| 1 | L1₹9.9 LAccepted-AOC NADUVILPAT HOUSE KALLARAMANGALAM PO VIJAY ENGINEERING KADAMPUZHA MALAPPURAM PIN 676553 | MALAPPURAM | KERALA | 676553 | ₹9.9 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical 676521 | MALAPPURAM | KERALA | 676521 | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | SHAHUL HAMEED V L2 | RAJESH R L1 |
|---|---|---|---|---|---|
| 1.00ELECTRICAL | |||||
| 1.00 | OD332283/2025-2026:Supply and Installation of 6 kva Online UPS Input voltage range :170-270VAC Freaquency: 45Hz-55Hz Output voltage:230V Output frequency=50Hz Wave form=Pure Sinewave Protections: Advanced Electronic protection for device safety backed up with MCB?s/MCCB?s & fast acting fuses, high speed pulse to pulse electronic device protection over voltage/under voltage protection, Electronic over current trip Manual Bypass provided ,Inbuilt Isolation Transformer provided , with 150ah,12v Tubular Battery-10 nos and Battery Rack. Warranty: 3 year. Make.Hykon or equivalent. | 2 | each | 2,25,000 ₹4.5 L | 2,21,000 ₹4.4 L |
| 1.00 | OD332289/2025-2026:Supply, installation testing and commissioning of wall mounting 3 star 1.5Tr Inverter split air conditioner copper unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A /R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like ling,dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with sulation,control cable up to 5m, 3 m drain pipe, condenser stand, microprocessor control with cordless remote control, base frame etc. with one year warranty for machine and one year 4 Nos free service. 1.5 Tr single phase 3 Star rated Invertor Split copper convertable AC unit (O General/Voltas/ Blue star/Carrier/LG/ Samsung or equivalent) | 6 | each | 45,000 ₹2.7 L | 42,000 ₹2.5 L |
| 1.00 | OD332287/2025-2026:Supply and providing frame for the outdoor unit for1TR/ 1.5TR / 2 TR high wall split AC unit | 6 | each | 850 ₹5,100 | 850 ₹5,100 |
| 1.00 | OD332288/2025-2026:Supply and fixing 4 KVA voltage stabilizer V guard or equivalent for split inverter type AC with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off),Initial time delay, High and Low Voltage Cut Off, Micro-controlled operation, High temperature protection, indicators and chord wire etc.as required. | 6 | each | 2,850 ₹17,100 | 2,850 ₹17,100 |
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 35 | point | 1,450 ₹50,750 | 1,450 ₹50,750 |
| 1.01 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 15 | each | 500 ₹7,500 | 500 ₹7,500 |
| 1.01 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 16 | each | 610 ₹9,760 | 610 ₹9,760 |
| 1.01 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). | 20 | each | 710 ₹14,200 | 710 ₹14,200 |
| 1.01 | 2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way, Double door | 2 | each | 3,300 ₹6,600 | 3,300 ₹6,600 |
Updated dates
Tender Value
₹10.0 L
EMD Value
₹24,896
Closing Date
23 Oct 2025, 10:00 amClosed
Assistant Engineer
LID and EW Sub Division Kuttippuram Block Panchayath Thozhuvanoor PO PIN 676552
ELECTRICAL WORK
2025_LSGD_808700_1
D1/TN/06/25-26
Open Tender
Electrical Works
360 days
Kuttippuram BP
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,200
Yes
₹24,896
Yes
13 Jan 2026
13 Oct 2025
23 Oct 2025
13 Oct 2025
23 Oct 2025
13 Oct 2025
Amount
ELECTRICAL
OD332283/2025-2026:Supply and Installation of 6 kva Online UPS Input voltage range :170-270VAC Freaquency: 45Hz-55Hz Output voltage:230V Output frequency=50Hz Wave form=Pure Sinewave Protections: Advanced Electronic protection for device safety backed up with MCB?s/MCCB?s & fast acting fuses, high speed pulse to pulse electronic device protection over voltage/under voltage protection, Electronic over current trip Manual Bypass provided ,Inbuilt Isolation Transformer provided , with 150ah,12v Tubular Battery-10 nos and Battery Rack. Warranty: 3 year. Make.Hykon or equivalent.
OD332289/2025-2026:Supply, installation testing and commissioning of wall mounting 3 star 1.5Tr Inverter split air conditioner copper unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A /R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like ling,dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with sulation,control cable up to 5m, 3 m drain pipe, condenser stand, microprocessor control with cordless remote control, base frame etc. with one year warranty for machine and one year 4 Nos free service. 1.5 Tr single phase 3 Star rated Invertor Split copper convertable AC unit (O General/Voltas/ Blue star/Carrier/LG/ Samsung or equivalent)
OD332287/2025-2026:Supply and providing frame for the outdoor unit for1TR/ 1.5TR / 2 TR high wall split AC unit
OD332288/2025-2026:Supply and fixing 4 KVA voltage stabilizer V guard or equivalent for split inverter type AC with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off),Initial time delay, High and Low Voltage Cut Off, Micro-controlled operation, High temperature protection, indicators and chord wire etc.as required.
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
OD333675/2025-2026:Supply and fixing FP sheet steel enclosure and making connections etc as required
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.14:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 6.00 sq mm
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD333611/2025-2026:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthling system
OD333612/2025-2026:Supplying and Providing and fixing 25 mm X 3mm G.I. strip earth lead from the test joint to the earth plate
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
SHAHUL HAMEED V (BID ID -2403937)
Bidder Name
SHAHUL HAMEED V
RAJESH R
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1348775.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_1348775.xls
BOQ • 0.32 MB
26.rar
Other Document • 1.73 MB
Download all tender documents and submit your bid