Tender Value
₹25.7 L
EMD Value
₹25,705
Closing Date
31 Aug 2026, 5:00 pmClosed
Superintending Engineer, GIDC, Ahmedabad
Do the necessary modification work of installed Solar tree system at Pump house- 1,GIDC,Sanand-2
335461
05/2026-27
Open
Electrical
Works
Ahmedabad
4 documents required · 4 mandatory
₹1,770
Executive Engineer,GIDC Ahmedabad
₹25,705
14 Aug 2026
14 Aug 2026
14 Aug 2026
31 Aug 2026
14 Aug 2026
Total Amount in Rs
Total Amount in Rs
1 S.I.T.C of Poly Crystline/Mono Crystline PV Module (ALMM Per 390.00 30.30
approved) with 72 Cells - 150 Cells or More , Frame Material : Watt
Anodized Aluminum alloy Frame With Twin Wall Profile, Front
Cover : High Transmission Low-Iron Tempered Glass (AR Coated),
High efficency and positive power tolerance Pmax: 0/+5, Module
Efficiency should be approx. 18%-21%, Normal operating
temperature 45'C, Junction Box with Waterproof IP67 & MC4
Compatible and Enclosed with Bypass diodes 100%
Electroluminescence test to ensure error free Modules, Thw temp.
co-efficient of the PV module shall equal or better than -
0.45%/degree C. Solar PV modules of minimum fill factor 75% to
be used. Unit Production:- 4 to 5 Unit /kw /day (Actual)(1Year
Avg) With 10 year Product warranty and 25 year Linear Power
Warranty.(B) Moudule o/p Range: 365 - 390 watt, Maximum
Power Voltage Vmpp: 39 - 40 V, Maximum Power Current Impp: 9 -
2 S.I.T.C of Solar Inverter Gried Tied: MPPT Range: 80-1000 V, Max Per 100000.00 9.09
efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Watt
Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%,
Operating Tempreture Range: -25~60°C, Anti-islanding
Protection: Integrated, Input Reverse Polarity Protection
Integrated, Insulation Resistor Detection Integrated, Residual
Current Monitoring Unit Integrated, Output Over Current
Protection Integrated, Output Short Circuit Protection Integrated,
Output Over Voltage Protection Integrated, Protection Degree:
IP65, User Interface LCD & APP,Datalogger & Communication:
GPRS / Wi-Fi (Optional)(C) Solar Inverter: 6 kW to 15 kW: Max.
input Current: 22 A, Max DC i/p Power: 7800-19500 W & Nominal
o/p Power: 6000-16500 W, Nomimal O/p Voltage: 400 V 3-Phase,
Nominal O/p Current: 10-24A,
3 SITC of XLPO/XLPE Insulated, Tinned Copper, Single Core Solar DC Mtr 300.00 95.95
Cable of size 6 sq.mm
4 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable Mtr 1500.00 540.35
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following
size of cables 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
5 Providing & laying approved make Double walled corrugated Mtr 200.00 62.62
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground / road
surface for enclosing cable 50 mm outer dia
6 Providing in standard length ISI mark high density Polyethylene RMT 800.00 631.25
H.D.P.E. Pipes suitable for potable
water as per IS specification no. 4984/1995 including all local
and central taxes, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to the
dept. stores etc. comp.and lowering,laying and jointingHDPE pipe
and specials 6.0 Kg/cm2 160 mm dia
7 Providing and, fixing heavy duty flange type brass double Ea 50.00 140.39
compression type cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc
for following size of cables. 3 & 1/2 core 120 Sq. mm
8 SITC of Solder less crimping type Aluminium lugs conforming to IS Ea 80.00 45.45
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
9 Making trench in soft soil of suitable width of 90 cm deep for Mtr 1000.00 55.55
laying cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
10 SITC of Fibre sheet Shed with necessary mounting arrangement for Sq.ft 300.00 353.50
the protection of Solar inverter as directed by engineer in charge
11 S.I.T.C of Distribution board from AC Side, ACDB 3-Phase - 11 kW - Ea 5.00 8304.22
20 kW: AC1 DUTY CONTRACTOR‐40A 4P,
100A MCCB 4P(Cat III), 3 PHASE SPD, VOLTAGE MONITORING
ELR WITH CBCT, PHASE INDICATING LAMP, POWER CABLE &
OTHER ACCESSORIES, All switchgears and connection are
enclosed with IP66 Enclosure and operate the MCB position.
12 S.I.T.C of Distributiob System DC Side, DCDB - 20 kW - 25 kW Ea 5.00 14723.78
(5in:5out) : Input Mcb - 1000 V, 16 Amp,
1000 V DC SPD TYPE 2, TERMINAL/END,PLATE/END CLAMP:
4SQMM (KUT6) FOR OUTPUT, DC CABLE With suitable size of
interconnection.
13 Supplying & Errecting MC4 Connector Male - Female Set for Solar Ea 100.00 52.52
DC Cable which is installed in Solar PV-module/Inverter/DCDB
Total of work of SITC of items from sr no.1 to 13
14 Buyback of Old Solar Inverter of 100 KW. Ea 1.00 75750.00
Note:- The Bidder has to note that buyback amount of
Rs.75750 fixed by the corporation and the same will be
deducted from RA bill of the Bidder and also note that
above/below quoted rate shall not applicable in this item
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
DTP Sr no.6.pdf
form B-1 23_1.pdf
form B-1 23_2.pdf
form B-1 23_3.pdf
form B-1 23-4.pdf
Schedule B Solar Tree Sanand.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .