| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC POST MISAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹38.9 L+₹5.1 L (14.9%)Rejected-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
7 Aug 2023, 6:00 pmClosed
GE MISAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIRS TO INTERNAL WIRING INCLUDING FITTINGS /FIXTURES TO JCO AND ORS MD ACCN UNDER GE MISSAMARI
2023_MES_606446_1
8393
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MISAMARI
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
GE MISAMARI
₹84,000
Yes
5 Oct 2023
1 Jul 2023
10 Aug 2023
1 Jul 2023
7 Aug 2023
14 Jul 2023
Amount
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed.
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including Rigid PVC Concealed Conduit, medium grade, ISI marked of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22 mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light/Fan/Call bell Point controlled by One 1-Way Switch 5 Amp, duly fixed with copper lugs and flexible pipe from ceiling rose to fitting/fixtures complete all as specified and as directed.
Description all as per item No 4 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and directed
Description all as per item No 4 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed.
Description all as per item No 4 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed
Description all as per item No 4 here in before but for one light point controlled by one, two way switch 5 Amps complete all as specified and directed.
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed. Make : KEI/Polycab/Havells
M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light/Fan/Bell Point controlled by One 1-Way Switch 5 Amp, duly fixed with copper lugs and flexible pipe from ceiling rose to fitting fixtures complete all as specified and as directed.
Description all as per item No 10 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.Make : KEI/Polycab/Havells
Description all as per item No 10 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed .Make : KEI/Polycab/Havells
Description all as per item No 10 here in before but for one light point controlled by one, two way switch 5 Amps complete all as specified and as directed.Make : KEI/Polycab/Havells
Description all as per item No 10 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed.
M & L Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor duly cutting chases on walls and drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 6.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs and making good disturbed surfaces and matching with existing colour complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor duly cutting chases on walls and drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 4.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs and making good disturbed surfaces and matching with existing colour complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Casing Caping ISI marked and its accessories including one run of single core 6.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Casing Caping ISI marked and its accessories including one run of single core 4.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs complete all as specified and directed.
S & F in replacement switch piano (white) single pole flush type 5 amps, 230 volts.complete all as specified and directed.
Fixing only switch piano single pole flush type 5 amps, 230 volts obtained from item No 1 above complete all as specified and directed.
S & F in replacement switch piano (white) single pole flush type, two way, 5 amps, 230 volts.complete all as specified and directed.
S & F in replacement bell (white) push flush type 5 amps, 230 volts.complete all as specified and directed.
S & F in replacement socket (white) flush type multipurpose 3/5 pin 5 amps 2 in 1, 230 Volts all as specified.
Fixing only socket flush type multipurpose 2/3 pin 5 amps 2 in 1, 230 Volts obtained from item No 1 above complete all as specified and directed.
S & F in replacement switch socket combination (white) flush type multipurpose 3/5 pin 5 amps 2 in 1 230 Volts complete all as specified and directed.
Fixing only switch socket combination flush type multipurpose 3/5 pin 5 amps 2 in 1 230 Volts obtained from item No 1 above complete all as specified and directed.
S & F in replacement switch socket combination (white) 2 in 1 multipurpose 3/5 pin 5/15 amps flush type complete all as specified and directed.
S & F in replacement Switch (white)15 amps flush type complete all as specified and directed.
S & F in replacement Socket (white) 15 amps flush type complete all as specified and directed.
Fixing only switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type obtained from item No 1 above complete all as specified and directed.
S & F in replacement ceiling rose (white) three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed.
Fixing only ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm obtained from item No 1 above complete all as specified and directed.
S & F in replacement ceiling fan regulator (white) step type 2 module , flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified and directed.
Fixing only ceiling fan regulator step type, flush type heavy duty suitable to work on 230 volts Ac supply obtained from item No 1 above complete all as specified and directed.
S & F in replacement lamp holder (white) insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round/squareblockscomplete all as specified and directed.
Fixing only lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round/square blocks obtained from item No 1 above complete all as specified and directed.
S & F call bell suitable to work on 230 volts Ac supply including removal of old unsv call bell complete all as specified and directed.
S & F in replacement LED ADORE 10 W B22 CDL 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified and directed.Make Havells, Cat No: LHLDEUEBML8Z010 or equivalent in Crompton or Bajaj
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with locking system complete including removal of old unsv sheet metal enclosure grouted on walls complete all as specified and directed. Make -L&T/Schneider/ Seimens /Legrand
S & F sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with locking system complete including removal of old unsv sheet metal enclosure grouted on walls complete all as specified and directed. Make -L&T/Schneider/ Seimens/Legrand
S & F sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete including removal of old unsv sheet metal enclosure complete all as specified and directed. Model:-DBTPE004DD Make -L&T/Schneider/Seimens/Legrand
S & F MCB TPN 415 volts suitable for fixing in MCB DB of capacity 63 amps complete all as specified and directed. Make -L&T/Schneider/Seimens/Legrand
S & F MCB SPN 230 volts suitable for fixing on MCB DB of capacity 40 Amps complete all as specified and directed.Model:-Make -L&T/Schneider/Seimens/Legrand
S & F MCB SP 6 to 32 Amps C-Series 240 volts for fixing on MCB DB's complete all as specified and directed. Make -L&T/Schneider/Seimens/Legrand
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative ultra slim round profile LED lighting fixture with extruded polycarbonate , environmental friendly energy efficiebt ready to use pack with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make :- Model No. LHEXAPP7UN1W020 of Havells or Equivalent in Surya / Crompton / Philips
S & F in replacement Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 20 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape duly fixed with Clamps nuts and bolts complete all as directed by Engineer-in-Charge. Make- Havells Cat Part No. LHEXAYP7PN6K020 or equivalent in /CG/Surya / Philips
S & F wall mounted LED 09 watts, box type light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements and connection from ceiling rose to fitting for LED tube 2 Foot 09 watts complete including dismantling the existing unserviceable fitting, complete all as specified and as directed. Model No. LHEXBLP7IN1W009 of Havells or Equivalent in Crompton / Philips/ Surya
S&F in replacement decorative, wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base made out of polycarbonate with unbreakable globe/frame suitable for LED bulb and provision of LED bulb 09 watts complete incl removal of old unsv fitting all as specified and as directed. Model No. LHFOECE1TZ1O014 of Havells or Equivalent in Crompton /Philps / Surya
S & F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete incl removal of old unsv fitting all as directed by Engineer-in-Charge. Model No. LBHP-10-CDL of crompton or Equivalent in Havells / Philips/ Surya
S & F ceiling fan capacitor 2.25 mfd as per site requirement including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
S & F ceiling fan capacitor 2.5 mfd as per site requirement including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
S & F ceiling fan capacitor 3.15 mfd as per site requirement including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
S & F ceiling fan capacitor 4.0 mfd as per site requirement including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
S & F ceiling fan capacitor 6.0 mfd as per site requirement including removal old existing unsv one complete all as specified and directed. Make Havells/Universal/Sarda/Epcos
Taking down the existing unservicable UG cable of any type/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. Note : Earthwork will be measured and paid seperately.
Relaying Serviceable LT UG XLPE cable of size 2/3.5 core x 16/25 sq mm obtained from item no. 55 laid in trenches/ floors/ on wall/ service connections after cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCB with necessary lugs after cutting to required length of cable complete all as specified and directed
Relaying Serviceable LT UG XLPE cable of size 3.5 core x 16/25 sq mm obtained from item no. 55 laid in trenches/ floors/ on wall/ service connections after cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCB with necessary lugs after cutting to required length of cable all as specified and directed.
Supply & laying incl replacement of LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 35 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No.58 here-in-above, but 25 Sqmm x 3.5 Core, Complete all as specified and as directed.
All as per Item No.58 here-in-above, but 16 Sqmm x 2 Core, Complete all as specified and as directed.
Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in soft / loose soil for laying /taking out of LT UG cable complete all as specified and directed.
Returning, filling in incl spreading, leveling , watering and well ramming in layers not exc 25 cm thick in soils complete all as specified and directed.
Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and laying well burnt Bricks , locally available best quality (sub class "B" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified and directed.
Supply , spread and filling approved sand in cable trenches for cushioning of LT UG cable complete all as specified and directed. NOTE :- Punned thickness only will be measured and paid.
Supply & lay GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc of size 40 mm dia bore complete all as specified and directed .
S & F PVC Square Box of Size 4'' x 4'' including replacement of old UNSV one and refixing of old switch sockets as per existing at site complete all as specified and directed. Make Presto plast / Harsh /Plaza / AKG
S & F PVC Square Box of Size 7'' x 4'' including replacement of old UNSV one and refixing of old switch sockets as per existing at sitecomplete all as specified and directed. Make Presto plast / Harsh /Plaza / AKG
S & F PVC Square Box of Size 8'' x 6'' including replacement of old UNSV one and refixing of old switch sockets as per existing at site complete all as specified and directed. Make Presto plast / Harsh /Plaza / AKG
S & F PVC Square Box of Size 12'' x 10'' including replacement of old UNSV one and refixing of old switch sockets as per existing at site complete all as specified and directed. Make Presto plast / Harsh /Plaza / AKG
Supply only PVC wide25mm Insulation Tape of length 25 meter complete all as specified and directed. Make Anchor Grip / MS-seal / Havells
Supply and Fix for PVC casing and capping in repairs duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as specified and direced. Make Presto Plast / Plaza / AKG / Harsh
Supply and Fix for PVC Conduit in repairs duly fixed with Clamps on wall surfaces and connecting accessories like Tee , Bends , elbow etc required as per site complete all as specified and direced. Make Presto plast / Harsh /Plaza / AKG
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and direced. NOTES : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level.
Refixing of point wiring obtained from item no.1 with existing 1.5 sqmm PVC insulated stranded copper conductor single core complete with all accessories and all as specified including 1.5 Sqmm insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dolly for fan / light / exhaust fan/ bell point controlled by one switch by using casing capping complete all as specified and directed .
All as Per Item No.75 but for One 3 pin socket outlet, 5 Amp independent
All as per item no.75 but for One 3 pin socket outlet, 5 Amp on the same board with other switches
Description all as per item No 75 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm multi stranded copper conductor as continuous earth wire with lugs by using casing Capping complete all as specified and directed.
Refixing Sheet metal enclosure for MCB DB double door single pole & Neutral 4/6/8 /12 way with common bus bar obtained from item no. 2 as per existing at site or other location complete all as specified and directed .
Refixing Sheet metal enclosure for MCB DB double door VTP /TPN 4/8/12 way obtained from item no. 2 as per existing at site or other location complete all as specified and directed
Taking down and refixing MCB four pole , 63 Amps with breaking capacity 10kA,
Taking down and refixing MCB 'B' curve single pole neutral , 32 Amps with breaking capacity 10kA,
Taking down and refixing MCB 'B' series single pole 6 to 32 Amps, breaking capacity 10KA.
Taking down and refixingEarth plug & Socket with MCB 25 Amps capacity AC 230 Volt with MCB and Plug Top complete all as specified and directed.
Taking down and refixing only submain wiring two single core 6.0 sqmm size stranded copper conductor PVC insulated unsheathed cable in existing PVC Casing Capping and one PVC cable 6.0 sqmm size copper conductor PVC insulated and unsheathed for contineous earth wire and other accessories complete all as specified and directed.
All as per Srl. Item No. 85 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor.
Taking down and refixing LED luminaire18/20/ 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp / 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cablesuitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Taking down and refixing ceiling fans complete with blades, down rods r and accessories, 230 V, any sweep complete all as specified and directed.
Taking down and refixing exhaust fan,single Phase. 230V of any sweep with, blades, and frame and louvers for repair including making hole as per site including making good disturbed surfaces fixing with fastnuts , properly clamped louvers complete all as specified and directed.
Supply and Fix in replacement of Copper wire 1.0 Sqmm 2 Core complete all as specified and directed.
Supply and Fix in replacement of Copper wire 1.5 Sqmm 3 Core complete all as specified and directed.
Supply and Fix in replacement of Copper wire 2.5 Sqmm 3 Core complete all as specified and directed.
M & L Submain wiring with 2 runs of single core1.5 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor duly cutting chases on walls and drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 1.5 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs and making good disturbed surfaces and matching with existing colour complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor duly cutting chases on walls and drawn through and including non-metalic Rigid PVC Conduit ISI marked and its accessories including one run of single core 2.5 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs and making good disturbed surfaces and matching with existing colour complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 1.5 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Casing Caping ISI marked and its accessories including one run of single core 1.5sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metalic Rigid PVC Casing Caping ISI marked and its accessories including one run of single core 2.5 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs complete all as specified and directed.
Supply and Fix Cable end termination kit for LT 1.1 KV Cable for Cable 25 to 50 Sqmm 3.5 Core cable complete all as specified and directed .
M/S RANA ENGINEERING ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .