Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.0 L+₹16,200 (0.71%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹31.4 L+₹8.6 L (37.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹32.4 L+₹9.6 L (42.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹40.8 L+₹17.9 L (78.6%)Rejected-Finance DURGA NAGAR CHECK POST PO ETHELBARI DIST ALIPURDUAR PIN 735204 WB | ALIPURDUAR | WEST BENGAL | 735204 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
24 Dec 2021, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI BINNAGURI CANTT
CLEANING OF OVER HEAD TANKS AND MAINTENANCE OF CHLORINE DOSING PUMP AND REPAIR TO DG SETS AND ALLIED WORKS AT VARIOUS PUMP HOUSE UNDER GE SOUTH BINNAGURI
2021_MES_488734_2
8010/BIN(S)/33/21-22
Open Tender
Civil Works - Others
Item Rate
120 days
Binnaguri Military Station
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH BINNAGURI
₹84,000
Yes
17 Feb 2022
14 Dec 2021
25 Dec 2021
14 Dec 2021
24 Dec 2021
14 Dec 2021
Amount
Schedule 'A'
Taking out of the unseviceable / repairable parts from the engine with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as and when required suitable for Cumins / Kirloskar Engine) installed at various E/M installation and all as directed. (a) LO Filter element. as per existing make and model.
(b) Pre Filter element .as per existing make and model.
(c) Micro Filter Element. as per existing make and model.
(d) V Belt as per existing make and model.
(e) HOSE Pipe as per existing make and model.
(f) STOP SOLENOID as per existing make and model.
(g) Lube oil pressure sensor as per existing make and model.
(h) Sensor unit for Elec Temp Gaug,as per existing make and model.
(i) Electrical Lub Oil pressure Gauge as per existing make and model.
(j) OFF/ON Start Switch as per existing make and model.
(k) Thermostate Element as per existing make and model.
(l) FUEL PIPE as per existing make and model.
(m) Replacement of aircleaner element inner & outer as per existing make and model.
DG SET OF CAPACITY 200 KVA Taking out of the unseviceable / repairable parts from the engine with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as and when required suitable for Cumins / Kirloskar Engine) installed at various E/M installation and all as directed. (a) LO Filter element. as per existing make and model.
(b) Pre Filter element .as per existing make and model.
(c) Micro Filter Element. as per existing make and model.
(d) V Belt as per existing make and model.
(e) Hose pipe as per existing make and model.
(f) STOP SOLENOID as per existing make and model.
(g) Lube oil pressure sensor as per existing make and model.
(h) Sensor unit for Elec Temp Gaug, as per existing make and model.
(i) Electrical Lub oil pressure Gauge as per existing make and model.
(j) OFF/ON Start switch as per existing make and model.
(k) Thermostate Element as per existing make and model.
(l) FUEL PIPE as per existing make and model.
(m) Replacement of aircleaner element inner & outer as per existing make and model.
DG SET OF CAPACITY 25 to 30 KVA Taking out of the unseviceable / repairable parts from the engine with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as and when required suitable for Cumins / Kirloskar Engine) installed at various E/M installation and all as directed. (a) LO Filter element. as per existing make and model.
(b) Pre Filter element .as per existing make and model.
(c) Micro Filter Element. as per existing make and model.
(d) V Belt as per existing make and model.
(e) HOSE Pipe as per existing make and model.
(f) STOP SOLENOID as per existing make and model.
(g) Lube oil pressure sensor as per existing make and model.
(h) Sensor unit for Elec Temp Gaug,as per existing make and model.
(j) Electrical Lub Oil pressure Gauge as per existing make and model.
(k) OFF/ON Start Switch as per existing make and model.
(l) Thermostate Element as per existing make and model.
(m) FUEL PIPE as per existing make and model.
(n) Replacement of aircleaner element inner & outer as per existing make and model.
DG SET OF CAPACITY 320KVA Taking out of the unseviceable / repairable parts from the engine with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as and when required suitable for Cumins / Kirloskar Engine) installed at various E/M installation and all as directed. (a) LO Filter element. as per existing make and model.
(b) Pre Filter element .as per existing make and model.
(c) Micro Filter Element. as per existing make and model.
(d) V Belt as per existing make and model.
(e) HOSE Pipe as per existing make and model.
(f) STOP SOLENOID as per existing make and model.
(g) Lube oil pressure sensor as per existing make and model.
(h) Sensor unit for Elec Temp Gaug,as per existing make and model.
(i) Electrical Lub Oil pressure Gauge as per existing make and model.
(j) OFF/ON Start Switch as per existing make and model.
(k) Thermostate Element as per existing make and model.
(l) FUEL PIPE as per existing make and model.
(m) Replacement of aircleaner element inner & outer as per existing make and model.
Removing old coolant from radiator completely & changing with new coolant as per required capacity complete all as directed.
Removing of old Kirloskar oil from the Engine completely and changing with new Kirloskar oil (15 W 40) as per required capacity complete all as directed.
Material and labour for cleaning of silencer pipe and removing of ropes and re-fixing of new ropes of 25 KVA to 30 KVA DG Sets all as specified and directed.
Material and labour for cleaning of silencer pipe, and removing of ropes and re-fixing of new ropes of 50 KVA to 75 KVA DG Sets all as specified and directed.
Material and labour for cleaning of silencer pipe and removing of ropes and re-fixing of new ropes 200 KVA DG Sets all as specified and directed.
Material and labour for cleaning of silencer pipe and removing of ropes and re-fixing of new ropes 320 KVA DG Sets all as specified and directed.
Taking down of Radiator from the 25 tO 30 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc by using K clean solution to remove containminent like scale, oil, grease, rust, loose material and blow pressurized gas through radiator fins in opposite direction to clean air path blockage & refixing the same to its existing position complete all as specified and directed.
Taking down of Radiator from the 50 tO 75 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc by using K clean solution to remove containminent like scale, oil, grease, rust, loose material and blow pressurized gas through radiator fins in opposite direction to clean air path blockage & refixing the same to its existing position complete all as specified and directed.
Taking down of Radiator from the 200 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc by using K clean solution to remove containminent like scale, oil, grease, rust, loose material and blow pressurized gas through radiator fins in opposite direction to clean air path blockage & refixing the same to its existing position complete all as specified and directed.
Taking down of Radiator from the 325 KVA DG Set including connected hose pipe etc and cleaning thoroughly all the tubes and fins etc by using K clean solution to remove containminent like scale, oil, grease, rust, loose material and blow pressurized gas through radiator fins in opposite direction to clean air path blockage & refixing the same to its existing position complete all as specified and directed.
Repair/Overhauling of Alternator by removing the Exciter Unit, re-winding the week coil with super enamelled copper wire with proper turn as per the manufacutures instruction to achieve adequate voltage and PF with rated R.P.M including supply and fixing of both end bearing as per the existing and necessary spaires ie capacitor/carbon brush ectc.and other materials, heating vernishing the coil, re-fixing the item in proper position and testing on Load for 25 KVA to 30 KVA DG set.
Repair/Overhauling of Alternator by removing the Exciter Unit, re-winding the week coil with super enamelled copper wire with proper turn as per the manufacutures instruction to achieve adequate voltage and PF with rated R.P.M including supply and fixing of both end bearing as per the existing and necessary spaires ie capacitor/carbon brush ectc.and other materials, heating vernishing the coil, re-fixing the item in proper position and testing on Load for 75 KVA DG set.
Repair/Overhauling of Alternator by removing the Exciter Unit, re-winding the week coil with super enamelled copper wire with proper turn as per the manufacutures instruction to achieve adequate voltage and PF with rated R.P.M including supply and fixing of both end bearing as per the existing and necessary spaires ie capacitor/carbon brush ectc.and other materials, heating vernishing the coil, re-fixing the item in proper position and testing on Load for 200 KVA DG set.
Dismantling unsv control panel assembly for 200 KVA DG Set and supply & fix new control panel assembly incl wiring harness from engine to control panel, between engine, engine to alternator complete all as specified & directed by engr in charge
Taking out of unservicable self starter for 20-30 KVA DG Set & Supply & fixing new self starter as per original make of unserviceable one incl testing complete all as directed & specified by engr in charge.
Taking out unsv power contactor heavy duty 3 ph 400 amp AC and supply & fix power contactor of same make & rating complete as directed by engr in charge. Make- Siemens 3TF56
Taking out unsv power contactor heavy duty 3 ph 125 amp AC and supply & fix power contactor of same make & rating incl auxillary relay to operate the contactor complete as directed by engr in charge. Make - TC1D80004 & TA1DN11 of DNS
Taking out of unservicable self starter 12 volt and connected unserviceable portion of electric wiring and carring out repairs and overhauling of the self starter for 25 KVA to 75 KVA engine and replacement of armature, carbon brush, bearing, bendix penion,solenoid switch, bearing, tapping of field coil refixing of all component and fixed in existing postion including testing complete all as directed.
Dismantling of FIP, injector nozzles includings connected accessories from 25/82.5/125 / 200 /320 KVA Cumins/Kirloskar DG sets and M/L for carrying out overhauling, calibration and refixing complete and all as directed.( Note-During repair/calibration if any Injector nozzle,plunzer ,Delivery valve is found unserviceable the same will be measured seperately , however all the rest items required for making the FIP serviceable shall deem to be included in the cost quoted for overhauling of FIP.
Supply only following original spares parts of the engine required for replacement of the similar unserviceable spares and overhauling & all as directed and as specified. (a) Injector Nozzle (F602963000)
(b) Plunger (F602961000)
(c) Delivery Valve (F602962000)
Dismantling existing defective voltage stabilizer servo controlled of capacity 100 KVA (Make : Blue line) suitable for AC supply, 415 Volt, 50 C/s, 3 phase, ( input 340 volt to 440 Volt) and reassembling the same after carrying out the following repair works including painting with two coats of synthetic enamel paint of approved colour after preparation of surface all as specified and as directed including repairs and repalcement of following :- Drawing out of transformer oil from tank and storing in proper container carefully an refilling after repair works. Replacement of solid state auto controlled circuit assembly :- 1 Set Overhauling of synchronous motor :- 01 No Replacement of suction switch :- 01 No. (Make : L&T/GE POWER CONTROL or Equivalent) Replacement of burnt switch :- 01 No (Make : L&T/GE POWER CONTROL or Equivalent) Replacement of Voltmeter : 500 Volt, Square type 96mm x 96mm size :- 01 No. Make : SMR-96 of AE/HAVELLS /L&T) Repalacement of porcelain terminal bush including stud nut washer etc :- 04 sets Replacement of carbon bush for dimmer ball/variable auto transformer :- 09 Nos Replacement of top gasket :- 01 No Repairing,Heating, varnishing of transformer (Voltage transformer) coils including replacement of connection copper cable lug etc : - 03 Nos. (Note : Refilling Fresh transformer oil required for topping up shall be measured and paid separately).
Supply and filling of fresh (new) transformer oil topping up the required level in the stabilizer at di-electric strength not less than 45 KV at 3mm gap conforming to IS complete all as specified and as directed.
Dehydration and Filteration of transformer oil of voltage stabilizers, oil immersed starter at various pump houses to achieve die electric strength of 45 KV for 2 min at 3 mm gap as per relevant IS with portable filtration plant, testing of the oil for die electric strength before filtration and after filtration shall be conducted and all as directed as by Engineer-in-Charge.
M&L for cleaning of overhead tanks (inside) by scraping with the help of shovels, hard brushes and physical cleaning of tanks (Reservoir) by de-scaling / brooming silt and sludge and other deposits from inner side (bottom of dome), collecting and taking them out with help of manual labour and depositing at a distance not exceeding 50m and making the tank clean and washing properly with bleaching powder mixed with water (1:10) and applying two coats of quick drying lime wash on inner side, top and bottom surfaces including writing date of cleaning with white paint on black painted surface at two places and painting to the inner steel ladder of tank with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as directed and specified for the following capacity of tanks:- Note :- (a). Work is to be executed at 18 to 21m height. (b) All necessary T & P, labours and materials will be arranged by the contractor. (c) The above process of cleaning the tanks shall have to be completed by the contractor in max of two days (d) The quoted rates shall deemed to include for use of scaffolding, ladders,, etc as required for the entire completion of work. (e) Protective measures and insurance of labors working at height of 18-21m shall be the sole responsibility of the contractor and rates quoted shall be deemed to include for the same. (f) The quoted rates are deemed to inclusive of writing " TANK CLEANED ON ______" (of 75mm height & 10mm width) with synthetic enamel paint at two places on each tank. (g) Gap between consequtive cleaning of tank shall be minimuum three months. (h) 50% Number of tank cleaning should be completed within three months from the date of commencement of work. (a) RCC OH tank capacity of 100000 gallon.
(b) RCC OH tank capacity of 150000 Gallon.
(c) RCC OH tank capacity 50000 Gallon.
(d) RCC OH tank capacity 25000 Gallon.
(e) RCC OH tank capacity 10000 Gallon.
Supply and fix in replacement roller assembly suitable for chlorine dosing pump (packet of 04) complete all as specified and as directed.
Supply and fix in replacement injection check valve suitable for chlorine dosing pump (packet of 05) complete all as specified and as directed.
Supply and fix in replacement suction line strainer 3/8" suitable for chlorine dosing pump complete all as specified and as directed.
Supply and fix in replacement pump tube suitable for chlorine dosing pump (packet of 05) complete all as specified and as directed.
Supply and fix in replacement suction / discharge tubing 3/8" suitable for chlorine dosing pump complete all as specified and as directed.
Supply and fix in replacement check valve duckbill only suitable for chlorine dosing pump (packet of 05) complete all as specified and as directed.
Supply and fix in replacement connecting nut 3/8" with adopter suitable for chlorine dosing pump (packet of 05) complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement of granular chlorine dosing pump high pressure single head gear motorised adjustable type with non metallic liquid end including tubing, connecting nut, injection check valve and ferrule, section with all accessories complete all as specified and as directed.
Supply, laying testing and commissioning Flat submersible cable PVC insulated sheathed (Heavy duty) 1100 Volt grade with copper conductor of size 3 core 10 sqmm, complete all as specified and as directed.
Supply, laying testing and commissioning Flat submersible cable PVC insulated sheathed (Heavy duty) 1100 Volt grade with copper conductor of size 3 core 16 sqmm, complete all as specified and as directed.
M&L for earthing with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level connected to galvanized earth lead strip 25x4mm (earthing lead from earth electrode to test point uopt 7.5m ) by means of bolts, nut, checknuts and washers of galvanized iron or steel all as shown in electrical plate No 5 of MES Schedule Pt-I 1991, GI earth lead strip of size 25mmx4mm protected by GI pipe 40mm dia light grade and connected to earth test point including excavation & earth work in any type of soil, disposal of soil, providing charcoal dust and common salt upto 15cm above top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20 mm dia GI light grade including testing on completion complete.
Dehydration and Filteration of transformer oil of voltage stabilizers, oil immersed starter at various pump houses to achieve die electric strength of 45 KV for 2 min at 3 mm gap as per relevant IS with portable filtration plant, testing of the oil for die electric strength before filtration and after filtration shall be conducted and all as directed as by Engineer-in-Charge.
M/S East India Traders
BHANU GAJMER
PABITRA CONSTRUCTION
R.MANJIT& CO
L. B. SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .