Loading…
Loading…
Tender Value
₹8.3 L
EMD Value
₹9,000
Closing Date
21 Sept 2026, 6:00 pmClosed
Executive Engineer Ukai Division No.1, Ukai
Providing and Erecting to High mast Tower for Right Side Area At Juj Dam
342849
E Tender Notice No.18 of 2026-27
Open
Electrical - All
Works
Tapi
9 documents required · 9 mandatory
₹900
Executive Engineer Ukai Division No.1,Ukai
₹9,000
7 Sept 2026
7 Sept 2026
7 Sept 2026
21 Sept 2026
7 Sept 2026
Name of Work : Providing and Erecting to high mast Tower for Right Side Area at Juj Dam
Qty Item rate Per Amount
Supplying and erecting Flexible PVC insulated multi strand
Rupees NinetySeven Paise
1 120 multi core 1.1 kv grade ISI marked copper wires of 97.97 Mtr
NinetySeven Only
following size to be erected as directed.
(h) 2.50 Sq.mm 3 core round PVC sheathed
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges
(B) Flood Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage
(vii) 200 to 250 watts cat-III Ea
Rupees Nine Thousand
20 9196.05 One Hundred NinetySix
Paise Five Only
Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
3 confirms to IS :8828 in existing box having following
(b) 40 Amp. Cat.- III Rupees Seven Hundred Ea
3 736.29 ThirtySix Paise TwentyNine
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench /
pipe of following size of cables
(a) 4 core 16 Sq. mm Rupees One Hundred Mtr
436 184.83 EightyFour Paise
EightyThree Only
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 80 mm having 80-200 Micron galvanising, Inner
pipe dia of 40 mm having 200-250 Micron galvanising,
connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications
with chamber and heavy duty cover (A)(approved make
5 OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by
agency and officer Incharge has to ensure the value of
earthing resistane mentioned in test Certificate) & having
back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long
time Necessary test report must be submitted by Agency.
[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr Rupees Five Thousand
4 Back filling compound - 1 Nos. of Bag of 15 Kgs. Add 1% 5842.85 Eight Hundred FourtyTwo Ea
labour cess Paise EightyFive Only
Making trench in Hard Murrum / Tar Road of suitable width
of 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same Rupees SeventyFour Paise
and making the surface as normal ground. SeventyFour Only
(B) If additional machinery like hammer driller or JCB use Rupees Three Hundred
7 90 357.54 FiftySeven Paise FiftyFour Mtr
Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming to
IS 14930 II )with necessary connecting accessories of
8 same material at required depth in existing trench for laying
of cable. below ground / road surface for enclosing cable.
Rupees SixtyTwo Paise
390 (A)50 mm outer dia 62.62 Mtr
Solder less crimping type Aluminium lugs conforming to
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals with
9 brass/cadmium plated nut bolts in an approved manner.
(C) 16/25 Sq.mm. Rupees Fifteen Paise Ea
Supplying & erecting approved make time switch with single Ea
pole airbreak contacts suitable for 230 V.15/16A.complete
with self starting motor driven clock ‘ON’ &’ OFF’ automatic Rupees Two Thousand
10 2 arrangement at any predetermined time during each 24 2354.31 Three Hundred FiftyFour
hours,With nickel cadmium rechargeable battery backup Paise ThirtyOne Only
erected as directed.
Supplying, erecting, testing, commissioning approved make
M.S. Polygonal High Mast Pole having following general
(a) Polygonal Section fabricated from M.S. Plate confirms
BSEN 10025 & Hot deep galvanized minimum 65/86 micron
(as per IS 2629 /1985) Lantern carriage with ring and rubber
lines for erection of luminaries of suitable site.
(b) Maximum telescopic section not more than four
(c) Double drum gear pipe motorized winch with 6mm dia
S.S. Rod (For 16 mtr and above size)
11 (d) Approved make L.E.D. aviation light = 1 No. Lightening
arrestor = 1 No. with necessary wiring of 2.5 sq.mm 5 core
ISI copper cable Unarmoured.
(e) Bottom most section suitable for mounting reversible
motor and switchgears having door not more than 1400mm
x 300mm with waterproof gasket & hinges & locking
(f) Pole structure comprises suitable size of reversible
motor, cable and necessary switchgears with control panel.
[4] High Mast 16 Mtr. TOP A/F 150 Mm, BOTTOM A/F
Mm, No. of Sec. No. - 2, Bottom Thickness - 4 mm, Top
Sec. - 3 mm, Size Base Plate - dia.630 mm x 20 mm thick, Rupees Two Lakh Twelve
2 Foundation Bolt Size M24 x 870 mm, Qty - 12 Nos., 212104.04 Thousand One Hundred Ea.
Suitable for mounting Fitting of Light - 10 Nos. Four Paise Four Only
Providing and erecting AC-3 duty 3 pole power contactor
with 2 NO & 2 NC aux contacts complete with 415V/220V
12 operating coil suitable for (L&T, BCH,T.C., Siemens, C&S
(B) for 40 A rating Rupees Four Thousand Ea
NinetyThree Paise
I/We am/are willing to carry out the work at …………………………………………………………………% above/below percent (shouldbe written
in figured and words) of the estimated rates mentioned above. Amount of my/our tender works out as under.
Estimated amount Estimated amount
Put to tender Rs……………. Put to tender Rs…………….
Deduct : ……. % above RS…………… Deduct : ……. % Below RS……………
Net Rs…………… Net Rs……………
*(Please strike out whitchever is not applicable).
Note 1 – All work shall be carried out as per public works department handbook and other specification of Division ot as directed.
Note 2 – All the columns is schedule should be filled in ink and the total of the entries in the last column should be struck by the
contractor under his signature.
Note 3 – Rates quoted include clearance of site (prior commencement of work and at its close ) in all respects and hold good for work
under all conditions, site, moisture,weather etc.
Note 4 – To be continued on additional sheets, if found necessary.
Note 5 - The rates quoted by the Contractor must be inclusive of all taxes prevailing on due date of bid submission except GST.
However, any subsequent changes in the tax structure by Government after due date of bid submission will be compensated (+/-) on
availability or submission of actual documentation. Contractor will have to intimate Engineer regarding changes occurred in the tax
structure after bid submission. If the contractor fails to provide such information and if any financial obligation may arise due to change
in tax structure, same will be recovered from the contractor. GST will be paid separately on the bills. Hence, it is the responsibility of the
contractor to pay the GST to the concerned Authority.
Deputy Executive Engineer Executive Engineer
Electrical Sub Division Ukai Division No.1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD HM Tower RS Juj.pdf
SCH B 3.pdf
2.0 Special condion Electric (5).pdf
Make List 3.pdf
5.0 Approved make list 2013 2014 Part 1.pdf
6.0 Approved make list 2013 2014 Part 2.pdf
E-Tender Notice No.18 of 2026-27.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .