Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | ₹8.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹8.1 L+₹7,635.60 (0.95%)Rejected-AOC | ₹8.1 L+₹7,635.60 (0.95%) | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | GIJO IDICULLA L1 | SIBIRAJ JOSEPH L2 |
|---|---|---|---|---|---|
| 1.00DETAILED ESTIMATE | |||||
| 1.00 | OD342534/2025-2026:Supplying, laying and jointing 315 mm PVC Pipe for sewer line to line and grade in trenches up to a depth of 1.50m jointing with solvent cement and filling in with water and testing the line to the required pressure excluding earth work excavation etc. using pipe @ 6kgf/cm2 etc. complete. | 100.6 | metre | 3,884 ₹3,90,730.4 Lowest | 3,900 ₹3,92,340 |
| 1.00 | OD283850/2025-2026: Constructing sewer manhole of size 80x80 inside and depth not exceeding of 120 cm with 20cm thick reinorced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab 120x120x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification | 12 | each | 25,955 ₹3,11,460 Lowest | 26,400 ₹3,16,800 |
| 1.00 | OD283849/2025-2026:od43788/2020_2021 : Constructing sewer manhole of size 80x80 inside and depth not exceeding of 90 cm with 20cm thick reinorced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab 120x120x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification | 4 | each | 20,740 ₹82,960 Lowest | 20,900 ₹83,600 |
| 1.00 | OD344059/2025-2026:Constructing sewer manhole of size 50x50 inside and depth not exceeding of 90 cm with 15cm thick reinforced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab80x80x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification | 2 | each | 9,677 ₹19,354 Lowest | 9,700 ₹19,400 |
Tender Value
₹8.0 L
EMD Value
₹20,115
Closing Date
16 Mar 2026, 2:00 pmClosed
Assistant Executive Engineer
O/o the Assistant Executive Engineer,Special Buildings Subdivision, Gandhinagar
The provisions included in the estimate are constructing new manholes, laying 315 mm pipelines and allied works.
2026_PWD_845108_1
PWD/BLDG/TR/1369/2026_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
180 days
Govt. Medical College Kottayam, Gandhinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,775
₹20,115
9 Jun 2026
7 Mar 2026
18 Mar 2026
7 Mar 2026
16 Mar 2026
7 Mar 2026
DETAILED ESTIMATE
OD342534/2025-2026:Supplying, laying and jointing 315 mm PVC Pipe for sewer line to line and grade in trenches up to a depth of 1.50m jointing with solvent cement and filling in with water and testing the line to the required pressure excluding earth work excavation etc. using pipe @ 6kgf/cm2 etc. complete.
OD283850/2025-2026: Constructing sewer manhole of size 80x80 inside and depth not exceeding of 120 cm with 20cm thick reinorced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab 120x120x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification
OD283849/2025-2026:od43788/2020_2021 : Constructing sewer manhole of size 80x80 inside and depth not exceeding of 90 cm with 20cm thick reinorced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab 120x120x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification
OD344059/2025-2026:Constructing sewer manhole of size 50x50 inside and depth not exceeding of 90 cm with 15cm thick reinforced cement concrete side walls using 1:2:4 using 20 mm b.s. and C.C 1:4:8 15cm thick using 40 mm broken stone for bottom and plastering inside with 1:3 ,12 mm two coat and forming channel with C.C 1:2:4, 20 mm broken stone and providing R.C.C cover slab80x80x7.5 cm with C.C 1:1.5:3, 20 mm broken stone using reinforcement etc .complete as per standard specification
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1427072.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
viewsbd.pdf
Tender Documents • 1.63 MB
BOQ_1427072.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .