trip indications-1 set (p) Space heater weith thermo state & toggle switch - 1 No (q) Operating counter- 1 No (r) Rear and side cable box suitable for 95/120 Sq.mm 3 core XLPE cable (s) Spring charging motor with starter 230V AC-1 No (t) Pluggable anti-pumping relay type CRM 4 with base-1 No (u) Pluggable AC fail relay type CRM 4 with base-1 No (v) Pluggable DC fail reply type CRM 4 with base - 1 No (w) CB contact multifunction relay type PSU14(52X)- 1 No (x) 12W Annunciator + hooter - 1 set (y) Power pack 230V AC-110V DC (z) Control MCB/Fuse set- 1set (aa) Panel illumination lamp with door limit switch - 1set (ab) Push button for TCH-1 No (ac) 9 KV, 10 KA, surge arrestor - 1 set of three (ad) indicating lamp- 1 set | ||||||
| 1.02NOTES:- (i) VCB shall be extensible type. (ii) The contractor shall get the approval of GE for the make of the VCBs they plan to procure. (iii) Prior manufacturing the general arrangement drawing design details of the VCB panel shall be got approved by GE. (iv) Electrical shunt coil 30 V DC/110 VDC-01 No (v) Erections commissioning and civil work (Plinth protection) with PCC/Brick work for installtion of VCB is deemed to be included with unit rate. The plinth protection details as per the manufacturer instruction. (vi) This outgoing VCBs Panel is to be connected to existing VCBs Panel hence cost of busbar which is usung for extention of existing VCB is also included with unit rate of VCBs panel. | ||||||
| 2.00 | Supply & install float cum Boost charger Panel with battery having input voltage 415+ 10% AC 50 Hz and output 110 V, 30 Amp DC auxillary power supply system for protection of panels complete with sealed maintenance free lead acid/VRLA batteries 110 volts (2V x 55 Nos) 100 AH, mounted on and including MS rack and connecting wire connection complete, with installed capacity including 110 V-30A as per DC ammeter, voltmeter, switches for 11 KV system including taking out existing charger complete. | 1 | EACH SET | 2,70,000 ₹2.7 L | 3,50,000 ₹3.5 L | 2,10,000 ₹2.1 L |
| 3.00 | M&L Earthing complete with galvanised steel electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as GI strip of 32x6mm size by means of bolts, nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No 3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation& earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 40mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.
Note :-
(i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra. | 7 | EACH | 7,560 ₹52,920 | 7,000 ₹49,000 | 6,000 ₹42,000 |
| 4.00 | Supply and fixing of 4 core 2.5 sqmm PVC insulated PVC sheathed control cable copper unarmoured complete all as specified and as directed. | 180 | RM | 198 ₹35,640 | 300 ₹54,000 | 260 ₹46,800 |
Updated dates
Tender Value
₹24.3 L
EMD Value
₹48,500
Closing Date
24 Oct 2025, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
SPECIAL REPAIR REPLACEMENT OF UNSERVICEABLE VCBs AT MRS DARJIPURA AT AF STN VADODARA
2025_MES_731969_1
82275/BRD/E8
Open Tender
Electrical and Maintenance Works
180 days
Baroda
As per tender document
7 documents required · 7 mandatory
₹500
GE (AF) Baroda
₹48,500
Yes
22 Dec 2025
20 Sept 2025
3 Nov 2025
20 Sept 2025
24 Oct 2025
10 Oct 2025
20 Sept 2025 - 3 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
tender82275.pdf
Tender Documents • 1.14 MB
BOQ_819512.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid