Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹41.0 L+₹1.9 L (4.87%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹41.1 L+₹2.0 L (5.05%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹42.7 L+₹3.6 L (9.16%)Rejected-Finance H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹42.9 L+₹3.7 L (9.53%)Rejected-Finance 6146 HIRA CHOWK SIRKI BAZAR BATHINDA PB 151005 | BATHINDA | PUNJAB | 151005 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
7 Jan 2025, 6:00 pmClosed
GARRISON ENGINEER
DADWARA KOTA RAJASTHAN 324002
COMPREHENSIVE MAINT OF SEWAGE LINES, MANHOLES, SEPTIC TANKS, SOAKAGE WELLS IN NORTHERN SECTOR, SITA ENCLAVE AND CENTRAL SECTOR UNDER AGE B/R I AREA AT MIL STN KOTA
2024_MES_688405_1
8900E8
Open Tender
Civil Works
Item Rate
334 days
MIL STN KOTA
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE Kota
₹86,000
Yes
5 Feb 2025
12 Dec 2024
14 Jan 2025
12 Dec 2024
7 Jan 2025
26 Dec 2024
Amount
M & L for taking out/cleaning of contaminated sewage water including accumulated sludge in any form and other forgien materials etc viz sediment sand ash, grease, fibre roots or vegetation etc from existing septic tanks of any capacity/size including inlet/outlet chambers by manually or by mechanically eqpt or by way any other suitable means and cleaning by using fresh water completely as directed and including removing sludge will be transported in covered carrier vehicles and dumped out side MoD land wherever approved by local Govt authority, complete all as specified and directed. Note :- The septic tank shall be dewatered first and cubic contents of remaining sludge shall only be measured. However, rate quoted by tenderer shall deemed to be included in the quotated rate.
Clearing /cleaning of temporarily blocking of existing sewage line (beyond 1st manholes) dia of pipe 100/150mm bore of any description under ground of any depth with suitable wooden plugs/gunny bags and cleaning the same by pumping rodding with wire, rounding or mechanical rodding by jet pressure rodding set mounted on sewage cleaning tractor/trucks and removing the/broken bottles/wastes and other any type of blockage materials from manhole to manhole of sewage pipe lines and including cleaning completely by using fresh water, complete all as specified and directed. Note :- The contractor himself arrange all T & P with pressure jetting machine with 5000 Ltrs water tank as required for the aforesaid item. However, rate quoted by tenderer shall deem to be included in the quotated rate.
Clearing /cleaning of temporarily blocking of existing sewage line (beyond 1st manholes) dia of pipe 200/300mm bore of any description under ground of any depth with suitable wooden plugs/gunny bags and cleaning the same by pumping rodding with wire, rounding or mechanical rodding by jet pressure rodding set mounted on sewage cleaning tractor/trucks and removing the/broken bottles/wastes and other any type of blockage materials from manhole to manhole of sewage pipe lines and including cleaning completely by using fresh water, complete all as specified and directed. Note :- The contractor himself arrange all T & P with pressure jetting machine with 5000 Ltrs water tank as required for the aforesaid item. However, rate quoted by tenderer shall deem to be included in the quotated rate.
M & L for cleaning of underground sewage line of 150mm bore excavation and breaking & minimum two length and removing blockage laying new pipes rejoining with old pipes including haunching new pipes with PCC 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate in all situation where cleaning is not possible also including excavation & earth work complete all as specified and directed.
All Ditto as per item No 4.00 (here-in-before) but dia of pipe 200mm bore of any description complete all as specified and directed.
M & L for making arrangment for bypass to nearest manhole or line to keep sewage flow continous providing required necessary T&P such as protable pump set, flexible hose pipe etc., all as required for pump set flexible hose pipe upto 60 meter distance, complete all as specified and directed.
De sludging and cleaning / clearing of existing manholes (excluding 1st manhole) of any size any shape, exceeding 0.5m but not exceeding 1.00m deep by removing sludge, waste, debries etc from manholes and including cleaning completely by using fresh water & including disposing/ removing of all sludge, waste debries etc will be transported in covered carrier vehicles and dumped out side MoD land wherever approved by local Govt authority, complete all as specified and directed. Notes for Srl Item Nos. 07 & 08 :- During desludging & cleaning manholes of existing sewage line necessary arrangement for continuous flow of line through bypass system by pump/Municipal corpon truck, tractor for avoid blockage of all line and rate for the same deemed to be included in the quotated rate.
De sludging and cleaning / clearing of existing manholes (excluding 1st manhole) of any size any shape, exceeding 1.0m but not exceeding 2.0m deep by removing sludge, waste, debries etc from manholes and including cleaning completely by using fresh water & including disposing/ removing of all sludge, waste debries etc will be transported in covered carrier vehicles and dumped out side MoD land wherever approved by local Govt authority, complete all as specified and directed.
M & L for clearing/cleaning of temporarily all blockage of WC, Bath, Kitchen, WHB, Traps, soil wast/vent pipe (vertical or laid in trenches/floor of any type/size), existing sewage line upto 1st manhole pits and 1st manhole of any section/depth/any situation by way of cleaning /dislodging manholes by using any type of manualy or mechanically or by way of any other suitables means & including foreign materials from manholes, traps, pits where required and as directed by Engineer-in-Charge and keeping the sewage system upto 1st manhole functional in perfect condition & including final drop out from upto 1st manhole (working in final condition with taking precautationary measures equipment shall be provided as required or applicable) complete all as specified and day to day directions of Engineer in Charge. Note :- (i) The contractor shall be rectified all complaints on daily basis even on sunday and holiday to attend emergency complaints alongwith requisite T & P as required for Job. No extra payment shall be admissible for working on Sunday/Holiday. (ii) Labours (Safaiwala/sweeper) provided under this item shall exclusively by deputed on the work for cleaning of blockage as described in this item. The persons to be depolyed for this item shall not be deputed for any other work mentioned in BOQ. (iii) Each and every complaint shall be rectified within 24 hours of handing over of complaint slip, failing which a panel recovery of Rs. 50.00 per complaint for each 12 Hrs shall be imposed on the contractor which shall be recovered from any dues of contractor outstanding with the department. No claim whatsoever shall be entertained on this account in future. Complaints Register shall be maintained by the Contractor and will be put up daily basis to the Engineer-in-Charge for verification.
Cutting and grubbing of bushes grass and tree surrounding, septic tank, soakage well, manholes, gully trap and sewage line alignment etc for making workable condition and levelling of ground around the manholes, sewage line and removing the waste material to a distance exc 50m but not exc 500m and clearing the site complete all as directed by Engineer in Charge. Note :- (i) All requisite T & P as required for aforesaid item and safety shall be arranged and made available by the contractor. However, rate quoted by tenderer shall deemed to be included in the quotated rate. (ii) All safety measures for workmen to do work shall be provided by the contractor. (iii) Any other existing Govt. assets (like electric cables, water pipe line, storm water drain, boundary walls etc) are damages during the site clearance/excavation contractor should be repair at same time without any delay and no extra amount on this account is admissible. (iv) Bidder shall note understand that the rate quoted by him and in r/o of site clearance items shall be deemed included in quoted rate and no extra on this account is admissible.
Taking out and removing of old manhole cover and frames of any type/grating on rain water gutter including re-fixing the same after raising man hole with brick work of height 3 brick course wall of outer size 120x120 cm to 150x150cm in CM 1:4 and fixing the old manhole cover or fixing new cover complete all as specified and directed.
Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc & removing rubbish off the premises complete all as specified and directed.
Demolition of brick work/stone boulder masonry, built in CM incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for and removing rubbish from premises, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and pavings not exc 15cm thick (below or above ground level) and removing all the rubbish from premises, complete all as specified and directed.
Demolition and breaking up drain pipes 150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Demolition and breaking up drain pipes 200mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Excavation in trenches n.exc 1.50 m wide and n.exc 1.50 m in depth for foundation, laying pipe lines, manholes etc., n.exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Excavation in trenches n.exc 1.50 m wide and exceeding 1.50m but n.exc 3.0 m in depth for foundation, laying pipe lines, manholes, etc., n.exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in soil, including spreading, levelling, waterning and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated materials (soil) n. exc 50m and deposited where directed at a level n. exc 1.5m above the starting point, complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:2:4, type B-2 using 40 mm graded stone aggregate as in surface channels and drains, finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in surface channels and drains, finished even and smooth without using extra cement complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in landings, cover slabs (for manholes etc), chajjas, water troughs, mangers, shelves and similar articles with plain faces & including necessary Formwork, and shifting to different places and set in CM 1:4, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where dirtected and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
M&L brick work with pulverized fuel Ash-lime bricks (Fly ash bricks - modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:4, complete all as specified and directed.
M&L walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6, including finishing the joint, flush as the work proceeds complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40mm to face stones and dressing or face beds and joints, as specified, of random rubble walling, uncoursed or bourght upto courses complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces, finished fair and even complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm bore of pipe complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 200mm bore of pipe complete all as specified and directed.
M&L for 150 mm bore grade 'A' salt-glazed stoneware drain pipes laid in trenches and jointed with cement mortar 1:1 and tested complete all as specified and directed.
M&L for 200 mm bore grade 'A' salt-glazed stoneware drain pipes laid in trenches and jointed with cement mortar 1:1 and tested complete all as specified and directed.
S&F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured tee) with access door complete all as specified and directed.
S&F in renewal of 100 mm bore cast iron soil, waste and vent pipes (sand cast), in any length with or without ears with cement joints, fixed on walls, complete all as specified and directed.
S&F in renewal of 100 mm bore cast iron soil, waste and vent pipes (sand cast), in any length with or without ears with cement joints, laid in trenches or in floor, complete all as specified and directed.
S&F in renewal of 75 mm bore cast iron soil, waste and vent pipes (sand cast), in any length with or without ears with cement joints, fixed on walls, complete all as specified and directed.
S&F in renewal of 75 mm bore cast iron soil, waste and vent pipes (sand cast), in any length with or without ears with cement joints, laid in trenches or in floor, complete all as specified and directed.
S&F 100 mm bore cast iron tee/bends (any radius), with access door complete all as specified and directed.
S&F 100 mm cast iron cowl complete all as specified and directed.
S&F in renewal of 110mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints, fixed to walls for rain water pipe, complete all as specified and directed.
S&F in renewal of 110 mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F in renewal of 75 mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F in renewal of 75mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints, fixed to walls for rain water pipe, complete all as specified and directed.
S&F PVC (SWR) bend 110 mm bore, any radius with access door, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) bend 110 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) bend 75 mm bore, any radius with access door, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) bend 75 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) 75 mm bore, junction single, (Single T) equal or unequal with access door, complete all as required and as directed.
S&F PVC (SWR) 110 mm bore, junction single, (Single T) equal or unequal with access door, complete all as required and as directed.
S&F PVC (SWR) 110 mm bore, branch piece, single (Single Y) equal or unequal with access door, complete all as required and as directed.
S&F stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 75mm bore pipe complete all as required and as directed.
S&F stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 100/110mm bore pipe complete all as required and as directed.
M&L TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
BLANK
M & L for MS hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts ; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L cutting existing manholes for connecting new drain (for 150 mm bore pipe), making good to pipe and rendering, cutting out existing benching for forming branch channel (half round or 3/4 section) in cement concrete 1:2:4 type B-1 or smooth finishing and reforming benching as required complete all as specified and directed.
M&L cutting existing manholes for connecting new drain (for 200 mm bore pipe), making good to pipe and rendering, cutting out existing benching for forming branch channel (half round or 3/4 section) in cement concrete 1:2:4 type B-1 or smooth finishing and reforming benching as required complete all as specified and directed.
M/S R.K. Builders & Developer (BID ID -3202652)
ANNAPURNA ENTERPRISES (BID ID -3203202)
Aditya Enterprises (BID ID -3202985)
B B BUILDERS (BID ID -3202621)
Ganesh Contruction (BID ID -3202894)
TARKESHWAR DASS CONSTRUCTION COMPANY (BID ID -3203253)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .