Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.7 L+₹1,367 (0.21%)Rejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.7 L+₹8,683 (1.31%)Rejected-Finance P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | L3 | Rejected-Finance L3 | |
| 4 | L4₹6.8 L+₹18,711 (2.82%)Rejected-Finance CHANDURIA SIMURALI DIST NADIA PIN 741248 | NADIA | WEST BENGAL | 741248 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹13,971
Closing Date
20 Jun 2025, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Supply Installation Testing and Commissioning of Air Conditioner System in different office chamber at Environment Department, 5th Floor, Pranisampad Bhawan, Salt lake, Kolkata
2025_WBPWD_861044_1
WBPWD/EE/BED/e-NIQ-27/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Pranisampad Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹13,971
16 Jul 2025
12 Jun 2025
23 Jun 2025
13 Jun 2025
20 Jun 2025
13 Jun 2025
Amount
Supply, Installation, Testing and Commissioning of Split type AC machine having Cooling Capacity range (5.2 kw - 5.6 kw) with fixed speed Rotary compressor, Refrigerant gas R32 / R410A, BEE star rating - 3, (ISEER range 3.5 to 3.99), Air flow range CFM (550 - 765 or better), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 139 l ( Part - I & Part - II) with all amendments (Make: Mitsubishi Electric- AGZI8VFi Mitsubishi Heavy-SRICOCXS-W6/ O General- ASGAI 8BMAA-B) (R32) (As per choice of EIC.)
Supply, Installation, Testing and Commissioning of Split type AC machine having Cooling Capacity range (6.8 kw - 7.7 kw) with fixed speed Rotary compressor, Refrigerant gas R32 / R410A, BEE star rating - 3, (ISEER range 3.5 to 3.99), Air flow range CFM (780 - 880 or better), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 139 l ( Part - I & Part - II) with all amendments (Make -Mitsubishi Electric GK24VA/ Mitsubishi Heavy SRK24CW-S6/ O General ASGA24BMWAB (R32)As per choice of E.I.C.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard 85864 or ANSIB 16.22) incl. 19 mm thick insulation.
5/ 8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation.
Supply and laying of 1.1 kV grade copper unarmoured round cable of 3 core 2.5 sq. mm from IDU Unit to ODU Unit for the above mentioned AC Unit. [Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC]
Supply and laying PVC Drain Pipe 25mm dia with 6 mm thick Nitrile Rubber Insulation. [Make:- Suprime/Oriplast]
Supply and Fixing of 12 mm thick 5' x 2' Green gold Plywood for installation of Split AC machine by four nos of fastner on the wall and mending good the damages. (mke-Greenply/ Century Ply/ As directed by EIC).
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. (a) 3.9 meter height
(b) Extra for additional 3.6 height or part there of
S & F 3mtr of 40mm dia UPVC Pipe on wall with saddles and other accessories and mending good the damages to building work as per direction of EIC. (Make-Supreme/Skipper/Florex)
S & F 40mm dia UPVC Elbow as per direction of EIC. (Make-Supreme/Skipper/Florex)
S & F 40mm dia UPVC pipe Tee as per direction of EIC. (Make-Supreme/Skipper/Florex)
S & F 40mm dia UPVC Pipe Coupling as per direction of EIC. (Make-Supreme/Skipper/Florex)
Supplying and fixing double door Horizontal 6 way TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Incomming- 01 no. 63A 415 V Four Pole Isolator of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs, Outgoing-18 nos 6A-32A SP MCB) as to G.S (Make-Legrand/ABB/Siemens)
Supply of OLP-3, 25A is a highly advanced microprocessor controlled starter used for ACs and other compressor loads. The time-tested combination of Voltcheck, Ampcheck & Timecheck ensures safe operation and long life of AC Compressors. [Make: Electron/Ultratech/Ultrasafe] OLP-3, 25A Starter.
Supplying & Fixing GI Modular Switch Board of the following sizes incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 4 module GI modular box for housing the OLP starter.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
S & F Timer Control unit for 1 Ph AC machines with 12-way SPN DB Box(Mk.- L & T /Crabtree/ kgrand/Siemens/ABB) 12 way SPN DB or Timer DB- 1 no 40A DP MCB Isolator-l no Digita 24 hrs.Time switch- I no 32A 2-pole power contactor-1no Centre off 2-way toggle switch-l no 32A Barrier type Terminal -l no LED indicating lamp-l no 2x4+1x2.5 Sq.mm Cu wire(Gloster /KELR.R Kabel) as per choice of EIC.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 40 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required of 4x16sqmm+2x10 sqmm ECC (from VTPN to HTPN) ( make: Gloster/ Polycab/Havells/as per direction of EIC).
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' as to GS. A) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 2.5 sqmm
b) 4.0 sqmm
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
ANIKET COOLING AND REFRIGERATION CO (BID ID -6594637)
BARSHA ENTERPRISE (BID ID -6605408)
ROY REFRIGERATION (BID ID -6607466)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .