Executive Engineer,PMU,Kottarakkara
Office of the Executive Engineer ,Vydyuthi Bhavanam, Kottarakkara
Interlinking Puthttu TMR to Bhagyakunnu by drawing 11KV ABC (CW-4669-202526-30) under Electrical Section, Anchal (West) under Electrical Division Punalur
2026_KSEB_843329_1
E-TENDER/2025-26/4153/77E dated 02-03-2026
Open Tender
Electrical Works
120 days
Electrical Section, Anchal (West)
Refer Tender Documents
9 documents required · 9 mandatory
₹5,900
₹29,500
11 May 2026
6 Mar 2026
21 Apr 2026
6 Mar 2026
16 Apr 2026
6 Mar 2026
6 Mar 2026 - 16 Apr 2026
Providing one Coil Earth using No 8 GI earth wire (50mm dia,115 turns), including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/ structure &back filling
Providing one Earth using earth pipeof size 38.1mm dia2.5m length including digging separate pit at a minimum distance of 1.5 m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil and backfilling
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11KV DP incl. conveyance of materials.
Transporting poles by hired vehicle to a distance up to 5km and carrying up to 4 poles excluding loading & unloading
Transporting LT ABC by hired vehicle to a distance up to 5km and carrying up to 2 drum including loading & unloading using crane
Fitting and erecting one HT DP using PSC pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing sufficient length of GI earthing leads through all cross arms to ground for earthing (excluding provision of earthing)
Erection of suspension clamp/dead end clamp for 11 kV ABC of any size
Fitting one Additional 75x40mm, 1.8m channel cross arm in existing single pole incl. conveyance of materials
Erection of Anchor clamp for 11 kV ABC of any size
Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transport by vehicle).
Fitting and erecting one HT A type pole in position incl. fitting cross arm,digging & back filling pit in ordinary soil(as per standards) , drawing sufficient length of GI earthing leads from F clamp through V cross arm to ground for earthing (excluding provision of earthing)
Fitting and erecting one HT PSC type pole in position incl. fitting cross arm, digging & back filling pit in ordinary soil(as per standards) , drawing sufficient length of GI earthing leads from F clamp through V cross arm to ground for earthing (excluding provision of earthing),drawing earth leads
Labour charges for loading HT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Fitting and providing one HT stay for 11KV pole incl. digging and back filling pit in ordinary soil
Providing Cable Tie
Fitting one set AB switch on existing DP giving connection and drawing sufficient length of GI earthing leads to the grounf for earthing excluding provision for earthing
Drilling hole of various sizes on existing Channel/Cross arm
Additional rate for excavation of Pit for A type pole in hard Laterite
Fitting and providing one HT Fly stay for 11KV Pole using HT PSC pole incl. digging and back filling pit in ordinary soil drawing sufficient length of GI earth leads to the ground for earthing (excluding provision for earthing)
Fitting and providing one strut using HT PSC pole incl. digging and back filling pit in ordinary soil
Dismantling and lowering down the Single phase WP service connection with guy wire from the OH line incl. reconnecting the same after completing the line work
Redoing single phase WP service connection complete including lowering down the guy wire portion ,repairing or changing WP wire ,GI wire,Fuseunit etc,changing energymeter cutout,neutral link etc if necessary and reconnecting the same including conveyance of material to site from section office at various location
Providing Strut using LT PSC pole including digging and backfilling pit in ordinary soil
Dismantling (without damage) one km LT additional conductor by dismantling cross arms,insulators and stacking the conductors in rolls properly
Dismantling (without damage) one km LT Sph 2 wire OH line,cross arms,insulators and stacking the conductors in rolls properly
Dismantling (without damage) one km LT 3ph 4 wire OH line,cross arms,insulators and stacking the conductors in rolls properly
Additional rate for refitting/redoing one Shackle set and reshackling one span while renewing any type of pole
Erecting one LT PSC pole in position including digging & backfilling pit in ordinary soil
Provding WP support with PSC pole including digging & backfilling pit in ordinary soil excluding transportation of poles
Labour charges for loading LT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Fitting one MVT on existing cross arm including 2 nos end termination (for one phase) of any rating for 11 kV AB Cable
Additional rate for excavation of one pit for coil earthing in laterite
Dismantling one ordinary street light /CFL/LED fitting from the existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires
Dismantling ( without damage) one LT PSC/RCC pole after disconnecting stays, strut, etc. and stacking the same
Dismantling one damaged LT PSC/RCC pole after disconnecting stays,strut etc and stacking the same
Dismantling one damaged LT PSC/RCC Strut pole including removal of clamps and stacking the same
Dismantling one section fuse from structure and bringing back to section store
Dismantling one section fuse from the distribution box and bringing back to section store
Pole numbering using printed Aluminium sheets of 22 SWG having size 20x12 cm or Painting the surface of line supports where numbers are to be inscribed .Pole numbers shall be painted in circular/rectangular background using approved quality anti algal yellow paint in two coat after scrapping and cleaning the surface at a height of 2.5 metre above ground level.The number and letters should be in black synthetic enamel.The size of the number should be atleast 2 cm in height x 1.5 cm in width incl cost of paint
Providing concrete muffing (0.45x0.45x1.5m) ( 0.5m above GL and 1m below GL).Excavation 0.45x0.45x1m concrete (1:3:6 20mm) 0.45x0.45x1.5m.Plastering (1:3) 12mm 0.45mx0.45mx 5 sides
Stringing of 11 kV aerial bunched cable of size 3 x 120 +1 x 95 sqmm with bare/insulated messenger through existing poles
Stringing ,shackling,fitting cross arms,insulators and binding,giving jumper connection etc using ACSR Rabbit for phase and ACSR weasel for Neutral & Street main for one km LT 3 ph 5 wire line including cutting and removing tree branches whereever necessary and conveyance of all materials (except poles) from stacking place
Stringing ,shackling,fitting cross arms,insulators and binding,giving jumper connection etc using ACSR Rabbit for phase & Neutral and ACSR weasel for Street main for one km LT single phase 3 wire line including cutting and removing tree branches whereever necessary and conveyance of all materials (except poles) from stacking place
Stringing ,shackling,fitting cross arms,insulators and binding,giving jumper connection etc using ACSR Rabbit for phase & Neutral for one km LT single phase 2 wire line including cutting and removing tree branches whereever necessary and conveyance of all materials (except poles) from stacking place
Additional rate for excavation of one Pit for HT pole/ HT stay in hard laterite
Transferring LT 3 ph 4/5 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators refitting the same on the new pole,binding ete complete
Transferring LT 3 ph 2/3 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators refitting the same on the new pole,binding ete complete
Fitting one no section fuse on LT line with dropping cables , crimping sockets, connecting with Bolt&Nut etc
Additional rate for excavation of one Pit for HT pole/ HT stay in laterite
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1425265.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
Tenderdocuments.pdf
Tender Documents • 0.95 MB
BOQ_1425265.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid