Office of Incharge ERG
Office of I/c ERG, Oil and Natural Gas Corporation Ltd., Admin Building, ONGC, Hazira Plant, Surat-394518
Misc Electrical Works at Colony Ph1 and Ph2 and Bachelor Accommodation of ONGC Hazira Plant
2025_ONGC_252107_2
8P1GC25005
Open Tender
Electrical Works
Lump-sum
365 days
ONGC Surat
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹2.6 L
Yes
21 Nov 2025
28 Oct 2025
19 Nov 2025
28 Oct 2025
18 Nov 2025
28 Oct 2025
Miscellaneous electrical works for phase-I & II colony ONGC, Hazira, Surat.
Total Charges for the complete SOW for Miscellaneous electrical works for phase-I & II colony ONGC, Hazira, Surat.
Additional Notes to be read with price format/BOQ
All items of work included in the scope of work and other heads as stipulated in the Bidding Documents, design basis, drawings, specifications and to complete the subject work on Turnkey basis, irrespective of whether all the items of supply, erection and / or for any other activities are categorically listed out / brought out in the price Performa or elsewhere in the Bidding Document or not.
Mobilization, demobilization and all taxes including but not limited to corporate taxes, Personnel taxes, GST and insurances as per Bidding Document.
The quoted amount shall be inclusive of all the visits required to be performed by the bidder’s personnel in India / abroad in connection with the work including boarding, lodging, local conveyance charges, insurance charges towards persons working on site & material during its transportation.
All works, which are deemed to be performed, executed and supplied by the contractor for completion of works as stipulated in the Bidding Document and cost thereof is to be included. Nonfamiliarity and non- identification by the Vendor, of any works will not be considered as a reason either for extra claims or for not carrying out the work in strict conformity with drawings, specifications and instructions of Company Representative and Contract Document. Vendor should acquaint itself with the actual site conditions, make their own estimates of quantities and have to absorb all + variations in their quoted prices.
Price shall remain valid for the entire period of the contract. The price quoted shall be firm price (in Indian Rupees only) without any provisions for escalation. Total payments to be made to the Contractor shall be in Indian Rupees and limited to quoted and accepted total price or adjusted contract price as per the provisions of the contract.
Bidders are required to ascertain themselves, the prevailing rates of GST (Central or State), if any in addition to any other statutory levies as applicable on the scheduled date of submission of Price bids/revised price bids (if any) and ONGC would not undertake any responsibility whatsoever in this regard.
In accordance with the GST Law, GST shall be payable. Hence Bidders should quote giving complete break-up of GST component separately as per the Price Schedule Format , in their price bid, failing which their offers shall be rejected straightaway.
The amount of GST indicated by the Bidder in the "BoQ1" shall be the ceiling for payment by ONGC for respective scope of work at the rate prevailing on the date of bid closing except that any revision of rates due to legislative changes shall be governed by the relevant clause (Change in Law) of General Terms and Conditions of Contract. The payment towards GST indicated by the Bidder shall be made against submission of documents to the extent of GST Tax shown in the Invoice(s).
Bidder shall provide all the necessary compliances / Invoice / documents for enabling ONGC to avail Input tax credit benefits, in respect of the payments of GST which are payable against the contract. (GST registration number of ONGC, Hazira Plant Surat is 24AAACO1598A4ZQ; PAN No:AAACO1598A).
SUB: ESTIMATED SCHEDULE OF RATES (ESOR)
NAME OF THE WORK: MISCELLENOUS ELECTRICAL WORKS FOR PHASE--I &II COLONY ONGC,HAZIRA,SURAT.
A. Wiring for Phase-II colony with multi strand copper wires in existing pipe.
ONGC Estimated Rates
Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multi strand copper wires upto max length of 10 mt, in below type of pipe erected with 6A Tissino Type ISI marked flush type switch / bell push and accessories erected on Metal / PVC/Wooden Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (e) in existing pipe erected concealed in wall/ceiling complete (a) A-type Quarter phase-II = 2728 (b) B-type Quarter phase-II = 2708 © C-type Quarter phase-II = 390 (d) D-type Quarter phase-II = 108 (e )Community Hall phase-II = 208 (f) Shopping Centre Ph-II= 67 Total point = 6209
Point wiring for on board looped PLUG (same board) with tissino type single pole ISI marked Switch and Socket erected with necessary connections erected on wooden /Metal/ PVC Box covered with 3 mm thick PC(Polycarbonate) /Acrylic sheet for open / concealed wiring for following size. For 5/6Amp (a) A-type Quarter phase-II = 880 (b) B-type Quarter phase-II = 1088 © C-type Quarter phase-II = 194 (d) D-type Quarter phase-II = 36 (e )Community Hallr phase-II = 56 (f) Shopping Centre Ph-II= 24 Total point = 2278
Point wiring for independent PLUG/AC point with with 6/16A Plug and 16 amp switch with 2-2.5 sq. mm Cu. Mains from MCBDB to boards both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires upto 10 mt length, in following below of pipe/cassing capping erected complete with ISI marked 6/16A socket and tissino type switch erected with earth continuity connection erected on Metal / PVC/Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic/Laminated sheet. [B] 6/16A Plug and 16 amp switch with 2-2.5 sq. mm Cu. Mains from mcb d b boards. ( C) with oval conduit /PVC casing capping double lock type erected flushed on wall/ceiling complete (a) A-type Quarter phase-II = 176 (b) B-type Quarter phase-II = 240 © C-type Quarter phase-II = 32 (d) D-type Quarter phase-II = 4 (e )Community Hallr phase-II =15 (f) Shopping Centre Ph-II= 4 TOTAL point =471
Point wiring for independent PLUG/TV point with following size mains earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires upto 10 mt length, in following below of pipe erected complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with earth continuity connection erected on Metal / PVC/Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic/Laminated sheet. (j) in existing pipe erected erected concealed in wall/ceiling complete (a) A-type Quarter phase-II = 176 (b) B-type Quarter phase-II = 240 © C-type Quarter phase-II = 32 (d) D-type Quarter phase-II = 4 (e )Community Hall phase-II = 56 (f) Shopping Centre Ph-II= 16 TOTAL point = 524
Point wiring for independent PLUG point with 6/16A Plug and 16 amp switch with 2-2.5 sq. mm Cu. Mains from MCBDB to boards both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires upto 10 mt length, in following below of pipe/cassing capping erected complete with ISI marked 6/16A socket and tissino type switch erected with earth continuity connection erected on Metal / PVC/Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic/Laminated sheet. (j) in existing pipe erected concealed in wall/ceiling complete as required. (a) A-type Quarter phase-II = 352 (b) B-type Quarter phase-II = 360 © C-type Quarter phase-II = 32 (d) D-type Quarter phase-II = 4 (e )Community Hallr phase-II = 7 (f) Shopping Centre Ph-II= 24 Total point =779
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in following type of pipe to be erected concealed in / flushed on wall / ceiling complete with 6A Tissino Type ISI marked accessories with earth continuity erected on Metal/PVC//Wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (e) in existing pipe erected flushed on wall/ceiling complete (a) A-type Quarter phase-II = 264 (b) B-type Quarter phase-II = 264 © C-type Quarter phase-II = 54 (d) D-type Quarter phase-II = 10 (e )Community Hall Staircase, phase-II = 4 (f) Shopping Centre Ph-II= 0 Total point =568
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (E) In existing Pipe © 3 wire 1.5 Sq.mm (a) A-type Quarter phase-II = 880 (b) B-type Quarter phase-II =1320 (c ) C-type Quarter phase-II = 185 (d) D-type Quarter phase-II =100 (e )Community Hallr phase-II = 945 (f) Shopping Centre Ph-II= 70 TOTAL= 3500
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (E) In existing Pipe ( C) 3 wire 2.5 Sq.mm (a) A-type Quarter phase-II = 3520 (b) B-type Quarter phase-II = 3600 (c ) C-type Quarter phase-II = 640 (d) D-type Quarter phase-II =230 (e )Community Hallr phase-II = 350 (f) Shopping Centre Ph-II= 141 TOTAL = 8481
Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multi strand copper wires upto max length of 10 mt, in below type of pipe erected with 6A Tissino Type ISI marked flush type switch / bell push and accessories erected on Metal / PVC/Wooden Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed. (h) with oval conduit/PVC cassing capping double lock type errected on wall/ceiling , complete as required (additional exhoust fan point for C-type Qtr. At phase-II.
