REPAIR MAINTENANCE OF CENTRAL AC PLANTS AND CONNECTED WORKS AT AF STN PHALODI
2024_MES_644533_3
88010/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF PHALODI
Asa per NIT
8 documents required · 8 mandatory
₹500
GE AF PHALODI
₹22,000
Yes
27 Jun 2024
7 May 2024
30 May 2024
7 May 2024
28 May 2024
14 May 2024
Amount
M&L for servicing, repair/maint and pressure test of the condensor and cooling coil of Chiller Package type Water cooled AC of 25 TO 50 TR (Refrigerant- R407C/R-22) capacity and dismantling the same for repair the leakage point by brazing/soldering including check and replacement of all unserviceable/burnt out electric/electronic part and rewiring of the unit and descalling by using antiscallent solution passing through copper tube of condensor units and connected pipes/tubes with suitable tools and pressure pumps, including apply two coat of enamle paint after removing rusting over the pipe of chiller and condensor pipe upto cooling tower and refrigerant pipes with two coats of enamel paint of the colours as indicated by Engr-in-Charge and identification symbols mentioning the service colour coded and the direction of flow of fluids in pipes by arrow at regular intervals shall also be marked, necessary repair/maint as required to plant complete, after completion of the entire job the plant testing will be conducted for 12 hours to the satisfaction level of Engr-in-Charge Make: Blue Star Notes: (a) Cost of requiste Tools & Plants, repairing, servicing other than electrical/electronic components, spares shall be deemed to be included to the quoted rate. (b) AC plant servicing, AHU servicing, defects rectification , testing and commissioning shall be got carried out through the Authorised Service Technicians only by the contractor under his own arrangements and expenses. (c) Cost of descaling chemicals, refrigerants, electrical/electronic components, spares shall be measured and paid for separately.
M&L for complete servicing and descaling of draft type cooling tower of FRP of capacity 50 to 100 TR complete with all accessories, basin, fittings & fan motor complete and replacement of PVC corrugated honeycomb double edge folded fills, PVC sprinkler pipe and its controlling system along with bottom side & top aluminium net protection and including Cleaning of makeup water tank ,painting to the pipes and parts of the plants as per colour codes as directed including necessary masonery work for supporting pillars of tower and pipes all as specified and directed by Engineer-in-Charge. Note:- PVC corrugated Honeycomb double edge folded fills of size 600x300x150 x 1.75mmshall be measured and paid for separately.
M&L for repair & servicing of Air Handling Unit parts complete ie Housing/Caping construction, Motor & Drive, Fan, Cooling coils,hot water tank painting and repair, filters & accessories including replacement of Fan Belts, unserviceable electric/electronic part of the unit, Clogged unusable Filters,hot water tank painting & repair, broken fan shaft pully, unserviceable cooling coils 12 mm dia, 24 G thick with aluminum fins of the AHU of 1000 to 16000 CFM, Model ZDS-160, Make ZECO, S/No 1. all as directed by Engineer-in-Charge.
M & L for repair & servicing of Hot Water Generater 54 kw , 415 volt including replacement of parts C T coil ,MCB, heating eliment, themostate Step control relay card & relay, contactor ,HRC fuse, power control card, push ON- OFF switch , complete circuit wiring, control switch, indicting lamp , presure meter,Electric Buzzer , PPS 5 VA complete all as specified and directed by Engr-in-Charge.
S&F in replacement aluminium Fan blade 53'' inch( three blade in one set) long for AC plant cooling tower as per sample complete all as specified and directed.
S&F in replacement aluminium Fan blade 56'' inch( three blade in one set) long for AC plant cooling tower as per sample complete all as specified and directed.
Supply cooling Tower PVC Corrugated Honeycomb double Edge Folded Fills for cooling Tower Size 600x300x150x0.175 mm. Corrugation depth 12 mm No of Layers - 12 Nos, Weight ~ 750 GM.complete all as specified and directed.
M&L for Taking down and servicing of Monoblock pump (Horizontal Type) upto 5 HP capacity, 3 phase, 415 V from central air conditioning plant, dismantling the pump, including replacement of unserviceable impellers, bearings, gland packings, and shaft and mechanical water seal as per manufacturer's specifications, greasing, servicing, reassembling complete and refitting at site complete all as specified and directed by Engineer-in-charge
M&L for Taking down and servicing of Monoblock pump (Horizontal Type) 5 to 12.5HP capacity, 3 phase, 415 V from central air conditioning plant, dismantling the pump, including replacement of unserviceable impellers, bearings, gland packings, and shaft and mechanical water seal as per manufacturer's specifications, greasing, servicing, reassembling complete and refitting at site complete all as specified and directed by Engineer-in-charge
M&L for rewinding the electric motor of capacity 10 to 12.5 HP by dismantling and removing the burnt out copper winding cleaning the slot of stator thoroughly and rewinding the stator with super enamelled copper winding wire of same gauge with proper class of insulation and applying varnish including re assembling all the parts of the motor, reinstallation in same position complete including testing and comissioning complete all as specified and directed.
M&L for rewinding the electric motor of capacity 5 to 10 HP by dismantling and removing the burnt out copper winding cleaning the slot of stator thoroughly and rewinding the stator with super enamelled copper winding wire of same gauge with proper class of insulation and applying varnish including re assembling all the parts of the motor, reinstallation in same position complete including testing and comissioning complete all as specified and directed.
M&L for rewinding the electric motor of capacity Upto 5 HP by dismantling and removing the burnt out copper winding cleaning the slot of stator thoroughly and rewinding the stator with super enamelled copper winding wire of same gauge with proper class of insulation and applying varnish including re assembling all the parts of the motor, reinstallation in same position complete including testing and comissioning complete all as specified and directed.
S&F in replacement contactor 3 pole with AC Coil 18 Amps 415 Volts fixed in existing panel. MAKE: C&S (TC) or equivalent as given in Appendix B.
S&F for replacement of contactor 3 pole with AC Coil 25 Amps 415 Volts fixed in existing panel. MAKE: MAKE: C&S (TC) or equivalent as given in Appendix B.
S&F in replacement contactor 3 pole with AC Coil 32 Amps 415 Volts fixed in existing panel. MAKE: Havells/L&T/SIEMENS/Legrand or equivalent as given in Appendix B.
S&F in replacement contactor 3 pole with AC Coil 40 Amps 415 Volts fixed in existing panel. MAKE: C&S/SIEMENSor equivalent as given in Appendix B.
S&F in replacement contactor 3pole with AC Coil 115 Amp 415 Volts fixed in existing panel, MAKE: C&S/indoasian/Legrand or equivalent as given in Appendix B.
S&F in replacement thermal overload relay (Auto/Manual Reset) setting range 7 to 10 Amps, power rating for 3 phase motor at 415V fixed in existing panel. MAKE: C&S/L&T/SIEMENS/Legrand or equivalent as given in Appendix B.
S&F in replacement thermal overload relay (Auto/Manual Reset) setting range 10 to13 Amps, power rating for 3 phase motor at 415V fixed in existing panel. MAKE: C&S/L&T/SIEMENS/Legrand or equivalent as given in Appendix B.
S&F in replacementthermal overload relay (Auto/Manual Reset) setting range 13 to 18 Amps, power rating for 3 phase motor at 415 V fixed in existing panel. MAKE: C&S/L&T/SIEMENS/Legrand or equivalent as given in Appendix B.
S&F in replacement thermal overload relay (Auto/Manual Reset) setting range 18 to 25 Amps, power rating for 3 phase motor at 415V fixed in existing panel. MAKE: Havells/L&T/SIEMENS/Legrand or equivalent as given in Appendix B.
S & F in replacement Add-on-Block(2NO/1NO+1NC) for contactors . Make: C&S or equivalent as given in Appendix B.
S&F in replacement Pressure Gauge suitable for Central Air Conditioning Plant complete all as specified and directed
S&F in replacement Thermometer suitable for Central Air Conditioning Plant complete all as specified and directed
S&F in replacement of MCB C Series TP 32 Amps fixed in existing Panel complete all as specified MAKE:Havells/L&T/LEGRAND or equivalent as given in Appendix B.
S&F in replacement of MCCB 125 Amps, 35 KA 3 pole 415 volt fixed in existing Panel complete all as specified MAKE:Indoasian Cat part no- N2-125M/3P , As per IS 60947-2/IS 13947-2
S&F in replacement Multicore round PVC insulated and FRLS PVC round sheathed copper conductor (Flexible) industrial cable 1100Volts 6 Sqmm 3 core complete all as specified and directed. Make: Havells/Finolex/Polycab or equivalent as given in Appendix B.
S&F in replacement Multicore round PVC insulated and FRLS PVC round sheathed copper conductor (Flexible) industrial cable 1100Volts 10 Sqmm 3 corer complete all as specified and directed. Make: Havells/Finolex/Polycab or equivalent as given in Appendix B.
S&F in replacement chiller plants PCB suitable for 26 to 50 TR capacity of existing model complete all as specified and directed. Make: Blue Star, Model: Micro Processor Control/ SP-DX-2C WC/3C WC/4C WC, CH12V4 & DXCPU1
Material and Labour for repair to leaking area of AC Plant of any capacity, including pressure testing, dehydration and gas charging R-407C complete all as specified and directed. Note :Empty/filled Ref gas cylinder shall be the responsibility of contractor and he shall be liable for all risk against the same and all costs deemed to be included in the quoted rate.
Material and Labour for repair to leaking area of AC Plant of any capacity, including pressure testing, dehydration and gas charging R-22 complete all as specified and directed. Note :Empty/filled Ref gas cylinder shall be the responsibility of contractor and he shall be liable for all risk against the same and all costs deemed to be included in the quoted rate.
S&F in replacement filter drier DFP-023Z0014 DCL 305 suitable for Ac plant complete all as existing specified and directed.
S&F in replacement Thermostatic Expansion valve suitable for AC plant complete all as existing specified and directed. Make : Danfoss or equivalent as given in Appendix B.
S&F in replacement LP/HP Switch suitable for AC plant complete all as existing specified and directed.
S&F in replacement temperature sensors suitable for Ac plant complete all as existing specified and directed.
S&F in replacement compressor crank case heater (CCH) suitable for Ac plant complete all as existing specified and directed.
S&F in replacement Pressure safety release valve (PRV) suitable for Ac plant complete all as existing specified and directed.
Supply and fill condensor,chiller,cooling tower descaling chemical grade CWM-300 suitable for AC Plant complete all as specified and directed.
Supply and fill compressor oil suitable for AC Plant complete all as specified and directed.
M&L of Servicing of package type ACs of any capacity including cleaning condenser and cooling coil with air blower to remove the impurities dust and foreign materials, cleaning of filters of suspended indoor unit, refixing the same after complete repair/servcing rewinding of fan motor with replacement of unserviceable parts and Carry out check necessary brazing work to copper tubing and charging the refrigerant as per existing/NON-CFC class complete for 8.5 ton capacity package type AC complete installed at Station Logistic Section all as specified and as directed by Engineer-in-Charge. (Note:-Gas for charging shall be measured and paid for separately)
S & F in replacement Damper Actuators - NON Spring Return Type Actuators Floating control, Model Number: CN4634A1001 34Nm,230V, IP54 Protection. Make: Honeywell or Equivalent or equivalent as given in Appendix B.
S&F in replacement heater elements of 2.0/2.5 Kw capacity as per site requirment.
M & L for servicing of Air Curtain 1 phase, 240 Volts, 50 Hz, 5 m throw range vertically downstream, velocity 12 to 18 m/sec - removing the major parts cleaning, checking the blower, shaft, blower motor, direction louvers, power supply refitting, testing and commissioning at Stn Logistics section all as specified and directed by Engr-in-Charge.
S&F in replacement of Y stainer fillter jali suitable for 80 to 125mm dia.
star electricals
S R ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .