Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 0 TANDA VILLAGE KHAIRPUR TANDA AYODHYA VILLAGE TOWN POST MAKHDOOM NAGAR CITY AMBEDKAR NAGAR AMBEDAKAR NAGAR UTTAR PRADESH 224190 INDIA | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.0 L+₹2.6 L (6.21%)Rejected-Finance HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹45.4 L+₹4.0 L (9.67%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹46.2 L+₹4.8 L (11.5%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹48.0 L+₹6.6 L (16.0%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L5 | Rejected-Finance Being L5 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
5 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL UTKARSH SHARMA
OPP BIRLA FACTORY GE (I) CG PORBANDAR
ADDITION/ALTERNATION AND IMPROVEMENT TO BUILDING No. P-12 AT DHQ-1 UNDER GE I CG PORBANDAR
2023_MES_627182_1
8937/E8
Open Tender
Civil Works
Item Rate
180 days
PORBANDAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹83,000
Yes
18 Dec 2023
7 Nov 2023
7 Dec 2023
7 Nov 2023
5 Dec 2023
22 Nov 2023
Amount
SCHEDULE 'A' B/R ITEMS
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc., complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar and in any position etc., complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 75mm thick cement concrete type C–1 (1:3:6) using 20mm graded stone aggregate as in plinth protection etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Porbandar stone masonary, well bonded, bedded and solidly hearted builtin Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Vitrified Light shade, Double charged ceremic tiles 9 mm thick (square/rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15mm thick with cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Vitrified Light shade, Double charged ceremic tiles 9 mm thick (square/rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of mortar 10 mm thick with cement mortar 1:4, complete all as specified and directed by Engineer-in-charge.
Material & Labour for non skid coloured designer ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in Cement Mortar (1:4), complete all as specified and directed by Engineer-in-charge.
Material & Labour for glazed coloured ceramic tiles in verticle surfaces 350x250x7 mm/450x 350x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer 10mm thick cement mortar 1:4 and pointed in white or coloured cement to match, complete all as specified and directed by Engineer-in-charge.
Material & Labour for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of 15mm thick with cement mortar 1:6 etc., complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster of any description and in any position, complete all as specified and directed by Engineer-in-charge.
Material & Labour for rendering 10mm thick on fair face of brick work or concrete surfaces in Cement Mortar 1:6 finished even and smooth wiithout using extra cement, complete all as specified and directed by Engineer-in-charge.
Material & Labour for rendering 15mm thick on fair face of brick work or concrete surfaces in Cement Mortar 1:4 finished even and smooth wiithout using extra cement, complete all as specified and directed by Engineer-in-charge.
Material & Labour for rendering on ceiling 10mm thick in Cement Mortar 1:3 on brick work or concrete surfaces finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-charge.
Material & Labour for preparation of new plastered or unplastered surfaces and applying two coats of oil bound distemper on wall over a coat of alkali resistant primer over two coat of wall care putty (water proof), complete all as specified and directed by Engineer-in-charge.
Material & Labour for preparation of new plastered or unplastered surfaces and applying two coats of oil bound distemper on ceiling over a coat of alkali resistant primer, complete all as specified and directed by Engineer-in-charge.
Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturers instructions, complete all as specified and directed by Engineer-in-charge.
Complete removal of existing treatment and two coats of oil bound distemper on wall over a coat of alkali resistant primer over two coat of wall care putty (water proof) complete all as specified and directed by Engineer-in-charge. Note:- after painting cleaning of all floors, glass, Supply & Fixing furniture by own arrangement).
Complete removal of existing treatment and two coats of oil bound distemper on ceiling over a coat of alkali resistant primer, complete all as specified and directed by Engineer-in-charge. Note:- after painting cleaning of all floors, glass, Supply & Fixing furniture by own arrangement).
Supply only liquid water proofing compound, complete all as specified and directed by Engineer-in-charge.
Taking down chowkhat with shutters (without taking of shutters from the frames of any description not exceeding 1.5 Sqm in each panel, complete all as specified and directed by Engineer-in-charge.
Taking down chowkhat with shutters (without taking of shutters from the frames of any description exceeding 1.5 Sqm but not exceeding 4 Sqm in each panel, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 2nd class HW plain chowkhats and framed, rebated on the solid rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 35mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. as specified in SSR Part I, Section 8, clause 8.20 (a), complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 40mm thick Flush Shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match commercial type on both side, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing powder coated anodised aluminium window /door or ventilator frame with side / top hung respectively with glazed shutters comprising of chowkhat and shutter, section thickness 0.50mm thick and weight not less than 0.55 Kgs per RM including jointing cleats, complete to size as per site requirement, and as approved by Engineer-in-charge, complete all as specified and directed by Engineer-in-charge. Note:- Minimium thickness of powder coating 50 micron
Supply & Fixing powder coated anodised aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter)(45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories, complete all as specified and directed by Engineer-in-charge. Note: The unit rate excludes cost of glass and includes all other connected accessories) area n.exc. 2.00 sqm each fixed from ground floor to height of 2nd floors.
Supply & Fixing for 7mm thick Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size 75x75 mm for fixing and operation of handles and fixing approved anodised aluminium standard C section around the opening. fixed from ground floor to height of 2nd floors, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing Float glass 5.5mm thick plain provided to aluminium frame for door/window/partition with necessary aluminium powder coated snap beading and rubber gasket/packing, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 100mm long medium weight, cold rolled SS steel Butt hinges, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 150mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 150mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing 100mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for staineless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium/pvc sections, complete all as specified and directed by Engineer-in-charge.
Supply & FIxing 30mm thick factory made 100% solid WPC (Wood polymer composite) Solid Plain/Prelam/Enrouted Plain/Enrouted Painted flush Door Shutter of required size comprising of Virgin PVC resin of K Value 57-60 (Suspension Grade), Calcium carbonate and natural fibers (Wood Powders/rice husk/Wheat husk) and Non toxic additives made from Extrusion process WPC foam sheet single Extruded (Inner) with density not less than 650 Kg/cbm manufacture by an ISO 9001-2015 Certified Company, having good screw holding capacity (Screw withdrawl strength of 2000 N (face) & 1100 N (Edge), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread flame of Class A category with Property of being Termite/Borer Free, Water/Moisture Proof, Fire Retardant and fixing with Stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws for WC/Bathroom/Toilet/Kitchen/Balcony Doors, complete all as specified and directed by Engineer-in-charge.
Supply and Fixing factory made 100% Solid WPC (Wood Polymer Composite) - Door frame of size 75mmx50mm made from wood Polymer Composite (Single Extruded process) material comprising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium carbonate and Natural Fibers (Wood Powder/Rice Husk/Wheat Husk) and Non toxic additives fabricated with meter joints after applying PVC solvent cement & Screwed with full body threaded star headed screws having minimum frame density of 780 Kg /cbm manufacture by an ISO 9001-2015 certified Company, having good screw holding capacity (Screw withdrawal strength of (Min 990N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Draft Fasteners/Hold Fast of required dia and length for WC/Bathroom/Toilet and external uses, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing 7mm thick aluminium grills of make "Decogrill" model DG 104 surrounded by aluminum 'C' channel and size of opening 75x75 mm, fixed from ground floor to height of 2nd floors, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 3mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-charge.
Preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of pink primer and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing 300mm long MS ordinary rat tail rod pattern springs including roller, complete all as specified and directed by Engineer-in-charge.
Dismantling of boarding, any description fixed in any position with nails i.e. in cupboard shutters, partitions and similar position, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing 18/19 mm thick, prelaminated PVC moulded solid shelves and drawers boxes fitted under cooking platform and other platforms including 2 Nos telescopic channel, 1 No handles (50mm to 65mm), complete all as specified and directed by Engineer-in-charge. Make:- Nova pan / Century Ply / Archid Ply
Supply & Fixing continous piano hinges SS steel bright finish or galvanised of 30mm width, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing 100mm aluminium anodised Hasp and staple, safety type, complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing and connections, 15mm dia, complete all as specified and directed by Engineer-in-charge.
Supply and laying of CPVC pipes, of 20mm dia SDR -11 including plain CPVC SDR fittings for Hot/cold water for sizes (outer dia) mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all as per manufacturers recommendations, complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing and connections, 20mm dia, complete all as specified and directed by Engineer-in-charge.
Supply and laying of CPVC pipes, of 25mm dia SDR -11 including plain CPVC SDR fittings for Hot/cold water for sizes (outer dia) mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all as per manufacturers recommendations, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair 15mm bore pillar taps, cast copper alloy fancy type with captain heads chromium plated screw down high pressure with long screwed shanks and fly nuts screwed for iron pipe, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repairs Hand Shower (health faucet) 15mm bore with 1 meter long easy flexible tube in chrome finish and wall hok with NRV (Back Flow Preventer), complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair Vitreous china wash basin, white, size 600 x 360x 95 mm including waste pipe, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 38mm dia PVC (flexible) waste pipe, 800mm long for urinal, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair EWC one piece with integrated cistern with soft closing seat cover and twin flush fittings size 690 x 375 x 785, white in colour, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing for 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair 15mm bore Bib taps, with flange chromium plated cast copper alloy with capstan head, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair 15mm Angle Cock/stop valve, fancy type, brass chromium plated, screwed down, high pressure, with capstan head, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair Tubular towel rail CP Brass, 60cm long between flanges, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing Toilet Roll Holder with flap, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing Soap Dispenser holder, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair 7" over head shower with 225mm with flange, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair stainless steel grating doom, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed by Engineer-in-charge.
Supply & Fixing PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trench of bore 110mm (rates includes for making good disturbed surfaces), including taking down old unserviceable pipe, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trench of bore 75mm (rates includes for making good disturbed surfaces), including taking down old unserviceable pipe, complete all as specified and directed by Engineer-in-charge.
Supply & Fixing PVC (SWR) bends any radius of 75mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC (SWR) bends any radius of 110mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) vent cowl as specified of dia 75mm bore, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 12mm thick Gypsum Board seamless Ceiling as in curved, sunken or raised surface of any design as approved and finishing the surface fair by filling the joint with POP and inlcuding GI frame work for curved, sunken or raised for any design as approved as in ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9 mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm center to center with GI cleats and steel expansion fasteners with and including ceiling section (not exc 1.20 m length ) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.50 mm fixed to the intermidate channel at 457 mm center to center fixed with hanger of gi channel out og gi channel used as above upto 1200 mm length in roof slabs by means cleats, complete all as specified and directed by Engineer-in-Charge. Note: Flat area will be measured.
Material & Labour for 12mm thick Gypsum Board seamless Ceiling as in flat surface, finishing the surface fair by filling the joint with POP and inlcuding GI frame work as flat surface approved as in ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9mm thick having equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm center to center with GI cleats and steel expansion fasteners with and including ceiling section (not exc 1.20 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.50 mm fixed to the intermidate channel at 457 mm center to center fixed with hanger of gi channel out og gi channel used as above upto 1200 mm length in roof slabs by means cleats, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 12mm thick toughned glass as in door/partition with patch fittings with cover plate of SS-304 Grade, necessary accessories and fittings etc. including cutting holes in any size in floor and wall, complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC 1:2:4 Type B-1 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary forms works, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for formwork of soffits of suspended slabs such as roof slab, floor slabs, landigs, shelves and similar work, not exc 200mm thick rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth not exceeding 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or equivalent make in Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat, complete all as specified and directed by Engineer-in-Charge. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar).
Supply and fixing a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78, complete all as specified and directed by Engineer-in-Charge. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar)
Material & Labour for mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including prepartaion of surface throughly and cleaning complete where ever required with using Product: Sikadur®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture Sika Plasto creat plus or equivalent make in Fosroc / Thermax as per manufacturer's instructions as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. The gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement and directions of Engineer-in-charge.
Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product: Sika Rep® Microcrete-4 + adequate coarse aggregate, Yield: approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed by Engineer-in-Charge.
Material & Labour for application of one coat of Water based concrete curing compound with low viscosity wax emulsion using Sika Antisol E - WP of Sika or equivalent make in Fosroc / Thermax as approved by GE, as concrete curing membrane over the applied polymer mortar as temporary curing membrane as per the technical specifications and manufacturer's instructions complete all as specified and directed.
Material & Labour for CRS steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
-ditto- all as per item No. 91 above, but 6mm to 8mm dia. complete all as specified and directed by Engineer-in-Charge.
-ditto- all as per item No. 91 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 20mm thick cement plaster in cement mortar 1:4 mixed with 2% of water proofing compound as in roof treatment when concrete is green, complete all as specified and directed by Engineer-in-Charge.
Providing cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in roof kerbs, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
Supply & Fixing in repair 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete with waste coupling and waste pipes of suitable capacity, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Plate racks made out of 1mm thick .Stainless steel, of size 750x600x 250 mm, complete all as specified and directed by Engineer-in-Charge. Make :- SAIL/ JINDAL/ SURAJ
Supply & Fixing 3mm thick Aluminium composite panel cladding plain of approved colour/ shade to beam/ column/ slab in circular/ rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour, with and including aluminium square tubular hollow section 25 x 25 mm not exceeding 900 mm c/c on MS pipe purlin/rafter/column beam/slab to hold ACP cladding etc., complete all as specified and directed by Engineer-in-Charge. (Note:- Colour/ Pattern of ACP sheet shall be as approved by GE).
Material & Labour for providing and fixing of granules textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kgs per pack) made of 92% silica particles coated with fade resistant pigments, 100% acrylic polymer bonding agent (5 Kgs per pack) with the applied thickness of the coating being between 0.8 mm-1.2mm to be applied on a cured, smooth level plaster without keying as per the shades/combinations approved as per the manufacturers instructions for usages, to be applied by and approved applicator of the manufacturer, as per the directions/supervision of the engineer-in-charge. all complete. The above textured coating should confirm to surface spread of flame class one of BS 476: Part 7: 1971 and pull off strength of the coating to meet JISA 6909 on smooth plastered surface complete all as specified and as manufacturers instructions, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing solid PVC Wall Lining consisting of 5mm thick Plain /preleam colour PVC sheet inclusive of solvent cement and fixing at site on wall as per specifications and drawing, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' E/M ITEMS
Taking down carefully aluminium/copper point wiring (light,fan,socket or power) concealed and casing caping complete including fittings and fixtures such as switches,ceiling roses,pendants,regulators,sockets light fittings and making good the disturbed surfaces of walls/ceiling/floor etc., complete all as specified and directed by Engineer-in-Charge.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces, complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric connections and taking down old unserviceable MCB DBs of any capacity including MCBs, complete all as specified and directed by Engineer-in-Charge.
Taking down Ceiling fan & blades and deposit to E/M store, complete all as specified and directed by Engineer-in-Charge.
Hanging only ceiling fan and connecting up cable from ceiling rose or connector to fan, complete all as specified and directed by Engineer-in-Charge.
Material & labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- Make:- Polycab / Havells / Finolex
One light point controlled by one, one way switch
One fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board.
Material & Labour for Point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge. Make:- Polycab / Havells / Finolex
Material & Labour for Point wiring complete with 4 Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 4 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge. Make:- Polycab / Havells / Finolex
Supply & fixing in replacement modular switch 1 way, 6 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular switch 1 way, 16 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular fan regulator, 120 watt, 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement Buzzer, Ding dong, AC 230Volts single pole, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement Modular Bell push 6A 1 module, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Philips/ Wipro / CG
Supply & fixing in replacement strip LED linea Bright 28 watt with driver, (Dimension 5000x8x.3mm) 500lmns/Mtr, 72 LEDs/Mtr, 05 Mtr Roll, complete all as specified and directed by Engineer-in-Charge. Make:- Philips/ Wipro / CG
Supply & fixing in replacement LED surface downlighter lights fitting 1x 15W, 220V, 105lmns/W, (170x170mm dia) AC decorative box/round type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed by Engineer-in-Charge. Make:- Philips/ Wipro / CG
Supply & fixing in replacement LED ceiling light fitting, 25Watt, 2300lmns including connected with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site, complete all as specified and directed by Engineer-in-Charge. Make:- Philips/ Wipro / CG
Material and labour for sub main wiring with two single core 2 x 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, including taking down old unserviceable wiring, complete all as specified and directed by Engineer-in-Charge. Make:- Polycab / Havells / Finolex Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
Material and labour for sub main wiring with two single core 2 x 6 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 6 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, including taking down old unserviceable wiring, complete all as specified and directed by Engineer-in-Charge. Make:- Polycab / Havells / Finolex Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
Supply & fixing in replacement MCB DB 12 way SPN, (Acrylic door), IP 43 “Weather proof” Concealed/ Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper, complete all as specified and directed by Engineer-in-Charge. Make: Legrand / L&T / Schneider
Supply & fixing in replacement VTPN DB 4 way, (Acrylic door), IP 43- “Weather proof” Concealed/ Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper, complete all as specified and directed by Engineer-in-Charge. Make: Legrand / L&T / Schneider
Supply and fixing in replacement of MCB SPN, 240 volt, 32 Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand/ Havells / ABB .
Supply and fixing in replacement of MCB TPN, 240 volt, 100Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand / L&T / Schneider
Supply and fixing in replacement of MCB TPN, 240 volt, 63Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand / L&T / Schneider
Supply and fixing in replacement of MCB SP, 240 volt, 6 to 32 Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Havells/ ABB
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63Amp current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Havells/ ABB
Supply & Fixing Modular Motor starter 16A capacity, 02 Module with metal flush box, cover plate of required module for ACs, complete all as specified and directed by Engineer-in-Charge. Make : Legrand / ABB/ Schneider
Supply & Fixing Co-axial TV socket, One Module, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing double RJ-11 telephone socket (Jack type) with shutter, One Module, complete all as specified and directed by Engineer-in-Charge.
Supply& Fixing rigid non metallic 25mm dia PVC conduit exclusive of boxes (Junction/terminal) but inclusive of all Tee, bends, elbow reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing junction boxes (1 to 4 way) with cover plates and accessories, complete all as specified and directed by Engineer-in-Charge.
Cutting chases, pinning in, making good to facings where required of brick/stone wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and directed by Engineer-in-Charge.
Material & Labour in replacement for Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, protection pipe 15mm dia light grade up to 7.5 mtr length of earth wire, charcoal dust and salt etc. and connected to earthing test point all as specified or directed and testing, complete all as specified and directed by Engineer-in-Charge.
roxy enterprise
K K Construction Co
RAJ ENTERPRISE
JAY BHARAT METAL SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .