Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.2 L+₹3.0 L (26.8%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 | |
| 3 | L3₹18.5 L+₹7.3 L (65.0%)Rejected-Finance 2 A 31 CHOPASANI HOUSING BOARD JODHPUR RAJASTHAN 342008 | JODHPUR | RAJASTHAN | 342008 | L3 | Rejected-Finance REJECTED DUE TO L3 | |
| 4 | L4₹19.1 L+₹7.9 L (70.1%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L4 | Rejected-Finance REJECTED DUE TO L4 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
5 Oct 2020, 5:00 pmClosed
GE SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
REPAIR OF MAINT OF DBS, LT PANELS, SUBMAIN WIRING AND SOLAR WATER HEATER ETC AT MD OFFICERS, JCOS , ORS ACCN AND OTM ACCN UNDER GE SHIKARGARH IN ARMY AREA JODHPUR
2020_MES_376622_1
8645/E8 56
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SHIKARGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE SHIKARGARH
₹40,000
Yes
11 Nov 2020
11 Sept 2020
6 Oct 2020
11 Sept 2020
5 Oct 2020
17 Sept 2020
11 Sept 2020 - 16 Sept 2020
Amount
M&L for load balancing of three phase DB of building of any type/size and capacity complete including dis-connecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium /Copper Thimbles of any size and capacity all as specified and as directed by Engr-in-charge. Note : (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, earth and neutral link, insulator, any type of screws, copper/aluminium bus bar of any size as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCCB/MCB required for replacement shall be measured and paid separately in relevant item.
M&L for load balancing of single phase DB of qtr/bldg of any type/size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium /Copper Thimbles of any size and capacity all as specified and as directed by Engr-in-charge. Note : (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, earth and neutral link, insulator, any type of screws, copper/aluminium bus bar of any size as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCB required for replacement shall be measured and paid separately in relevant item.
Repair of indoor type LT panel board mounted on bldg wall of size aprox 1.2X0.90X0.25 mtrs and replacement of unserviceable switch/control gears and 2 way connector,indicator lamps, threaded panel door lock etc including rewiring and extension of incoming and out going cables by opening of loops/making joints with same size cable and provisioning of cable lugs /thimbles as reqd including replacement of rusted sheet metal with existing size MS sheets by necessary arc/gas welding / making cover as per suitable (Approx sheet 0.2 to 0.7 Sqmtrs ) and removing all dirt, dust etc with the help of air blower and load balancing of three phase panel complete & painting complete Panel board including connected accessories with two coats of synthetic enamel spray painting out side surfaces of Panel Board of approved colour including writing of identification etc all as specified and directed by Engineer-in-Charge compriseing the following :- (a) MCCB 100 A, 3 pole 25 KA, 415 Volt -01 Nos (b) Indicator Lamp RYB LED type with fuse.-01 set (c) Coper/aluminium bus bar RYB & N of 200 A size -01 set (d) 1 phase Energy Meter- 06 to 12 Nos (e) MCB SPN/SP mounting on bus bar -06 to 12 Nos (f) threaded door lock - 10 to 16 Nos (g) Arclic PVC sheet for Energy meter -06 to 07 Nos Note : (i) Necessary eqpt and safety measures, stasonary reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, earth and neutral link, insulator, hylem sheet, any type of screws,door locks any type as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCCB, MCB,copper/aluminium bus bar, indicator lamp, PVC arclic sheet required for relacement shall be measured and paid serately in relevent item.
Dismantling of old existing panel board incl disconnecting of main feeder, sub feeders, bus bars, energy meters & removing from site.
M&L for checking of earth resistance test of bldg connected with panel / distribution box by disconnecting of earth strip/ wire with the help of earth resistance tester complete and maintained records in register as per sample given all as specified and as directed by Engr-in-Charge. Note (i) Necessary eqpt , safety measures and stationary reqd for earth resistance test arranged by the contractor without any extra cost.
M&L for checking of insulation resistance test of building wiring circuit wise of each distribution box single phase or three phase and maintain the records in register as per sample given and as directed by Engr-in-Charge. Note (i) Necessary eqpt , safety measures and stationary reqd for insulation resistance test arranged by the contractor without any extra cost.
M&L in replacement MCCB 100 Amps, 3 pole,25 KA,415 Volts Make : Legrand/L&T/Schnider/ABB
M&L in replacement MCCB 80 Amps, 3 pole,415 Volts Make : equivalent in Legrand/L&T/Schnider/ABB
M&L in replacement LED Type indicating Lamp for indication of RYB-01 Set Make L&T, Havells/ Standard.
M&L in replacement copper bus bar rating 200 Amps 25/3mm including making whole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed by Engr-in-Charge,
M&L in replacement aluminium bus bar rating 200 Amps 25X6 mm including making whole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed by Engr-in-Charge,
M&L in replacement Arclic PVC sheet minimum 2 mm thick with fixing arrangement in Panel box suitable for Meters fitted in panel complete all as specified and as directed by Engr-in-Charge,
M & L for preparation of old painted surface of Feeder Pillar box conopy of plant by removing all dirt, dust, etc and painting complete surface including connected accessories with two coat of synthetic enamel paint of approved colour including writing of identification etc all as directed by Engineer-in-Charge
Taking down MCB DB/cut out/main switch including MCBs of any size
S&F sheet metal enclosure for MCB's (D.B) 4 way (SPN), double door, 200 Amps rated bus bar complete Make Legrand / Scheinder/ABB/L&T
S&F sheet metal enclosure for MCB's (D.B) 6 way (SPN) double door, 200 Amps rated bus bar complete Make Legrand / Scheinder/ABB/L&T
S&F sheet metal enclosure for MCB's (D.B) 8 way (SPN) double door, 200 Amps rated bus bar complete Make Legrand / Scheinder/ABB/L&T
S&F sheet metal enclosure for MCB's (D.B) 12 way (SPN) double door, 200 Amps rated bus bar complete Make Legrand / Scheinder/ABB/L&T
S&F sheet metal enclosure triple pole and neutral 415 Volts 4 way (TPN) Double door.Make Legrand / Scheinder.
S&F sheet metal enclosure triple pole and neutral MCCB INCOMER vertical Load line 415 Volts 4 way (VTPN) Double door ith 125 A, 4 pole 415 V MCCB complete. Make Legrand / Scheinder/L&T/ABB.
S&F MCB 240 volts SPN 32- 40 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed by Engr-in-charge. Make Legrand / Scheinder/L&T/ABB..
S&F MCB 240 volts SP 6- 32 amp 10KA breaking , capacity, ISI marked, Make Legrand / Scheinder/L&T/ABB.
S&F MCB 415volts TPN 63 amp 10KA breaking, capacity, ISI marked.Make Legrand / Scheinder/L&T/ABB.
S&F Isolator 415 volts 4 pole 80 amp 10KA breaking, capacity, ISI marked, Make Legrand / Scheinder/L&T/ABB.
S&F Isolator 415 volts 4 pole 100 amp 10KA breaking, capacity, ISI marked, Make Legrand / Scheinder/L&T/ABB.
S&F MCCB 63 Amps 3 pole 415 Volts 25 KA breaking capacity Make Legrand / Scheinder/L&T/ABB.
S&F Blanking plates suitable for MCB DB's. Make Legrand / Scheinder/L&T/ABB.
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified Make Legrand / Scheinder/L&T/ABB.
M&L in replacement of sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including concealed suitable in old MS/PVC conduit with two runs of 2.5 Sqmm and one run of 2.5 Sqmm FR copper conductor as earth wire and connected to earth are runf dolly including taking down old one complete all as specified and as directed by Engr-in-Charge. Note 01: The quoted rates shall be deemed to include cutting of Chasses and making good the disturbed surfaces 02 : Two runs of 2.5 Sqmm submain and one run of earth wire and conduit shall be measured as one unit. Make of wire : Finolex/Havells/KEI/Polycab/V-GAURD. Make of PVC Conduit :Finolex/Modi/Polycab.
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable in old MS/PVC conduit with two runs of 4.0 Sqmm and 4.0 Sqmm FR copper conductor as earth wire and connected to earth dolly including taking down old one complete all as specified and as directed by Engr-in-Charge. Note : No 01: The quoted rates shall be deemed to include cutting of Chasis and making good the disturbed surfaces as per existing. No 02: Two runs of 4.0 Sqmm submain and one run of earth wire and conduit shall be measurable one unit. Make of wire : Finolex/Havells/KEI/Polycab/V-GAURD. Make of PVC Conduit :Finolex/Modi/Polycab.
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable in old MS/PVC conduit with two runs of 6.0 Sqmm and 6.0 Sqmm FR copper conductor as earth wire and connected to earth dolly including taking down old one complete all as specified and as directed by Engr-in-Charge. Note 01: The quoted rates shall be deemed to include cutting of Chases and making good the disturbed surfaces. No 02 : Two runs of 6.0 Sqmm submain and one run of earth wire and conduit shall be measurable one unit. Make of wire :Make of wire : Finolex/Havells/KEI/Polycab/V-GAURD. Make of PVC Conduit :Finolex/Modi/Polycab.
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable in old MS/PVC conduit with two runs of 10.0 Sqmm and 10.0 Sqmm FR copper conductor as earth wire and connected to earth dolly including taking down old one complete all as specified and as directed by Engr-in-Charge. Note 01: The quoted rates shall be deemed to include cutting of Chases and making good the disturbed surfaces. 02 : Two runs of 10.0 Sqmm submain and one run of earth wire and conduit shall be measurable one unit. Make of wire : Finolex/Havells/KEI/Polycab/V-GAURD. Make of PVC Conduit :Finolex/Modi/Polycab.
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable in old MS/PVC conduit with 3 runs of 10.0 Sqmm and 1 run of 10.0 Sqmm FR copper conductor as earth wire and connected to earth dolly including taking down old one complete all as specified and as directed by Engr-in-Charge. Note : 01 The quoted rates shall be deemed to include cutting of Chases and making good the disturbed surfaces. 02 : Three runs of 10.0 Sqmm submain and one run of earth wire and conduit shall be measurable one unit. Make of wire : Finolex/Havells/KEI/Polycab/V-GAURD. Make of PVC Conduit :Finolex/Modi/Polycab.
Earthing complete with galvanised steel earth plate 600 x 600 x 6mm thick buired directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground level connected to galvanised iron lead wire 4 mm dia by means GI welding after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 15 mm dia light grade and providing masonry enclosure and watering pipe of dia 20 mm including wire mesh steel funnel, including watering arrangement 200 ltrs for each earth pit complete as specified and shown on electrical plate No 5 of SSR Part I directed by Engr-in-charge. Make of GI Pipe is Prakash/Jindal/TATA
Earthing complete with galvanised steel earth plate 600 x 600 x 6mm thick buired directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground level connected to galvanised iron strip 25x4mm by means GI welding after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 40mm dia light grade and providing masonry enclosure and watering pipe of dia 40mm including wire mesh steel funnel, including watering arrangement for each earth pit complete as specified and shown on electrical plate No 5 of SSR Part I. Make of GI Pipe is Prakash/Jindal (Note : GI strip 7.5 mtr included in the quoted rate from earth pit to test point)
M&L in replacement Metal clud DP Plug Assembly AC, 220 V, 50Hz, suitable for MCB of capacity 20A, with 2 Pin and one earth pin as per existing Make- Legrend or equivalent in/ Havells/MDS/L&T.
M&L in replacement Metal Clad DP Socket Assembly AC, 220 V, 50Hz, suitable for MCB of capacity 20A, with 2 Pin and one earth pin as per existing Make- Legrend or equivalent in/ Havells/MDS/L&T.
M&L in replacement GI strip 25x4 mm size in earth/floor/wall/in pipe etc complete all as specified and as directed.
M&L in replacement GI wire 4.0 mm size in earth/floor/wall/in pipe etc complete all as specified and as directed.
Taking down/disconnecting 300 LPD Solar water heater for repair /maintenance including service of solar Water Heater and De-scalling of Solar Water heating tank and pipe lines by re-circulating descaling solution with pumps suitable for 300 LPD solar water heating plant including replacement of minor parts such as nuts,bolts,washers etc complete all as specified and as directed installed at roof top of bldgs upto 02 to 04 story and refixing & testing and commissioning after repair complete Note : Any unsv parts reqd for replacement shall be measured and paid separately under respective item of Schedule as supply only.
Supply only flat plate collector with toughened glass suitable for 300 LPD solar water heating plant complete all as specified and as directed Make:Su-Solartech Sstem (P) Ltd/Electrothermal Solar Ltd/Tata BP.
Supply only glazing gasket suitable for flat plate collector toughened glass 300 LPD solar water heating plant complete all as specified and as directed .
Supply only solar flat plate collector toughened glass suitable for 300 LPD solar water heating plant complete all as specified and as directed .
Supply only flange with nipple suitable for 300 LPD solar water heating plant complete all as specified and as directed . Make:Su-Solartech Sstem (P) Ltd/Electrothermal Solar Ltd/Tata BP.
Supply only electrical backup controller 2/3 KW suitable for solar plant of capacity 300 LPD Make:Su-Solartech Sstem (P) Ltd/Electrothermal Solar Ltd/Tata BP.
Supply only flange gasket with nut & bolt complete suitable for 300 LPD solar water heating plant complete all as specified and as directed .
Supply only Temperature gauge suitable for solar plant of capacity 300 LPD Make:Su-Solartech Sstem (P) Ltd/Electrothermal Solar Ltd/Tata BP.
Supply only hose pipe 25 mm dia , pressure 12 kg/sqcm with 02 Nos jubli clamps suitable for connecting inlet and outlet of 300 LPD solar water heating plant complete all as specified and as directed . Make: Gates Greenline or equivalent ISI Marked.
Supply only storage tank SS 304 / SS 316 PUF of capacity 100 litres insulated suitable for 300 LPD solar water heating plant complete all as specified and as directed . Make:Su-Solartech Sstem (P) Ltd/Electrothermal Solar Ltd/Tata BP.
Cleaning of flat collector toughened glass set of 3 of solar heating system by using water with pressure pump & coline suitable for 300 LPD solar water heating plant complete all as specified and as directed .
Supply only Heating Element of capacity 3KW,AC, 230/415 V Cat No- IWI30++ Make-Daspass/ Theeta/ Usha.
Supply only Thermostate suitable for 0 -100 degree, AC, 230V, single phase, 50 Hz cat no- TIH 20 Make-Daspass/ Theeta/ Usha.
S&F, 25mm dia GI tubing medium grade with all fittings fixed, to walls, ceiling or laid in floors, complete all as specified and directed by Engr-in-Charge. Make : Make: Prakash/Jindal/Tata.
S&F, 20mm dia GI tubing medium grade with all fittings fixed, to walls, ceiling or laid in floors, complete all as specified and directed by Engr-in-Charge. Make : Make: Prakash/Jindal/Tata.
S&F, 15mm dia GI tubing medium grade with all fittings fixed, to walls, ceiling or laid in floors, complete all as specified and directed by Engr-in-Charge. Make : Make: Prakash/Jindal/Tata.
S&F Gun-metal, globe or gate valves 25 mm, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed by Engr-in-Charge. Make : Sant/Bir/Leader/Kirloskar.
S&F Gun-metal, globe or gate valves 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed by Engr-in-Charge. Make : Sant/Bir/Leader/Kirloskar.
S&F Gun-metal, globe or gate valves 15 mm, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed by Engr-in-Charge. Make : Sant/Bir/Leader/Kirloskar.
S&F PVC Tank cover suitable for 500 ltr tank as per existing sample complete all as specified and as directed by Engr-in-Charge.
Cleaning and removing all scale and dirt, etc, from PVC tanks 500 ltr and from mouths of circulating pipes, etc.complete all as specified and as directed by Engr-in-Charge.
S & F for Angle stop valve 15 mm of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) Make Paryag/Polytuff/Shakti.
S&F in repair 500 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position including 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe all as specified in SSR Part-I complete all as specified.
Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 with 0.01mm aluminium foil complete suitable for GI pipe size 15/20 mm dia .
M/s R K Enterprises
Axxon Tech Industries
M/s Shiv Builder and Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .