Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Fee/PreQual/Technical/Finance DINADAYAL ASHRAM PARA AGARTALA TRIPURA W 799003 | AGARTALA | WEST TRIPURA | TRIPURA | 799003 | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹2.1 L+₹11,590 (5.90%)Admitted-Fee/PreQual/Technical/Finance SIDDHI ASHRAM AGARTALA TRIPURA WEST | AGARTALA | WEST TRIPURA | TRIPURA | 799003 | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | S D COOL TECH L1 | Binapani Stores L2 |
|---|---|---|---|---|---|
| 1.00 | Providing of Split type High wall with capacity not less than 6,000 Kcal/ hr or 24000 BTU/hr or 7000 W) split A.C machine operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must be of pure copper) not less than 3 (Three) Star rating (latest Standard),operates on Single Phase 230 volt, 50Hz, AC Supply maximum current drawn 11.0 ampere, including supply of 3.0 Mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (Four) core electrical connecting cable, Remote control unit in/c batteries,16 amps power top etc complete, capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. | 3 | No | 59,500 ₹1,78,500 Lowest | 65,000 ₹1,95,000 |
| 2.00 | Standard installation, testing and commissioning of High Wall Split type Air Conditioning machine /Stand (Vertical) Air Conditioning machine including necessary cement plastering of holes, vaccumising of Refrigerant line & Cooling coil prior to Gas charging within the range of minus 28 to minus 30 micron | 3 | No | 2,000 ₹6,000 Lowest | 2,000 ₹6,000 Lowest |
| 3.00 | Fabrication of M.S. platform for placement of condensing unit( outdoor unit) by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 3 | No | 1,400 ₹4,200 Lowest | 2,000 ₹6,000 |
| 4.00 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line with installation and necessary wiring between between indoor and outdoor units beyond the standard length as per direction of the Engineer-in-Charge. | 9 | Mtr | 850 ₹7,650 | 50 ₹450 Lowest |
| 5.00 | Providing and connecting Electric Control cables between MCB to indoor/outdoor.
A) 3 core minimum 2.5 Sq. mm Copper Cable | 10 | Mtr | 1 ₹10 Lowest | 50 ₹500 |
Tender Value
₹2.1 L
EMD Value
₹4,169
Closing Date
28 Sept 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer Mechanical Division
Providing Installation commissioning of three Nos Split type Hi wall air Conditioning System at newly renovated old SDM office for Court of SDJM Civil Judge Jr Divn Teliamura Khowai Tripura
2026_CEPWD_77039_1
73_EE_DNIeT_MECH_202627
Open Tender
Electrical Works
Works
30 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹4,169
28 Oct 2026
21 Sept 2026
28 Sept 2026
21 Sept 2026
28 Sept 2026
21 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing of Split type High wall with capacity not less than 6,000 Kcal/ hr or 24000 BTU/hr or 7000 W) split A.C machine operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must be of pure copper) not less than 3 (Three) Star rating (latest Standard),operates on Single Phase 230 volt, 50Hz, AC Supply maximum current drawn 11.0 ampere, including supply of 3.0 Mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (Four) core electrical connecting cable, Remote control unit in/c batteries,16 amps power top etc complete, capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. | 3 | No | - | - |
| 2 | Standard installation, testing and commissioning of High Wall Split type Air Conditioning machine /Stand (Vertical) Air Conditioning machine including necessary cement plastering of holes, vaccumising of Refrigerant line & Cooling coil prior to Gas charging within the range of minus 28 to minus 30 micron | 3 | No | - | - |
| 3 | Fabrication of M.S. platform for placement of condensing unit( outdoor unit) by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 3 | No | - | - |
| 4 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line with installation and necessary wiring between between indoor and outdoor units beyond the standard length as per direction of the Engineer-in-Charge. | 9 | Mtr | - | - |
| 5 | Providing and connecting Electric Control cables between MCB to indoor/outdoor.
A) 3 core minimum 2.5 Sq. mm Copper Cable | 10 | Mtr | - | - |
stage.html
html • 0.02 MB
finance_78416.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.10 MB
DNIT.pdf
Tender Documents • 3.02 MB
BOQ_78416.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .