Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND REASONABLE | |
| 2 | L2₹31.4 L+₹74,579.76 (2.44%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 3 | L3₹31.9 L+₹1.2 L (4.08%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 4 | L4₹33.2 L+₹2.6 L (8.50%)Rejected-Finance DUNIYAGANJ DUNIYAGANJ PHULPUR PHULPUR ALLAHABAD UTTAR PRADESH 212402 | PRAYAGRAJ | UTTAR PRADESH | 212402 | L4 | Rejected-Finance AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 5 | L5₹33.6 L+₹2.9 L (9.62%)Rejected-Finance | L5 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
Tender Value
₹36.9 L
EMD Value
₹73,880
Closing Date
1 Apr 2025, 6:00 pmClosed
GARRISON ENGINEER
GE RAMGARH CANTT
SPECIAL REPAIR TO OTM ACCN BLDG NO T-25 AND T-42 AT PRC RAMGARH CANTT
2025_MES_699989_1
8300/3306/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹73,880
Yes
30 May 2025
3 Mar 2025
7 Apr 2025
3 Mar 2025
1 Apr 2025
24 Mar 2025
Amount
Dismantling of AC sheet (corrugated,semicorrugated, etc.) including AC ridges as in roof coverings complete all as specified & directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
S&F roof trusses (framed), trussed, purlins, crane guntries, rail, fastening ,heavy bracket ,rafter,framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.,including welding counter shunk for holes and necessary gusset plates, wind tie etc., and similar work conforming to Fe-410-W(Gde E-250) quality-A complete all as specified & directed.
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off from site upto 500mtr complete all as specified and directed.
M&L for Brick work using old size sub class "B" bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc & removing the debris from the premises upto 500 m from the MOD land complete all as specified and directed
M&L for rendering 15 mm thick on other than fair face brick masonry/concrete surface etc., in cement mortar 1:4, surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick cement plastering on fair face of brick masonry/concrete surface etc in cement mortar (1:6) surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying 3mm thick wall care putty(J K /BIRLA) in two layers to make entire surface free from undulations complete all as specified and directed.
M&L for prepatation of newly plastered surfaces of wall and applying two coats of oil bound distemper of any shade over a coat of chalk whitening primer on walls surfaces complete all as specified and directed.
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces and apply two coats of distemper oil emulsion (OBD) over a coat of chalk whitening primer on wall (not less than 1.5 mm thick )complete all as specified and directed.
M&L for prepatation of newly plastered surface of wall and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one two coat of cement base paint on wall surface complete all as specified and directed.
Dismantling wall and ceiling boarding, any description, fixed in any position with nails/screws complete all as specified and directed.
S & F in repair for providing powder coated aluminium snap grid frame work for false ceiling system with size 605 mm x 605 mm, consisting of main runner of size 36.5 mm x 25 mm x 1.4 mm (weight not less than @ 0.24 Kg/Rm) and cross Tee of size 23.5 mm x 36.4 mm x 1.4 mm (weight not less than @ 0.191 Kg/Rm). The snap grid shall be supported at end all along the wall with aluminium powder coated angle of size 40 mm X 25 mm X 2 mm (weight not less than @ 0.36 Kg/Rm).The snap grid shall be fixed to ceiling supporting hangers consisting of 6 mm dia. G.I wire , J-bolts ,nuts and washers as per manufacturer's instructions or adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and complete all as specified and directed by Engr-in-Charge.
M & L for 6.0 mm thick Non asbestos fibre cement building boards fixed in ceiling flat or sloping fixed or laid/ inserted to timber/GI/Aluminium frame work with screws complete all as specified and directed by Engr-in-Charge.
Re-fixing only in repair of existing old Non asbestos fibre cement building board, fixed or laid/inserted to timber /GI/Aluminium frame (existing old frame but necessary joint etc.) work with screw complete all as specified.
M&L for preparing the new/untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for prepartion of old painted of steel surface of any description , not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint on old steel painted surface complete all as specified & directed.
M&L for IInd class hardwood scantling framed & fixed clean swan of any size/ thickness for truss or in any work in any situation complete all as specified and directed by Engineer-in-Charge
M & L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for prepartion of old painted of wooden surface of any description , not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint (ordinary tint) any colour on old wooden painted surface complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the all rubbish off from the premises complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18mm -20 mm thick of size not less than 575 mm X 575 mm, over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing with Beewax polish over & including 20 mm thick screed bed in CM (1:4) complete all as specifed & directed.
M&L for machine cut kota stone slab in skirtings,riser of steps ,dado & pillar 16 mm to 18 mm thick,laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing with Beewax polish over and including 10 mm thick backing coat in CM (1:4) etc complete all as specifed & directed.
M&L for grinding, rubbing and polishing with Beewax polish (minimum in two layers) of existing kota stone slab flooring to achive mirrror finish complete all as specified and directed.
M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc., over & including 15mm thick screed bed in cement mortar 1:6, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
M & L glazed ceramic coloured tiles of size 375 mm x 250 mm x7mm/450 mm x 300 mm x7 mm thick ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles, over & including 10 mm thick rendering in cement plaster in cement mortar 1:4 complete all as specified and directed.
Demolition of Plain cement concrete(un-reinforced ) in ground floors, terrazo tiles floor & paving of any description and removal of rubbish off from site upto 500mtr complete all as directed by Engineer-in-Charge.
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
M&L for 40 mm thick plain cement concrete 1:2:4,type B-1(using 20 mm graded crushed stone aggregate) as in floor /hardstanding etc & surface finished even and smooth without using extra cement including dividing strips inserted in position, conform to design complete all as specified & directed. Note :Glass dividing strip shall be measured & paid seperately under respective item of BOQ.
Supply only 38 mm wide glass dividing strips,3.0 mm thick inserted in position,conform to design complete all as specified & directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) including builders hardware etc & making good disturbed surface of wall with CM 1:3 complete all as specified and directed
Taking down chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4.0 Sqm each (without taking off shutters from the frames) including builders hardware etc & making good disturbed surface of wall with CM 1:3 complete all as specified and directed
S&F for 1.25 mm thick pressed steel door frames of size 165mm x 60 mm for single or double doors or window with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in filling in pressed steel door complete all as specified and directed. Note: (i) The quoted unit rate under this item shall deemed to be included necessary fixing lugs hinges lock strike plate etc complete all as specified and directed. (ii) One coat of bitumen paint of inner side of pressed steel door frame before filling of PCC).
S & F 35 mm thick(factory made), IInd class hard wood plain framed panelled door shutter (two panel) with lock rail and panel of 12 mm BWP commercial ply on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed .
S & F 35 mm thick, factory made, IInd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. (divided into squares with plain, chamfered or rounded, mitred and rebated sash bars any number size of members), beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a); kiln seasoned & chemically pressure treated etc complete all as specified and directed . (Note:- (i)Glass / wire cloth shall be measured & paid separately.(ii) Sample of shutter in sample room of GE office.)
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.0 Sq m each and refixing in the same opening after necessary easing, adjustment etc., complete all as specified and directed by Engineer-in-Charge .
S&F steel window with side hung shutter with cooller arrangement including box type hinges with steel handles and steel peg stay complete with glazing bars, dovetailed or welded with four Nos mild steel flat iron 25 mm X 3mm ,200 mm length (appx) & two Nos mild steel tower bolt 150 mm long and one peg stay on each leaf complete all as specified and directed
S&F steel window with side hung shutters including box type hinges with steel handles and steel peg stay complete without glazing bars, dovetailed or welded with four Nos mild steel flat iron 25 mm X 3mm ,200 mm length (appx)& two Nos mild steel tower bolt 150 mm long and one peg stay on each leaf complete all as specified and directed
S & F for steel windows or ventilators, fixed type, with glazing bars complete including prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F Stailness steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks etc complete all as specified and directed.
M & L for 3mm thick plain sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 Sqm in each pane for window and ventilator,complete all as specified and as directed by Engr-in-Charge .
Hacking out old broken glass(any thickness, size, quality or description) from wooden frames/steel frames, glazed with oil putty or fixed with beads complete all as specified and directed
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165 & for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc.complete all as specified and as directed.
M&L for 9-10mm thick Vitrified Ceramic tiles in dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floors etc., over & including 15mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile colour complete all as specified and directed.
M&L for 9-10mm thick dark shade Vitrified Ceramic tiles, polished area of each tiles not exceeding 0.36 sqm, laid in vertical surface such as skirting/dado etc, over & including 10mm thick rendering in CM 1:4, set and jointed in neat cement slurry and polished in coloured cement to match complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed.
S & F aluminium sliding door bolts 300 mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections and fixed, complete all as specified and directed.
S&F in repair Stailness steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stailness steel wire staples in repair complete all as specified and directed.
S & F in repair 100mm size butt hinges medium weight cold rolled mild steel and fixed in repairs complete all as specified and directed .
S&F mild steel 200 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
S & F in repair 19mm/20 mm dia curtains rod of chromium plated mild steel tubing with fixing for fancy type brackets,stops, rollers etc.,complete all as specified and as directed by Engineer-in-Charge. Note: Running length of curtain rod shall be measured & paid only.
S&F in repairs mild steel Peg set fancy type of six,hat and coat hooks, solid body, not less than 300 mm long complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in levelling course, coping, window cill etc finished even and smooth without using extra cement complete all as specified & directed.
M&L for 60 mm thick factory made glazed machine pressed chamfered edge pre-cast concrete coloured (yellow & red) interlocking paver block of approved shade, design & pattern , laid as in footpath, light traffic parking etc, made by table vibratory method using PU mould of any shape and size conforming to IS-15658-2006 of M-35 grade laid over & including 50mm thick compacted bed over fine sand, compacting and proper embedding/ laying by vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L for 100 mm thick plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in hardstanding/flooring etc including necessary formwork, if required complete all as specified and directed.
Taking down shutters of any description not exceeding 1.00 Sqm and refixing in the same/other opening after necessary easing, adjustment etc., complete all as specified and directed by Engineer-in-Charge .
S &F 150mm long aluminium handles cast type, anodised complete all as specified and as directed.
Taking down carefully unserveciable/damaged copper/aluminium surface (batten/conduit or casing-N-caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
M&L for point wiring for following (one light/fan/exhaust fan point/ bell /buzzer) point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
(a) One light point controlled by one one way switch
(b) One fan/exhaust fan point controlled by one one way switch cutting except on ceiling for fan point only,on ceiling PVC conduit will be used
(c) One 3/5 pin socket outlet 5 amp on same board with other switches
(d) One 3/5 pin,5 amp socket outlet on independent board
M & L Sub main wiring with two runs of single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia/appropriate dia with accessories & fittings complete and making good disturbed surface wall including taking down existing sub main wiring complete all as specified and as directed. Note : - Two runs of 6.0 Sqmm cable and one run of earth wire 6.0 sqmm & conduit shall be measured as one unit length and extra length of cable required for connection to MCBs shall be deemed to be include in unit rate quoted by bidder.
S&F switch piano flush type polycarbonate single pole one way 6 Amps complete all as specified and directed .
S&F socket outlet polycarbonate 2 in 1, 3 pin 6 Amps flush type complete all as specified and directed
S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, ISI marked complete all as specified and as directed. .
S&F Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed.
S&F in repair LED bulb of capacity 10 watts lumen out put (1200 lm) length 102 mm dia, 56 mm, base cap B22, (ISI marked) complete with all accessories (ISI marked) all as specified & directed by Engr-in-Charge. .
S &F Inverter LED bulb of capacity 12 watts lumen out put (1200 lm) length 140 mm width 70mm base cap B22, 3 star, (ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engineer-in-Charge.
M&L for point wiring for one light/fan point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable for 16 amp 3/5 pin socket power point conforming to IS:694,1100V grade AC, single core having multi stranded copper conductor of size 2.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC surface conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in surface wiring system & 2.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated sheet top cover make sheet for housing/ fixing switches etc.,including cutting holes for switches,sockets,regulators etc as per requirement including flugs required complete all as specified and directed.Note: Proper colour coding to be adopted.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed
S & F for LED batten fitting 1 x 20watt , 220 V, surface mounting including connecting up with two core flexible copper conductor cable of suitable size with flexible pipe from ceiling rose to fitting of any size complete all as specified and as directed by Engineer-in-Charge.
S & F for LED batten fitting 2 feet x 10 W, mirror type , 220 V, ACsurface mounting including connecting up with two core flexible copper conductor cable of suitable size with flexible pipe from ceiling rose to fitting of any size complete all as specified and as directed by Engineer-in-Charge.
S & F in repair sheet metal enclosures for DBs when MCBs to be used in double door Tripple Pole and Neutral (TPN) double door 415 volts, 6 way, with including suitable amp rated bus bar and neutral link (ISI marked) and provn of MCCBs, in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S&F in repair 415 V 10 KA 'C' curve miniature circuit breaker (MCB) of TPN/FP ( tripple poles and neutral/four pole) and current carrying capacity 40 to 100 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
S&F in repair of double door SPN DBs sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts suitable amps rated busbar 8 way complete all as specified and directed by Engr-in-charge.
M&L for MCB single pole, 6 to 32 Amp 240 Volt 'C' curve 10 KA,IP 20 transparent lebel holder fully insulated safety hutters suitable for cable upto 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.
S&F in repair 240V, 10KA 'C' curve miniature circuit breaker (MCB) of double poles (DP) and current carrying capacity 40 Amp with breaking capacity 10 KA, in the MCB DB with connection testing and commissioning complete all as specified and as directed.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh, charcoal & salt, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally & angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including making good disturbed surface of wall ,floors etc.including taking down/dismantling of existing earthing complete all as directed. Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc.
Supply, laying ,jointing ,testing and commissining LT cable, XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq.mm. 3.5 core including taking down of existing cable complete all as specified & directed. Note:- 1. Excavation & earthwork shall be measured & paid under respective item. (2) All Necessary T & P required shall be arranged by the Contractor.
S & F in repair 40mm dia GI pipe light grade for protection of LT UG cables for crossing roads/on wall/poles etc including GI clamps nut bolts and washer etc complete if any all as directed and specified
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width or not exceeding 10 Sqm on plan and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes, foundations, laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L sand filling in cable trenches for cable protection for clean dry sand unwashed including gently punning in a layer of 15 cm and 8 cm (total 23 cm) inthickness all across the laid portion of LT cable in trenches complete all as specified and directed. (Note:-Punned thickness shall only be considered for payment)
Supplying & Laying factory made un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, complete all as specified and directed by the Engineer-in-Charge.
S&F new generation energy saving and environmental friendly long life LED bldg security light of capacity 35W 230volt AC outdoor type including connecting up with three core flexible copper conductor cable of suitable size with flexible pipe of complete all as specified and directed.
S&F in repair of bracket made of GI pipe light grade 1.5 Mtr long of size 40 mm bore, bend to shape as per site requirement fixed to pole/wall with flat iron clamp size 50mm x 6 mm -02 Nos with suitable bolts, Nuts, washers etc including two coats of synthetic enamel aluminium paint over a coat of red oxide primer on exposed surface of mild steel surface complete all as specified and directed.
S &F in repair mild steel hooks fabricated/made out of flat iron 50 mm x 6mm including nut, bolts (6-8 mm dia & 40 to 50 mm long with spring washer) duly painted complete all as specified & directed by Engineer-in-charge.
S&F in repair down rod fabricated out of 15mm dia heavy grade MS conduit not less than length of 1250mm mild steel hanging clamps of suitable/appropriate size & shape for down rod of with rubber reel, nut ,bolts with washer and including spliting pin suitable for 1200 mm/1400 mm sweep of ceiling fans duly painted with two coat of synthetic enamel White paint complete all as specified and directed.
M&L for Boring of hole under road, pavement, hard standing by trenchless using manual technique with required tools complete all as specified and directed by Engineer-in-Charge. Note : (i)Pipes shall be laid minimum 2.00 mtr below/under existing road surfaces/ apron /floors etc. (ii) T&P requird for road boring to be provided by the contractor at site own cost and no any claim enterained on this accont on later stage.
Supply and laying for HDPE pipe 40mm dia of pressure rating 6 Kgf/sq.cm fixed with all necessary fittings for cable protection in walls, ceiling, floors, road etc complete all as specified and directed by Engineer-in-Charge.
M/S Balaji Construction & Company (BID ID -3274163)
M/s friend enterprises (BID ID -3274819)
SHUBHAM CONSTRUCTION COMPANY (BID ID -3273241)
Modernage Constructions Pvt. Ltd. (BID ID -3270971)
M/S Parmar Construction (BID ID -3274933)
M/S SHAMBHU SHARAN SINGH (BID ID -3273892)
simplex infra project (BID ID -3273288)
ganpati enterprises (BID ID -3274677)
upadhyay engineers and consultant (BID ID -3274646)
M/S CHAUHAN CONSTRUCTION (BID ID -3273159)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .