Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-Finance | L1 | Accepted-Finance Lowest | |
| 2 | L2₹9.3 L+₹230 (0.02%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹9.4 L+₹3,866 (0.41%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹9.5 L+₹16,566 (1.78%)Rejected-Finance G 4 106 107 1ST FLOOR SECTOR 11 ROHINI NEW DELHI 110085 | NORTH WEST | DELHI | 110085 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹9.5 L+₹17,919 (1.92%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹9.7 L
EMD Value
₹19,455
Closing Date
10 Feb 2022, 6:00 pmClosed
Asstt General Manager (EE)
O/O Airport Director, Airports Authority of India, Civil Enclave, Jodhpur
Provision of Split AC for NAV Aids and other locations at Civil Enclave, Jodhpur
2022_AAI_101279_1
AAI/JOD/ENGG(E)/WE-124
Open Tender
Electrical Works
Works
90 days
Jodhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,180
₹19,455
23 Mar 2022
11 Jan 2022
12 Feb 2022
12 Jan 2022
10 Feb 2022
12 Jan 2022
12 Jan 2022 - 21 Jan 2022
Amount
Supply of 5 star rated energy efficient, 1.5 TR , single phase, wall mounting type split Air conditioner unit, consisting of indoor unit, out door unit, cordless remote control, refrigerant gas, standard length of refrigerant pipe, drain pipe, power cable etc. suitable for operation on 230 V, 50 HZ, 1-Ph AC supply capable of performing (a) Cooling (b) Dehumidifying (c) Air-circulating (d) filtering. The unit shall be auto-restart type without changing of existing settings etc. as per OEM standard and complete as required as per technical specifications Make Hitachi, (Model No:- RSB518HBEA) or equivalent.
Supply of 5 star rated energy efficient, 2 TR , single phase, wall mounting type split Air conditioner unit, consisting of indoor unit, out door unit, cordless remote control, refrigerant gas, standard length of refrigerant pipe, drain pipe, power cable etc. suitable for operation on 230 V, 50 HZ, 1-Ph AC supply capable of performing (a) Cooling (b) Dehumidifying (c) Air-circulating (d) filtering. The unit shall be auto-restart type without changing of existing settings etc. as per OEM standard and complete as required as per technical specifications Make Hitachi, (Model No:- RMB524HBEA) or equivalent.
Supply of 3 star rated energy efficient, 2 TR , single phase, wall mounting type split Air conditioner unit, consisting of indoor unit, out door unit, cordless remote control, refrigerant gas, standard length of refrigerant pipe, drain pipe, power cable etc. suitable for operation on 230 V, 50 HZ, 1-Ph AC supply capable of performing (a) Cooling (b) Dehumidifying (c) Air-circulating (d) filtering. The unit shall be auto-restart type without changing of existing settings etc. as per OEM standard and complete as required as per technical specifications Make Hitachi, (Model No:- RMI324HBEA) or equivalent.
Supply of 3 star rated energy efficient, 2 TR , single phase, wall mounting type split Air conditioner unit, consisting of indoor unit, out door unit, cordless remote control, refrigerant gas, standard length of refrigerant pipe, drain pipe, power cable etc. suitable for operation on 230 V, 50 HZ, 1-Ph AC supply capable of performing (a) Cooling (b) Dehumidifying (c) Air-circulating (d) filtering. The unit shall be auto-restart type without changing of existing settings etc. as per OEM standard and complete as required as per technical specifications Make Hitachi, (Model No:- RMI324HBEA) or equivalent.
Supply of 4 TR nominal capacity Cassette type Split Air conditioner with cooling function and fitted with hermetically sealed scroll compressor, operating on refrigerant R-32 / R-410 Non CFC suitable for ceiling mounted, operation on 415 V, 50 Hz three phase AC supply complete with Indoor, outdoor units, cordless remote and other accessories as per OEM standard complete as required Make Hitachi, (Model No:- RAG048HYDA3) or equivalent.
Installation of 1.5 TR / 2 TR Single phase wall mounted type split Air conditioner including installation of indoor unit on wall as per manufacturer recommendations, installation of outdoor unit with providing stand dully powder coated suitable for 1.5 TR / 2 TR AC outdoor unit, connection of suction and return pipes, drain pipes, electrical connections of indoor and outdoor units, first refill of gas, testing & commissioning etc. complete as required.
Installation of 4 TR nominal capacity cassette type Split Air conditioner including hanging of indoor unit from ceiling as per manufacturer recommendations, installation of outdoor unit, connection of suction and return pipes, drain pipes, electrical connections of indoor and outdoor units, first refill of gas, testing & commissioning, including cutting of false ceiling and making support and fixing of false ceiling on supporting members etc. complete as required.
Providing and fixing of copper refrigerant suction & liquid piping set for 1.5/2 TR Split AC including insulation, supports, clamps, fittings, connections, sleeves, insulation etc. in addition to standard length supplied with AC unit complete as required as per site conditions.
Providing and fixing of copper refrigerant suction & liquid piping set for 4 TR cassette AC including insulation, supports, clamps, fittings, connections, sleeves, insulation etc. in addition to standard length supplied with AC unit complete as required as per site conditions.
Supply and fixing 3 C x 2.5 Sq. mm PVC insulated , PVC sheathed unarmoured multi stranded copper cable to connect indoor and outdoor units of 1.5 TR & 2 TR AC units extra after standard length of 10 ft. complete as required as per site conditions.
Supply and fixing 5 C x 2.5 Sq. mm PVC insulated, PVC sheathed unarmoured multi stranded copper cable to connect indoor and outdoor units of 4TR, 3 phase AC unit complete as required as per site conditions.
Supply and fixing of angle iron stand dully powder coated suitable for 4 ton cassette type AC outdoor unit complete as required.
Providing & fixing of 25 mm medium mechanical stress, FRLS, CPVC Drain piping from indoor to nearest drain complete with fittings, supports etc. complete as required as per site conditions.
Supply and fixing of following size ISI marks PVC Pannel Trunking of standard slot complet as required as per site conditions (Make : precision or equivalent).
PVC Pannel Trunking 50mm x 50mm
PVC Pannel Trunking 75mm x 75mm
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Dismantling of existing 1.5TR / 2TR single phase, wall mounted type split ACs including indoor and outdoor units, stand, stablizer, refrigerant pipe etc. complete as required as per site conditions and shifting the material from site to AAI store.
VOLKS ENERGIE PVT LTD
NIRMAN ELECTRIC STORE
AQUATICS ENIGINEERS
vinayak cooling services
Anoop Refrigeration
ANU ENGINEERING CORPORATION
Navyug Engineering
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .