Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.5 CrAccepted-AOC | ₹2.5 Cr | 1 | Accepted-AOC Accepted |
| 2 | 2₹3.1 Cr+₹58.3 L (22.9%)Rejected-Finance | ₹3.1 Cr+₹58.3 L (22.9%) | 2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
1 Apr 2021, 3:00 pmClosed
Hydraulic Engineer
Kalyan Dombivli Municipal Corporation, Shankarrao chowk, Kalyan(W)
Operation and Maintenance of Sewage treatment plants and Sewage Pumping Stations located at Titwala East and Titwala West for the period of Three years.
2021_KDMC_659655_1
KDMC/UGD/2020-21/18-2
Open Tender
Miscellaneous Services
Item Rate
1095 days
Kalyan Dombivli Municipal Corporation area
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,120
₹1.2 L
Chember of Hydraulic Engineer
28 Jun 2021
9 Mar 2021
5 Apr 2021
9 Mar 2021
1 Apr 2021
9 Mar 2021
16 Mar 2021
Amount
Operation and maintenance (Labour)
Providing senior Engineer (Electrical /Mechanical) for day to day electrical & mechanical maintenance along and overall running of pumping stations
Supplying electrical superviser for attending electrical preventive and breakdown work in 'G' Shift for pumping station
Supplying electrical Assitant skilled for attending electrical preventive and breakdown work in 'G' Shift for pumping station
Supplying Mechanical Assitant skilled for attending electrical preventive and breakdown work in 'G' Shift for pumping station
Providing pump operator (Skilled) one for each shift in three shift round the clock for operation of pumping stations
Supplying labour/Majdoor Skilled for day to day preventive maintenance , breakdown work work pumping stations
Supplying Security guard for pumping station round the clock etc complete
Supplying Gardner for maintaining garden developed on primary rector, secondary rector and primises of STP
Cost of Repair and Maintenance job work and spares for the two years
Sampling and testing of sewage inlet and out let prescribed parameters BOD , COD , TSS , PH , Phosporous, MLSS, TDS at existing ,labrotery by Lab Technician including necessary Chemicals and repairing / overhauling of existing eqipmetns and providing additional necessary test equipments / augmentation of test eqipments etc complete
Providing and supplying ISI mark unplastised PVC pipe including cost of couplers/rubber ring - 63 mm
Providing and supplying ISI mark unplastised PVC pipe including cost of couplers/rubber ring - 75 mm
Providing and supplying ISI mark unplastised PVC pipe including cost of couplers/rubber ring -90 mm
Providing and supplying ISI mark unplastised PVC pipe including cost of couplers/rubber ring - 110 mm
Lowering ,Laying & Jointning of unplastised PVC pipe and specials - 63 mm
Lowering ,Laying & Jointning of unplastised PVC pipe and specials - 75
Lowering ,Laying & Jointning of unplastised PVC pipe and specials - 90 mm
Lowering ,Laying & Jointning of unplastised PVC pipe and specials - 110 mm
Desilting the supply well intake well in wet or dry conditionby using proper safety devices and precautions etc complete .
Reparing / overhauling of sewage submersible pump up to 15 HP including removing from wet well reinstallation and replacement of mechanical seal , bearing , replacement of lubricating oil motor rewinding , cable , SS chain , guide pip , testing for air leakage and satisfactory performance test etc complete
Ultra Sonic Level Sensor - Providing and installing and giving satisfactory test , trial of ultrasonic flow meter Clamp on fix type with calibration and guarantee for 6 month and warantee for further 1 year perod etc complete
Ultra Sonic Flow Meter - Providing and installing and giving satisfactory test , trial of ultrasonic flow meter Channle Type depth up to 1.5 Mtr with calibration and guarantee for 6 month and warantee for further 1 year perod etc complete
Repairing / reinstallation of Ultrasonic flowmeter/channel meter / Level Sensor suitable for various dia pipes and giving satisfactory test , trial with calibration and guarantee for 6 month and warantee for further 1 year perod etc complete.(
Electrical Panel painting - Providing epoxy painting 2 coats of approved colour shade on provided iron /MS work etc complete .(PWD Elect DSR 2017-18 page 292 Item No 16-04-13)
Oil filtration of transformer. (PWD Elect DSR 2018-19 Pg no-301 It no- 17-3-1)
Supplying and topping filtered transformer oil with test certificate.(PWD Elect DSR 2018-19 Pg no-301 It no- 17-3-2)
Supplying & ereccting bank of all polypropyline condensors (APP) with standard capacities of 2,3,5,7,10,12.5 & 15 KVAR units of pf correction for operation on 3 phse 50 cycles 400/440 V ( 10 %) with external discharging resistence , earthing terminal and built on angle iron or channel iron framewok and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licency.
Supply SMPS based battery charger input voltage 230 V A/c and output voltage 24 DC charging current 20 A for DG set battery charging
Providing and supplying triple spur gear type chain pulley block suitable for 3 tonne capacity with testing etc complete (
Providing and supplying Ready Mix Oil Paint
Providing and supplying Ready Mix primer
Providing and supplying Ready Mix aluminum paint
Repairing of D.G. set upto 100 KVA capacity including minor & major repairs of alternator, engine,AMF panel, replacment of battery, engine oil etc.
Reapring of PLC panal of STP including SMPS cards,I/O cards,power supply, indicating lamps, relays, HMI units with software licenced key for 5 years etc. complete.
Reparing of MCC Panel including replacement of 630 A ACBb/ SFU / CT / MFM / incicating Lamp /MCB/Insulator etc Complete
Reparing of APFC Panel including replacement of Capacitor / APFC Relay / incicating Lamp /MCB/Insulator etc Complete
Repairing of MS / GI / DI pipe up to 300 mm dia /rectification of leakage by welding replacing of piece of pipe etc complete
Reparing/rewinding of upto 200 KVA 22 KV/433 V distribution transformer including H.V./L.V. coil rewinding, Oil replacement, H.T/L.T busing replacement, To and Fro transportation, testing etc. complete.
Repairing of Star-Delta starter upto 30 KW including replacement of contactor,auto transformer, timer, digital ammeter/voltmeter, protection replay, terminal block, SFU, wires, indicating lamp, pump protection relay etc. complete with satisfactory test.
Reparing of area light pole including 150 sodium fitting, choke,ignitor, wire,pole paiting, FRP junction box etc. complete.
Reparing of pathway light pole including 70 w sodium/LED fitting, choke,ignitor,driver, wire,pole paiting, FRP junction box etc. complete.
Reparing of single/double flouresent light fitting including 40 w tube , choke,capacitor, wire, FRP junction box,single/three pole MCB,cable etc. complete.
Supplying and erecting PVC armoured cable 3.5 core 35 sq mm aluminum conductor with continuous 5.48 sq mm (12 SWG) G.I.earth wire complete erected with glands and lugs on wall /trusses / pole or laid in provided trench/pipe as per specification CB -LT/AL .
Supplying and erecting PVC armoured cable 3.5 core 95 sq mm aluminum conductor with continuous 8.35 sq mm (12 SWG) G.I.earth wire complete erected with glands and lugs on wall /trusses / pole or laid in provided trench/pipe as per specification CB -LT/AL
Providing and erecting panel mounted digital Multi function Meter having three and half digit LED display, external C.T. operated, calibrated for 0-1000 A AC suitable to operate on 500 V AC supply with necessary PVC wire leads and lugs and mounting hardware on provide panel complete with calibration certificate from manufacturer.
Providing and fixing mild steel grill work for railing / shutter / staircase work of 20 kg/sqm
Supply T 5 28 W Energy Efficiant flurosant tube
Supply 18 W , 230 v intergral type LED lamp
Supply regular or standard model celling fan of 1400 mm sweep
Supplying and erecting CPCB approved online monitoring units for analysing treated water parameters BOD, COD, TSS, PH, NH4-N, N-total,PO4-P Sampling and testing of sewage inlet and out let Samples including MPCB Connectivity charges and maintainance alongwith technical expert and calibation of test eqipments and validation charges etc complete
M/s. Inderdeep Construction Company
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .