| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 CrAccepted-AOC | ₹14.9 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹15.8 CrRejected-Finance | ₹15.8 Cr | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹16.3 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹16.3 Cr | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹16.4 CrRejected-Finance | ₹16.4 Cr | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹16.7 CrRejected-Finance | ₹16.7 Cr | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹10.1 L
Closing Date
31 May 2021, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone Jodhpur
PROVISION OF SASF AT JODHPUR MILITARY STATION (PHASE-I OF TWO PHASES)(JOB NO S/2963)
2020_MES_400656_1
800512/BNR/2020-21/E8
Open Tender
Civil Works
750 days
Banar
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
GE Banar
₹10.1 L
Yes
Jodhpur
2 Sept 2021
4 Dec 2020
2 Jun 2021
4 Dec 2020
31 May 2021
24 May 2021
14 Dec 2020
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 27(R)(R)(R)
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 29(R)
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 30(R)
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 32(R)
Lump sum price worked out by the contractor for "ROAD, PATH & CULVERT" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 34(R)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 36(R)
Lump sum price worked out by the contractor for "SECURITY FENCING AND GATE" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 39(R)
Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 40(R)
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 41(R)
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 45(R)
Lump sum price worked out by the contractor for "LIGHTING PROTECTION" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No 47(R)
Sch 'A' Sec-XII (MISCELLANEOUS ITEMS) Notes:- (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation & earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
ROAD, PATH & CULVERT M&L for construction of 200mm thick (Compacted thickness) granular sub base by providing close graded material conforming to specificatios, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lits, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power rolled to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. GSB work will be carried out with material conforming to Grade-I (size range 75mm to 0.075mm) having CBR value-30 complete all as specified and directed.
M&L for Polythene film, black, 200 micron laid in floors (under PQC) complete all as specified and directed.
SEWAGE DISPOSAL Construction of septic tank designed to carry sewage and sludge water, including excavation and earth work in any type of soil, disposal of surplus soils to a distance n.exc 50m, PCC 1:4:8 type D-2 using 40mm graded stone aggregate below foundation, Vent shaft, connection etc complete for 10 to 30 Users complete all as as per drawing No CEJZ/TD/30 sheet No 1/3 to 3/3
Construction of Soakage well, excavation, in any type of soil, foundation in PCC 1:3:6 type C-2 using 40mm graded stone aggregate , walls of honey combed masonry with top ring of 25mm concrete,RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC filled with brick bats of size 1.20m internal dia X 3.00 m effective depth complete all as per drawing No. CEJZ/TD/29 sheet 1/3 to 3/3.
FLAME PROOF LIGHT M &L for point wiring using approved colour coading as per IS (Red, Black and Green ) suitable for flame proof (FLP) cross for zone 192 gas group 11 A and 11 B with 2.5 sqmm nominal cross sectional area, multi standard flame retrdant low smoke (FRLS) insulated unsheathed copper conductor cable 1100 V grade IS 694 marked TAC and FIA approved in and including surface mounted with saddles rawl plug and fixing screw etc flame proof metalic conduit pipe heavy duty ISI marked as per IS :9537 (Pt-I) 1980 of suitable size with all flame proof conduit accessories such as bends, elbows, elbows tees etc certified by CMRI Dhanbad as suitable for flame proof areas and sealed with teflon tape on all conduits accessories and also sectional area multi standard flame retarant low smoke (FRLS) insulated , unsheathed coppper conductor cable of size 2.5 sqmm, 1100 V grade IS 694 marked TAC and FIA approved as earth continiuty conductor connected to common earth all as specified. (a) Three lights will be connected through one circuit and controlled by one No of MCB at Main DB box.
M&L for CMRI certified LED based flame proof highbay welglass lumanaries of capacity 40 W, diecast aluminium housing having safety class IP 65 with and including connected to terminal with 3 core 1 sqmm sheathed copper cable and flexible metalic conduit weather proof, internal dia (18 +/- 2) mm , length 300/450 mm and connecting fitting such as reducers, locking nuts, socket etc including weather and dust proof junction box of size 88X88X53 mm, made out polycarbonate , DIN rail removable connector 15 Amp rating, side entries, top screw type outlet arrangement for fixing metalic conduit complete and hanging arrangement etc complete all as specified and directed by Engr-in- charge.
S&F flame proof DB 8 way with CMRI certified with provn and including following switch gear Incoming (a) Flame proof rotary switch with MCB SPN 32 Amps, 10 KA, 01 Nos. Outgoing :- Flame proof rotary switch with MCB 10 Amp SP with 10 KA - 5 Nos
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of protection pipe galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTES FOR ITEM NO 20.00 :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
EXTERNAL WATER SUPPLY Supply, laying, connecting, jointing and testing of ductile iron (DI) pipe class K-7, 100 mm dia laid in trenches with any length, suitable for tyton / rubber joint complete all as specified and directed.
Supplying fixing and testing of ductile iron pipe fittings S/S, and flanged (Special) suitable for tyton joints heavy duty for spigot and socketed DI pipes such as bends (any type radius and angle) tapers, any type Straight bend, increasing, decreasing, decreasing, or double socked etc) Tee pieces, ring branch, Y junction, double branch, Cross (all socket or socket and spigot) collers, caps and plugs, adopters etc or any size radius and length confirming to IS specificatios up to 150mm bore complete all as specified and directed.
Cutting existing DI/CI pipe line for fixing of TEE/Bend etc of pipe size 100/150 mm dia complete all as specified and directed.
Trial bore of 250 mm dia up to 200 mtr depth below ground level in any kind of soil strata including hard stone/ boulder complete all as specified and directed.
M & L for development of trial bore by reaming up to 525 mm for 60m to 200m from ground level and pea gravel level in any kind of soil strata including hard stone/ boulder etc complete all as specified and directed.
M&L for insertion of MS Casing pipe 250mm dia and wall thickness 5.15mm up to the depth of bore well hard rock portion and all as specified and directed.
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water complete all as specified and directed.
Supply, install, testing and commisioning of 7.5 HP Submersible pump, electric driven 415V TP suitable for 250 mm dia bore well (Casing pipe size 250 mm) complete all as specified and directed.
Supply & lay Electric power cables submersible (heavy duty) 1100 Volts grade with stranded Copper conductor of size 6 sq mm 3 core complete all as specified and directed.
M&L for brick masonary valve pit chamber of size 90 cm x 90 cm x 90 cm (internal sizes of chamber ) with and including MS sheet cover fabricated from 3.15 mm thick MS sheet and frame of angle iron 50 mm x 50 mmx5 mm with fixing arrangement, hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc. 50 mtr, 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6), 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) complete all as specified and directed.
Supply, installation, connecting and testing sluice valve,non rasing type spindle, cast iron body & wedge with Bronze wedge ring on both side, gland packing, class - PN 1.6 with flanged ends drilled suitable for bore of pipe 100 mm ISI marked (IS:14846:2000) having S.S spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc complete all as specified and directed.
Supply and fix Chian pulley block 2 ton capacity electrically operated complete all as specified and directed.
Supply, installation, testing and commissioning starter panel with auto unit weather and vermin proof factory fabricated LT panel board (415 Volts, 50 Hz , 3-phase, 4 wire supply) with and including following:-
EXTERNAL ELECTRIFICATION M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron strip earth 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of protection pipe galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete as detailed below and all as directed.
NOTES FOR ITEM NO 34.00:- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 5 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth GI earth strip 32 x 6mm. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Rubber mat of size 1mx2mx19mm thick complete all as specified and directed.
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts indoor type made out 2.0 mm thick CRCA sheet of sides of the panel board,600 Amp aluminium bus bar insulated with PVC sleeves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire , use with angle iron 50 x 50 x 6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type B-1 using 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland with following:
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, 400 Amp aluminium bus bar insulated with PVC sleeves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire , use with angle iron 50x50x6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type B1 using 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland with followings: (a) MCCB 4 pole 160 amps 35 KA -01 NO (INCOMING) (b) MCCB 4 pole 63 amps 35 KA -07 NOs (OUTGOING)
Supply, Install , testing and commissioning of LT F/P of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, 200 Amp aluminium bus bar insulated with PVC sleeves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1 : 2 : 4 type B1 using 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland with followings: (a) MCCB 4 pole 63 amps 35 KA -01 No (INCOMING) (b) MCB DP 32 amps 10 KA -08 Nos (OUTGOING)
Supply, Install , testing and commissioning of LT F/P of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, 200 Amp aluminium bus bar insulated with PVC sleeves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1 : 2 : 4 type B1 using 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland with following: (a) MCCB 4 pole 63 amps 35 KA -01 No (INCOMING) (b) MCB DP 32 amps 10 KA -04 Nos (OUTGOING)
Note For Ser item No 36.00 to 39.01 (i) All MCCB with thermal release & 35kA Breaking Capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu for short circuit breaking capacity of minimum 35KA rms at 415 Volt 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer.
Supply, install, testing & commissioning of solar light system of 36 watt white LED, lumine out put > 120 lumine/watt out door type automatic dusk to dawn, control indication of charging and low battery protection against module reverse current flow over charge, deep discharge reverse polarity & over load, maintanance free battery 12 volt 100 AH (lead acid-gel type), solar plate 130 Wp, low maintenance fitting totally enclosed in canopy & bowl uv stablized polycarbonate mounted on GI medium grade ISI marked pole of dia 80 mm & 6 meter height above the ground ,Fitting fixed with MS frame ,galvanized finish & MS battery box powder coated & including necessary earth work excavation cement concrete foundation etc complete all as specified & directed.