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (b)Sheet steel double door (IP-43). Single phase incoming and horizontal single phase outgoing 12 way double door MCB DB = Rs. 1742.00 Providing & erecting 240 V MCB double pole switch (ELCB) for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having capacity 40A. Cost of 1 no ELCB =Rs.385.00 providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark 6A to 20A SP MCB -Cost of one no MCB= Rs.130/- Total cost of one No of double door MCB DB with one no 40A single Phase ELCB and 10 no single pole MCB( 20A-5no and 10A-5 no)= 20A MCB =5x130/- + 10A MCB 5x130 =Rs.1300/- Total cost of double door horizontal MCBD-1 no,ELCB-1no, SP MCB 20A-5 no and SPMCB 10A-5 no= Rs.1742 +385+5x130 +5x130= Rs.3427.00 (a) A-type Quarter phase-II =176 (b) B-type Quarter phase-II = 120 © C-type Quarter phase-II = 32 (d) D-type Quarter phase-II = 2 (e )Community Hall phase-II = 2 TOTAL= 332
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (B) Three phase incoming and single phase horizontal type outgoing per phase isolation type(PPI). (b)Sheet steel double door (IP-43). Single phase incoming and horizontal single phase outgoing (iv) 16 way DB -1 no for shopping centre
Providing & erecting 240 V MCB Four pole switch for lighting Load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark 6A to 20A SP MCB -Cost of one no MCB= Rs.130/- 20A SP MCB
Providing and fixing Sheet steel double door (IP-43),16 way DB for community Centre
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 63Amp
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 20A SP MCB
Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long 'B' grade G.I. pipe with necessary coupling buch buried in specially prepared earth pit & G.I. earth wire of 8 SWG erected & connected as directed (For panel) (a) A-type Building phase-II = 11 (b) B-type Quarter phase-II = 08 (c ) C-type Quarter phase-II = 2 (d) D-type Quarter phase-II =2 (e )Community Hallr phase-II = 4 (f) Shopping Centre Ph-II= 2 (g) Feeder Pillar =5 for Phase- II colony. Total = 34 (New)
(i) For using salt and charcoal / coke as required for pipe type earthing.
Rupees One crore Thirty One Lakh Thirteen Thousand Eight Hundred and Eighty Nine only
(iii) Add Extra for excavation in Hard rock by dry and wet blasting and chiselling for pipe type earthing.
Percentage Less/Excess to be filled in BoQ Price format
(ii) Add Extra for excavation in Semi hard rock (Murrum) by dry and wet blasting and chiselling for pipe type earthing
Supplying & erecting single phase approved make industrial exhaust fan suitable for use in Kitchen, medium duty ring mounted low noise operation suitable for medium duty having following dia size and
(iv) Providing and erecting Annealed bare Copper wire 8 to 16 SWG and connecting the same with existing earthing pipe of building.
Sq.Mtr
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [B] 380 mm dia 900 RPM, Cat.II Badminton Hall Sports Centre,Phase-I colony
Supplying and erecting horizontal / vertical mounting type storage water heater with copper container housed in M.S./S.S. body insulated with glass wool / puff complete with heating elements,adjustable thermostats 300C to 850C, indicating lamp, safety valve, fusible plug, etc.complete erected with coach bolts, nuts. washers & cementation (A) 10 Ltr. with 3 KW. heating element (a) A-type Quarter phase-II =176
Supplying and erecting horizontal / vertical mounting type storage water heater with copper container housed in M.S./S.S. body insulated with glass wool / puff complete with heating elements,adjustable thermostats 300C to 850C, indicating lamp, safety valve, fusible plug, etc.complete erected with coach bolts, nuts. washers & cementation (B)15 Ltr-.with 2 /3K.W. heating element (b) B-type Quarter phase-II = 120 (d) D-type Quarter phase-II = 2 Total = 122 no
Supplying and erecting horizontal / vertical mounting type storage water heater with copper container housed in M.S./S.S. body insulated with glass wool / puff complete with heating elements,adjustable thermostats 300C to 850C, indicating lamp, safety valve, fusible plug, etc.complete erected with coach bolts, nuts. washers & cementation (C)25 Ltr. with 2 KW. heating element (a) C-type Quarter phase-II = 16 (b) D-type Quarter phase-II = 2 Total = 18 no
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner.
Providing of approved make, 150 mm Sweep, Polypropylene blade, moluded cabinet & Louver shutter, 230 Volt AC Exhaust Fan erected on the wall making suitable hole/ existing ventilators in Bathroom/toilet and all accessories including, installation ,testing and commissioning and removing the obstruction of any type if required for installation of exhaust fan. (a) A-type Quarter phase-II =176 (b) B-type Quarter phase-II = 120 © C-type Quarter phase-II = 16x2=32 (d) D-type Quarter phase-II = 4 Total=332 no
B. STREET LIGHT PHASE-II & PHASE-I COLONY
Supplying & erecting Galvanized M.S pipe post “B” class 88.9 mm O.D 4 mtr. Long duly painted with two coats of aluminium paint complete with metallic base plate of 300 mm x 300 mm x 4mm thick for using as a compound light pole with approx. weight 32 Kg. For Phase-II colony boundary
Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole) For Phase-II colony (At boundary)
(v) providing and erecting Cast iron earth plate size 30 X 30 X 0.35 cms. buried in specially prepared 2.5 Mtr. deep earth pit complete with PCC earth chamber and necessary G.I. wire in G.I. pipe 2 Mtr. long with coupling and G.I. plug for earthing of switch gear, conduit run or power plug etc.(For Phase-I & II i/c replacement of broken one).
Supplying & erecting electro galvanised G.I. wire micro mesh jali cover of grade 304 required size with suitable wooden frame duly fitted in wall outside of exhaust fan for insect protection.
(i) pole as per IS code 410-SP-4 with 300 X 300 X 4 mm base plate. (Approximate Pole weight 67 Kg) For burial erection
(ii) Add Extra for M.S. Base plate 300 X 300 X 16 mm for pole, Suitable for mounting on surface of foundation with foundation bolts, with required stiffeners welded with pole.
d/soft soil for loosen the cables for re-connection to the New feeder panel including cable joint,nut-bolt,cable gland and other materials etc as required to be supplied and installed as per site requirement. Item dismentalled to be handed over to colony Elect. Maint.
(iii) Add Extra for PU base primer and PU Paint on pole.
(B) Errection of Feeder panel on New brick foundation/pillar: The feeder panel will be rest on two brick pillars.The base of the brick pillar below ground will be (i)60 cm x 40 cmx20 cm (LxBxH) and above ground will be (ii) 45 cmx30 cmx60 cm (LxBxH) above ground level including plastering and duly painting.Two no M.S angle (50 x50 x6)mm will be provided and placed at horizontal position connecting pillar to pillar to support the panel to rest on the middle of both base pillar. The work includes, dismentling the existing feeder pillar including dismentling all cable connection,excavation and digging of hard/semi har
(iv) Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 60 x 60 x 120 cm. Deep in below ground level with plinth of 45 cm x 45 cm(or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner. ( for 7.5 & 8/8.5 mtr pole)
(a) 300mm x 200mm x 100mm [deep] Phase-II TOTAL =35
[C] Triple Arm Bracket 1.5 Mtr For Phase-II
[A] Single Arm Bracket 1.5 Mtr Phase-II
[D] Four/five Arm Bracket 1.5 Mtr for Phase-II
(B) 50 mm dia
(A) Errection of Feeder panel on existing brick pillar:Feeder panel to be errected in the existing place and existing position in existing brick foundation including repairing, plastering and making good enough the foundation to carry the load of Panel and its accessories as required.Foundation to be approved by EIC before placing the pannel on the repaired foundation. The work includes, dismentling the existing feeder pillar including dismentling all cable connection,excavation and digging of hard/semi hard/soft soil for loosen the cables for re-connection to the New feeder panel including cable joint,nut-bolt,cable gland and other materials etc as required to be supplied and installed as per site requirement. Item dismentalled to be handed over to colony Elect. Maint.
R/C Phase-I, For KV Stage
(B) Flood Light (IP-65), Surge protection -4KV integral and Light must have 440VAC line supply with over-voltage protection. (i) 250 Watts Phase-I & II, Cat-III (For Phase-I & II for 12 M pole), 6 pole, 30 no For main gate Phase-I & II and Shopping centre Phase-I - 05 no fittings 5 no. TOTAL=35
(C) Post Top Lantern complete fitting and with LED Lamp, comprises of finish cast aluminum spigot and spun aluminum canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting driver and accessories wired upto terminal block.IP 65 (ii) 32-40 W , Cat-III for Phase-I & II
[B] Double Arm Bracket 1.5 Mtr Phase-II
Supplying following size of Light duty “A” Class G.I . Pipe & erecting as directed by Engineer-in-charge. (For Phase-II colony)
Providing & erecting 240 V MCB Four pole switch for lighting Load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (b) 40 Amp
(a) Supply of material for painting by cleaning, the surface and applying one coat of primer and two coats of enamel paint for meter cup-board,shutter door,Transformer fencing,DG Shed of Phase- II or base plate suitable to match the wall finish
© Painting of street light pole with bracket complete with two coats of Aluminium paint for following size of pole. [c] up to 9 mtr
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables
(A) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) ( Feeder to C-1 building and Feeder to feeder inter link)
(E) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) ( For Central ground DB to G.H corner upto DB of Tapi bridge.)
(F ) 3.5 Core 35 Sq.mm ( Street lighting) From DB (corner of G.H) to Tapi Bridge.
(G) 4 Core 16 Sq.mm ( Power connection to 30 no ST. Light pole at phase-II boundary & 06 no Fl.Light pole and 10 no PL fittings including exixting defective cable if any.
(i) Upto 35 sq.mm
(ii) Above 35 sq.mm and upto 95 Sq.mm
(H) (i) 4 Core 25 Sq.mm (Power connection to KV Stage) & for D-29 to D-24 (ST.Light Power Supply). 120 Mtrs & (ii) KV Stage= 35 Mtr
(iii) Above 95 sq.mm and upto 185 Sq.mm
(d) 2 to 4 core 16 Sq. mm
(A) 3 & 1/2 / 4 core 25 Sq. mm
(B) 3 & 1/2 core 35/50 Sq. mm
(C) 3 & 1/2 core 70 Sq. mm
(A) Laying of one no PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of folloeing size direct in ground including excavation,sand cushioning,protective brick covering and refilling the trench etc as required
(E) 3 & 1/2 core 120 Sq. mm
(C) 16/25 Sq.mm.
(D) 35/50 Sq.mm.
(E) 70 Sq.mm.
(G) 120 Sq.mm.
Supplying and erecting approved make Pedestal Circulatory fan A.C. 230 V. 50 Cy/s. 600 mm sweep and adjustable height complete with guard, & standard lead flexible wires and plug top. (a )Community Hall phase-II = 10
Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole should be as per IS and shall be coated with hot dip galvanizing as per IS 2629/2634/4759, suitable suspend local wind speed with integral junction box consists of terminal plate of minimum 6mm Hylam sheet, standard profile 35mm x 7.5 mm Din-rail for MCB Mounting, stud type terminal and arrangement for cable termination to be erected with existing/suitable foundation (included) as per details given by manufacturer considering site requirement.The foundation to be minimum 20 cm above ground. The Four/five no fittings to be installed in Four side of the pole including bracket and base plate complete in all respect without luminaries. (H) 12 Mtr. Long 90 mm Top X 240 mm bottom dia, 4 mm thickness with 320mmX320mmX20mm base plate, 4-M24 Bolts and 850mm long J-Bolt.Approx pole weight 230 Kg.( 03 no each at Phase-I & phase-II colony)
Repair,maintenance of all energy meter box of phase-II colony including repairing of doors and making locking arrangement. (i) A-Type Phase-II - 44 no (ii) B-Type Phase-II -
32 no (iii) C-Type Phase-II - 4 no Total = 68 no
TOTAL ESTIMATED BASIC COST INCLUDING GST @18%
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.39 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.16 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender_documentsG.rar
Tender Documents • 4.82 MB
BOQ_291665.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .