Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC BEING LWEST BIDDER | |
| 2 | L2₹32.7 L+₹30,967 (0.95%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹33.1 L+₹63,769 (1.97%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹34.6 L+₹2.2 L (6.71%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
1 Mar 2021, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-53/2020-21 MANNING AND OPERATION OF PUMP SETS, DG ETS, DG SETS, STP, REPAIRS TO WATER PIPE LINES, UNDERGROUND SUMPS, SWTs ELECTRICAL INSTALLATION, INTERNAL ELECTRIFICATION CEILING FANS COOLING APPLIEANCES DESER COOLERS EARTHING PITS
2021_MES_417751_1
GE AF/AMB-53/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE AF AMBALA
ALL AS PER NIT AND TENDER PAGES
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹80,000
Yes
5 Apr 2021
1 Feb 2021
3 Mar 2021
1 Feb 2021
1 Mar 2021
16 Feb 2021
8 Feb 2021 - 13 Feb 2021
Amount
PART-I (M&O WORKS)
Manning and operation of sub-station by providing one skilled electrician for 03 (three) shifts (each shift of 08hours, one electrician for each shift), including switching and attending to switch gears, maintaining electrical log sheets on all days including Sundays & holidays, round the clock for trouble free functioning of the installations in technical area complete all as specified hereafter and as directed by the Engineer-in-Charge
Manning and operation of sub-station having underlaid equipment by providing one unskilled male mate / helper for 01 (one) shift of 08hours, for assistance to electrician / FGM on all days including Sundays & holidays, for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge
Manning and operation of water supply installations and STP as described here under by providing one skilled FGM for 02 (two) shifts (each shift of 08hours, one FGM for each shift) on all days including Sundays & holidays, for trouble free functioning of the installations complete all as specified hereafter and as directed by the Engineer-in-Charge (i) Submersible pump set of capacity upto 30HP electric driven with LT panel starter, sluice valves, for boosting / feeding OHTs (ii) Chloronome plant and bleaching doser (iii) Standby DG set in pump house (iv) Sewage treatment plant with boiler, electric panel
Manning and operation of DG sets of various capacities installed at IMMOLS, logestic section, transmitter building near SATCOM and maintenance complex, receiver building, OPs room, MRS (near MES office) and standby power suppy to server by providing one skilled FGM for 03 (three) shifts (each shift of 08hours, one FGM for each shift) on all days including Sundays & holidays, for trouble free functioning of the installations including comprehensive maintenance complete all as specified hereafter and as directed by the Engineer-in-Charge
Notes for serial item Nos. 1.00 to 5.00: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) The minimum wages as derived by the Department including all statutory provision such as EPF, ESIC, Bonus, GST, etc. as applicable except the Contractor's profit for skilled person works out to Rs. 765/-per person per shift and for un-skilled person Rs. 615/- per person per shift (iii) Bidder has to upload an signed undertaking in firm's letter head confirming that he has not quoted his rates lower than the derived minimum rates of the Department. Bids not accompanied with such undertaking shall not qualify for opening of the price bids. As applicable, his tender will be treated as 'NON BONAFIDE' if found at any stage and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only.
(iv) However increased minimum fair wages as notified time to time by the Government of India / State Government / Local bodies / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, irrespective of derived minimum wages as above (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase shall be passed over to the workers (vi) Rates quoted by the bidder shall be deemed to be inclusive of any extra manpower required (if any) for relieving, replacement, etc. (vii) The operator placed shall be responsible to attent complaints concerned to the location as directed (viii) Conveyance/vehicle for moving around of the staff employed on such occassions shall be provided by the Contractor (ix) A penalty of Rs. 500/- per complaint shall be imposed on non-attending of such complaints as directed. Such penalties shall be recovered immediately from corrosponding RARs/FB of the Contractor.
PART-II (REPAIRS & OTHER WORKS)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V (earthed) grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out / down old unserviceable cable, protection pipes, brick covers, etc. from any location and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, covers, tubing, cushioning will be measured and paid separately under respective item herein
2 core 10sqmm
4 core 16sqmm
4 core 25sqmm
3.5 core 35sqmm
3.5 core 50sqmm
3.5 core 70sqmm
3.5 core 95sqmm
3.5 core 120sqmm
3.5 core 150sqmm
3.5 core 185sqmm
Supplying, laying / fixing, testing and commissioning of 3 core 95sqmm electric cable 11000V grade earthed aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, PVC type ST-2 outer sheath conforming to IS-5831-1984 including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundation filling, mass concrete, etc. complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as in coping to electric poles, etc. including all necessary formwork complete all as specified and as directed
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
S&F cable route/path indicator made out of 300x300x1.6mm thick MSl sheet duly rivetted and welded to 600mm long MS angle iron of size 30x30x5mm and duly embedded in PCC 1:3:6 type C-2 block of size 300x300x300mm including necessary excavation and earthwork and painting all exposed steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and writing size and voltage of cables complete all as specified and as directed
M&L for cleaning and utility servicing HT Vacuum Circuit Breaker (VCB), 11kV (outdoor type), 400/630Amp, 3 phase, checking of each moving parts, spring charging system, triping system, indication system, metering system, remote operation, closing & trip coil assembly and proper oiling, greasing and proper adjustment of trip bars, closing bar complete with the following testings complete all as specified and as directed (i) ON/OFF testing in local and remote position (ii) Spring charge system (iii) Tripping test in overload and earth fault position by external current injecting Kit on both primary & secondary sides (iv) Meggar testing between phase to phase and phase to earth in ON / OFF position both (v) Calibration of earth fault / over current relay Notes: (a) Tests shall be carried out through competent labs / test houses / authorised service centres as approved by the GE (b) All the test reports shall be submitted to the Engineer-in-charge and shall be made part of RAR / FB
M&L for cleaning and utility servicing transformer upto 200A (indoor / outdoor type), checking of entire system, plugging of oil leakages, adjustments to changeover switch, etc. to ensure smooth functioning including providing all damaged / work out minor spares / parts and testing as per relevant IS complete all as specified and as directed Notes: (a) Tests shall be carried out through competent labs / test houses / authorised service centres as approved by the GE (b) All the test reports shall be submitted to the Engineer-in-charge and shall be made part of RAR / FB
M&L for disconnecting, dismantling and removing transformer of capacity 200kVA, any make / any type (indoor/outdoor) from any locations / site, transporting the same to workshop, opening, draining out oil, taking out core assembly in the presence of JE/Engineer-in-Charge and estimating the repairs of damaged parts, cleaning /washing of tank removing the dirt sludge and sticky materials from all parts of the transformer including core tank and cooling tubes, removal of damaged parts, re-assembling after replacement of damaged parts of the transformer after repairs including preparation of old surfaces and painting with two coats of synthetic enamel paint (grey tint) on entire outer surfaces, writing trnasformer No. etc. making all connections and filling with fresh transformer oil and dehydration of oil by wax centrifuging and testing for all type of tests including reinstallation of transformer at site complete all as specified and as directed Note: Rate quoted shall be inclusive of cost of all de-installing, loading / unloading, carting, reinstalling, etc. to and fro from site to workshop all necessary T&P, performance test before bringing in from workshop, etc. complete
M&L for taking out burnt winding of HV side of transformers carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge or DPC winding wire, including providing new insulating material, cotton tape, packing, sleeves, and varnishing by vacuum impregnation, baking coil core assembly and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of LV side of transformers carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge or DPC winding wire, including providing new insulating material, cotton tape, packing, sleeves, and varnishing by vacuum impregnation, baking coil core assembly and testing for proper functioning complete all as specified and as directed
M&L for disconnecting and taking off HT/LT connections of existing transformer indoor/outdoor type, mounted on 2/4 pole structure keeping aside safely and repairing the platform including damaged portions PCC/RCC/brickwork, 10mm thick plastering in CM 1:4, 2 coats of white wash on all surfaces, etc. as required at site and refixing in location the transformer suitably with new nuts, bolts, etc. and reconnecting, testing on charging, etc. complete all as specified and as directed
Supply, fixing, connecting and testing charging gear box for 11kV, VCB, operated on 230/24V AC/DC of existing rating, size, type duly synchronised with existing system complete all as specified and as directed
Supply, fixing, connecting and testingvacuum interpretor set (stud/non-stud type) for 11kV, VCB, operated on 230/24V AC/DC of existing rating, size, type duly synchronised with existing system complete all as specified and as directed
Supply, fixing, connecting and testing spring charging motor (universal motor) for outdoor type, 11kV, VCB, operated on 230V AC/ DC, with charging time less than 15seconds of approved rating complete all as specified and as directed
S&F shunt trip coil assembly suitable for HT, OCB/ VCB, operating on 24/110V system and testing complete all as specified and as directed
S&F closing coil operated on 110/24V system suitable for working of relay of HT OCB / VCB complete all as specified and as directed
S&F under voltage coil assembly suitable for HT OCB/ VCB operated on 110/24V system and testing complete all as specified and as directed
S&F half gear assembly suitable for HT, OCB/ VCB, operating on 24/110V system and testing complete all as specified and as directed
S&F in repairs indication lamp (LED type) Red / Yellow / Green colour suitable for 110V AC / 110V DC / 30V DC (as required at site) complete all as specified and as directed
S&F in repairs electric heaters suitable for VCB (as required at site) complete all as specified and as directed
M&L for switch air break gang operated, tripple pole, mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level for current rating up to 200Amps 11000V grade with 12 insulators including 25mm dia GI medium grade pipe, supports worked from ground level vertically operated including taking down old unserviceable switch from existing place and disposing off complete all as specified and as directed
M&L for carrying out tests for locating faults in LT cable of size 25 to 300sqmm with the help of fault locator machines, etc. including digging in and earthwork if necessary complete all as specified and as directed
S&F lightening arrestor, set of 3, expulsion type, 65kA discharge capacity transmission class, suitable for 11kV system including staging as required complete all as specified and as directed
M&L for filteration, dehyderation and checking of transformer oil including necessary connection, testing, etc. on refilling / re-pouring into equipments complete all as specified and as directed
Supply & filling the transformer oil (as per IS 339-1989) breaking down capacity more than 50kV to replace/topping up low breaking down capacity oil in at site including filteration & dehyderation complete all as specified and as directed
S&F in replacement silicagel of existing specification complete all as specified and as directed
S&F in repairs LT/HT side bushes of existing size, specifications and make of equipment complete all as specified and as directed
S&F in repairs HT/LT bushing rubber (ring) gasket set (3Nos. for HT side and 4Nos. For LT side) of transformer complete all as specified and as directed
S&F in repairs transformer top gasket (cork sheet) complete all as specified and as directed
S&F in repairs bus bar insulator for 11kV VCB as per existing type and size complete all as specified and as directed
S&F in repairs insulation support set panel for 11kV VCB as per existing type and size complete all as specified and as directed
S&F in repairs insulating sleeves of HT VCB of capacity 630A 11kV resin cast insulators complete all as specified and as directed
S&F in repairs single phase preventor VSP 3 for 415V 50Hz complete all as specified and as directed
Supplying and filling in bentonite base earthing enhancement backfill compound in existing earth pits as per relevent IS and achieving the desired earth results complete all as specified and as directed
S&F in repairs power capacitor, power quality heavy duty 20kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power capacitor, power quality heavy duty 10kVAR, 440V, 50Hz, double dielectric capacitor required phase discharge device with resistance appropriate insulation level and rated current including suitable sized copper conductor cable, thimbles, diode and testing on fixing and connecting up complete all as specified and as directed
S&F in repairs power factor controler PFC-14 relay, single phase, 230V, 50Hz complete all as specified and as directed
S&F in repairs power contactor 3 pole with AC/DC coil for 20kVAR power capacitor including all connections and testing complete all as specified and as directed
S&F in repairs power contactor 3 pole with AC/DC coil for 10kVAR power capacitor including all connections and testing complete all as specified and as directed
S&F synthetic insulating mat of size 2x1m x 25mm thick suitable for HT 11000V imnstallation including bolting, etc. complete all as specified and as directed
M&L for disconnecting and taking out capacitor bank panel from foundation, in any location, removing to store / workshop for repair works including testing and calibration of APFC relay, repairs to on delay timer, repair/replacement to indicating lamps, repair to all necessary internal wiring of panel with required size copper lead along with lugs, repairs to power capacitor, repair/replacement of 3 position spring return switch with NO & NC elements, repair to ON Delay suitable for mounting on contactors timer and reinstalling panel in its original position including making good the disturbed foundation / platform complete all as specified and as directed Note: Rate quoted shall be inclusive of all necessary T&P, loading / unloading, carting to and fro to workshop, etc.
M&L for cable jointing kit for 11kV earthed grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, indoor termination type, for 11kV earthed grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, 95mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 1100V earthed grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core, 25mm² to 70mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit, outdoor termination type, for 1100V earthed grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core, 95mm² to 185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F in repairs battery charger 240V 50Hz charging range 6 to 24volt with trickle / boost charging mode complete all as specified and as directed
M&L for servicing and repairing AMF panel for 63kVA DG set at site including changing of contactor (2NO+2NC BCH15 T22 BCH 15) and relay (MC320KE32 MD DMD control relay) and all other minor unserviceable spares/items and making the panel functional complete all as specified and as directed
S&F battery 180AH 12V, set including initial charging, filling of distilled water, etc. and testing on installation and taking off and disposing off old unserviceable battery complete all as specified and as directed
S&F battery 88AH 12V, set including initial charging, filling of distilled water, etc. and testing on installation and taking off and disposing off old unserviceable battery complete all as specified and as directed
M&L for collecting unserviceable voltage stabilizer of capacity 3 to 5kVA from store yard Patiala, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted in this item
S&F printer circuit control card suitable for 3kVA voltage stablizer complete all as specified and as directed
S&F printer circuit control card suitable for 3 to 5kVA voltage stablizer complete all as specified and as directed
S&F input / output switch suitable for 3 to 5kVA voltage stablizer complete all as specified and as directed
S&F push on switch suitable for 3 to 5kVA voltage stablizer complete all as specified and as directed
S&F indicator with bulbs suitable for 3 to 5kVA voltage stablizer complete all as specified and as directed
S&F trigger transformer suitable for 3 to 5kVA voltage stablizer complete all as specified and as directed
S&F relay suitable for 3 to 5kVA voltage stablizer complete all as specified and as directed
S&F analog type voltmeter, 0 to 300V single phase 50Hz suitable for voltage stablizer complete all as specified and as directed
S&F digital type voltmeter 0 to 300V single phase 50Hz suitable for voltage stablizer complete all as specified and as directed
S&F time delay and high / low voltage cutoff circuit with relay suitable for 3 to 5kVA voltage stabilizer complete all as specified and as directed
M&L for arresting leakages in GI/CI pipelines of 15 to 50mm bore by replacing and inserting new length of pipe upto 1.5m long including all necessary cutting, threading, etc. with and including new fittings viz. nipples, unions, elbows, Tee, sockets, bends, etc. as required complete all as specified and as directed
M&L for arresting leakages in GI/CI pipelines of 80 to 150mm bore by replacing and inserting new length of pipe upto 1.5m long including all necessary cutting, threading, etc. with and including new fittings viz. nipples, unions, elbows, Tee, sockets, bends, etc. as required complete all as specified and as directed
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for connection and tapping from existing supply pipe lines to resume water supply, as in passing through pipes, etc. including taking up/down old unserviceable tubings and disposing off complete all as specified and as directed for the following bores:
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
M&L for taking out old / damaged CI/DI pipes and disposing off including burning out, recovering and storing lead from joints, etc. complete all as specified and as directed of the following sizes:
100mm bore
150mm bore
M&L for DI pipes with socketed and spigot ends suitable for tyton joints centrifugally cast (spun) class LA conforming to IS:1536 cut to any length and laid in trenches including rubber gaskets joints complete all as specified and as directed of the following sizes: Note: Fittings shall be measured and paid separately under respective item
100mm bore
150mm bore
M&L for run lead joint for CI/DI pipes including jointing material like spun yarn, lead, etc. and burning out and disposing old lead complete all as specified and as directed for the following bores:
100mm bore
150mm bore
M&L for flanged joints for CI/DI pipes including nuts, bolts, washers, rubber gaskets, fiber boards, etc. complete all as specified and as directed for the following bores:
100mm bore
150mm bore
M&L for CI/DI specials / fittings like bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc.), tee pieces single branch 'Y' junction, double branch, cross (all sockets or socket and spigot), collars, caps, plug, etc. upto and including 200mm bore complete all as specified and as as directed Note: Lead joint, excavation and earthwork shall be measured and paid separately under respective items
S&F sluice valve cast iron body class PN 1 marked both ends fanged with brass spindle and brass check nuts with cast iron hand wheel including jointing material like rubber insulation sheet 3mm thick, bolts, nuts and fixed to pipe line, including testing on installation and taking out of old unserviceable valve and disposing off complete all as specified and as directed of the following sizes:
150mm dia
100mm dia
S&F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, and earthwork in any type of soil or breaking/cutting into road/interlocking tiles/cement concrete, etc. and making good the disturbed surfaces complete all as specified and as directed of the following sizes:
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
M&L for removing / taking out motors of pumps by dismantling the pump for assessing and making good for running conditions by repair / replacement of all unserviceable spare parts like upper lower bearing, seal assembly, bottom plate, cable gland, neoper cable protector, cable seal, cable clamp and screw, plug joint ring, gasket neoper, circlip spring, impeller key, impeller nut, electronic timer, eye bolt, etc. as required, re-winding with super enameled copper wire of existing gaugeand pattern, replacement of O ring set, full fasteners set & Nitrile `O` ring set, checking of all bearings & mechanical seal by cleaning greasing and reassembling the same including hydraulic air testing and balancing, changing of lubricant oil, re-assembling and making necessary connections, testing complete all as specified and as directed for the following:
5HP submersible water pumping set
5HP non-clog type submersible sewage pumping set
M&L for rewinding of motor upto 35HP of submersible water pumping set with suitable size of copper winding wire including all insulation material & motor winding provided with thermal switches for protection against excessive temperature rise complete all as specified and as directed
S&F in position decrin dosing pump of capacity 4.0lpH, maximum pressure 5.5kg/sqcm, stroke speed upto 100 strokes/min, including all necessary connections fittings, and testing on installation complete all as specified and as directed
M&L for taking out from any position / location and dismantling blowers of motors for servicing by cleaning the bearing, bush with suitable cleaning solutions, finding and replacing unserviceable items line bearing, nut, bolt, washer, and greasing all moving parts and reassembling the same and inserting in original position and connecting up, testing for smooth functioning complete all as specified and as directed
M&L for cleaning of internal surfaces of RCC overhead tank of 75000 gallons capacity including staging to a height approx 18m, etc. by scrubing the surfaces with the help of coir brush, jute cloth and flushing out all the accumulated mud / silt inside the tank, then applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc. and writing tank number, capacity of tank, date of cleaning with white synthetic enamel paint over a black synthetic enemal paint base (of suitable dimensions) with size of letter 4" height complete all as specified and as directed
M&L for desilting and cleaning of MBBR tank, tube settler tank, CCT tank, TWT tank of STP by scrubing the surface with the help of coir brush, jute cloth and flushing out all accumulated mud/silt/scum including cleaning of flow rotameter using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks, and applying two coats of lime wash to all internal surfaces and writing date of cleaning, etc. complete all as specified and as directed
M&L for desilting and cleaning of equilisation tank of STP by scrubing the surface with the help of coir brush, jute cloth and flushing out all accumulated mud/silt/scum including cleaning of flow rotameter using mechanical pumps, diesel driven, with fuel, operator, etc. and all necessary tools / plants including loading and carting off the drawn sludge, waste material, scum, spoil water, etc. outside MD land through designated sludge carriers / bio tanks, and applying two coats of lime wash to all internal surfaces and writing date of cleaning, etc. complete all as specified and as directed
M&L for cleaning and preparation of surfaces of STP plant pipe, any size, and spray painting in one coat of synthetic enamel paint of approved tint complete all as specified and as directed
M&L for laying sand in filtering / media bed including cleaning off the tank bed and disposing off old sand bed outside MD land including all necessary lifting/carting /loading/unloaging etc. complete all as specified and as directed
Supply and pouring / adding in chlorination chemical highly efficient (high strength) calcium based granular disinfectant, more stable than chlorine gas, highly stable, water at various locations complete all as specified and as directed Notes: (i) Paid vouchers of calcium based granular disinfectant shall be submitted (ii) The calcium based granular disinfectant shall be brought at site/store in sealed plastic container of appropriate capacity / size asked (iii) The brand of chemical shall be as approved by the GE
M&L for chemical analysis testing of water samples for pH colour, odour, taste, turbidity, total hardness, total alkalinity, iron, chloride, residual free chlorine, fluoride, total dissolved solid, sulphate, nitrates, total coliform,, e-coli, etc. taken suitably from sources at various locations complete all as specified and as directed Notes: (i) The tests shall be carried out through NABL accredited laboratories. Contractor has to submit details of such lab to the Engineer-in-charge and gain approval of same from the GE. (ii) The tests shall be carried out in accordance to the stipulations of relevant IS and procedures (iii) Test reports shall be submitted in triplicate to the Engineer-in-charge.
M&L for construction of brick masonry valve pit chamber of size 1100x1100x 900mm (internal dimension) with 100mm thick foundation using PCC 1:3:6 (type C-2) using 40mm graded stone aggregates, 230mm thick brick masonry wall built in CM 1:6, 10mm thick internal and 15mm thick external plastering in CM 1:4, finished even and smooth without using extra cement and 6mm thick MS sheet cover including 40x40x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x6mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surfaces including excavation and earth work in any type of soil and disposal of surplus soil to a distance of not exceeding 50m, dismantling old / unserviceable chamber and disposing off complete all as specified and as directed Note: The cost shall be inclusive of all items of work required for the execution and entire completion of this item and nothing extra shall be paid separately in any other items of BOQ
M&L for preparation of surfaces of MS flats, welded mesh, etc. viz. scrapping old paints, smoothening, etc. and painting with two coats of synthetic enamel paint (of approved tint) complete all as specified all as directed
M&L for taking down old street light / security light / high mast light / guard post light fittings and refixing after necessary repairs including cleaning of perplex covers, etc., tightening of loose connections on poles / walls, and replacing and dead bulb / tube rod, worn out minor parts, etc. and making the fitting functional complete all as specified and as directed Note: Minor parts, bulb/tube rod shall be measured and paid separately under respective items herein
Supply only open construction ballast 150W suitable for HPSV/MH fitting, 220/240V, 50Hz complete all as specified and as directed
Supply only open construction ballast 400W luminaire type suitable for HPSV/MH fitting, 220/240V, 50Hz complete all as specified and as directed
Supply only HPSV lamp 150W tubular, 240V complete all as specified and as directed
Supply only HPSV lamp 400W tubular, 240V complete all as specified and as directed
Supply only lamp holder suitable for 150W SV/MH lamp, 240V 520Hz complete all as specified and as directed
Supply only Ignitors for 70 to 250W for SON/MH lamp, 240V, 50Hz complete all as specified and as directed
Supply only capacitors 20MFD + 5%, 240V, AC, 50Hz complete all as specified and as directed
S&F heavy duty PVC earth pit cover (bucket type) for existing chemical earthing incliding cap complete all as specified and as directed
S&F LED street light fitting, 45W, 230V, 50HZ, suitable for operation over voltage range of 140V to 270V, duly housed in pressure die cast aluminium housing, compressing of LED with individual optical lens, electronic driver with IP 66 protection and impact reistance of IK 07, including connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting and taking down and disposing off old unserviceable fitting complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to PCC/steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
S&F 1.5m long 40mm bore light grade GI pipe bracket duly cut to size and bent to shape required duly painted with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer, including 2Nos. FI 50x6mm clamps as required to fix on concrete / steel poles and taking down and disposing off old unserviceable brackets complete all as specified and as directed
M&L for bands, straps, supports or stays including bolts, if required hooks (stay), hand made sliding bolts, clamps, hold fasts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 grade E-165 including duly painting with two coats of synthetic enamel paint complete all as specified and as directed
S&F brass earth test points of existing size with nuts and bolts duty embedded at existing location complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 250Amps 50kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 200Amps 36kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 160Amps 36kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 3 pole 3 Phase 415V 100Amps 25kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCCB 3 pole 3 Phase 415V 63Amps 50kA adjustable thermal release type complete all as specified and as directed
Servicing of DG set of capacity 15 to 40kVA 3 phase at site including, cleaning of diesel tank internally thoroughly with water and air pressure, removing the sludge from the tank, opening of oil chamber cover, draining out used engine oil, cleaning the chamber throughly internally and refixing the chamber cover, taking off and replacing worn out / unserviceable parts and making DG set functional including all testing on full load, etc. complete all as specified and as directed
Servicing of DG set of capacity 63kVA 3 phase at site including, cleaning of diesel tank internally thoroughly with water and air pressure, removing the sludge from the tank, opening of oil chamber cover, draining out used engine oil, cleaning the chamber throughly internally and refixing the chamber cover, taking off and replacing worn out / unserviceable parts and making DG set functional including all testing on full load, etc. complete all as specified and as directed
Notes for serial item Nos. 152 & 153: (i) Serviceable parts shall be fixed in position and replacement of unserviceable parts with new parts viz. nuts, bolts, washers, thimbles, wire, fuse, gasket, locking nuts, small springs, `O’ rings, screws, packing material, studs shall be deemed to be included in quoted rate. (ii) Other new replaced parts shall be measured and paid for separately under respective items of BOQ hereinafter
Notes for serial item Nos. 152 & 153 contd: (iii) Engine oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly for checking serviceability including cleaning of oil sump with kerosene oil (iv) Fresh engine oil if oil is replaced shall be supplied by the Contractor and shall be measured and paid separately under respective item of BOQ (v) Rates for replacing components / filling of oil shall be deemed to be included in the quoted rate
Replacement of lubricant oil filter element (set of two) for DG set of capacity 15 to 40kVA
Replacement of fuel filter element (set of two) for DG set of capacity 15 to 40kVA
Replacement of by-pass filter element for DG set of capacity 15 to 40kVA
Replacement of air cleaner filter element set for DG set of capacity 15 to 40kVA
Replacement of fan belt set for DG set of capacity 15 to 40kVA
Replacement of radiator hose pipe of suitable size for DG set of capacity 15 to 40kVA
Replacement of lubricant oil filter element (set of two) for DG set of capacity 63kVA
Replacement of fuel filter element (set of two) for DG set of capacity 63kVA
Replacement of by-pass filter element for DG set of capacity 63kVA
Replacement of air cleaner filter element set for DG set of capacity 63kVA
Replacement of fan belt set for DG set of capacity 63kVA
Replacement of radiator hose pipe of suitable size for DG set of capacity 63kVA
M&L for decanning of used engine oil of DG sets, cleaning the oil chamber, topping uo and filling the same with fresh engine oil of existing make complete all as specified and as directed
Supply and pouring fresh coolant complete all as specified and as directed
M&L for checking/servicing of DG set battery 12V 92/180AH by cleaning the battery terminals with hot water and applying petrolium jelly over terminals, checking water level and topping up with distilled water and testing functionality complete all as specified and as directed Note: Replaced parts / components will be measured and paid separatly under respective items herein
Supply only heavy duty brass battery terminals of existing type, size and make including nuts/bolts
Supply only battery cable 70sqmm multi-stranded copper conductor of existing core
Supply only distilled water for batteries in sealed bottles
M&L for taking out radiator assembly from DG sets, of capacity 40/63kVA, carefully and servicing, cleaning the same internally as well as externally with chemical, cleaning the fins throughly, replacing worn out spares and refixing the same at its original position and testing complete all as specified and as directed Note: Spares / parts replaced will be measured and paid under relevant items herein
M&L for taking out alternator from DG sets, of capacity 40/63kVA, carefully and servicing, cleaning the same internally as well as externally with chemical, replacement of carbon bushes, PCB and refixing the same at its original position and testing complete all as specified and as directed Note: Spares / parts replaced will be measured and paid under relevant items herein
M&L for taking out self starter 12V from DG sets, of capacity 40/63kVA, carefully and servicing, cleaning the same internally as well as externally with chemical, replacement of carbon bushes, bearing, contact blades, etc. replacing worn out spares and refixing the same at its original position and testing complete all as specified and as directed Note: Spares / parts replaced will be measured and paid under relevant items herein
S&F fly wheel ring suitable for DG sets 40/63kVA including dismantling and taking out unserviceable fly wheel ring by separating alternator and diesel engine and testing on completion complete all as specified and as directed
Supply only self starter of capacity 12V suitable for 15 to 63kVA DG set and testing on completion complete all as specified and as directed
Replacement of pinion gear suitable for 40/63kVA DG sets of existing size, type and make
Replacement of armature suitable for 40/63kVA DG sets of existing size, type and make
S&F stopper alongwith relay for 40kVA DG set all as per existing type and size complete all as specified and as directed
S&F relay iOPS-0404D-9/M-7/Y15/N for 40kVA DG set all as per existing type and size complete all as specified and as directed
S&F relay relay of 8 pin suitable for 40kVA DG set all as per existing type and size complete all as specified and as directed
S&F copper thimbles 10 to 95sqmm size of existing type and make complete all as specified and as directed
S&F FRP looping box of size 250x150x105mm with suitable 100A bus bar, 230V, 50Hz and porcelain connector with MCB SP 6Amps, 10kA fixed with and including requisite clamps, nuts, bolts, washers, etc. mounted on poles/ walls, etc. and taking down and disposing off old box complete all as specified and as directed
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, bolts, nuts and screws type 410 SP-31, 9m long with detachable bracket arms including two coats of silver paint over shop coat of primer complete all as specified and as directed
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, ceiling surfaces etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 5A one way switch
One bell point controlled by one bell push
One switch socket outlet 3 pin 5Amps on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed on walls, ceiling etc., and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 3 pin 15A switch socket power point on independent board complete all as specified and as directed
M&L for point wiring with 2 runs of 4sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic rigid PVC casing caping not less than 20mm wide and accessories, concealed in walls / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 3 pin 15A switch socket power point on independent board complete all as specified and as directed
M&L for point wiring with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic rigid PVC casing caping not less than 20mm wide and accessories, surface on walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 3 pin 15A switch socket power point on independent board complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 15A flush type, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 2 in 1, 3 pin, multipurpose 5/15A flush type, ISI marked, 240V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 6A, 240V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 16A, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 6A flush modular type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 16A flush modular type, ISI marked, 240V complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F PVC lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F bell push flush button type, 5Amps, 240V complete all as specified and as directed
S&F bell push flush button modular type, 5Amps, 240V complete all as specified and as directed
S&F bell buzzer, ding dong type, 240V, single pole complete all as specified and as directed
S&F electronic fan regulator, stepped type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F electronic fan regulator, stepped modular type (5 steps), 120W, 50Hz, 240V, ISI marked duly connected up complete all as specified and as directed
S&F modular white cover plate with frame suitable for 2 modules ISI marked complete all as specified and as directed
S&F modular white cover plate with frame suitable for 3 modules ISI marked complete all as specified and as directed
S&F modular white cover plate with frame suitable for 6 modules ISI marked complete all as specified and as directed
S&F modular white cover plate with frame suitable for 12 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 2 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 3 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 6 modules ISI marked complete all as specified and as directed
S&F modular flush box for mounting modular cover plates 12 modules ISI marked complete all as specified and as directed
S&F LED 1x20W batten tube light fitting, wall mounted, extruded heat dessipation, integrated sleek extruded polycarbonate LED channel with white acrylic cover, 230V with connector block, etc. internally pre-wired and connecting up with twin core twisted flexible copper conductor cable of suitable size, with all accessories and 20W LED tube rod including taking down and disposing old fitting any type complete all as specified and as directed
S&F recess mounting 36W LED 2ftx2ft luminaire white coated CRCA housing with LEDs seamless front frame with flat high transmission acrylic cover including all accessories, all internally pre-wired and connecting up with twin core twisted flexible copper conductor cable of suitable size, with all accessories and 36W LED lamp including taking down and disposing old fitting any type complete all as specified and as directed
S&F in repairs flame proof light (FLP-WP), fluorescent fittings groups IIA & II B, IS 2206 (Part II)/1976, 240V, alongwith LED 2x36/40W all internally connected with all accessories complete all as specified and as directed
S&F in repairs digital electric meter single phase, 50Hz, range 10 to 50A rating connected with suitable sized PVC copper cable to DB complete all as specified and as directed Note: Old / unserviceable meters shall be deposited at store of Engineer-in-charge
M&L for submain wiring using proper colour coding with 2 runs of single core 6sqmm, PVC insulated, FRLS unsheathed suitable for 1100volt, multistranded, copper conductor cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100volts green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
M&L for submain wiring using proper colour coding with 2 runs of single core 4sqmm, PVC insulated, FRLS unsheathed suitable for 1100volt, multistranded, copper conductor cable and 1 run of 2.5sqmm multistranded, copper conductor cable 1100volts green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
Notes for serial item Nos. 223 & 224: (i) 2 runs of 4/6sqmm main cable, 1 run of 4/2.5sqmm earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket with and inlcuding one SP MCB 20A 10kA including taking down and disposing off old/unserviceable socket complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 240V SPN 8 way double door, flushed inside walls, etc. with 200Amps rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 240V SPN 12 way double door, flushed inside walls, etc. with 200Amps rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs MCB SPN, 230V, 40Amps 10kA complete all as specified and as directed
S&F in repairs MCB SP 240V, 5 to 40Amps 10kA complete all as specified and as directed
S&F in repairs DP RCBO for earth leakage, overload and short circuit protection, 40A 100mA complete all as specified and as directed
S&F in repairs DP RCBO for earth leakage, overload and short circuit protection, 63A 100mA complete all as specified and as directed
S&F in repairs house service bracket (hook type) fabricated out of 3m long GI tubing 40mm bore medium grade with 02Nos. 90o bends including necessary fixing arrangements with suitable MS clamps, nuts, bolts, washers, etc. and taking down and disposing off old bracket any type complete all as specified and as directed
Taking down carefully exhaust fans (with or without louvers), 230/300/380/400mm, any type, from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Note: Cost of replaced minor spares, winding shall be deemed to be inclusive in the quoted rates
Taking down carefully ceiling fans, 1200/1400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Note: Cost of replaced minor spares shall be deemed to be inclusive in the quoted rates
M&L for cleaning exhaust fans (with or without louvers) of 300/380/400mm sweep from any position / location, removing old worn out paint from fan and blades by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and sutable sized font) in body of fan refixing the fan in position complete all as specified and as directed
M&L for cleaning ceiling fans of 1200/1400mm sweep from any position / location, removing old worn out paint from fan and blades by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and sutable sized font) in body of fan refixing the fan in position complete all as specified and as directed
M&L for taking out burnt winding of exhaust fans of size 300/380/450mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of ceiling fans of size 1200mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of ceiling fans of size 1400mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
S&F PVC 3 core chord, flexible copper insulated cable 24/0.2mm size black/grey in colour and fixed / laid complete all as specified and as directed
S&F ball bearing and bush of existing size for exhaust / wall mounted fans 300/380/ 450mm sweep complete all as specified and as directed
S&F ball bearing and bush of existing size for ceiling fans 1200/1400mm sweep complete all as specified and as directed
S&F canopy (set of two) of existing size, colour and design suitable for ceiling fans (set of two) complete all as specified and as directed
S&F rubber reel of existing size and make suitable for 1200/1400mm sweep ceiling fans with nuts, bolts and wahsers, etc. complete all as specified and as directed
S&F condenser 2.5/3.5/4MFD for ceiling fans / exhaust fans complete all as specified and as directed
S&F gun metal bushes of existing size and make suitable for 1200/1400mm sweep ceiling fans complete all as specified and as directed
Supply only PVC pipe 1/2 " bore with plastic elbow of existing length
S&F 6mm thick wooden ply of size 3’x6’, water proof, for fixing of desert coolers / window ACs, etc. complete all as specified and as directed
Supply only MS front show grill of existing type and make complete all as specified and as directed
Supply only plastic front show grill of existing type and make complete all as specified and as directed
Supply only wood wool cooler pad (set of three) having weight 500gm/set of existing type and size complete all as specified and as directed
Supply only aluminium fan blades for cooler motor fan of existing type and size complete all as specified and as directed
S&F cooler fan motor of capacity 1/10HP, single phase AC 240V 3 speed suitable for dessert coolers including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F angle iron stand for desert coolers made out of angle iron 40x40x5mm of existing size with four legs including leg supports duly painted with 2 coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed
S&F in repairs MS sheet side panels of dessert coolers as per exisiting type of size 700x700mm including fixing arrangement, drilling, bolting, etc. complete all as specified and as directed
M&L for taking down carefully geysers of any capacity any make after disconnecting electric & water connections for carrying out repairs by replacing worn out / damaged parts / components, refixing the same after carrying out necessary repairs to original place and re-connecting electric & water supply lines complete all as specified and as directed Note: Replaced parts / components shall be measured under respective items hereunder
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting entirely geysers 25/35litres with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide primer complete all as specified all as directed
S&F in repairs heating element 1.5kW for 35litres capacity geyser ISI marked complete all as specified and as directed
S&F in repairs heating element 2kW for 50litres capacity geyser ISI marked complete all as specified and as directed
S&F in repairs heating element 3kW for geyser ISI marked complete all as specified and as directed
S&F in repairs thermostat switches of geyser of any capacity complete all as specified and as directed
S&F in repairs indicating bulb (Red/Green) of geysers complete all as specified and as directed
S&F in repairs air release valve suitable for 25/35litres capacity geysers of existing type and make complete all as specified and as directed
S&F in repairs stop valve, 15mm dia conforming to IS: 5312 (Part-1) 2004, swing type with matching flanges, nuts bolts, rubber washers, etc. for geysers complete all as specified and as directed
M&L for taking down geysers 25/35litres capacity, taking out the copper tank, brazing and welding, etc. to check leakages in tank and refixing and connecting up nuts bolts, rubber washers, etc. for geysers complete all as specified and as directed
S&F in repairs 15mm PVC connections, 600mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F in repairs rubber gasket for inner tank 25litres capacity of existing type complete all as specified and as directed
S&F in repairs storage water tank of 25litres capacity suitable for geysers of existing type complete all as specified and as directed
S&F in repairs fusible lead nut for safety pressure of existing type complete all as specified and as directed
M&L for replacing base assembly (syphon system) of existing type with rubber gasket suitable for 25litres capacity geysers including disconnecting mains and taking down the geyser complete all as specified and as directed
M&L for replacing riser pipe, header pipe, footer pipe including coating suitable for solar water heaters of existing capacity and type including testing on completion complete all as specified and as directed
M&L for replacing storage water tank 300litres capacity suitable for solar water heaters of existing type including cladding with cladding glass wool and GI powder coated sheet, connecting to and including hose pipe 25mm bore, checking leakages and welding to check leakages, cleaning the tank and testing on completion complete all as specified and as directed
M&L for taking down split type AC 1.5TR / 2TR capacity for required servicing, cleaning of cooling coil, air filters / plasma filters, etc. (indoor unit), condenser, compressors, fan motor, etc. (outdoor unit) with vacuum cleaner and cleaning solution, checking the serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: Spares / components replaced shall be measured and paid separately under respective items herein
M&L for taking down window type AC 1.5TR / 2TR capacity for required servicing, cleaning of cooling coil, air filters / plasma filters, etc. condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking the serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed Note: Spares / components replaced shall be measured and paid separately under respective items herein
Supply only running capacitor 36MFD
Supply only running capacitor 45MFD
Supply only starting capacitor 100-120MFD
Supply only starting capacitor 120-150MFD
Supply only starting relay 1022/1622
Supply only starting relay 2000
Supply only plastic louvers (front panel) for window/split type ACs 1.5/2T
Supply only thermocol sheet 40x20inch and 20mm thick
Supply only thermostat switch 2059/2064/2054
Supply only plastic condenser fan blade for split type AC 1.5/2T
Supply only plastic condenser fan blade for window type AC 1.5/2T
Supply only copper filter, double capillary, pencil type
Supply only wiring kit for AC window/split type 1.5/2T
Supply only remote control for split AC 1.5/2T of existing make
Supply only main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2T
Supply only suction and discharge valve set for split AC 1.5/2T
S&F in repairs copper Flair nut of size 1/2 inch all as per existing and as approved complete all as specified and as directed
S&F in repairs copper Flair nut of size 1/4 inch all as per existing and as approved complete all as specified and as directed
S&F in repairs insulated piping of split AC units as per existing and as approved complete all as specified and as directed
S&F in repairs MS stand for outer unit of split AC .5/2TR as per the existing size duly fixed / bolted on wall with nuts, bolts and washers including all necessary drilling, welding, etc. at location as approved complete all as specified and as directed
M&L for taking down of split type AC 1.5/2TR capacity by disconnecting both the copper tubes from indoor and outdoor unit, duly storing of its refrigerant, carrying out minor brazing/welding in copper tubing, etc. then duly filling up refrigerant as per desired pressure, refixing in same or other location, making all electrical connections and testing on completion complete all as specified and as directed
S&F in repairs evaporator / cooling coil as per existing type, size and pattern suitable for 1.5/2T split type AC complete all as specified and as directed
M&L for removing / scrapping of old worn out paint from window AC units / outer unit of split ACs by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in window type AC units of capacity 1.5/2Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in split type AC units of capacity 1.5/2Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
Supply, installing, testing and commissioning of compressors of AC units in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed for the following types and capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
Split type air conditioner of capacity 1.5Ton
Split type air conditioner of capacity 2Ton
Wndow type air conditioner of capacity 1.5Ton
Wndow type air conditioner of capacity 2Ton
Supply, installing and testing of fan/blower motors of AC units, split type 1.5/2T in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, vacuuming the fins, etc. taking out the fan / blower motor, cleaning, removing dust / dirt, etc., around and replacing motor and finally put the rest back together and commissioning including disposing of old unserviceable motor complete all as specified and as directed for the following types and capacities: Notes: (i) Blower motors shall be from existing manufacturer / as approved by the GE (ii) Fan / blower motors shall bear a minimum guarantee of 5years and as given by manufacturers
Supply, installing and testing of condenser coils of AC units in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed for the following types and capacities: Notes: (i) Condenser coils shall be of existing manufacturer / as approved by the GE (ii) Condenser coil shall bear a minimum guarantee of 5years and as given by manufacturers
Window type air conditioner of capacity 1.5/2Ton
Split type air conditioner of capacity 1.5/2Ton
Supply, fixing and testing of cooling coils of AC units, split type air conditioner of capacity 1.5/2Ton in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable cooling coil complete all as specified and as directed for the following types and capacities: Notes: (i) Cooling coils shall be of existing manufacturer / as approved by the GE (ii) Cooling coil shall bear a minimum guarantee of 2 years and as given by manufacturers
Supply, installing and testing of fan motor / blower motors of AC units split type of capacity 1.5/2Ton in any location / position including disconnecting electrical mains, removing the clutter, grill, wires, vacuuming the fins, etc. taking out the fan / blower motor, cleaning, removing dust / dirt, etc., around and replacing motor and finally put the rest back together and commissioning including disposing of old unserviceable motor complete all as specified and as directed for the following types and capacities: Notes: (i) Fan / blower motors shall be from existing manufacturer / as approved by the GE (ii) Fan / blower motors shall bear a minimum guarantee of 5years and as given by manufacturers
M&L for charging refrigerant gas F-22/R-134A in window type / split type AC units of capacity 1.5/2Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
S&F copper pipe with all necessary brazing, welding, providing butt bolts and screws of required sizes, clamps, etc. including taking down old unserviceable copper pipes of any sizes / dia and disposing off complete all as specified and as directed for the following sizes:
M&L for collecting unserviceable voltage stabilizer of capacity 63 to 200kVA from site, transporting to workshop, disassembling the unit for locating the fault including checking the serviceability of electrical/electronic parts viz. circuits relays, etc. and repalcement of defective spare parts, re-assembling after making connections, testing by applying low and high voltage input to get correct output and transporting back the same to MES store yard complete all as specified and as directed Notes: (i) Cartage shall include both loading and unloading, etc. (ii) Replacement of defective spares / rewinding of transformers of voltage stabilizers will be measured & paid separately under respective itemshereunder
M&L for taking out burnt winding from transformers of voltage stabilisers 3kVA, cleaning with suitable cleaning agent, preparing the core, rewinding the transformer with super enameled copper wire of existing gauge including varnishing, heating, reinstalling and testing complete all as specified and as directed
M&L for taking out burnt winding from transformers of voltage stabilisers 4kVA, cleaning with suitable cleaning agent, preparing the core, rewinding the transformer with super enameled copper wire of existing gauge including varnishing, heating, reinstalling and testing complete all as specified and as directed
M&L for taking out burnt winding from transformers of voltage stabilisers 5kVA, cleaning with suitable cleaning agent, preparing the core, rewinding the transformer with super enameled copper wire of existing gauge including varnishing, heating, reinstalling and testing complete all as specified and as directed
M&L for disconnecting from mains and taking down for servicing water coolers, upto 150litres capacity including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions all as specified and as directed Note: Spares / parts / componenets reaplaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in these unit rates quoted
S&F company made new sealed compressor units for water coolers 40 to 150litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
S&F condensor fan motor of capacity 1/10 HP, 1/16HP single phase AC 220V suitable for water coolers of capacity 150litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
S&F condensor coil fins as per existing pattern suitable for water coolers of capacity 40 to 150litres including disconnecting the electric mains and taking out and disposing off the unserviceable fan motor and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
M&L for charging refrigerant gas F-22/R-134A in water coolers of capacity 150/40 litres including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
M&L for evaporator / cooling coil of water coolers of capacity 150/40litres, checking the serviceability, checking leakages of gas and rectifying same by welding, etc. and ensuring satisfactory working conditions complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to water coolers 40litres capacity with one coat of plastic paint over a coat of red oxide primer complete all as specified all as directed
S&F in repairs starting capacitor 80-100MFD complete all as specified and as directed
S&F in repairs running capacitor 25MFD complete all as specified and as directed
S&F in repairs drain hose pipe 40mm bore complete all as specified and as directed
S&F in repairs plastic condensor fan blade for motors 1/10 or 1/16HP complete all as specified and as directed
S&F in repairs plastic condensor fan blade for motors 1/32 or 1/35HP complete all as specified and as directed
S&F in repairs copper filter pencil type single/double capillary complete all as specified and as directed
S&F in repairs 15mm PVC connections, 900mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F stop vlave cast copper alloy screw down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm dia bore for water coolers complete all as specified and as directed
S&F in repairs taps self closing type suitabl for 40 to 150litres water coolers complete all as specified and as directed
S&F in repairs starting relays of existing size for water coolers complete all as specified and as directed
M&L for disconnecting from mains for servicing refrigerator / deep freezer of capacity 165 to 310litres, cleaning of cooling coil, condenser, compressors, with vacuum cleaner and cleaning solution including detecting of any leakage of gas, refilling if required, checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc. and checking serviceability of the unit for satisfactory working condition complete all as specified and as directed Note: Defective spares shall be replaced and will be measured and paid separately under relevant items herein
Supply only thermostat switch with knob suitable for refrigerators / freezers
Supply only starting relay 1/6HP open type with OLP suitable for refrigerators / freezers 200 to 310litres
Supply only starting relay 1/8HP open type with OLP suitable for refrigerators / freezers 200 to 310litres
Supply only copper filter single capilary pencil type suitable for refrigerators / freezers 200 to 310litres
Supply only door lock suitable for refrigerators / freezers 200 to 310litres
Supply only door switch suitable for refrigerators / freezers 200 to 310litres
Supply only interior light fitting suitable for refrigerators / freezers
Supply only door handle of existing design suitable for refrigerators / freezers
Supply only compartment glass suitable for refrigerators / freezers
S&F company made new sealed compressor units for refrigerators, 165 to 180litres capacity including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers
M&L for charging refrigerant gas F-22/R-134A in refrigerators 165 to 310litres capacity including taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed
Supply only capacitor 4MFD for desert cooler
S&F water lifting pump, heavy duty, single phase 240V single phase AC suitable for desert coolers of existing capacity including disconnecting the electric mains and taking out and disposing off the unserviceable pump and reconnecting the electric connections, etc. and testing on completion complete all as specified and as directed
M&L for earthing with galvanised steel earth wire electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth wire 4sqmm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
M&L for earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth strip of size 32x6mm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
Notes for serial item Nos. 354 & 355: (i) The cost of GI earth continuity wire with GI pipe 40mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
The Rahul Vig
NAVREET CONSTRUCTION
M/S Sonu Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .