| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L1 | Accepted-AOC L1 bidder found reasonable | |
| 2 | L2₹13.5 L+₹3.1 L (29.2%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted by bidder | |
| 3 | L3₹13.6 L+₹3.1 L (29.4%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted by bidder |
Tender Value
₹17.5 L
EMD Value
₹35,100
Closing Date
7 Feb 2022, 6:00 pmClosed
CWE AF JAISALMER
HQ CWE AF JAISALMER
REPAIRS AND MAINTENANCE OF TRANSFORMER AND ITS CONNECTED WORK AT AF STN PHALODI
2022_MES_500569_1
80171/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF PHALODI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF PHALODI
₹35,100
Yes
2 Mar 2022
10 Jan 2022
14 Feb 2022
10 Jan 2022
7 Feb 2022
24 Jan 2022
Amount
Service, overhaul, maint and repair of transformers of capacity 63 KVA to 100 KVA, taking out and transport to workshop for replacement of burnt out winding comprising as under:- (a) Disconnecting of transformer from electrical circuit /pole/plinth mounted out door /indoor type of any make of capacity 63 KVA to 100 KVA. Lifting up transformer at the site and shifting to the vehicle taking out for repair. (c) Opening the top cover to carry out repair at workshop (b) Draining out transformer oil complete removing sludge/carbon particles from bottom core & coils, washing core using drained transformer oil. (d) Reassembling of top cover and reconnecting to electrical system, testing and commissioning of transformer. Note :- (i) Refiling, Dehydration and filtration of oil, replacement of parts, gasket, copper winding at HT and LT, insulation paper etc will be measured and paid separately under relevant items. (ii) Quoted rates are inclusive of transportation from work site to workshop and back and testing at site after necesssary electrical connection complete all as specified and directed.
All as per Serial Item No.1.00 here-in-before but of capacity exceeding 100 KVA but not exceeding 500 KVA
Dehydration, filtration, heating and refilling of old transformers oil after testing the same for dielectric strenghth not less than 65 KV (RMS). Note:- Dehydration and filtration can be carried out at site by brining filtration machine at site otherwise the same shall be got done from the manufacturing workshop of Transformers.
Supply and top up transformer insulating oil HV grade having electric stength not less than 45 KVA (RMS) at 4mm gap. High viscosity in transformer conforming to IS-335 of 1983 as amended complete all as specified and directed.
Supply, fix and test in replacement; externally operated tap changing gear off load type on HV winding to vary the LV voltage upto 7.5 % variation limit in steps on 2.5% suitable upto 250 KVA transformer complete all as specified and directed.
All as per Serial Item No. 5.00 here-in-before but capacity 300 KVA to 500 KVA.
S& F in replacement; ceramic Bush insulators with brass spindle complete with washers, nuts and check nuts on HV side as per existing size, shape and specification for 11/0.433 KV transformer (outdoor/indoor) type transformers of capacity not exceeding 250 KVA complete all as specified and directed.
All as per Serial Item No. 7.00 here-in-before but capacity 300 to 500 KVA complete all as specified and directed.
S& F in replacement; ceramic Bush insulators with brass spindle complete with washers, nuts and check nuts on LV side as per existing size, shape and specification for 11/0.433 KV transformer (outdoor/indoor) type transformers of capcity not exceeding 250 KVA complete all as specified and directed.
All as per Serial Item No. 9.00 here-in-before but capacity 300 KVA to 500 KVA.
S& F in replacement; cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capcity not exceeding 250 KVA 11/0.433 Volts transformers complete all as specified and directed.
All as per Serial Item No. 11.00 here-in-before but capacity 300 KVA to 500 KVA.
S& F in replacement; cork sheet gasket of 6 mm thick out to size/shape for top cover of transformer upto capacity 250 KVA.
All as per Serial Item No. 13.00 here-in-before but transformer of capcity exc 300 KVA and upto 500 KVA.
S& F in replacement; silica gel breather assembly of metallic body including silicagel for distribution transformer of capcity not exceeding 250 KVA complete all as specified and directed.
All as per Serial Item No. 15.00 here-in-before but capacity 300 KVA to 500 KVA.
S& F in replacement; temperature gauge 0 to 150 degree celsius as per existing dia at site suitable for 11/0.433 KV transformer all as specified and directed.
M&L for painting of transformers externally spray painting with synthetic enameled paint of gray color after cleaning surfaces thoroughly with thinner and scrapper and preparing the surface to required standard including writing and marking such as MES No on the body of transformer capacity upto 200 KVA including colour wash of transformer platefrom complete all as directed.
All as per Serial Item No. 18.00 here-in-before but capacity 250 KVA to 500 KVA.
M&L for rewinding of HV coil of transformer of any capacity using proper size DPC super enameled copper winding wire of appropriate guage and grade,with insulation material suitable for HT 11 KV transformer including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
Re-insulation of HT coil of transformer of any capacity using proper size paper insulation material to form DPC Copper wire and HT insulation material suitable for 11/0.433 KV transformer complete all as specified and directed. Note : Item shall be measured only where re-insulation of copper wire is required.
M&L for rewinding of LV coil of transformer of any capacity using proper size DPC super enameled copper winding wire of appropriate guage and grade, and insulation material suitable for 11/0.433 KV transformer including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
S& F in replacement; insulation LV coil of transformer of any capacity using proper size paper insulation material to form DPC copper wire and LT insulation material suitable for 11/0.433 KV transformer complete all as specified and directed. Note : Item shall be measured only where re-insulation of copper wire is required.
Note for Item No 20 to 23: (a) Rewinding of transformer HV/LV Coils shall be carried out from ISO certified 2008 Co. Unit rate quoted by the contractor shall be deemed to be included for necessary transportation means required to move transformer from work site to workshop and back. (b) Dehyderation and filteration of transformer oil and replacement of unserviceable spares shall be measured and paid seperately under appropriate Item of schedule. However cost of renewal of nut, bolts & washers shall be deemed to be included in unit rate quoted by the contractor.
M&L for replacement of Earthing complete with galvanised steel earth plate electrode 60 X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 32X6 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, and cover 6 mm thick in cement concrete (1:2:4) type B1, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs with earth resistance not more than 5.0 Ohms complete all as specified and directed . Note- In case earth resistance more than 5.0 ohms, the contractor will do re-earthing without any extra cost to Govt.
S&F in replacement; earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or burried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required 32X6mm galvanised iron strip complete all as specified.
S& F in replacement; vertical type air break switch gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 Volts, 400 Amps current rating complete including dismantling existing one all as specified and as directed.
S&F in replacement; drop out fuse unit, expulsion type for outdoor air break gang operated switch, single pole mounted on and including insulators for 11KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capacity suitable for current carrying capacity upto 100 Amps, including taking down old one complete all as specified and directed.
S&F in replacement; lightening arresters for 11000 Volts, expulsion type, with all fittings, transmision class, discharge capacity 65 KA complete all as specified and directed.
S& F in replacement; cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
S&F in replacement; cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable, including cutting and removing existing unserviceable joint, excavation near 2/4 pole structure / HT Panel board / Transformer and taking out loop cable from trench and excavation refilling the trench shall deemed to be included in quoted rate with excavated material all as specified and as directed.
S&F in replacement; cable end jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable including cutting and removing existing unserviceable joint, excavation near 2/4 pole structure / HT Panel board / Transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
S&F in replacement; cable end jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable including cutting and removing existing unserviceable joint, excavation near 2/4 pole structure / HT Panel board / Transformer and taking out loop cable from trench and refilling the trench with excavated material all as specified and as directed.
S&F anti-climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
S&F inreplacement; 25x20cm size, danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 11000V supply, 25x20cm size complete all as specified and directed.
Supply,lay and spread 80mm thick layer of 40mm graded stone aggregate of any description and in any position at electrical 2/4 pole structure all as directed.
Disconnecting / dismantling primary & secondary (HT/LT) connection carefully of unservicable / serviceable out door / indoor type Transformer complete of any capacity from its foundation and safely shifting one sub station to another sub station where as directed by Engr-in-charge and reconnection of cabling ,earthing ,install testing and commissoning of the transformer. Note:- Cost of Necessary tools and plants such as Vehicle, hydra/Crane etc should be deemed to be included in the unit rate quoted.
Supply and lay in replacement; synthetic rubber insulated mats 2mm thick of size 2mx1m for voltage upto 11 KV for electric purpose as per IS 15652-2006 suitable for electric shock safety complete all as specified and directed.
L C ASSOCIATES
SS SODHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .