The Chief Officer, Padra Municipality, Padra
Bid Documents for Water Body Rejuvenation project of Govindpura Pond including Five Year Operation and Maintenance Period (SWAP-II) under Amrut 2.0 Scheme for Padra Nagarpalika at Padra, Dist. Vadodara.Second Attempt
281612
2025-26 second attempt
Open
Civil - All
Vadodara
15 documents required · 15 mandatory
₹14,160
The Chief Officer, Padra Municipality, Padra
₹5.6 L
27 Feb 2026
27 Feb 2026
27 Feb 2026
25 Mar 2026
27 Feb 2026
Sr No. Description Estimated Cost
SCHEDULE-B1 DEWATERING,DESILTING & LAND CLEARING
SCHEDULE-2 EARTH FILLING AT GOVINDPURA
SCHEDULE-3 CONSTRUCTION WORK OF TOE WALL
SCHEDULE-4 CONSTRUCTION WORK OF INLET BOX DRAIN
SCHEDULE-5 CONSTRUCTION WORK OF COMPOUND WALL,
SCHEDULE-6 CONSTRUCTION WORK OF PATHWAY & RAILING
SCHEDULE-7 CONSTRUCTION WORK OF SECURITY CABIN
SCHEDULE-8 CONSTRUCTION WORK OF DRINKING WATER FACILITY
SCHEDULE-9 PROVIDING AND LAYING OF 2000 MM DIA R.C.C. NP4 PIPE DRAIN
SCHEDULE-10 PROVIDING,SUPPLYING AND LAYING OF 600 MM DIA RCC NP-3 PIPE
SCHEDULE-11 HORTICULTURE SERVICES AT GOVINDPURA
SCHEDULE-12 CONSTRUCTION WORK OF PUMP ROOM
SCHEDULE-13 DRILLING OF TUBE WELL 250 MM DIA BY D. R. METHOD & 300 MM DIA
PIPE WITH 27.5 H. P. PUMP
SCHEDULE-14 SUPPLYING, ERECTING & COMMISSIONING OF STREET LIGHT WITH LED
SCHEDULE-15 DEVLOPEMENT OF CHILDREN PLAY AREA AND PLAYING EQUIPMENT
SCHEDULE-16 CONSTRUCTION WORK OF SHOPS.
SCHEDULE-17 O & M COST FOR 5 YEARS INCLUDING MATERIAL AND MANPOWER
I/We am/are willing to carry out the work at… % above/below percent (Should be written in figures and
words) of the estimated rate mentioned above. Amount of my/our tender works out as under Estimated
amount put to tender Estimated amount put to tender Deduct………% below Add………% Above
In words In words………………….
The 18% GST will be Paid Separately for the tender rate shown in the Schedule B.
The Contractor shall exhibit a board with detailed specification and details of work as directed by the
Engineer‐In‐ Charge for which no extra payment shall be made.
Signature of Contractor Signature of Chief Officer
PADRA NAGARPALIKA PADRA
DEWATERING,DESILTING & LAND CLEARING OF GOVINDPURA POND AT PADRA
Qty. Description Unit Amount
1 9262.00 Dewatering by pumping set of required
HP/Hr capacity including temporary platform
carting pumping at site and fixing the
same in position including all accessories,
and fuel and labour etc. complete.
2 6100.00 Excavation for foundation in sand,gravel,
Cmt clay soft soils and murrum etc.including
shoring, strutting dewatering as
necessary and disposing of the excavated
stuff as direcd.(A) Depth upto 3.0 M. and
lead upto 100m for 10 Cum.
3 0.90 Clearing and grubbing road land including
Heca. uprooting rank vegetation grass
bushes,shrubs,sapling and trees girth up
to 300 mm removal of stumps of trees
cut earlier and disposal of unserviceable
materials(A) By manual means in area of
SBD SECTION-7 BILL OF QUANTITIES-550
PADRA NAGARPALIKA PADRA
EARTH FILLING AT GOVINDPURA POND AT PADRA.
Qty. Description Unit Amount
1 6407.81 Filling in Foundation & plinth with
Cmt murrum of selected soil layers of 20 cm.
thickness including watering, ramming,
consolidating dressing etc complete.
2 12600.00 Earth Work Embakement including
Cmt. breaking clods, dressing with all lead and
lift (Including watering and Consolidation)
From Borrow area 0.5 Km lead &
Watering of earth work as directed.
SBD SECTION-7 BILL OF QUANTITIES-551
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF TOE WALL AT GOVINDPURA POND AT PADRA
Qty. Description Unit Amount
1 864.00 Excavation for foundation in Loose or
Cmt. soft soil 1.5 mt. Depth including sorting
out and stacking of useful materials and
depositing of the excavated stuff for all
the leads and lift etc. complete as directed
by Engineer-in-charge.
2 173.00 Excavation for foundation in Loose or
Cmt. soft soil from depth 1:5 mt. to 3.0 mt.
including sorting out and stacking of
useful materials and depositing of the
excavated stuff for all the leads and lift etc.
complete as directed by Engineer-in-charge.
3 272.00 Filling with available excavated earth in
Cmt. between walls and plinth in layer not
exceeding 20cm. In depth including
consolidating ramming, watering in true
line and level etc. complete as directed by
Engineer-in-charge.
4 86.50 Collecting, carting and Stacking Under size
Cmt. metal (40 mm to 63 mm. Size) at site of
work in difrent stacks over through
required including cost of filling measure
boxes of standard sizes, including cost of all
taxes, octroi loading, unloading charges of
vehicles, shifting charges of excess material
unloaded at one place to other place to be
used for the same site and stacking with all
lead and carting etc, complete.
SBD SECTION-7 BILL OF QUANTITIES-552
5 30.50 Collecting, carting and Stacking Stone
Cmt. Dust/bindage of very fine size for road at
site of work in all different stackes over
through out the length of road or where
ever required including cost of all taxes,
octroi, loading unloading any charges of
excess materials, loading at one place to
other place to be used for the same site
and stacking with all lead and lift and
carting etc. complete.
6 86.50 Spreading the stone aggregate for rolling
Cmt. and W.B.M. including filling the interstices
to required camber and gradient (excluding
spreading of Blindage)(ii) 40mm to 63mm
size aggreagates (H.B.)
7 30.50 Spreading blindage or road crust filling the
Cmt. gaps in metal and leveling to camber and
gradient as directed.(i) Stone Dust
8 108.00 Providing and laying cement concrete 1:3:6
Cmt. (1 Cement : 3 Course sand : 6 Broken stone
aggregates 40 mm nominal size) and curing
complete excluding cost of form work in (A)
Foundation and Plinth.
9 540.00 Providing Toe wall for dry stone pitching in
Cmt. uncourased rubble masonary with had
stone of approved quality in cement.
Mortar 1:5 including curing etc. complete.
(more than 10 ton)
10 35.00 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Beams having
any cross section area for all floors.
11 54.00 Providing and laying controlled cement
Cmt concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in coping.
SBD SECTION-7 BILL OF QUANTITIES-553
12 8050.00 Providing TMT Bar FE 500D reinforcement
Kgs. for R.C.C. work including bending, binding
and placing in position complete upto floor
13 192.00 Filling in Foundation & plinth with sand
Cmt under floors including watering, ramming,
consolidating and dressing etc. complete.
14 192.00 Screened gravel 12mm size
SBD SECTION-7 BILL OF QUANTITIES-554
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF INLET BOX DRAIN AT GOVINDPURA POND , PADRA
No. Qty. Description Unit Amount
1 795.00 Excavation for foundation in Loose or soft
Cmt. soil 1.5 mt. Depth including sorting out and
stacking of useful materials and depositing
of the excavated stuff for all the leads and
lift etc. complete as directed by Engineer-in-
a)0.00 to 1.50 M. depth 120.01 Cmt.
2 795.00 Excavation for foundation from depth 1:5
Cmt. mt. to 3.0 mt. Depth including sorting out
and stacking of useful materials and
depositing of the excavated stuff up to
meter lead. (a) Loose or soft soil.
3 961.50 Filing available excavated earth (excluding
Cmt. rock) in trenches plinth sides of foundations
etc. in layers not exceeding 20cm. In depth
consolidating each deposited layer by
remming and watering.
4 175.00 Collecting, carting and Stacking Under size
Cmt. metal (40 mm to 63 mm. Size) at site of
work in difrent stacks over through required
including cost of filling measure boxes of
standard sizes, including cost of all taxes,
octroi loading, unloading charges of
vehicles, shifting charges of excess material
unloaded at one place to other place to be
used for the same site and stacking with all
lead and carting etc, complete.
SBD SECTION-7 BILL OF QUANTITIES-555
5 44.00 Collecting, carting and Stacking Stone
Cmt. Dust/bindage of very fine size for road at
site of work in all different stackes over
through out the length of road or where
ever required including cost of all taxes,
octroi, loading unloading any charges of
excess materials, loading at one place to
other place to be used for the same site and
stacking with all lead and lift and carting etc.
6 175.00 Spreading the ston aggregate for rolling and
Cmt. W.B.M. including filling the interstices to
required camber and gradiant (excluding
sprading of Blindage )(ii) 40 mm to 63 mm
size aggreagates.(H.B.)
7 44.00 Spreading blindage or road crust filling the
Cmt. gaps in metal and leveling to camber and
gradiant as directed (ii)
8 79.50 Providing and laying cement concrete
Cmt. 1:4:8(1 Cement, 4 coarse sand, 8 graded
stone aggregates 20mm nominal size) and
curing complete excluding cost of formwork
in Foundation and Plinth 2747.21 Cmt.
9 Providing and laying controlled cement
concrete M-200 and curing complete
excluding the cost of formwork and
reinforcement of reinforced concrete work
a. 180.16 -- do -- for R.C.C Base Slab 3942.22 Cmt.
b. 150.00 -- do -- for R.C.C Vertical Wall 4485.51 Cmt.
c. 141.00 -- do -- for R.C.C Top Slab 4460.86 Cmt.
10 58900.00 Providing TMT Bar FE 500D reinforcement
Kgs. for R.C.C. work including bending, binding
and placing in position complete upto floor
two level 77.29 Kg.
SBD SECTION-7 BILL OF QUANTITIES-556
11 500.00 Providing and applying 10 mm thick smooth
Smt. cement plaster in single coat of fair side of
brick/concrete walls for interior plastering
for G.F. upto floor two level in C.M.(1:3) (1
cement, 3 sand) including finishing even and
smooth with floating coat of neat cement
slurry including scaffolding curing etc.
complete as directed by Engineer-in-charge.
12 432.00 Providing and fixing M. S. grill cover with M.
Kgs. S flats at required spacing and frames
alround, Square or round bars fixed with
round headed bolts and nuts or by screws,
including oil painting with one coat of
primer of approved quality and brand and
two coats of synthetic enamel oil paint etc.
complete as directed by Engineer-in-charge.
13 Providing Formwork of ordinary timber
plankings so as to give a rough finished
including centering, shuttering, struting and
propping etc. height of propping and
centering below supporting floor to ceiling
not exceeding 4.0 Mt. and removal of the
same for cast in situ reinforced concrete and
plain concrete work.
a. 1500.00 For Vertical Wall 238.06 Smt.
b. 310.00 For Slab 260.88 Smt.
14 60.00 Providing and laying rubble stone pitching
Smt. 22.50cm thick including preparing the
surface and filling interstices with sand
including pointing on pitching in C.M. 1:3
including curing, cost of all materials and
labor as directed on site etc.
SBD SECTION-7 BILL OF QUANTITIES-557
15 2.00 Filling in Foundation & plinth with sand
Cmt under floors including watering, ramming,
consolidating and dressing etc. complete.
16 2.00 Screened gravel 12mm size
SBD SECTION-7 BILL OF QUANTITIES-558
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF COMPOUND WALL, AT GOVINDPURA POND AT PADRA
Item Qty. Description Total Unit Amount
1 1452.00 Excavation for foundation up to 1:5 mt.
Cmt. Depth including sorting out and stacking
of useful materials and depositing of
the excavated stuff up to 50 meter lead.
2 253.00 Excavation for foundation from depth 1:5
Cmt. mt. to 3.0 mt. Depth including sorting out
and stacking of useful materials and
depositing of the excavated stuff up to
meter lead. (a) Loose or soft soil. 133.05 Cmt.
3 1123.00 Filing available excavated earth (excluding
Cmt. rock) in trenches plinth sides of foundations
etc. in layers not exceeding 20cm. In depth
consolidating each deposited layer by
remming and watering. 133.65 Cmt.
4 169.00 Providing and laying cement concrete 1:4:8
Cmt. (1-Cement : 4-fine sand : 8-graded birck
aggregates 40 mm nominal size) and curing
complete excluding cost of form work in (a)
Foundation and plinth. 2726.96 Cmt.
5 263.50 Providing and Laying controlled cement
Cmt. concrete M-250 and curing complete,
including the cost of formwork but
excluding the cost of reinforcement for
reinforced concrete work in Column
footings. 4779.32 Cmt.
6 56.00 Providing and laying controlled cement
Cmt. concrete M-250 and curing complete
including the cost of formwork But
Excluding the cost of reinforcement for
reinforced concrete work in Column upto
Plinth Level having any cross section area. 6893.25 Cmt.
SBD SECTION-7 BILL OF QUANTITIES-559
7 70.00 Providing and Laying controlled cement
Cmt. concrete M-250 and curing complete,
including the cost of formwork but
excluding the cost of reinforcement for
reinforced concrete work in Columns having
any cross section area upto floor two level.
8 93.50 Providing and laying controlled cement
Cmt. concrete M-250 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Ground Beam
having any cross section area. 5875.17 Cmt.
9 18.00 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork and
excluding the cost of reinforcement of
reinforced concrete work in
-- do -- for Coping
51240.00 Providing TMT Bar FE 500D reinforcement
Kgs. for R.C.C. work including bending, binding
and placing in position complete upto floor
11 88.00 Brick work using common burnt building
Cmt. bricks having crushing strngth not less than
35 Kg./cm2 in super structure for Ground
Floor in C.M. (1:6) (1 Cement, 6 fine sand)
racking out joints curring etc. complete
directed by Engineer-in-charge. 4121.55 Cmt.
12 27.00 Providing and laying and fixing 50 mm thick
Smt. expansion joint by hydro cell semi rigid UV
resistance with high performance laminated
closed cell polythene foam joint filler in
sheet foam as directed, etc. complete.
SBD SECTION-7 BILL OF QUANTITIES-560
13 1823.00 Providing 15 mm. thick cement plaster in
Smt single coat on Rough (similar) side of single
or half brick walls for interior plastering
upto floor two level and finished even and
smooth in. (II) cement mortar 1 : 4 (1
cement : 4 sand) Extra over item 58 to
for finishing with a floating coat of neat
cement slurry. (upto 10 ton) 220.61 Smt.
14 1823.00 Finishing wall with water proof exterior
Smt emulsion apex paint of on wall surfaces
(two coats) to give an approved brand and
manufacture and of required slope evan
shade after throughly brushing the surface
to remove all dirt and remains of loose
powered materials. etc completed. 117.40 Smt.
15 150.00 Steel work, welded in built up sections
Q framed work including cutting, hoisting,
fixing in position and applying a priming
coat of red lead paint. (A)In beams and
joists, channels angles Tees, flats, with
connecting plates or angle cleats as in main
and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the
16 763.28 Painting two coats (including priming coat)
Smt. on new steel and other metal surface with
enamel paint, brushing, interior to give an
even shade including cleaning the surface
an even shade including cleanicn the surface
of all dirt, dust and other foreign matter.
17 1032.00 Chain link 2 10 x 10 gauge (Galvanised)
Smt. 256.78 Smt.
SBD SECTION-7 BILL OF QUANTITIES-561
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF PATHWAY & RAILING AT GOVINDPURA POND AT PADRA.
Item Qty. Description Total Unit Amount
1 1620.00 Excavation for foundation up to 1:5 mt.
Cmt. Depth including sorting out and
stacking of useful materials and
depositing of the excavated stuff up to
2 396.00 Filing available excavated earth
Cmt. (excluding rock) in trenches plinth sides of
foundations etc. in layers not exceeding
20cm. In depth consolidating each
deposited layer by remming and
3 339.00 Providing and laying cement concrete
Cmt. 1:4:8 (1-Cement : 4-fine sand : 8-graded
birck aggregates 40 mm nominal size) and
curing complete excluding cost of form
work in (a) Foundation and plinth.
4 328.50 Brick work using common burnt clay
Cmt. building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:6 (1-
Cement : 6 -fine sand)(B) Conventional
5 165.50 Brick work using common burnt clay
Cmt. building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:6 (1-
Cement : 6 -fine sand)(B) Conventional(
Extra for brick work in superstructure
above plinth level upto floor two level (B)
SBD SECTION-7 BILL OF QUANTITIES-562
6 18.50 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork and
excluding the cost of reinforcement of
reinforced concrete work in
-- do -- for Coping
7 73.50 Providing and Laying ordinary cement
Cmt. concrete 1:2:4 (1- Cement 2- coarse sand
: 4- graded stone aggregates 20 mm
nominal size) and finishing smooth with
curing etc. complete including the cost of
formwork but excluding the cost of
reinforsement for R.C.C work in (ii) Slabs
having more than 8 cm and upto
8 9200.00 T.M.T. Bars
Kgs. Providing TMT Bar FE 500D reinforcement
for R.C.C. work including bending, binding
and placing in position complete upto
floor two level
9 1417.50 Providing 15mm thick cement plaster in
Smt single coat on Rough (Similar)side of
single or half brick walls for interior
plastering upto floor two level and
finished even and smooth in (i) Cement
mortar 1:3 (1-cement:3-sand)) Extra over
items 58 to 64 for finishing with a floating
coat of neat cement slurry.
10 13790.00 Providing and fixing M.S. grills of required
Kgs. pattern to frames of gril etc. with M.S.
flats at required spacings and frame
alround, square or round bars with round
headed bolts and nuts or by screws. (B)
ORNAMENTAL GRILL
11 1417.50 Finishing wall with water proof exterior
Smt emulsion apex paint of on wall surfaces
(two coats) to give an approved brand
and manufacture and of required slope
evan shade after throughly brushing the
surface to remove all dirt and remains of
loose powered materials. etc completed.
SBD SECTION-7 BILL OF QUANTITIES-563
12 1103.00 Painting two coat (Including priming
Smt coat) on new steel and other metal
surface with enamel paint, brushing,
interior to give an evel shade including
cleaning the surface an even shade
including cleanicn the surface of all dirt,
dust and other foreing matter.
13 483.00 Filling in foundation and plinth with brick
Cmt Bats Chhara in layers of 20cm. thickness
including watering, remming and
consolidating etc. complete.
14 95.00 Rough Kotach stone Slab. 25 mm thick
15 983.00 Providing and fixing pre-cast Rubber Dye /
Smt steel Dye inter locking concrete block
60mm thick with grade of concrete M300
pnumatic compressed / vibrated
mechanically and as per approved design
Confirming to IS 15658 : 2006 including
35 mm Sand layer for levelling and filling
the joint with sand in proper line and
level as per guidlines of IRC : SP 63-2018
16 1205.00 Providing and fixing pre-cast concrete
Rmt kerb stone of gray cement based concrete
block 30cm length,30cm height and 15cm
thick of M200 grade concret as per
approved design and including excavation
for fixing in proper line and level,filling
the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
17 1050.00 Providing cement vata (10cm. x 10 cm.
Rmt size) quarter round in cement mortar 1:1
including neat cement finishing, watering
18 90.00 PVC SWR pipes IS 13592 for Drain -
SBD SECTION-7 BILL OF QUANTITIES-564
18 199.00 providing & laying Accupressure Pathway
Smt with 100mm thick C.C 1:2:4 Layeron
150mm thick P.C.C 1:3:6 Laying With
Screen gravel of 20 nominal size and
coarse Aggregat of 10 to 20 mm size to be
fixed on C.C 1:2:4 Layer to suite the
walking on pathway complete with
allkinds of Labour ,material ,Carting
,Chrges As Direct on Site by Engineer in
SBD SECTION-7 BILL OF QUANTITIES-565
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF SECURITY CABIN AT GOVINDPURA POND AT PADRA
Qty. Description Unit Amount
1 23.40 Excavation for Foundation upto 1.5 m. Depth including
Cmt. sorting out and stacking of useful materials and disposing
of excavated stuff upto 50 Meter lead (A) (loose or soft
2 3.90 Excavation for base footings upto depth 1.5 m. including
Cmt. sorting out and disposing of the excavated material upto
50 m lead (loose or soft soil) 133.05 Cmt.
3 21.00 Filling available excavated earth (excluding Rock) in
Cmt. trenches. Plinth, sides of foundations etc. in layers not
exceeding 20cm. In depth consolidating each disposited
layer by ramming and watering.
4 3.60 Filling in foundation and plinth with murrum or selected
Cmt. soil in layers of 20cm thickness including watering,
ramming and consolidating etc. complete.
5 13.35 Carrying out plinth treatment to post construction/
Smt. existing structure by spraying chemical solution for
termite control treatment including labour and material
consistment with I.S.I specification. Using Chlordene and
chiorpurfiles 20 EC. As per 6131_paret-II consteration
weight one percent is recommended i.e. one litre 20 EC
chemical emulsion with 19 liter give 1% concrentration
inclusive of one litre chemical emulsion application at the
rate of 5 litre chemical/sqm of surface as recommended
6 3.30 Providing and laying cement concrete 1:4:8 (1- Cement : 4-
Cmt. coarse sand : 8- hand broken stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
7 0.75 Providing and laying cement concrete 1:3:6 (1 Cement :
Cmt. coarse sand : 6 hand broken stone aggregates 40 mm
nominal size) and curing complete excluding cost of form
work in (A) Foundation and plinth. ( upto 10 ton)
SBD SECTION-7 BILL OF QUANTITIES-566
8 2.90 Providing and Laying controlled cement concrete M-250
Cmt. and curing complete, including the cost of formwork but
excluding the cost of reinforcement for reinforced
concrete work in Column footings.
9 0.95 Providing and laying controlled cement concrete M-250
Cmt. and curing complete including the cost of formwork But
Excluding the cost of reinforcement for reinforced
concrete work in Column upto Plinth Level having any
cross section area.
10 1.15 Providing and Laying controlled cement concrete M-250
Cmt. and curing complete, including the cost of formwork but
excluding the cost of reinforcement for reinforced
concrete work in Columns having any cross section area
upto floor two level.
11 1.30 Providing and laying controlled cement concrete M-250
Cmt. and curing complete including the cost of formwork but
Excluding the cost of reinforcement for reinforced
concrete work in Ground Beam having any cross section
12 0.35 Providing and laying controlled cement concrete M-200
Cmt. and curing complete including the cost of formwork but
Excluding the cost of reinforcement for reinforced
concrete work in coping.
13 0.50 Providing and laying controlled cement concrete M-200
Cmt. and curing complete including the cost of formwork but
Excluding the cost of reinforcement for reinforced
concrete work in Lintel for all floor.
14 0.35 Providing and laying controlled cement concrete M-200
Cmt. and curing complete including the cost of formwork but
Excluding the cost of reinforcement for reinforced
concrete work in Chajja for all floor.
15 3.30 Providing and laying controlled cement concrete M-200
Cmt. and curing complete including the cost of formwork but
Excluding the cost of reinforcement for reinforced
concrete work in Slab having any thickness for all floors.
16 1.50 Providing and laying controlled cement concrete M-200
Cmt. and curing complete including the cost of formwork but
Excluding the cost of reinforcement for reinforced
concrete work in Beams having any cross section area for
SBD SECTION-7 BILL OF QUANTITIES-567
17 1223.00 T.M.T. Bars
Kgs. Providing T.M.T. Bar Fe 500. reinforcement for
R.C.C.work including bending, Binding and placing in
postion complete upto foor two level.(upto 10 ton)
18 1.15 Providing and Laying brick work using common burnt clay
Cmt. building bricks (Conventional)having crushing strength not
less than 35 Kg./Sq.Cm in foundation and plinth in Cement
Mortar. (1:6) (1 Cement : 6 fine sand)- (A)Conventional.
19 6.50 Brick work using common burnt clay building bricks having
Cmt. crushing strength not less than 35 kg./Sq.Cm. in
foundation and plinth in Cement Mortar 1:6 (1- Cement :
6 -fine sand)(B) Conventional ( Extra for brick work in
superstructure above plinth level upto floor two level (B)
20 1.90 Providing and fixing flush door shutters, soild core
Smt. construction with frame of first class hardwood with
crossboard and face veneer or plywood face panels,
including anodised aluminium butt hinges with necessary
screws. (B) Non-decorative type and block board core
anodised aluminium butt hinges in flush door shutters. (2)
21 5.80 Providing & fixing window having extruded aluminum
Smt. Colour Powder Coated section frame main outer size
95mm x 24mm x 1.17mm (of Jindal Section no:2459 @
wt.of 0.738 Kg/mt), horizontal Three track member size
92mm x 31.75mm x 1.30mm (of Jindal Section no:8688,@
Wt.1.07 Kg/mt), vertical member of size 92mm x
31.75mm x 1.50mm (of Jindal Section no:8933,@ Wt.
Kg/mt) with sliding shutters of horizontal member size
mmx18mm x1.29mm (of Jindal Section no:8947@ wt.of
0.456 Kg/mt), vertical member of size 40mm x 18mm x
1.29 mm (of Jindal Section no:8949 @ wt.of 0.456Kg/mt/
with 5 mm thick transparent bronze colour tinted float
glass with powder coated aluminum fittings and fixtures
and transparent silicon sealant glass fixing to frame as per
details etc .Complete for Window.
22 195.00 Providing and fixing M. S. grills of requried pattern to
Kgs. wooden frames of window etc. with M. S. flats at requried
spacings and frame alround square or round bars with
round headed bolts and nuts or by screws. (B) Plain Grills.
SBD SECTION-7 BILL OF QUANTITIES-568
23 7.65 Applying Priming Coat on new steel and other metal
Smt. surface by throughly cleaning, oil, grease and scoured with
brushes fine steel wood, scrapers and sand paper with
ready mixed priming paint brushing red lead and Painting
two coats with synthetic enamel paint, brushing to give an
even shade including cleaning the surface of all dirt, dust
and other foreign matter.
24 38.35 Providing 20 mm thick double coat mala cement plaster
Smt. on interior brick / concrete work for plastering comprising
of base coat of 12 mm thick cement plaster in cement
mortar (1 Cement : 4 coarse sand) in rough finishing and
mm thick top coat of cement mortar 1:2 (1 Cement :
Coarse sand) finished with trovel including scaffolding
curing etc. complete.
25 17.85 Providing 10mm thick cement plaster in single coat on
Smt. brick/concrete walls for interior plastering upto floor two
level and finished even and smooth in (ii) Cement mortar
1:4 (1-cement :4-sand) Extra over items 58 to 64 for
finishing with a floating coat of neat cement slurry. Extra
over items 58 to 71 for plastering on ceilings and sofits of
stairs upto floor two level instead of plastering on walls.
26 43.55 Providing and laying 15mm thick cement plaster in single
Smt. coat Rough (Similar) side of single or Half brick walls for
interior plastering upto floor two level and finished even
smooth in (i) C.M. (1 : 4) (1 -Cement : 4 -sand ) including
neat Cement slury finishing scaffolding, curing etc.
27 50.75 Providing 20 mm thick sand faced cement plaster on wall
Smt. upto height 10 meters above ground level consisting of
12mm thick backing coat of c.m 1:3 (1 cement : 3 sand )
and 8 mm thick finishing coat of c.m 1:1 (1 cement :
sand ) etc. complete.
28 38.35 Applying two coats of Birla (White Cement based) or Asian
Smt. acrylic lappy (putty) or equivalent & two coats of primer of
approved brand and manufacture on new wall surface to
give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign
matter and sand Papered smooth.
SBD SECTION-7 BILL OF QUANTITIES-569
29 99.75 Distempering (Three Coat) with oil bound washable
Smt. distemper of approved brand and manufacture and of
required shade on wall surfaces to give and even shade
over and including a primer coat with alkali resistance
primer of approved brand after throughly brushing the
surface free from other foreign matter and also including
preparing the surface even and sand papered smooth.
30 17.85 Distempering (Three Coat) with oil bound washable
Smt. distemper of approved brand and manufacture and of
required shade on Ceiling & Sloping Roof surfaces to give
and even shade over and including a primer coat with
alkali resistance primer of approved brand after throughly
brushing the surface to give and free from other foreign
matter and also including preparing the surface even and
sand papered smooth.
31 50.75 Finishing wall with Weather Proof Acrylic Exterior
Smt. Emulsion Paint on wall surface (two coats) to give and
required shape even shade and of approved brand and
manufacturer after throughly brushing the surface to
remove all dirts, and remians of loose powdered materials
32 13.35 Providing and laying 24"x24" Vitrified 8 mm to 10mm
Smt thick tiles flooring over 20 mm (average) base of cement
mortar 1:6 (1 Cement : 6 Coarse Sand) and jointed with
colour cement slurry including finished with flush pointing
and cleaning the surface etc. complete. For Flooring
33 1.40 Providing and laying 24"x24" Vitrified 8 mm to 10mm
Smt thick tiles flooring over 20 mm (average) base of cement
mortar 1:6 (1 Cement : 6 Coarse Sand) and jointed with
colour cement slurry including finished with flush pointing
and cleaning the surface etc. complete.For Skirting
34 8.80 Providing and laying polished Granite tiles 18 mm thick in
Smt risers of steps, skirting Dedo and pillars laid on 10 mm
thick cement mortar 1 : 3 (1 cement : 3 course sand) and
jointed with gray cement slurry mixed with pigment to
match the shade of slab including rubbing, polishing,
Moulding etc. complete. For Flooring, Doors & Windows
Add Electrical As per Sub Estimate
SBD SECTION-7 BILL OF QUANTITIES-570
PADRA NAGARPALIKA PADRA
ELECTRIFICATION INSTALLATION IN IN SECURITY CABIN AT GOVINDPURA POND AT
SR DESCRIPTION QTY RATE AMOUNT
1 Point wiring for Light / Bell with 2-1.5 sq.mm &
earthwire of 1.5 sq.mm (Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multistrand copper
wires, in following type of pipe to be erected concealed
in/ on surface on wall/ceiling complete with 6A Modular
type switch / bell push & accessories and earth continuity
of following type, erected on PVC / Metallic box, single
mounting base frame covered with textured/metallic
front plate modules erected on / in wall / ceiling as per
pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete. Cat.III
2 Point wiring for FAN with 2-1.5 sq.mm & earthwire of
sq.mm (Green) both are of .ISI marked 1.1 KV Grade
FRLS PVC insulated multistrand copper wires, in following
type of pipe to be erected concealed in / flushed on
wall/ceiling complete with 6A Modular type switch and
hum free EME four or more step type electronic fan
regulator with separately mounted and accessories with
earth continuity of following type erected on PVC /
Metallic box, single mounting base frame covered with
textured/metallic front plate modules erected on / in
wall / ceiling as per pipe erected. with necessary ceiling
rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete. Cat.III
3 Point wiring for Individual Plug with & earthwire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in following type
of to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected
on PVC / Metallic box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe 1.00 702.96
erected with following type of accessories.
[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete. Cat.III
SBD SECTION-7 BILL OF QUANTITIES-571
4 [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete. Cat.III
5 Point wiring for Looped Plug with 6A Modular type
switch & 5 pin socket erected on PVC / Metallic box,
single mounting base frame covered with textured / 2.00 257.55
metallic front plate modules erected on / in wall /
ceiling with following type accessories Cat. III
6 Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as directed
7 Providing & erecting PVC Corrugated Flexible Conduit
with required nos. of coupling, PVC bushes, Check-nuts
etc. complete of following sizes. (2) 25 mm
8 Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (a) with medium class Rigid PVC pipe and
accessories (b) 2 wire 2.5 sq. mm
9 Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of 10.00 112.11
green colour for earth continuity of following size (a) with
medium class Rigid PVC pipe and accessories (a) 2 wire
10 Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to
IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of 1.00 2445.21
same company of MCB to be used) suitable for (B)(iii)
Three phase 8 way SS Double door for horizontal single
11 providing and erecting Miniature circuit breaker single
pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in 2.00 112.11
existing box. confirming to IS 8828/1996 with ISI Mark
12 Providing & erecting 240 V MCB double pole switch for
motor & inductive load (C Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having
following capacity (B) 40 Amp. Cat.III
SBD SECTION-7 BILL OF QUANTITIES-572
13 Providing & erecting L.T. Current Transformer with bar
primary 50/5 to 1000/5 ratio 15 VA burden erected in
existing CRCA box duly secured with insulating materials
connected to the meter
14 Supplying and erecting approved make set of indicator
lamps of LED type lamp, lens cover, Bakelite holder
complete erected with necessary connections.
15 Supplying & erecting funnel type earthing having earth
plate of following size burred in specifically prepared
earth pit 3 mtr. below ground with 40 kg. charcoal and
salt with alternate layers of charcoal & salt, 20mm.dia.
G.I. pipe with Funnel with a wire mesh for watering &
bricks masonry block, C.I. Cover complete as per para
of IS 3043 with necessary length of double Galvanised
Iron / copper earth wire No 6 SWG bolted with lug to the
plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long
complete connected to the nearest switch gear with end
socket as per direction & duly tested by earth tester
confirming to IS (As per drawing) with following
(B) With 45 x 45 x 0.35 cms. C.I. earth plate 1.00 2568.43
16 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and
bolts if required. (e) One wire 6.00 sq. mm
17 Making trench in soft soil of suitable width of 90 cms
deep for laying cable or locating the fault all over the run
and backfilling the same and making the surface as
18 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for 5.00 51.51
following size of cables. (f) 2 to 4 core 25 Sq. mm
19 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for 5.00 247.45
following size of cables. (H) 3 & 1/2 core 240 Sq. mm
20 Solderless crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved 5.00 15.15
SBD SECTION-7 BILL OF QUANTITIES-573
21 Providing and erecting Approved make Ceiling fan with
double ball bearing ISI mark with condenser A.C.
23OV.50 c/s.1200 mm. sweep complete, canopy and
cms. down rod erected on existing hook or clamp with 1.00 1596.81
24/0.2 , 3 core flexible wire with earthing. [Make shall be
approved by Engineer in charge]
22 Providing 2.5mm.thick laminated acrylic sheet to cover
the fan hook or Fan box.
23 Providing Fan clamp of 30 x 5 mm flat of required length
& 10 mm M.S. Bolt & Nuts erected with necessary hook 1.00 98.98
of 10 mm M.S. Round Bar.
24 Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made
of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than 0.95,
THD < 15%,CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED LED driver
efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges
shown.) (A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet
25 Approved make C.F.L. Retrofit 13/15/18 Watt erected if
26 Supplying & erecting approved make low noise
decorative exhaust fan having square frame ABS body
with inbuilt lowers & square frame. 200mm with
SBD SECTION-7 BILL OF QUANTITIES-574
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF DRINKING WATER FACILITY AT GOVINDPURA POND AT PADRA
Item Qty. Description Total
1 26.95 Excavation for base footings upto depth
Cmt. m. including sorting out and disposing of
the excavated material upto 50 m lead
(loose or soft soil) 120.01 Cmt.
2 17.50 Filling available excavated earth (excluding
Cmt. rock) in trenches. plinth, sides of
foundations etc. in layers not exceeding
cm. in depth consolidating each disposited
layer by ramming and watering.
3 2.20 Filling in foundation and plinth with murrum
Cmt. or selected soil in layers of 20cm thickness
including watering, ramming and
consolidating etc. complete. 296.29 Cmt.
4 7.32 Carrying out plinth treatment to post
Smt. construction/existing structure by spraying
chemical solution for termite control
treatment including labour and material
consistment with I.S.I specification. Using
Chlordene and chiorpurfiles 20 EC. As per
6131_paret-II consteration weight one
percent is recommended i.e. one litre 20 EC
chemical emulsion with 19 liter give 1%
concrentration inclusive of one litre
chemical emulsion application at the rate of
5 litre chemical/sqm of surface as
recommended as per I.S.
SBD SECTION-7 BILL OF QUANTITIES-575
5 5.25 Providing and laying cement concrete 1:4:8
Cmt. (1- Cement : 4- coarse sand : 8- hand
broken stone aggregates 40 mm nominal
size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
6 4.10 Providing and Laying controlled cement
Cmt. concrete M-250 and curing complete,
including the cost of formwork but
excluding the cost of reinforcement for
reinforced concrete work in Column
footings. 4707.61 Cmt.
7 0.45 Providing and laying controlled cement
Cmt. concrete M-250 and curing complete
including the cost of formwork But
Excluding the cost of reinforcement for
reinforced concrete work in Column upto
Plinth Level having any cross section area.
8 1.00 Providing and Laying controlled cement
Cmt. concrete M-250 and curing complete,
including the cost of formwork but
excluding the cost of reinforcement for
reinforced concrete work in Columns having
any cross section area upto floor two level.
Rate Analysis No :-
9 1.15 Providing and laying controlled cement
Cmt. concrete M-250 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Ground Beam
having any cross section area. 5875.17 Cmt.
10 0.45 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in coping. 6218.57 Cmt.
SBD SECTION-7 BILL OF QUANTITIES-576
11 0.45 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Lintel for all
floor. 7854.77 Cmt.
12 0.20 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Chajja for all
floor. 6555.91 Cmt.
13 1.75 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Slab having any
thickness for all floors. 6661.96 Cmt.
14 1.25 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Beams having
any cross section area for all floors.
1400.00 Providing TMT Bar FE 500D reinforcement
Kgs. for R.C.C. work including bending, binding
and placing in position complete upto floor
two level 77.29 Kg.
16 1.65 Brick work using common burnt clay
Cmt. building bricks having crushing strength not
less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1- Cement : 6 -
fine sand)(B) Conventional
SBD SECTION-7 BILL OF QUANTITIES-577
17 7.34 Brick work using common burnt clay
Cmt. building bricks having crushing strength not
less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1- Cement : 6 -
fine sand)(B) Conventional (Extra for brick
work in superstructure above plinth level
upto floor two level (B) Conventional)
18 2.10 Providing and fixing flush door shutters,
Smt. soild core construction with frame of first
class hardwood with crossboard and face
veneer or plywood face panels, including
anodised aluminium butt hinges with
necessary screws. (B) Non-decorative type
and block board core anodised aluminium
butt hinges in flush door shutters. (2)
mm thick. 1829.74 Smt.
19 1.45 Providing & fixing window having extruded
Smt. aluminum Colour Powder Coated section
frame main outer size 95mm x 24mm x
1.17mm (of Jindal Section no:2459 @ wt.of
0.738 Kg/mt), horizontal Three track
member size 92mm x 31.75mm x 1.30mm
(of Jindal Section no:8688,@ Wt.1.07
Kg/mt), vertical member of size 92mm x
31.75mm x 1.50mm (of Jindal Section
no:8933,@ Wt. 1.06 Kg/mt) with sliding
shutters of horizontal member size
mmx18mm x1.29mm (of Jindal Section
no:8947@ wt.of 0.456 Kg/mt), vertical
member of size 40mm x 18mm x 1.29 mm
(of Jindal Section no:8949 @ wt.of
0.456Kg/mt/ with 5 mm thick transparent
bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to
frame as per details etc .Complete for
SBD SECTION-7 BILL OF QUANTITIES-578
20 90.00 Providing and fixing M. S. grills of requried
Kgs. pattern to wooden frames of window etc.
with M. S. flats at requried spacings and
frame alround square or round bars with
round headed bolts and nuts or by screws.
(B) Plain Grills 105.18 Kg.
21 38.80 Applying Priming Coat on new steel and
Smt. other metal surface by throughly cleaning,
oil, grease and scoured with brushes fine
steel wood, scrapers and sand paper with
ready mixed priming paint brushing red lead
and Painting two coats with synthetic
enamel paint, brushing to give an even
shade including cleaning the surface of all
dirt, dust and other foreign matter.
22 16.05 Providing 10mm thick cement plaster in
Smt. single coat on brick/concrete walls for
interior plastering upto floor two level and
finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) Extra over
items 58 to 64 for finishing with a floating
coat of neat cement slurry. Extra over items
58 to 71 for plastering on ceilings and sofits
of stairs upto floor two level instead of
plastering on walls.
23 40.20 Providing and Laying 20 mm thick sand face
Smt. cement plaster on Walls upto height of
mts. Above ground level consisting of
12mm thicjk backing coat of C.M 1:3 (1
Cement, 3 Sand ) and 8 mm thick finishing
coat of C.M 1:1 (1 Cement, 1 Sand) etc.
complete. 337.52 Smt.
SBD SECTION-7 BILL OF QUANTITIES-579
24 54.85 Distempering (Three Coat) with oil bound
Smt. washable distemper of approved brand and
manufacture and of required shade on wall
surfaces to give and even shade over and
including a primer coat with alkali
resistance primer of approved brand after
throughly brushing the surface to give and
even shade free from foreign matter and
also including preparing the surface even
and smooth. 101.75 Smt.
25 40.20 Finishing wall with weather proof exterior
Smt. emulsion paint on wall surface (two coats)
to give an required shape even shade after
thoroughly brushing the surface to remove
all dirt, and remains of loose powdered
materials.etc complete
26 14.70 Providing & Laying 24 "x 24" vitrified 8 mm
Smt. thick tile flooring over 20 mm ( average)
base of cement mortar 1:6 (1: cement :
coarse sand ) on new surface or fixing on
existing flooring by adhesive material
including dismentaling of existing flooring
and jointed with color cement slurry
including finised with flush pointing &
cleaning the surface etc. complete for
antiskit . (upto 10 ton) 1432.78 Smt.
27 9.50 Providing and laying white glazed tiles 6mm
Smt thick in skitring risers of steps and dado on
10mm thick cement plaster 1:3 (1 cement :
3 coarse sand) and pointing in white cement
jointed with white cement slurry.
SBD SECTION-7 BILL OF QUANTITIES-580
28 6.45 Providing and laying polished Granite tiles
Smt 18 mm thick in risers of steps, skirting Dedo
and pillars laid on 10 mm thick cement
mortar 1 : 3 (1 cement : 3 course sand) and
jointed with gray cement slurry mixed with
pigment to match the shade of slab
including rubbing, polishing, Moulding etc.
complete. For Flooring, Doors & Windows
29 7.50 Providing and laying China Mosaic type
Smt. water proofing treatment in terrace
including (a) Applying neat cement slurry
2.75 Kgs./Smt. of cement admix with water
proofing compound after cleaning the
surface (b) laying cement concrete using
brick bats 25mm to 100mm isze with 50%
cement mortar 1:5 (1 Cement : 5 Coarse
Sand) admixed mortar proofing compound
over 20mm thick layer of cement mortar
1:5 to required slope including rounding of
junctions of walls and slabs (c) after two
days of proper curing applying a second
coat of cement slurry (d) finished the
surface with 20mm thick cement mortar 1:4
(1 Cement : 4 Coarse Sand) and china
mosaic tiling & finally finishing the surface
with trowel with white cement slurry (e)
after finishing the whole terrace shall be
flooded with water for a period of two
30 3.50 Providing and fixing on wall face C.I. Rain
Rmt. water pipe including filling the joints with
spun yarn soaked in neat cement slurry and
cement mortar 1:2 (1- Cement : 2-fine sand)
(A) 75 mm dia 293.62 Rmt.
31 4.00 Providing and fixing 15mm. Dia C. P. Brass
Nos. screw down bib cock of approved quality
including fixing the same in pipeline and
testing etc. complete as directed by
Engineer-in-charge. 186.83 No.
SBD SECTION-7 BILL OF QUANTITIES-581
32 1.00 Providing and fixing 15mm. Dia C. P. Brass
No. stop cock of approved quality including
fixing the same in pipeline and testing etc.
complete as directed by Engineer-in-charge.
33 1.00 Providing and fixing gun metal chek or non
return fullway wheel valve. (A) 15 mm Dia.
34 4.00 Providing and fixing 100 mm dia sand cast
iron grating for gully, floor or nanhi trap.
35 2.00 Providing and fixing 150mm x 100mm size
No. "P" or "S" type square mount stone ware
gully trap with c. I. Grating brick masonry
chamber and water tight C. I. Cover with
frame of inside 300mm x 300mm size with
cutting and making good the walls floors
etc. complete as directed by Engineer-in-
charge. 1246.92 No.
36 1.00 Providing, laying and constructing brick
Nos. masonry chamber for underground C. I.
Inspection Chamber with Inside Dimension
600mm x 850mm x 450mm dedo for single
pipe line with bends having crushing
strength not less than 35Kg./Cm2 on C. M.
(1:5) (1 cement, 5 Sand) C. I. Cover with
frame (light duty) of 455mm x 610mm
internal dimension total weight of cover
with frame to be not less than 38.00 Kgs.
(Wt. of Cover 23 Kgs. and wt. of Frame
Kgs.) with R.C.C. top slab with 1:2:4 (1
cement, 2 Coarse sand, 4 graded stone
(Kapachi) ) foundation concrete 1:5:10 (1
cement, 5 Coarse sand, 10 brick bats of
40mm nominal size) inside plaster 15mm.
thick with C. M. 1:3 (1 cement, 3 Coarse
sand) finished smooth with a floating coat
of neat cement slurry on walls and bed
concrete including curing etc. complete as
directed by Engineer-in-charge.
SBD SECTION-7 BILL OF QUANTITIES-582
37 500.00 Supplying And fixing PVC water tank of ISI
Lits. make including delivery at site, supply and
fixing inlet, outlet, overflow, ballcock,
drainage sleeves of specific size, with
necessary neoprene gasket / packing /
washer, G.I.washer, and checknut etc.
compt as directed on terrace,loft,bathroom
etc in any height.The rate shall be include
for fixing additional accessories supplied by
supplyer accessories.
38 50.00 Providing, laying and jointing in true line
Rmt. and level 32 mm dia U.P.V.C. Pipe (SCH-40)
including fittings make as approved by
Engineer In Charge. Pipe shall be fixed on
the wall with the help of clamp at every two
meter c/c. or shall be concealed as directed
including necessary fittings etc. including
testing of pipe and joints and fixing the
same with adhesive solvent, including cost
of all materials.
39 20.00 Providing, laying and jointing in true line
Rmt. and level 25 mm dia U.P.V.C. Pipe (SCH-40)
including fittings make as approved by
Engineer In Charge. Pipe shall be fixed on
the wall with the help of clamp at every two
meter c/c. or shall be concealed as directed
including necessary fittings etc. including
testing of pipe and joints and fixing the
same with adhesive solvent, including cost
of all materials.
40 20.00 Providing, laying and jointing in true line
Rmt. and level 15 mm dia U.P.V.C. Pipe (SCH-40)
including fittings make as approved by
Engineer In Charge. Pipe shall be fixed on
the wall with the help of clamp at every two
meter c/c. or shall be concealed as directed
including necessary fittings etc. including
testing of pipe and joints and fixing the
same with adhesive solvent, including cost
of all materials.
SBD SECTION-7 BILL OF QUANTITIES-583
41 1.00 Providing & erecting water cooler having
No. storage capacity 150 Ltr. & cooling capacity
150 Ltr.per hour @ an ambient temp of 45˚
C. The outlet temp. of the water should
drop by 15˚C within a hour, The water
cooler should be comprising of hermetically
sealed compressor, fan motor, condensing
unit, water tank surrounded by evaporating,
coil, thermostats, relay etc.complete with
necessary inlet & outlet connection. The
body of water cooler will be made from
Stainless Steel.
42 1.00 Supplying & erecting 5 stage single reverse
No. osmosis water purification system with M.S.
powder coated frame, prefilter housing
with 'O' ring presediment filter GAC filter,
carbon filter suitable buster DC pump
capacity 80 psi, mention with 40 psi inline
type post carbon filter auto low & high
pressure switches with following size of
storage tank & LPH capacity & erected as
directed [C] 50 Ltr / Hr with 150 psi 2 nos
Add Electrical as Per Sub Estimate
SBD SECTION-7 BILL OF QUANTITIES-584
PADRA NAGARPALIKA PADRA
PROVIDING ELECTRIFICATION INSTALLATION IN IN WATER ROOM AT GOVINDPURA POND AT PADRA.
SR DESCRIPTION QTY UNIT RATE AMOUNT
1 Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires, in following type of pipe to be erected concealed in/ on
surface on wall/ceiling complete with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC / Metallic
box, single mounting base frame covered with textured/metallic front plate 5.00 Pt. 449.45
modules erected on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
2 Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper
wires, in following type of pipe to be erected concealed in / flushed on
wall/ceiling complete with 6A Modular type switch and hum free EME four
or more step type electronic fan regulator with separately mounted and
accessories with earth continuity of following type erected on PVC / Metallic 1.00 Pt. 638.32
box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
3 Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires,
in following type of to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected on PVC / Metallic
box covered with appropriate front plate modules erected on / in wall / 1.00 Pt. 702.96
ceiling as per pipe erected with following type of accessories.
[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
4 [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories erected flushed on 1.00 Pt. 711.04
wall/ceiling complete. Cat.III
5 Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic box, single mounting base frame covered with
textured / metallic front plate modules erected on / in wall / ceiling with
following type accessories Cat. III
6 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution & Clamps with 12.00 Mtr. 33.33
following dia of pipes, in approved manner as directed (b) 25 mm
7 Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts etc. complete of following sizes. (2) 25 mm 25.00 Mtr. 21.21
8 Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed in /flushed
on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated 25.00 Mtr. 82.82
stranded wire of green colour for earth continuity of following size (a) with
medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
9 Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of 10.00 Mtr. 112.11
green colour for earth continuity of following size (a) with medium class
Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
SBD SECTION-7 BILL OF QUANTITIES-585
10 Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house 1.00 Ea. 2445.21
appropriate nos. of MCBs.(The DBs should be used of same company of MCB
to be used) suitable for (B)(iii) Three phase 8 way SS Double door for
horizontal single phase outgoing
11 providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
12 Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity (B) 40 Amp. Cat.III
13 Providing & erecting L.T. Current Transformer with bar primary 50/5 to
1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with 1.00 Ea. 274.72
insulating materials connected to the meter
14 Supplying & erecting funnel type earthing having earth plate of following
size burred in specifically prepared earth pit 3 mtr. below ground with
kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I.
pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I.
Cover complete as per para 7.3 of IS 3043 with necessary length of double
Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate
and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the
nearest switch gear with end socket as per direction & duly tested by earth
tester confirming to IS (As per drawing) with following specification
(B) With 45 x 45 x 0.35 cms. C.I. earth plate 1.00 Ea. 2568.43
15 Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, 5.00 Mtr. 56.56
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required. (e) One wire 6.00 sq. mm
16 Making trench in soft soil of suitable width of 90 cms deep for laying cable or
locating the fault all over the run and backfilling the same and making the 5.00 Mtr. 55.55
surface as normal ground.
17 Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (e) 2 to 4 core 25 Sq. mm
18 Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (H) 3 & 1/2 core 240 Sq. mm
19 Solderless crimping type Aluminium lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved 5.00 Ea. 15.15
20 Providing and erecting Approved make Ceiling fan with double ball bearing
ISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete,
canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2 1.00 Ea. 1596.81
, 3 core flexible wire with earthing. [Make shall be approved by Engineer in
21 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan
22 Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt
& Nuts erected with necessary hook of 10 mm M.S. Round Bar.
23 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die
cast powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED
driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges
SBD SECTION-7 BILL OF QUANTITIES-586
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll 3.00 Ea. 535.30
24 Approved make C.F.L. Retrofit 13/15/18 Watt erected if required 1.00 Ea. 137.36
25 Supplying & erecting approved make low noise decorative exhaust fan
having square frame ABS body with inbuilt lowers & square frame. 200mm 1.00 Ea. 1366.53
with 1350RPM Cat.II
SBD SECTION-7 BILL OF QUANTITIES-587
PADRA NAGARPALIKA PADRA
PROVIDING AND LAYING OF 2000 MM DIA R.C.C. NP4 PIPE DRAIN FOR GOVINDPURA
POND, AT,PADRA.
Sr. Qty. Total Per Amount
1 320.00 Excavation for pipe line trenches for water
Cmt. supply, sewerage line, manhole etc. all with
shoring and struting if required as per required
gradient and line including safety provisions
using site rails and stacking excavated stuff
including up to all required lead cleaning the site
etc. complete for all lifts and strata as specified.
In all sorts of soil and soft murrum Upto 1.50 mt
2 256.00 Excavation for pipe line trenches for water
Cmt. supply, sewerage line, manhole etc. all
withshoring and struting if required as per
required gradient and line including
safetyprovisions using site rails and stacking
excavated stuff including up to all required
leadcleaning the site etc. complete for all lifts
and strata as specified. In all sorts of soil and soft
murrum 1.50 mt to 3.00 mt depth
3 70.00 Providing and supplying ISI Standard R.C.C.
Rmt. pipes(of Sulphate Resisting Cement) in standard
lengths of following
class and diameter suitable for either collar
joints or rubber ring joints including all taxes,
insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc.
complete. (IS - 458/ 1989 110 x 63 mm 90 x
Note : One collar should be supplied with each
full length plain ended RCC pipe, cost included in
rates below. One
rubber ring should be supplied with each full
length socketed pipe, cost included in rates
below.(2000 MM DIA NP4 PIPE )
2000 mm Dia NP4 21095.87 Rmt.
SBD SEC-7 BILL OF QUANTITIES-588
4 70.00 Lowering, laying and jointing R. C. C. pipes in C.
Rmt. M. 1:1 1/2 of following diameters in proper
position, grade and alignment at all level as
directed by Engineer-in-charge including
conveyance from stores to site of work, labour,
giving hydraulic testing as per ISI code
5 22.00 Providing and casting in situ mass cement
Cmt. concrete in 1:4:8 proportion using granite
quartzite trap metal of size 25 mm to 40 mm
including consolidation curing etc. complete.
6 3.00 Construction of Brick masonry chamber for pipe
Nos. drain including excavation, p.c.c. (1:4:8), c.c.
(1:2:4) benching, Brick Wall 350 mm thick, M-
200 coping, M-200 slab, 10 mm thick (1:3)
smooth plaster and including heavy duty FRC
frame and cover with all necessary labour and
material in all respect directed by EIC.
Inner Clear Dimensions 3.00 x 3.00 x 2.50 Avg.
depth 154546.09 No.
SBD SEC-7 BILL OF QUANTITIES-589
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF CHAMBER FOR 2000 MM DIA PIPE DRAIN SIZE 3.00 x
3.00 x 2.50Avg. Depth
SUB ESTIMATE FOR CHAMBER
Item Qty. Description Total Unit Amount
1 25.22 Excavation for base footings upto depth
Cmt. m. including sorting out and disposing of the
excavated material upto 50 m lead (loose or
(A) In loose or Soft Soil 120.01 Cmt.
2 34.96 Excavation for foundation for depth from
Cmt. m to 3.0 m including sorting out and stacking
of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(A) Loose
(A) In loose or Soft Soil 133.05 Cmt.
3 2.52 Providing and laying cement concrete 1:4:8
Cmt. (1- cement : 4-coarse sand : 8- hand broken
stone aggregates 40mm nominal size) and
curing complete excludig cost of formwork in
(A) foundation and plinth.
4 13.84 Brick work using common burnt clay building
Cmt. brick having crushing strength not less than
35 Kg/Sq.cm in foundation and plinth in
cement mortar 1:6 (1 cement : 6 fine sand)
(B) Conventional (upto 10 ton).
5 33.46 Providing 10 mm thick cement plaster in
Smt. single coat on brick/concrete wall for
interior plastering upto floor two level
finished even and smooth in (1:3) (1 cement
: 3 sand) curing etc. complete. 178.55 Smt.
SBD SECTION-7 BILL OF QUANTITIES-590
6 3.48 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but Excluding
the cost of reinforcement for reinforced
concrete work in Slab having any thickness
for all floors. 7402.29 Cmt.
7 521.99 Providing TMT Bar FE 500D reinforcement
Kgs. for R.C.C. work including bending, binding
and placing in position complete upto floor
two level 77.29 Kg.
8 12.00 Providing Cement Vata (10 cm x 10 cm size)
Rmt. quarter round in cement mortar 1:1
including neat cement finishing watering etc.
complete. 24.28 Rmt.
9 100.00 Providing and fixing M.S. Plain Grills of
Kg. required pattern to wooden frames of
windows etc. with M.S. Flats at required
spacing and frame alround, square or round
bars with round headed bolts and nuts or by
screws.For All Floors.(for Manhole Cover)
SBD SECTION-7 BILL OF QUANTITIES-591
PADRA NAGARPALIKA PADRA
PROVIDING,SUPPLYING AND LAYING OF 600 MM DIA RCC NP-3 PIPE DRAIN NEAR
GOVINDPURA POND AT PADRA
Qty. DESCRIPTION Per Amount
1 246.60 Excavation for pipe line trenches for water
Cmt. supply, sewerage line, manhole etc. all with
shoring and struting if required as per required
gradient and line including safety provisions
using site rails and stacking excavated stuff
including up to all required lead cleaning the
site etc. complete for all lifts and strata as
specified. In all sorts of soil and soft murrum
Upto 1.50 mt depth
2 137.00 Supplying and fixing reinforced concrete heavy
Rmt. duty non-pressure pipes with collars for culverts
carrying heavy traffic as per Indian Railway
Standard Specification including setting and
joining for pipes in C:M 1:2 watering and laying
(To level or slope) of I.S. Class NP-3 of following
internal dia meter. 600 mm Dia
3 173.00 Lowering, laying and jointing R. C. C. pipes in C.
Rmt M. 1:1 1/2 of following diameters in proper
position, grade and alignment at all level as
directed by Engineer-in-charge including
conveyance from stores to site of work, labour,
giving hydraulic testing as per ISI code 600 mm
SBD SEC-7 BILL OF QUANTITIES-592
4 5.00 Construction of Brick masonry chamber for pipe
Nos. drain including excavation, p.c.c. (1:4:8), c.c.
(1:2:4) benching, Brick Wall 350 mm thick, M-
200 coping, M-200 slab, 10 mm thick (1:3)
smooth plaster and including heavy duty FRC
frame and cover with all necessary labour and
material in all respect directed by EIC.
Inner Clear Dimensions 1.20 x 1.20 x 1.20 34511.92 No.
SBD SEC-7 BILL OF QUANTITIES-593
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF CHAMBER 600 MM DIA PIPE DRAIN SIZE
1.20x1.20x1.20 Avg. Clear Depth
Item Qty. Description Total Unit Amount
1 7.26 Excavation for base footings upto depth
Cmt. m. including sorting out and disposing of the
excavated material upto 50 m lead (loose or
2 1.84 Excavation for base footings upto depth
Cmt. m. including sorting out and disposing of the
excavated material upto 50 m lead (loose or
(A) In loose or Soft Soil 133.05 Cmt.
3 0.22 Providing and laying cement concrete 1:4:8
Cmt. (1 Cement, 4 coarse sand, 8 hand broken
stone aggregates 40mm. Nominal size) and
curing ecomplete excluding cost of
formwork in (A) Foundation and Plinth.
4 0.40 Providing and laying cement concrete 1:2:4
Cmt. (1- cement : 2-coarse sand : 4- graded stone
aggregates 20mm nominal size) and curing
complete excludig cost of formwork in (A)
Foundation and Plinth. 3656.13 Cmt
5 3.27 Brick work using common burnt building
Cmt. bricks having crushing strngth not less than
35 Kg./cm2 in super structure for Ground
Floor in C.M. (1:6) (1 Cement, 6 fine sand)
racking out joints curring etc. complete
directed by Engineer-in-charge. 4121.55 Cmt.
6 5.04 Providing 10mm thick cement plaster in
Smt. single coat on brick/concrete wall for
interior plastering upto floor two level
finishing even and smooth in 1:4 (1 cement,
4 sand). 143.66 Smt.
SBD SECTION-7 BILL OF QUANTITIES-594
7 0.83 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but Excluding
the cost of reinforcement for reinforced
concrete work in Slab having any thickness
for all floors. 4946.98 Cmt.
8 58.10 Providing TMT Bar FE 500D reinforcement
Kgs. for R.C.C. work including bending, binding
and placing in position complete upto floor
9 4.80 Providing Cement Vata (10 cm x 10 cm size)
Rmt. quarter round in cement mortar 1:1
including neat cement finishing watering etc.
complete. 24.28 Rmt.
10 80.00 Providing and fixing M.S. Plain Grills of
Kg. required pattern to wooden frames of
windows etc. with M.S. Flats at required
spacing and frame alround, square or round
bars with round headed bolts and nuts or by
screws.For All Floors.(for Manhole Cover
with frames) 105.18 Kg.
SBD SECTION-7 BILL OF QUANTITIES-595
PADRA NAGAR PALIKA, PADRA
HORTICULTURE SERVICES AT GOVINDPURA POND DEVEPLOPMENT AT PADRA
Sr. NO Item Discription Total Unit Rate Amount
1 Clearing jungle including uprooting of rank vegetation, grass, brush wood,
trees and saplings of girth up to 30 cm measured at a height of 1 m above
ground level and removal of rubbish up to a distance of 50 m outside the
periphery of the area cleared.
2 Good garden soil
Supplying and stacking of good earth at site including royalty and carriage
upto 5 km complete (earth measured in stacks will be reduced by 20% for
3 Cow dung manure
Supplying and stacking of well decayed cattle manure at site including royalty
and carriage upto 5 k.m. lead complete (cattle manure measured in stacks
will reduced by 8% for Payment)
4 Rough dressing the trenched ground including breaking clods.
5 Fine dressing of the ground
6 Mixing earth and sludge or manure in the required proportion specified or
directed by the Officer-in-charge
7 Spreading of sludge, dump manure and/or good earth in required thickness
as per direction of officer-in-charge (cost of sludge, dump manure and/ or
good earth to be paid separately)
8 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm
thickness of existing ground prepared with proper level and ramming with
required tools wooden and than rolling the surface with light roller make the
surface smoothen and light watering the same maintenance for 30 days or
more till the grass establish properly,as per direction of officer in charge
8.1 Supplying of healthy, disease-free Vetiver (Chrysopogon zizanioides)
plants/slips**, minimum height 20–30 cm with well-developed roots, at site
of work. Plants shall be transported carefully to avoid damage. Fixing shall
include making planting holes of suitable depth and spacing (generally 0.25 m
to 0.30 m c/c both ways or as directed by Engineer-in-Charge), placing plants
in position, refilling with good soil, watering and compacting to ensure
survival. The work includes all labour, material, watering, tools, tackles etc.
SBD SECTION-7 BILL OF QUANTITIES-596
9 Tree plantation:
Digging holes in ordinary soil and refilling the same with the excavated earth
mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked
volume of earth after reduction by 20% : 1 part of stacked volume of manure
after reduction by 8%) flooding with water, dressing including removal of
rubbish and surplus earth, if any, with all leads and lifts (cost of manure,
sludge or extra good earth if needed to be paid for separately)
2.14.3 Holes 60 cm dia, and 60 cm deep
10 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and
trenching the excavated base to a further depth of 30 cm, refilling the
excavated earth after breaking clods and mixing with sludge or manure in the
ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one
part of stacked volume of sludge or manure after reduction by 8%), flooding
with water, filling with earth if necessary, watering and finally fine dressing,
leveling etc. including stacking and disposal of materials declared
unserviceable and surplus earth by spreading and leveling as directed, within
a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra
earth to be paid for separately)
11 Plantation of Trees, at site i/c watering and removal of unserveiceable
material’s as per direction of officer in charge (excluding cost of plant &
12 Providing (Purchase) of various type tree Including cost of expertise,
transportation, loading, unloading, all taxes etc. complete as per specification
and as directed by Muni. Engineer-in-charge.
12.1 Azadirachta indicia (Neem) height 120-130cm in big polybag size 25 cm 55.00 Nos 72.92
12.2 Bassia latifolia (Mahua) height 90-105 cm. in big polybag size 25 cm 55.00 Nos 71.71
12.3 Bauhinia purpurea (Kachnar) height 150-165 cm. in big polybag size 25 cm
12.4 Delonix regia (Gulmohar) height 150-165 cm. in big poly bag size 25 cm 55.00 Nos 65.65
12.5 Ficus benghalensis (Banyan) height 120-135 cm. in big poly bag size 25 cm
12.6 Bottle palm ht. 150-180 cm bottom girth 20-25 cm well developed in big poly
bag size 25 cm 50.00 Nos 196.95
12.7 Ficus religiosa (Pepal) height 150-165 cm. in big poly bag size 30 cm 50.00 Nos 72.92
12.8 Tamarindus indica (Imli) height 120-150 cm. in big polybag size 25 cm 52.00 Nos 87.52
12.9 Terminalia arjuna height 150-165 cm. in big polybag size 25 cm 52.00 Nos 65.65
SBD SECTION-7 BILL OF QUANTITIES-597
12.10 Phyllanthus emblica (Amla) height 150-165 cm. in Big HDPE Bag 50.00 Nos 98.48
12.11 Mimusops elengi (Maulsri) height 180-195 cm., well developed with thick
stem in big in big size HDPE bag 50.00 Nos 137.36
12.12 Providing and stacking of Spathodea campanulata height 150-165 cm. in poly
bag size 25 cm as per direction of the officer-in-charge. 52.00 Nos 82.67
12.13 Providing and stacking of Cassia fistula (Amaltash) height 120-135 cm. in poly
bag size 25 cm as per direction of the officer-in-charge. 53.00 Nos 70.50
12.14 Providing and stacking of Cassia siamea height 150-165 cm. in poly bag size
25 cm as per direction of the officer-in-charge. 55.00 Nos 72.92
12.15 Providing and stacking of Lagerstroemia flosreginae height 150-165 cm.in
poly bag size 25 cm as per direction of the officer-in-charge. 55.00 Nos 131.30
12.16 Providing and stacking of Mangifera indica (Mango-grafted ) of height 60-75
poly bag of size 25 cm as per direction of the officer-in-charge. 20.00 Nos 60.80
12.17 Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in
poly bag of size 25 cm as per direction of the officer-in-charge. 20.00 Nos 87.49
12.18 Providing and stacking of Eugenia jambolana (Jamun) of height 150-165 cm.
in poly bag of size 25 cm as per direction of the officer-in-charge. 20.00 Nos 85.09
12.19 Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm.
in Big HDPE Bag as per direction of the officer-in-charge. 20.00 Nos 98.48
12.2 Providing and stacking of rayan of height 120-150 cm. in poly bag of size
cm as per direction of the officer-in-charge. 15.00 Nos 75.75
12.21 Providing and stacking of Pomegranate of height 120-150 cm. in poly bag of
size 25 cm as per direction of the officer-in-charge. 15.00 Nos 116.15
12.22 Providing and stacking of custard apple of height 120-150 cm. in poly bag of
size 25 cm as per direction of the officer-in-charge. 20.00 Nos 119.18
12.23 Providing and stacking of badam of height 120-150 cm. in poly bag of size
cm as per direction of the officer-in-charge. 20.00 Nos 55.55
SBD SECTION-7 BILL OF QUANTITIES-598
13 Providing and stacking of shrubs of height 60-90 cm. in poly bags of size 15-
20 cm as per direction of the officer-in-charge. (Select shrubs as per attached
shrub list/specifications)
13.1 Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage,
well formed in cement pot of size 30 cm 170.00 Nos 246.79
13.2 Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pot of
size 20 cm 170.00 Nos 54.69
13.3 Hamelia patens of height 90-105 cm. bushy in big size HDPE bag 150.00 Nos 109.43
13.4 Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag 170.00 Nos 98.48
13.5 Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm.
in earthen pot of size 20 cm as per direction of the officer-incharge.
13.6 Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branched in
earthen pot of size 25 cm 150.00 Nos 120.34
13.7 Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in poly bag of
size 25 cm 146.00 Nos 43.78
13.8 Providing and stacking of Mimusops elengi (Maulsri) of height 150-165 cm. in
poly bag of size 25 cm as per direction of the officer-in-charge.
13.9 Providing and stacking of Alstonia scholaris of height 150-165 cm. in bag of
cm as per direction of the officer-in-charge. 30.00 Nos 71.71
13.1 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm
Earthen pot of size 20 cm as per direction of the officer-in-charge. 30.00 Nos 43.78
13.11 Providing and stacking of Albizzia lebbek of height 150-165 cm. in bag of size
25 cm as per direction of the officer-in-charge. 30.00 Nos 70.50
13.12 Providing and stacking of Michelia champa (Golden Champa) of height 90-
105 cm. in earthen pot of size 25 cm as per direction of the officer-in-charge.
13.13 Providing and stacking of Millingtonia hortensis of height 150-165 cm. in poly
bag of size 25 cm as per direction of the officer-in-charge. 36.00 Nos 76.56
SBD SECTION-7 BILL OF QUANTITIES-599
13.14 Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75
cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-
charge. 36.00 Nos 42.57
13.15 Providing and stacking of Murraya exotica of height 45-60 cm. in poly bag of
size 15 cm as per direction of the officer-in-charge. 36.00 Nos 17.02
13.16 Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3-4
branches in earthen pot of size 20 cm as per direction of the officer-in-charge.
13.17 Providing and stacking of Rose of height 45-60 cm. in poly bag of size 15 cm
as per direction of the officer-in-charge. 36.00 Nos 17.17
13.18 Providing and stacking of angelonia angustifolia of height 45-60 cm. in poly
bag of size 15 cm as per direction of the officer-in-charge. 36.00 Nos 121.20
13.19 Providing and stacking of Cestrum diurnum of height 45-60 cm. in poly bag of
size 15 cm as per direction of the officer-in-charge. 34.00 Nos 126.25
13.20 Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6
in p.bag of size 25 cm as per direction of the officer-in-charge. 150.00 Nos 49.84
13.21 Providing, stacking and Displaying Ixora singaporensis different colour having
30 cm and above ht., well developed with fresh & healthy foliage with bloom
in 25 cmEarthen Pot/Plastic Pot and as per direction of the officer-in-charge.
13.22 Providing and stacking of Allamanda cathartic of height 30 cm to 45 cm. in
cm size of Earthen pot / Plastic pot as per direction of the officer-in-charge.
13.23 Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm.
inearthen pot of size 20 cm as per direction of the officer-in-charge.
13.24 Providing and stacking of Tecoma gaudichaudi of height 60-75 cm. with 5-6
branches in p.bag of size 25 cm as per direction of the officer-in-charge.
13.25 Providing and stacking of Tecoma capensis of ht 30-40 cm, healthy, well
developed in Poly Bag as per direction of the officer-in-charge. 150.00 Nos 60.20
13.26 Providing and stacking of Galphimia nitida of ht 20-25 cm, healthy, well
developed in Poly Bag as per direction of the officer-in-charge. 144.00 Nos 48.63
SBD SECTION-7 BILL OF QUANTITIES-600
13.27 Providing and stacking of Stachytarpheta mutabilis of ht 20-25 cm, healthy,
well developed in Poly Bag as per direction of the officer-in-charge.
13.28 Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm. in
earthen pot of size 20 cm as per direction of the officer-in-charge. 100.00 Nos 43.78
13.29 Providing and stacking of Jatropha multifida (red colour) of height 45-60 cm.
with 2-3 branches in earthen pot of size 20 cm as per direction of the officer-
in-charge. 100.00 Nos 38.89
13.3 Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm.
in earthen pot of size 20 cm as per direction of the officer-in-charge.
13.31 Providing and stacking of Tecoma capensis of ht 30-40 cm, healthy, well
developed in Poly Bag as per direction of the officer-in-charge. 100.00 Nos 30.40
13.32 Providing and stacking of Galphimia nitida of ht 20-25 cm, healthy, well
developed in Poly Bag as per direction of the officer-in-charge. 100.00 Nos 25.55
13.33 Providing, stacking and Displaying Lantana sp. of White colour, well
developed with fresh & healthy foliage with bloom in 20 cm Earthen
Pot/Plastic Pot and as per direction of the officer-in-charge. 100.00 Nos 47.37
13.34 Providing, stacking and Displaying Lantana sp. of purple colour, well
developed with fresh & healthy foliage with bloom in 20 cm Earthen
Pot/Plastic Pot and as per direction of the officer-in-charge. 100.00 Nos 47.37
13.35 Providing and stacking of Hibiscus rosasinensis of height 45-60 cm. with 3-4
branches in earthen pot of size 20 cm as per direction of the officer-in-charge.
13.36 Providing and stacking Wadelia trilobata, full of leaves in Poly Bag and as per
direction of the officer-in-charge. 100.00 Nos 7.27
13.37 Providing and stacking Clerodendrum inerme having ht. 25 cm to 30 cm multi
branched in 25 cm size of Earthen Pot / Plastic Pot and as per direction of the
charge. 104.00 Nos 24.29
13.38 Providing and stacking ipomea batata green having ht. 25 cm to 30 cm multi
branched in 25 cm size of Earthen Pot / Plastic Pot and as per direction of the
charge. 104.00 Nos 30.30
SBD SECTION-7 BILL OF QUANTITIES-601
13.39 Providing and stacking of stachytarpheta indica of ht 20-25 cm, healthy, well
developed in Poly Bag as per direction of the officer-in-charge. 110.00 Nos 30.30
13.40 Providing, stacking and Henna Plant of height 25 to 30 cm., 2 to 3 suckers in
20 c.m Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
SBD SECTION-7 BILL OF QUANTITIES-602
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF PUMP ROOM AT GOVINDPURA POND AT PADRA
Item Qty. Total Unit Amount
1 32.00 Excavation for foundation upto depth
m.Depth including sorting out and stacking of
useful material and disposing off the excavated
stuff upto 50 m lead (loose or soft soil)
2 5.00 Excavation for foundation for depth 1.5 m. to
3.0 m including sorting out and stacking of
useful material and disposing off the excavated
stuff upto 50 m lead (loose or soft soil)
3 24.00 Filling available excavated earth (excluding rock)
in trenches plinth, sides of foundations etc. in
layers not exceeding 20 cm in depth
consolidating each deposited layer by ramming
and watering. 133.65 Cmt.
4 10.50 Filling in foundation and plinth with murrum or
selected soil in layers of 20cm thickness
including watering, ramming and consolidating
etc. complete. 296.29 Cmt.
5 16.00 Applying General insecticide pest control
treatment to floors, cup boards etc. including
labour material etc. complete. Using
Heptachloride 20 EC. As per 6113_pests
constructions weight 0.50 percent is
recommended one litre chemical emulsion
dillute with 39 liter of water will give. total
dillute concentration will be 40 litre inclusive of
one litre chemical emulsion application 0.5 litre
chemical/ sqm of surface is recommended as
SBD SECTION 7 BILLOF QUANTITIES-603
Item Qty. Total Unit Amount
6 7.50 Providing and laying cement concrete 1:3:6 (1
Cement, 3 coarse sand, 6 hand broken stone
aggregates 40mm. Nominal size) and curing
ecomplete excluding cost of formwork in (A)
Foundation and Plinth.( More then 10 ton)
7 Providing and laying controlled cement
concrete M-250 and curing complete Including
the cost of formwork But Excluding cost of
reinforcement of reinforced concrete work in
a. 5.00 -- do -- for R.C.C. Column Footing 4707.61 Cmt.
b. 1.00 -- do -- for R.C.C. Column upto PL 7623.48 Cmt.
c. 2.00 -- do -- for R.C.C. Column Super Structure 8780.94 Cmt.
d 2.50 -- do -- for Ground Beam 5875.17 Cmt.
8 Providing and laying controlled cement
concrete M-200 and curing complete Including
the cost of formwork But Excluding cost of
reinforcement of reinforced concrete work in
a 2.00 -- do -- for RCC Flooring 6218.57 Cmt.
a 0.50 -- do -- for Coping 6218.57 Cmt.
b 1.00 -- do -- for R.C.C. Lintel 7854.77 Cmt.
c 1.50 -- do -- for R.C.C. Chajja 6555.91 Cmt.
d 2.00 -- do -- for R.C.C. Beam 6182.21 Cmt.
e 3.50 -- do -- for R.C.C. Slab 6661.96 Cmt.
SBD SECTION 7 BILLOF QUANTITIES-604
Item Qty. Total Unit Amount
9 1840.00 Providing TMT Bar FE 500D reinforcement for
R.C.C. work including bending, binding and
placing in position complete
upto floor two level 77.29 Kg.
10 5.00 Brick work using common burnt clay building
bricks having crushing strngth not less than
Kg./cm2 in C.M. foundation and plinth (1:6) (1
Cement, 6 fine sand) (B)Conventional racking
out joints curring etc. complete directed by
Engineer-in-charge. ( more than ten ton )
11 14.00 Brick work using common burnt building bricks
having crushing strngth not less than
Kg./cm2 in super structure for Ground Floor in
C.M. (1:6) (1 Cement, 6 fine sand)
(B)Conventiona racking out joints curring etc.
complete directed by Engineer-in-charge.
12 4.00 Providing and Fixing Rolling Shutters of
approved make made of 80 mm wide M.S. laths
inter-locked together through their entire
length and jointed together at the ends by end
locks mounted on specially designed pipe shaft
with bracket plates, guide channels and
arrangements for inside and outside locking
with push-pull operation including the cost of
hood cover and spring etc. complete (B) Shutter
having width below 3.5 m
13 0.50 Providing and fixing glazed louverd glass
windows and ventilators with teakwood frame
10cm x 7cm size including the cost of oil
painting to wood work etc. complete.(up to
Ton) 4202.12 Smt.
14 Providing and fixing M. S. grills of requried
pattern to wooden frames of window etc. with
M. S. flats at requried spacings and frame
alround square or round bars with round
headed bolts and nuts or by screws.
(A) 250.00 Plain Grill 105.18 Kg.
SBD SECTION 7 BILLOF QUANTITIES-605
Item Qty. Total Unit Amount
15 18.00 Painting two coats (Including Priming Coat) on
new steel and other metal surfaces with
synthetic enamel paint brushing,interior to
give enamel paint brushing, interior to give an
even shade including cleaning the surface an
even shade including cleaning the shurface of all
dirt, dust and other foreign matter.
16 53.00 Providing and laying 15mm thick cement plaster
in single coat Rough (Similar) side of single or
Half brick walls for interior plastering upto floor
two level and finished even smooth in (i) C.M.
(1 : 4) (1 -Cement : 4 -sand ) including neat
Cement slury finishing scaffolding, curing etc.
17 16.00 Providing and laying 10mm thick cement plaster
in Single coat on brick/concrete walls for
plastering on ceiling and soffits of stairs upto
floor two level and finished even smooth in (i)
C.M. (1 : 4) (1 -Cement : 4 -sand ) including neat
Cement slury finishing scaffolding, curing etc.
complete. 126.35 Smt.
18 143.00 Providing and Laying 20 mm thick sand face
cement plaster on Walls upto height of 10 mts.
Above ground level consisting of 12mm thick
backing coat of C.M 1:3 (1 Cement, 3 Sand ) and
8 mm thick finishing coat of C.M 1:1 (1 Cement,
1 Sand) etc. complete.
19 69.00 Applying two coats of Birla (white cement
based) or Asian (acrylic lapy-putty)or equivalent
& two coats of primer of approved brand and
manufacture on new wall surface to give an
even shade including thoroughly brushing the
surface from mortar dropping and other foreign
matter and sand papered smooth
SBD SECTION 7 BILLOF QUANTITIES-606
Item Qty. Total Unit Amount
20 53.00 Distempering (Three Coat) with oil bound
washable distemper of approved brand and
manufacture and of required shade on wall
surfaces to give and even shade over and
including a primer coat with alkali resistance
primer of approved brand after throughly
brushing the surface free from other foreign
matter and also including preparing the surface
even and sand papered smooth.
21 16.00 Distempering (Three Coat) with oil bound
washable distemper of approved brand and
manufacture and of required shade on Ceiling &
Sloping Roof surfaces to give and even shade
over and including a primer coat with alkali
resistance primer of approved brand after
throughly brushing the surface to give and free
from other foreign matter and also including
preparing the surface even and sand papered
smooth. 109.91 Smt.
22 143.00 Finishing wall with Weather Proof Acrylic
Emulsion Exterior Paint on wall surface (two
coat) to give and even shade and of approved
brand and manufacture including throughly
brooming and brushing the surface to remove
all dirts, and remians of loose powdered
material. 117.40 Smt.
23 38.00 Providing and laying cement concrete flooring
1:2:4 (1 cement : 5 corase sand :4 graded stone
aggregate 20 mm nominal size) laid in one layer
finished with floating coat of neat cement.
50mm thick (Upto10 ton)
24 3.00 Providing and fixing in position cowel went to
pipes.(B) 75mm dia. 393.04 No
25 4.00 Providing and fixing M.S. Fan clamps type 1 to
16mm dia M.S. bar bent to shape with hooked
ends to R.C.C. slab curing, laying including
painting the exposed portion of loops, all as per
standard design complete. 131.93 No
SBD SECTION 7 BILLOF QUANTITIES-607
Item Qty. Total Unit Amount
26 5.30 Purchasing & supplying at site of works with
railway freight, loading, unloading, carting etc.
complete such as joints, channels, angle irons,
rails etc. complete. M.S. Rails 200 x 100 x 6 mm
M.S. Rails 200 x 100 x 6 mm size 2979.50 R.M.T.
27 0.30 Labour charges for lowering, laying, fixing
various size of M.S. sections such asjoints,
channels, angles, plates etc. complete
28 16.00 Providing and Laying broken China Mosaic
Flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain slope and to be
tempered to bring mortar crème out upto
surface using white cement including rounding
off junctions and extending them up to 15 cm
along the wall clearing with water and oxalic
acid etc. as directed. 765.97 Smt
29 7.50 P.V.C. Pipes 10 kgf / Sq.cm. 75mm dia. 161.77 Rmt.
Add Electrical As Per Sub Estimate
SBD SECTION 7 BILLOF QUANTITIES-608
PADRA NAGARPALIKA PADRA
PROVIDING ELECTRIFICATION INSTALLATION IN PUMP ROOM AT GOVINDPURA POND AT PADRA
SCHEDULE B-12.1
SR DESCRIPTION QTY UNIT RATE AMOUNT
1 Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires, in following type of pipe to be erected concealed in/ on
surface on wall/ceiling complete with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC /
Metallic box, single mounting base frame covered with textured/metallic 5.00 Pt. 449.45
front plate modules erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
2 Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper
wires, in following type of pipe to be erected concealed in / flushed on
wall/ceiling complete with 6A Modular type switch and hum free EME four
or more step type electronic fan regulator with separately mounted and
accessories with earth continuity of following type erected on PVC / Metallic 1.00 Pt. 638.32
box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
3 Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires,
in following type of to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected on PVC / Metallic
box covered with appropriate front plate modules erected on / in wall / 1.00 Pt. 702.96
ceiling as per pipe erected with following type of accessories.
[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
4 [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories erected flushed on 1.00 Pt. 711.04
wall/ceiling complete. Cat.III
5 Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic box, single mounting base frame covered with
textured / metallic front plate modules erected on / in wall / ceiling with
following type accessories Cat. III
6 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive solution & Clamps with 12.00 Mtr. 33.33
following dia of pipes, in approved manner as directed (b) 25 mm
7 Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts etc. complete of following sizes. (2) 25 mm 25.00 Mtr. 21.21
SBD SECTION-7 BILL OF QUANTITIES-609
8 Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC 25.00 Mtr. 82.82
insulated stranded wire of green colour for earth continuity of following size
(a) with medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
9 Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of 10.00 Mtr. 112.11
green colour for earth continuity of following size (a) with medium class
Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
10 Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house 1.00 Ea. 2445.21
appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for (B)(iii) Three phase 8 way SS Double door for
horizontal single phase outgoing
11 providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
12 Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity (B) 40 Amp. Cat.III
13 Providing & erecting L.T. Current Transformer with bar primary 50/5 to
1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with 1.00 Ea. 274.72
insulating materials connected to the meter
14 Supplying & erecting funnel type earthing having earth plate of following
size burred in specifically prepared earth pit 3 mtr. below ground with
kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I.
pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I.
Cover complete as per para 7.3 of IS 3043 with necessary length of double
Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate
and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to
the nearest switch gear with end socket as per direction & duly tested by
earth tester confirming to IS (As per drawing) with following specification
(B) With 45 x 45 x 0.35 cms. C.I. earth plate 1.00 Ea. 2568.43
15 Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required. (e) One wire 6.00 sq. mm
16 Making trench in soft soil of suitable width of 90 cms deep for laying cable
or locating the fault all over the run and backfilling the same and making 5.00 Mtr. 55.55
the surface as normal ground.
17 Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (e) 2 to 4 core 25 Sq. mm
18 Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (H) 3 & 1/2 core 240 Sq. mm
SBD SECTION-7 BILL OF QUANTITIES-610
19 Solderless crimping type Aluminium lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved 5.00 Ea. 15.15
20 Providing and erecting Approved make Ceiling fan with double ball bearing
ISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete,
canopy and 30 cms. down rod erected on existing hook or clamp with 1.00 Ea. 1596.81
24/0.2 , 3 core flexible wire with earthing. [Make shall be approved by
Engineer in charge
21 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan
22 Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt
& Nuts erected with necessary hook of 10 mm M.S. Round Bar. 1.00 Ea. 98.98
23 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die
cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.95, THD
< 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED
driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll 3.00 Ea. 535.30
24 Approved make C.F.L. Retrofit 13/15/18 Watt erected if required 1.00 Ea. 137.36
25 Supplying & erecting approved make low noise decorative exhaust fan
having square frame ABS body with inbuilt lowers & square frame. 200mm 1.00 Ea. 1366.53
with 1350RPM Cat.II
SBD SECTION-7 BILL OF QUANTITIES-611
PADRA NAGARPALIKA PADRA
DRILLING OF TUBE WELL 250 MM DIA BY D. R. METHOD & 300 MM DIA PIPE WITH 27.5 H. P.
PUMP AT GOVINDPURA POND AT PADRA
Item Qty. Description Total Rate Per Amount
1 80.00 Drilling of 250 mm dia. bore well in all strata
Rmt. including dual over burden strata by
Combination DR / DTH rig including lowering
200 mm dia MS ERW pipes in bore hole as
suggested by Hydrologist
2 48.00 Manufacture, supply and delivery of ISI
Rmt. marked ERW MS pipes conforming to
IS: 4270/2001 with latest amendment
Rates are exclusive of GST
250 mm dia. (Minimum 7.10 mm thick) 3605.70 Rmt.
3 24.00 Providing of 250 mm dia Jhonson Screen
Pipe 1.0mm size. 12400.00 Slots 2258.36 Rmt.
4 8.00 Providing of 250 mm dia Jhonson Screen
Pipe 1.5mm size. 8300.00 Slots 2092.72 Rmt.
5 1.00 Clamps made from MS plate with 3 holes on
No. either side with nuts & bolts of
standard make and suitable size.
900 mm X 100 mm X 16 mm flat suitable for
250 mm dia. pipe. 2037.91 No.
6 1.00 Bore plug of 100 mm height made from MS
No. plate with 3 holes at equal distance on
circumference for nut-bolts type, locking
arrangement with nutsbolts & lock nuts of
iii) Suitable for 250 mmdia pipe 1161.62 No.
7 1.00 M.S. Bail plug having length 0.45 mt. from
No. medium class pipe as per I.S.S. suitable for
250 mm dia pipe. 1065.02 No.
SBD SECTION 7 BILL OF QUANTITIES-612
8 27.00 Steel bend plate suitable to ERW pipe as
Nos. detailed below.
9 8.00 Best quality of well stored Sevalia graval of
Cmt. size 4 mm to 6 mm at site.
10 4.00 Supply of clay balls having size of 25mm to
50mm made from sticky clay at site of work.
Cmt. 758.51 Cmt.
11 1.00 Developing of bore hole of above mentioned
Job. drilled reamed. (900 CFM/200 PSI)
12 1.00 Uptron make Eloctrologger (without carting) 18180.00 Job
13 1.00 Geohydrological ground water
investigations. (with vehical charges).ii)
200/250 mm dia Deep Tube Well (with
water sample) 14428.86 Job
14 1.00 Water Chemical analysis charges 606.00 No.
15 50.00 Providing and supplying D.I. K-9 grade pipes
for following nominal bore diameter with
internal cement mortar lining including all
taxes, insurance, transportation, freight
charges, octroi, inspection charges, loading,
unloading, conveyance to departmental
stores, stacking etc. complete. (IS 8329-
2000) Rate for DI Pipe based on wholesale
Price Index of pig iron as 147.1 for month of
With Excise Duty
Do For 300 mm Dia 3690.54 Rmt
16 25.63 Manufacture, Supply & Delivery of Ductile
Iron Flange socket spigot bends, tees,
reducers or any other specials as per BS-EN-
545/1995 Class-A series K12 suitable for use
with D.I.Pipes manufactured as per
IS:8329/1994delivery of specials is to be
made to GWSSB store or site of works any
where in Gujarat including all taxes, liading,
unloading, carting, stacking, insurance,
inspection charges, octroi etc. complete
80 to 300mm dia 156.55 Kgs
SBD SECTION 7 BILL OF QUANTITIES-613
17 54.00 Excavation for pipe line trenches incl. all
Cmt safety provisions using site rails and stacking
excavated stuff up to a lead of 90 mts.
cleaning the site etc. complete for lifts and
strata as specified.* In all sorts of soil and
* upto 1.5m depth 102.35 Cmt
18 50.00 Lowering, laying and jointing C.I. S & S Spun
Cmt pipes suitable for tyton joints/Mortar lined
D. I. Pipes of various classes with CI/MS
specials of following diameters in proper
position, grade and alignment as directed by
engineer-in-charge including hydraulic
testing etc. complete.
Do For 300 mm Dia 178.25 Cmt
19 4.00 Providing C.C. M - 100 for encasing of Pipe
Cmt Using trap metal size 40 mm to 50 mm
including formwork curing etc. complete.
Do For 300 mm Dia 4567.80 Cmt
20 47.00 Refilling the pipeline trenches including
Cmt ramming, watering, consolidating, disposal
of surplus stuff as directed within a radius of
Do For 300 mm Dia 25.30 Cmt
21 550.00 Providing laying and jointing in true line and
Rmt. level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for
cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the
wall with the help of clamp at every two
metre C/C or shall be concealed as directed
including necessary fittings etc. including
testing of pipe and joints and fixing the same
with adhesive solvent, including cost of all
SBD SECTION 7 BILL OF QUANTITIES-614
22 250.00 Providing, laying and jointing in true line and
Rmt. level 32 mm dia U.P.V.C. Pipe (SCH-40)
including fittings make as approved by
Engineer In Charge. Pipe shall be fixed on the
wall with the help of clamp at every two
meter c/c. or shall be concealed as directed
including necessary fittings etc. including
testing of pipe and joints and fixing the same
with adhesive solvent, including cost of all
23 150.00 Providing laying and jointing in true line and
Rmt. level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for
cold water including fittings as approved by
Engineer In Charge. Pipe shall be fixed on the
wall with the help of clamp at every two
metre C/C or shall be concealed as directed
including necessary fittings etc. including
testing of pipe and joints and fixing the same
with adhesive solvent, including cost of all
Add Pumping Set As Per Sub Estimate
SBD SECTION 7 BILL OF QUANTITIES-615
PADRA NAGARPALIKA PADRA
DRILLING OF TUBE WELL 250 MM DIA BY D. R. METHOD & 300 MM DIA PIPE WITH
H. P. PUMP AT GOVINDPURA POND AT PADRA.
DESCRIPTION QTY. UNIT AMOUNT
Supplying at departmental store. Board
Approved make Electric motor driven
submersible pump set conforming to I.S.
8034/198/and motor confirms to IS-9283-
1979 working at 3 phase 400/440 volt
C/S A.C Supply & 2900 R.P.M. for 10" dia
Bore Well. 1200 L.P.M, 63 M. Head.
Flat PVC cable for submersible pump
detailed specification as per GWSSB rate
contract. 1 x 3 x 10 Sq.mm. 50.00 Mt. 291.89
Auto transformer starter suitable for
local & remote pump control application
consisting of Auto Transformer (vacuum
impregnated, air cooled having three (3)
tappings at 50%, 65% and 80%), incomer
MCCB / MPCB, overload relay and
contactors as per Type II coordination
including digital MFM with RS
communication port, analogue type
ammeter with selector switch, run hour
meter, required protective relays &
control accessories. A. T. S. from 21 to
SBD SECTION-7 BILL OF QUANTITIES-616
Labour charges for fixing ATS control
pannel board including carting of control
pannel board from store to site and
including making GE power connection
etc. complete. 1.00 No. 756.49
Supplying & erecting funnel type
earthing having earth plate of following
size burred in specifically prepared
earth pit 3 mtr. below ground with 40 kg.
charcoal and salt with alternate layers of
charcoal & salt, 20mm.dia. G.I. pipe with
Funnel with a wire mesh for watering &
bricks masonry block, C.I. Cover complete
as per para 7.3 of IS 3043 with necessary
length of double Galvanised Iron /
copper earth wire No 6 SWG bolted with
lug to the plate and covered in 12 mm
dia. G.I. pipe 2.5 mtr long complete
connected to the nearest switch gear
with end socket as per direction & duly
tested by earth tester confirming to IS
(As per drawing) with following
specification (A) With 30 x 30 x 0.35 cms:
C.I. earth plate 1.00 No. 2311.89
Providing heavy duty galvanized iron
column pipe threaded at both end
having approx. length of 3 mts.
Confirming to IS 1239(Part-1) with
coupling at one end and threaded
protector at other end size 100mm dia. 60.00 Mt. 743.36
SBD SECTION-7 BILL OF QUANTITIES-617
Providing support clamp of size 450 x
x 10mm, suitable to 100 mm dia pipe. 2.00 Pair 574.69
Providing, Supplying and fitting of ISI
mark Double Flange Sluice Valve
including all taxes, insurance,
transportation, freight charges, octroi,
inspection charges, loading, unloading,
conveyance to departmental stores,
stacking etc. complete with ISI mark only.
P.N. 1.6 with Hand Wheel/Cap Operated
(PD type Short Body)
100 mm Dia. 1.00 Set
Providing, Supplying and fitting of C. I.
Reflux valve tested to pressure of
Kg./Cm2 for seat as per IS-5312,P.N.
100 mm Dia. 1.00 No.
Providing and Fixing C.I./M.S. flanged
with bolts, Rubber Packing etc. complete
(H.D.) 100 mm Dia.
Providing heavy duty 90˚ G. I. Bend R
brand suitable for 100 mm size pipe. 1.00 No.
Heavy duty M.S. coupling 100 mm dia.
mm thick, 150mm long
SBD SECTION-7 BILL OF QUANTITIES-618
Lowering of submersible motor pump set
complete with required Nos. and size of
casing pipes erected by means of proper
chainpulley block and pipe wrenches
after cheking of threads of each pipe
with coupling to take the load of the
pump set and pipe assembly fild up with
water. Upto 60 mtrs. 1.00 No.
Providing bore plate made from 6 mm
thick M.S. plate suitable up to 250 mm
dia bore well pipe.
SBD SECTION-7 BILL OF QUANTITIES-619
PADRA NAGARPALIKA PADRA
SUPPLYING, ERECTING & COMMISSIONING OF STREET LIGHT WITH LED AT GOVINDPURA
POND AT PADRA (15 Rmt C/C )
Sr. Total Unit Amount
Qty Discription
1 650.00 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected
as directed of following size. (A) 2 core 2.5 Sq. mm
2 2.00 providing and erecting Approved make Four pole
moulded case circuit breaker having breaking capacity
ICU of 25 KA. at 415 V,having normal current rating up
to 25 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal
connections & complete erected in existing 16 G.M.S.
housing. Cat.II
3 2.00 Approved make ELCBs / RCCBs conforming to IS:
and having sensitivity of 30 mA and Short Circuit
withstand capacity of 6 KA and suitable for operation
on 3 phase and neutral 415V. having characteristic of
quick action & tripping with all advance feature & do
not incorporate any electronic component for following
Max. rating erected as directed.(iii) 63 Amps. FP
Cat.III 3040.10 Ea.
4 65.00 Miniature circuit breaker single pole 6A to 32A suitable
to operate on 240 V A.C. system and having breaking
capacity 10 K.A. to be erected in existing box.
Confirming to IS 8828/1996 with ISI Mark.Cat.II
5 20.00 Providing and erecting Annealed bare Copper wire 8 to
6 65.00 Pipe type earthing having 150 cms.long and 2.5 cms.
dia. galvanised iron pipe with coupling and buch
burried in specially prepared earth pit complete with
necessary 8 SWG earth wire. 368.65 Ea.
SBD SECTION7 BILL OF QUANTITIES-620
7 2.00 Supplying & erecting funnel type earthing having earth
plate of following size burred in specifically prepared
earth pit 3 mtr. below ground with 40 kg. charcoal and
salt with alternate layers of charcoal & salt, 20mm.dia.
G.I. pipe with Funnel with a wire mesh for watering &
bricks masonry block, C.I. Cover complete as per para
7.3 of IS 3043 with necessary length of double
Galvanised Iron / copper earth wire No 6 SWG bolted
with lug to the plate and covered in 12 mm dia. G.I.
pipe 2.5 mtr long complete connected to the nearest
switch gear with end socket as per direction & duly
tested by earth tester confirming to IS (As per drawing)
with following specification.(C) with 60 x 60x
cms. Copper earth Plate
8 65.00 For using salt and charcoal/coke as required for pipe
type earthing. 171.70 Ea.
9 975.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (A)
10 975.00 Providing & laying approved make Double Walled
Corugated pipe (DWC) of polythylene (Confirming to IS-
14930-II) with necessary connecting accessories of
same materials at required depth for laying of cable.
Below ground / road surface for enclosing cable and
back filling the same to make ground as per original. (A)
11 117.00 Supplying following size of Light duty “A” Class G.I.
Pipe & erecting as directed by Engineer-in-charge. (A)
25 mm dia 172.71 Mtr.
12 520.00 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured
cable complete with out going tails, insulating tape etc
for following size of cables.(D) 2 to 4 core 16 Sq. mm
SBD SECTION7 BILL OF QUANTITIES-621
13 65.00 Supplying and erecting approved make Conical Pole
(Medium Duty ) Made from HR sheet steel. The pole
should be made as per IS. and shall be coated with hot
dip galvanizing as per IS 2629/2633/4759, with
required base plate and integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard
profile 35mmX7.5mm Din-Rail for MCB Mounting, stud
type terminal and arrangement for cable terminations
as erected on suitable foundation (included) with
necessary GI nut-bolts/J-Bolts. as per details given by
manufacturer considering site requirement. The length
of poles are as below.
(E) 7 Mtr. Long 70 mm Top X 175 mm bottom dia,
mm thickness 12240.19 Ea.
14 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for
mm /80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane &
suitable welded stays, reducer and with check nuts
complete painted with one coat of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint
with following nos of arms.
65.00 [A] Single Arm bracket 1 Mtr 561.56 Ea.
15 65.00 Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die
cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass
with company mark/name engraved or embossed
to 270 V,Power Factor more than 0.95, THD < 10 %,
CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency >
%.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the
ranges shown.) (B) Flood Light (IP-65), Surge
protection -4KV integral and ,Light must have 440VAC
line supply with over-voltage Protection. (ii) above
to 60 Watts Cat-lll
SBD SECTION7 BILL OF QUANTITIES-622
16 2.00 Supplying & erecting approved make Digital time
switch having lithium cell 6 years operative and
operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V +
5%, 16A with, floating contacts Minimum switching
setup time 1 minimum & LCD display. Also comprised
permanent ON/OFF switching. Programming switches
& housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary
connection erected as directed.
17 2.00 Supplying & Erecting Power Contactor for time switch
complete erected as per directions Cat-III. [D] 4 pole
18 2.00 Supplying & erecting IP 55 grade following size section
pillar fabricated from joint less M.S. Sheet with angle
iron legs made from jointless M.S. Angle with cable
clamps to be buried in ground to have appropriate
erection to work uniform until erected with cement
concrete foundation and 45 cms high bricks work
finishing with plaster etc. hinged double door internally
supported on both side, with internal and outside
looking arrangement with look and keys in duplicate
x 35 x 5 mm M.S. Angle of Two Nos. one is welded and
other with nut and bolt for erecting bakelite sheet.
Painting the Section Pillar inside and out side with
three tank powder coated paint. section pillar roof
should be without joint with water leakage proof &
tested as per IP 55 test & followed by IS 2147 of
(B) 75 X 60 X 45 cm section pillar fabricated from
Gauge MS Sheet with angle iron legs 45 cm long made
from 35 X 35 X 5 mm thick MS angle.
SBD SECTION7 BILL OF QUANTITIES-623
PADRA NAGARPALIKA PADRA
DEVLOPEMENT OF CHILDREN PLAY AREA AND PLAYING EQUIPMENT AT GOVINDPURA POND
Item Qty. Description Total Unit Amount
1 188.50 Filling in plinth with sand under floors
Cmt including watering ramming, consolidating
and dressing complete. 460.19 Cmt.
2 40.00 Providing , Supplying & Fixing Reinforced
Nos Cement Concrete Modern RCC Bench, For
Outside, With Back. As Per Directed Engi. In
Charge Icluding Labour, Transpotation. Etc
complete. 5555.00 Nos
3 40.00 HDPE Grade Plastic Material Twin Dustbin
Nos including MS Stand for Road side garbage
collection with all Fixtures. 4038.99 Nos
4 Providing, supplying and fixing Children
playing equipments of Maruti Playground
equipments Co, or equivalent & approved
made including all kind of labor charges and
Tax etc completec with concrete Foundation
as direct on site by engineer in charge.
a 1.00 Fiber spiral slide 9ft high 106555.00 Nos
b 1.00 Double sea Saw 24442.00 Nos
c 1.00 Rocking Boat 12625.00 Nos
d 1.00 Round Jungle Gym 27674.00 Nos
e 1.00 Rainbow climber 35552.00 Nos
f 1.00 Double Swing 18079.00 Nos
g 1.00 Four seater arc swing 92415.00 Nos
h 1.00 Standing Large MGR( Revolvng Plateform) 40299.00 Nos
i 1.00 Swinging Loop Ring 25250.00 Nos
SBD SECTION 7 BILL OF QUANTITIES-624
PADRA NAGARPALIKA PADRA
CONSTRUCTION WORK OF SHOPS AT GOVINDPURA POND AT PADRA.
Qty. Description Unit Amount
1 56.70 Excavation for base footings upto depth
Cmt. m. including sorting out and disposing of
the excavated material upto 50 m lead
(loose or soft soil) 120.01 Cmt.
2 32.50 Filling available excavated earth (excluding
Cmt. rock) in trenches. plinth, sides of
foundations etc. in layers not exceeding
cm. in depth consolidating each disposited
layer by ramming and watering.
3 12.84 Filling in foundation and plinth with murrum
Cmt. or selected soil in layers of 20cm thickness
including watering, ramming and
consolidating etc. complete. 296.29 Cmt.
4 42.77 Carrying out plinth treatment to post
Smt. construction/existing structure by spraying
chemical solution for termite control
treatment including labour and material
consistment with I.S.I specification. Using
Chlordene and chiorpurfiles 20 EC. As per
6131_paret-II consteration weight one
percent is recommended i.e. one litre 20 EC
chemical emulsion with 19 liter give 1%
concrentration inclusive of one litre
chemical emulsion application at the rate of
5 litre chemical/sqm of surface as
recommended as per I.S.
5 15.75 Providing and laying cement concrete 1:4:8
Cmt. (1- Cement : 4- coarse sand : 8- hand
broken stone aggregates 40 mm nominal
size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
SBD SECTION -7 BILL OF QUANTITIES-625
6 8.20 Providing and Laying controlled cement
Cmt. concrete M-250 and curing complete,
including the cost of formwork but
excluding the cost of reinforcement for
reinforced concrete work in Column
footings. 4707.61 Cmt.
7 0.90 Providing and laying controlled cement
Cmt. concrete M-250 and curing complete
including the cost of formwork But
Excluding the cost of reinforcement for
reinforced concrete work in Column upto
Plinth Level having any cross section area.
8 2.50 Providing and Laying controlled cement
Cmt. concrete M-250 and curing complete,
including the cost of formwork but
excluding the cost of reinforcement for
reinforced concrete work in Columns having
any cross section area upto floor two level.
9 2.95 Providing and laying controlled cement
Cmt. concrete M-250 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Ground Beam
having any cross section area. 5875.17 Cmt.
10 1.15 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in coping. 6218.57 Cmt.
11 1.05 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Lintel for all
floor. 7854.77 Cmt.
SBD SECTION -7 BILL OF QUANTITIES-626
12 0.60 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Chajja for all
floor. 6555.91 Cmt.
13 6.30 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Slab having any
thickness for all floors. 6661.96 Cmt.
14 4.40 Providing and laying controlled cement
Cmt. concrete M-200 and curing complete
including the cost of formwork but
Excluding the cost of reinforcement for
reinforced concrete work in Beams having
any cross section area for all floors.
3500.00 Providing TMT Bar FE 500D reinforcement
Kgs. for R.C.C. work including bending, binding
and placing in position complete upto floor
two level 77.29 Kg.
16 4.15 Brick work using common burnt clay
Cmt. building bricks having crushing strength not
less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1- Cement : 6 -
fine sand)(B) Conventional
17 24.94 Brick work using common burnt clay
Cmt. building bricks having crushing strength not
less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1- Cement : 6 -
fine sand)(B) Conventional (Extra for brick
work in superstructure above plinth level
upto floor two level (B) Conventional)
SBD SECTION -7 BILL OF QUANTITIES-627
18 26.30 Providing and fixing rolling shutters of
Smt. approved make made of 80 mm wide M.S.
laths inter-locked together through their
entire length and jointed together at the
ends by end locks mounted on specially
designed pipe shaft with bracket plates,
guide channels and arragements for inside
and outside locking with push-pull
operation including the cost of hood cover
and spring etc. complete. (B) Shutters
having width 3.5 M. and above
19 219.00 Providing and fixing M. S. grills of requried
Kgs. pattern to wooden frames of window etc.
with M. S. flats at requried spacings and
frame alround square or round bars with
round headed bolts and nuts or by screws.
(B) Plain Grills 105.18 Kg.
20 167.40 Applying Priming Coat on new steel and
Smt. other metal surface by throughly cleaning,
oil, grease and scoured with brushes fine
steel wood, scrapers and sand paper with
ready mixed priming paint brushing red lead
and Painting two coats with synthetic
enamel paint, brushing to give an even
shade including cleaning the surface of all
dirt, dust and other foreign matter.
21 64.00 Providing 10mm thick cement plaster in
Smt. single coat on brick/concrete walls for
interior plastering upto floor two level and
finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand) Extra over
items 58 to 64 for finishing with a floating
coat of neat cement slurry. Extra over items
58 to 71 for plastering on ceilings and sofits
of stairs upto floor two level instead of
plastering on walls.
SBD SECTION -7 BILL OF QUANTITIES-628
22 128.75 Providing and Laying 20 mm thick sand face
Smt. cement plaster on Walls upto height of
mts. Above ground level consisting of
12mm thicjk backing coat of C.M 1:3 (1
Cement, 3 Sand ) and 8 mm thick finishing
coat of C.M 1:1 (1 Cement, 1 Sand) etc.
complete. 337.52 Smt.
23 231.40 Distempering (Three Coat) with oil bound
Smt. washable distemper of approved brand and
manufacture and of required shade on wall
surfaces to give and even shade over and
including a primer coat with alkali
resistance primer of approved brand after
throughly brushing the surface to give and
even shade free from foreign matter and
also including preparing the surface even
and smooth. 101.75 Smt.
24 128.75 Finishing wall with weather proof exterior
Smt. emulsion paint on wall surface (two coats)
to give an required shape even shade after
thoroughly brushing the surface to remove
all dirt, and remains of loose powdered
materials.etc complete
25 47.90 Providing & Laying 24 "x 24" vitrified 8 mm
Smt. thick tile flooring over 20 mm ( average)
base of cement mortar 1:6 (1: cement :
coarse sand ) on new surface or fixing on
existing flooring by adhesive material
including dismentaling of existing flooring
and jointed with color cement slurry
including finised with flush pointing &
cleaning the surface etc. complete for
antiskit . 1432.78 Smt.
26 12.95 Providing and laying polished Granite tiles
Smt 18 mm thick in risers of steps, skirting Dedo
and pillars laid on 10 mm thick cement
mortar 1 : 3 (1 cement : 3 course sand) and
jointed with gray cement slurry mixed with
pigment to match the shade of slab
including rubbing, polishing, Moulding etc.
complete. For Flooring, Doors & Windows
SBD SECTION -7 BILL OF QUANTITIES-629
27 40.00 Providing and laying China Mosaic type
Smt. water proofing treatment in terrace
including (a) Applying neat cement slurry
2.75 Kgs./Smt. of cement admix with water
proofing compound after cleaning the
surface (b) laying cement concrete using
brick bats 25mm to 100mm isze with 50%
cement mortar 1:5 (1 Cement : 5 Coarse
Sand) admixed mortar proofing compound
over 20mm thick layer of cement mortar
1:5 to required slope including rounding of
junctions of walls and slabs (c) after two
days of proper curing applying a second
coat of cement slurry (d) finished the
surface with 20mm thick cement mortar 1:4
(1 Cement : 4 Coarse Sand) and china
mosaic tiling & finally finishing the surface
with trowel with white cement slurry (e)
after finishing the whole terrace shall be
flooded with water for a period of two
28 3.50 Providing and fixing on wall face C.I. Rain
Rmt. water pipe including filling the joints with
spun yarn soaked in neat cement slurry and
cement mortar 1:2 (1- Cement : 2-fine sand)
(A) 75 mm dia 293.62 Rmt.
Add Electrical as Per Sub Estimate
SBD SECTION -7 BILL OF QUANTITIES-630
PADRA NAGARPALIKA PADRA
PROVIDING ELECTRIFICATION INSTALLATION IN IN SHOPS AT GOVINDPURA POND AT PADRA.
SCHEDULE B-16.1
SR DESCRIPTION QTY UNIT RATE AMOUNT
1 Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires, in following type of pipe to be erected concealed in/ on
surface on wall/ceiling complete with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC / Metallic
box, single mounting base frame covered with textured/metallic front plate 15.00 Pt. 449.45
modules erected on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
2 Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper
wires, in following type of pipe to be erected concealed in / flushed on
wall/ceiling complete with 6A Modular type switch and hum free EME four
or more step type electronic fan regulator with separately mounted and
accessories with earth continuity of following type erected on PVC / Metallic 3.00 Pt. 638.32
box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
3 Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires,
in following type of to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected on PVC / Metallic
box covered with appropriate front plate modules erected on / in wall / 3.00 Pt. 702.96
ceiling as per pipe erected with following type of accessories.
[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete. Cat.III
4 [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
(a) with medium class Rigid PVC pipe and accessories erected flushed on 3.00 Pt. 711.04
wall/ceiling complete. Cat.III
5 Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic box, single mounting base frame covered with
textured / metallic front plate modules erected on / in wall / ceiling with
following type accessories Cat. III
6 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution & Clamps with 36.00 Mtr. 33.33
following dia of pipes, in approved manner as directed (b) 25 mm
7 Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts etc. complete of following sizes. (2) 25 mm 75.00 Mtr. 21.21
8 Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed in /flushed
on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated 75.00 Mtr. 82.82
stranded wire of green colour for earth continuity of following size (a) with
medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
9 Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of 30.00 Mtr. 112.11
green colour for earth continuity of following size (a) with medium class
Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm
SBD SECTION-7 BILL OF QUANTITIES-631
10 Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house 3.00 Ea. 2445.21
appropriate nos. of MCBs.(The DBs should be used of same company of MCB
to be used) suitable for (B)(iii) Three phase 8 way SS Double door for
horizontal single phase outgoing
11 providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
12 Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity (B) 40 Amp. Cat.III
13 Providing & erecting L.T. Current Transformer with bar primary 50/5 to
1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with 3.00 Ea. 274.72
insulating materials connected to the meter
14 Supplying & erecting funnel type earthing having earth plate of following
size burred in specifically prepared earth pit 3 mtr. below ground with
kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I.
pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I.
Cover complete as per para 7.3 of IS 3043 with necessary length of double
Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate
and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the
nearest switch gear with end socket as per direction & duly tested by earth
tester confirming to IS (As per drawing) with following specification
(B) With 45 x 45 x 0.35 cms. C.I. earth plate 3.00 Ea. 2568.43
15 Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel, 15.00 Mtr. 56.56
relays, power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required. (e) One wire 6.00 sq. mm
16 Making trench in soft soil of suitable width of 90 cms deep for laying cable or
locating the fault all over the run and backfilling the same and making the 15.00 Mtr. 55.55
surface as normal ground.
17 Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (e) 2 to 4 core 25 Sq. mm
18 Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. (H) 3 & 1/2 core 240 Sq. mm
19 Solderless crimping type Aluminium lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved 15.00 Ea. 15.15
20 Providing and erecting Approved make Ceiling fan with double ball bearing
ISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete,
canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2 3.00 Ea. 1596.81
, 3 core flexible wire with earthing. [Make shall be approved by Engineer in
21 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan
22 Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt
& Nuts erected with necessary hook of 10 mm M.S. Round Bar.
23 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die
cast powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED
driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges
SBD SECTION-7 BILL OF QUANTITIES-632
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll 3.00 Ea. 535.30
24 Approved make C.F.L. Retrofit 13/15/18 Watt erected if required 3.00 Ea. 137.36
25 Supplying & erecting approved make low noise decorative exhaust fan
having square frame ABS body with inbuilt lowers & square frame. 200mm 3.00 Ea. 1366.53
with 1350RPM Cat.II
SBD SECTION-7 BILL OF QUANTITIES-633
Padra Nagarpalika, Padra
Bid Documents for "Development Work for Water Body Rejuvenation of Ram Talav including Five Year Operation and Maintenance Period WBR Project
(SWAP-I & Special SWAP) under Amrut 2.0 Scheme for Bayad Nagarpalika” At.Bayad, Dist.Aravalli
Name of Work : Operation and Maintanance (for 5 Years)
Sr. No. Description O & M Percentage Schedule Capital Cost O & M for
(1%) Cost (3%) Year
B1 DEWATERING,DESILTING & LAND CLEARING Percentage 573510.11 590715.41
B2 EARTH FILLING AT GOVINDPURA Percentage 3920744.02 4038366.34
B3 CONSTRUCTION WORK OF TOE WALL Percentage 3280733.80 3379155.81
B4 CONSTRUCTION WORK OF INLET BOX DRAIN Percentage 8043882.11 8285198.57
B5 CONSTRUCTION WORK OF COMPOUND WALL, Percentage 10380764.27 10692187.20
B6 CONSTRUCTION WORK OF PATHWAY & RAILING Percentage 9118223.36 9391770.06
B7 CONSTRUCTION WORK OF SECURITY CABIN Percentage 379170.21 390545.32
B8 CONSTRUCTION WORK OF DRINKING WATER FACILITY Percentage 450301.68 463810.73
B9 PROVIDING AND LAYING OF 2000 MM DIA R.C.C. NP4 PIPE DRAIN Percentage 2129669.84 2193559.94
B10 PROVIDING,SUPPLYING AND LAYING OF 600 MM DIA RCC NP-3 PIPE DRAIN. Percentage 512427.73 527800.56
B11 HORTICULTURE SERVICES AT GOVINDPURA Percentage 4526575.26 4662372.52
B12 CONSTRUCTION WORK OF PUMP ROOM Percentage 594869.49 612715.57
B13 DRILLING OF TUBE WELL 250 MM DIA BY D. R. METHOD & 300 MM DIA PIPE WITH
H. P. PUMP Percentage 951984.76 980544.30
B14 SUPPLYING, ERECTING & COMMISSIONING OF STREET LIGHT WITH LED Percentage 1589804.64 1637498.78
B15 DEVLOPEMENT OF CHILDREN PLAY AREA AND PLAYING EQUIPMENT Percentage 853395.72 878997.59
B16 CONSTRUCTION WORK OF SHOPS. Percentage 1101122.35 1134156.02
O & M 1 Year Total (A1)
Sr. No. Description Unit Quantity Rate Per Amount for
1 Gardener/cleaning staff DSR horticulture Similar 0140 Mali Per Day 2.00 893.00
2 Watchman SOR IT No L009 Per Day 2.00 539.00
3 Supervisor L029 Per Day 1.00 767.00
Manpower O & M 1 Year Total (A2)
Sr. No. O & M Cost for 5 Year Year Amount
1 O & M Cost 1st Year (A2) 1st Year
2 O & M Cost 2nd Year (5% Increase from Previous Year) 2nd Year
3 O & M Cost 3rd Year (5% Increase from Previous Year) 3rd Year
4 O & M Cost 4th Year (5% Increase from Previous Year) 4th Year
5 O & M Cost 5th Year (5% Increase from Previous Year) 5th Year
Manpower O & M 5% Increase from Previous Year Total (A2)
O & M 1 Year Total (A1)
O&M Cost (A1 + Total for A2)
SBD SECTION-7 BILL OF QUANTITIES-
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ.pdf
OTHER IMPORTANT DOC-1.pdf
OTHER IMPORTANT DOC-2.pdf
OTHER IMPORTANT DOC-3.pdf
SBD SECTION 1 2 3.pdf
SBD SECTION 3 O AND M.pdf
SBD SECTION 4 and 5.pdf
SBD SECTION-5 TECHNICAL SPECIFICATION.pdf
SBD SECTION-5.1 ELECTRO-MECH SPECIFICATION.pdf
SBD SECTION-6 and 7.pdf
SBD SECTION-7 SCHEDULE-B.pdf
SBD SECTION-8 AND 9.pdf
SBD SECTION-9-Drawing.pdf
SBD SECTION-10.pdf
SBD SECTION-11.pdf
SBD SECTION-12 MAKE LIST.pdf
SBD SECTION-13 GENERAL SPECIFICATION.pdf
Download all tender documents and submit your bid