Supply, install, testing & commissioning of outdoor 12 KV 630 A 21 KA for 3 sec with internal Arc of 21 KA for 1 sec for both tank and cable box , SF6 insulated completely Motorised Operated Ring man with RMU Tank made of 2 mm thick stainless steel, manul tig/Robotic welding & with front cable termination. RMU Bus bar shall be of Copper & RMU coupling shall be from side only. RMU as complete consisting of with Right hand Side Extensible-2 Nos 630 Amp VCB as Incomer & 2 Nos 630 Amp VCB as Outgoing with SCADA Compatible Overload and Earth Fault protection (DPX Type Protection Relay) , Metering Panel ( Meters for VCB Feeder), capacitance voltage indication, Fix type VPIS, cable boot for VCB including necessary foundation as per manufacture recommendation and making electrical connections complete all as specified and directed.
Cutting macadam / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 and matching with the surroundings complete all as specified and directed.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as specified and directed. (Note:- For the purpose of payment only punned thickness will be measured.)
Material and labour for Jodhpur stone slab for protection of under ground cable 25 to 30 cm wide, 40 to 50 mm thick and not less than 60 cm in length with gap between adjacent slab n.exc 10 mm over underground cable laid dry and abbuting each other complete all as specified and directed..
M&L for cable route marker with PCC 1:2:4 type B1 using 12.5 mm stone aggregate of square size 15cm x 15cm x90 cm (height) duly grouted in ground with PCC and planting depth of 30 cm, duly embossed/grooved, painted with synthetic enamel paint on indicator as letterig " MES LT/HT cable" and including two coats white wash over the exposed surfaces complete all as specified and directed.
LIGHTING PROTECTION Material and labour for bore well earthing by drilling 6 " bore with bore machine up to 30 mtr depth and providing 50mm dia heavy duty GI pipe duly drilled all around 15 mm dia hole at a distance of 200 mm from hole to hole upto min 20 mtr depth upto water level and providing charcoal / sulfer mixture all around the pipe and connecting top edge of pipe with galvanized earth strip 32x6 mm upto 7.5 Mtr complete all as specified and directed.
Supply only FRGP hollow dunnage blocks made of Fibre Reinforced Glass Plastic with minimum 25% glass content in reinforced members, UV resistant, Fire resistant, High load bearing size 300X300X200 mm length X 10 mm wall thickness capable of taking load upto 5 Ton complete all as specified and directed.
S&F decorative box type LED tube light fitting 1x20 watt including LED tubular lamp with IP20 protection, inbuilt driver etc complete with all accessories internally pre-wired including connecting up with twin core twisted flexible copper conductor cable of 1.0 sq. mm size complete all as specified and directed.
S&F energy saving 7 watt LED bulb complete all as per specified and directed.
S&F LED Security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 10 KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT 5700-6000 CRI greater than 70, input power 30 W system with 100 lumens per watt output operating voltage 160-260V with connection by three core PVC insulated multistaranded copper conductor sheathed cable of size 1.0 SQMM fixed with & including bracket made of GI Pipe 40mm bore light grade , 1.5 Mtr long bent to shape required with 2 Nos MS clamps of suitable size and length, nuts & bolts complete all as specified and as directed.
NOTES FOR ITEM NO 51.00:- (i) The LED lights shall have gurantee for 5 Years from date of completion of contaract , any defects noticed during this period shall have be rectified / Parts replaced immediately, security amount of 10% of the cost of the item shall be retained with the Deptt till end of the guarantee period. (ii) LED light manufacturer lab shall be accredited to NABL.
S&F ceiling fan 1400 mm sweep complete with copper winding 5 star rating complete operated on 250 Volt single phase supply complete all as specified and directed incl down rods and connecting up with 3 runs of 1.5 sq mm, single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked, from ceiling rose to fan all as specified and directed.
S & F exhaust fan 280 mm sweep double wall bearing type complete with copper winding complete operated on 250 Volt single phase supply complete all as specified and directed incl connecting up with 3 runs of 1.5 sq mm, single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked, from ceiling rose to fan all as specified and directed.
S&F of MCB having 10 KA rupturing capacity in DB's of the following rating complete all as specified & directed
SP, 6 to 32 amp curve 'C' 240 volts
DP, 6 to 32 amp curve 'C' 240 volts
M&L for Sub main wiring with Two runs of 4.0 Sqmm size main cable and one run of 4.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specefied.
NOTES FOR ITEM NO 55.00:- The above mentioned specefied runs of single core cables and specefied runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one runs length. The small extra lengths required for loops etc for connection in DBs are deemed to the included and only the cable covered in conduit shall be measured.
M/s Khanna Enterprises
FRIZO INDIA PVT LTD
Jeet Construction
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
Jatan Constructions Private Limited
RAGHUSONS INFRA ENGINEERING PVT. LTD
MADAN MOHAN JAIN sons
MATA DEEN RAM CHANDRA AGARWAL
DHARIWAL TRADERS PRIVATE LIMITED
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid