Executive Engineer STD Ganderbal
Office of Executive Engineer STD Ganderbal
Electrical Works for Augmentation of Receiving Station Ajas from 9 MVA to 11.3 MVA
2020_PDD_98420_1
STD/GBL/07 of 2020-21
Open Tender
Electrical Works
Turn-key
30 days
Bandipora
Refer SBD, REC Drawing, DDUGJY specification
7 documents required · 7 mandatory
₹1,000
Executive Engineer STD Ganderbal
₹17,269
4 Jul 2020
16 Jun 2020
1 Jul 2020
16 Jun 2020
30 Jun 2020
17 Jun 2020
16 Jun 2020 - 30 Jun 2020
Amount
Outdoor equipment for Augmentation of Receiving Station Ajas from 1x5+1x4 MVA to 1x6.3 + 1x5 MVA
Installation, testing and commissioning of Power transformer 6.3 MVA 33/11 K V ONAN Copper wound,out door type conventional transformer oil filled with OLTC and all accessories including LT and HT connections.
Installation, testing and commissioning of 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type)
Supply, Installation, testing and commissioning of 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer/Porcelain) gap less. (As per DDUGJY specification document enclosed)
Supply, installation, testing and commissioning of 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) (As per DDUGJY specification document enclosed)
Supply, installation, testing and commissioning of 33 kV Isolator without Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) (As per DDUGJY specification document enclosed)
Supply, installation, testing and Commissioning of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) (As per DDUGJY specification document enclosed)
Supply, fixing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (As per DDUGJY specification document enclosed)
Indoor equipments for Augmentation of Receiving Station Ajas from 1x5+1x4 MVA to 1x6.3 + 1x5 MVA
Installation, programming , testing and commissioning of 33kV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port
Installation, testing and commissioning of 11 kV VCB Panel Board (12 kV, 1250A, 25 kA,Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port. (1+1 no. VCB)
Supply, Installation, commissioning and testing of 11 kV 3-Core XLPE 300 mm² armoured, FRLS
Supply, Installation, commissioning and testing of 11 KV cable kit ( indoor type) Heat shrinkable
Supply, Installation, commissioning and testing of 11KV Cable kit (Out door type) Heat shrinkable
Supply, laying, testing and commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS (As per DDUGJY specification document enclosed)
Supply, laying, testing and commissioning of 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. (As per DDUGJY specification document enclosed)
Supply, laying, testing and commissioning of 4 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. (As per DDUGJY specification document enclosed)
Supply, Installation, commissioning and testing of 7.5 KVA Servo Transformer
Supply and fixing of Lugs, Ferrules etc.
M/S KALHANA ASSOCIATES
M/S NEW EXTREME ENGINEERING
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .