Loading…
Loading…
Tender Value
₹75.7 L
EMD Value
₹1.5 L
Closing Date
4 Sept 2026, 3:00 pm7d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
OS CAPITAL
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
SIMILAR NATURE OF WORK:- 1-Erection of LT or above voltageleveldistribution panels. 2-Errection and commissioning LT orabove voltagel i n e (Overhead or underground) 1.1.1 3.Electrification/Rewiring servicebuildings ,Banglow and Qtrs. 4.Supply and erection of tower light.5.Lightihg of station/administration buildings/circulation area
30 conditions · 14 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. as the case may be. Following documents should be submitted by the tenderer according to nature of firm, otherwise offer will be treated as invalid: -
Following documents should be submitted by the tenderer in case of HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
Following documents should be submitted by the tenderer in case of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
FFollowing documents should be submitted by the tenderer in case of LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet).
Following documents should be submitted by the tenderer in case of Partnership Firm: The tenderer shall clearly specify that the tender is submitted on behalf of a partnership firm. (i) A notarized copy of partnership deed. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. (iv) All other documents in terms of explanatory notes in clause 10 and 18 of tender document
I/We have read and understood the condition of GCC 2022 and will submit all documents as per GCC 2022.
The following documents should be specified for submissionalong with tender
A. List of Personnel, Organization available on hand and proposed to be engaged for the subject work
List of works on hand indicating description of work, contract value,and approximate value of balance work yet to be doneand date of award
The tenderers whether sole proprietor , a limited company ora partnership firm he/they should submit authentic proof in terms of partnership deed, proprietorship documents etc. alongwith the tender. If he/they want to act through agent or individual partners should submit a power of attorney duly stamped and authenticated by Notary Public or by Magistratein favour of specific person whether he/she/they are partners of the firm or any other person specifically authorizing him/her name to submit the tender, sign the agreement ,receive money, witness measurements, sign measurement books ,compromise, settie,relinquish any claims, preferred by firm and also sign No Claim Certificate andrefer all or any disputes arbitration
Mandate Form/Bank details must be uploaded
The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the qualification criteria mentioned in the tender document.
BIDDER SHOULD SUBMIT ESIC REGISTRATION CERTIFICATE
BIDDER SHOULD SUBMIT EPF REGISTRATION
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
The above power of attorney shall be submitted even if such specific person is authorized for above purposes through partnership deed / Memorandum of Understanding / Article of Association or such other document, failing which tender is liable to be rejected
If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender.
After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society / HUF etc. shall be neither asked nor considered, if submitted. Further, no suo moto cognizance of any document available in public domain (i.e., on internet etc.) or in Railway's record/office files etc. will be taken for consideration of the tender, if no such mention is available in tender offer submitted.
Para 6.1 Part-I of GCC shall be read as under:- The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to annexure-V, in case of other than Company/proprietary firm, Annexure-V A shall also be submitted by the each member of partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership etc.as the case may be. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested/digitally signed by which they/he is qualifying the qualification criteria mentioned in the tender document
There should be bond agreement with the Supervisor showing employability with the Firm OR any other document issued by state/Central Government showing supervisors employment with the firm.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Bidders are advised to follow the above eligibility and qualifying criteria and submit documents in proper format toqualify their bid for evaluation of offer. If any of the documents is found missing or not in proper form, their offer will not beconsidered for evaluation and post tendering correspondence will not be made to get any additional paper in support of theirclaim for qualifying and eligibility criteria
Note- Segregation of AC Circuit from other load to be ensured (A) On account 90% payment will be made to contractor against supply, installation,testing and commissioning on production of material inspection certificate receipted challan, joint note with Sr.DEE(G) Authorized supervisor, test certificate of manufactureretc.(b) The number (i.e. maximum/minimum) of on account payment will be decided by the Sr. DEE/G/MGS depending upon the performance of contractor or importance of work.(C) Balance 10% will be released/ paid with the final bill after successful completion, testing & commissioning of the complete awarded/ approved varied workd. In case of AMC 85% quarterly will be made rest 15% payment will be made after successfully completion of three year. Bill passing authority is Sr DEE/G/DDU and Paying authority is SrDFM/ECR/DDU
Contractor is to abide by the provisions of Payment of Wages act & MinimumWages act. In order to ensure the same, an application has been developedand hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractorshall register his firm/company etc. and upload requisite details of labour andtheir payment in this portal. These details shall be available in public domain.The Registration/ updation of Portal shall be done as under: (a)Contractorshall apply for onetime registration of his company/firm etc. in theShramikkalyan portal with requisite details subsequent to issue of Letter ofAcceptance. Engineer shall approve the contractor's registration in the portalwithin 7 days of receipt of such request. (b)Contractor once approved by anyEngineer, can create password with login ID (PAN No.) for subsequent use ofportal for all LoAs issued in his favour. (c)The contractor once registered onthe portal, shall provide details of his Letter of Acceptances (LoA) / ContractAgreements on shramikkalyan portal within 15 days of issue of any LoA forapproval of concerned engineer. Engineer shall update (if required) andapprove the details of LoA filled by contractor within 7 days of receipt of suchrequest. (d)After approval of LoA by Engineer, contractor shall fill the salientdetails of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)Itshall be mandatory upon the contractor to ensure correct and promptuploading of all salient details of engaged contractual labour & paymentsmade thereof after each wage period. While processing payment of any 'OnAccount bill' or 'Final bill' or release of 'Advances' or 'Performance Guarantee /Security deposit', contractor shall submit a certificate to the Engineer orEngineer's representatives that "I have uploaded the correct details of contractlabours engaged in connection with this contract and payments made to themduring the wage period in Railway's Shramikkalyan portal at'www.shramikkalyan.indianrailways.gov.in' till ____Month, ____Year
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway thereunder.
In case of any information submitted by tenderer is found to be false forged or incorrect at any time during process for evaluation of tenders, it shall lead to forfeiture of the tender Earnest Money Deposit besides banning of business for a period of up to two years.
As per GCC Advance correction slip no.05 para 5 (3) ii. The original Bank Guarantee should be delivered to Office of the Sr.DEE(G)/DDU before closing date for submission of bids (i.e. excluding the last date of submission of bids)
Electrical Work:-Provision & integration of telecom assets in existing S&T Service Building at stations along with Stores facility for telecom assets. DDU Division.
DDU-EL-G-P-2026-27-07~ECR
DDU-EL-G-P-2026-27-07
Open
Works - General
6 Months
Chandauli, Uttar Pradesh
₹0
₹1.5 L
12 Aug 2026
12 Aug 2026
21 Aug 2026
152 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 45,07,092.05 | ||
| — | 8000.00 | — | — | ||
| Transportation of above cable from store to site. (supplied by Railway) | — | — | — | 5,920 | |
| — | 2450.00 | — | — | ||
| Wall clamping of cable on wall /bridge through suitable clamp of size 50x6 mm of MS flat or catenary of cable through 4 SWG GI wire with suitable clamps (As per site requrement) | — | — | — | 30,135 | |
| — | 5550.00 | — | — | ||
| Supply of HDPE, Laying and drawing of HT / LT cables manually inside the pipe and proper connection to junction Box as per site requirement in all respect ( Size of cable HT / LT 3 core / 4 core from 50 sq mm to 240 sq. mm ), thickness of HDPE should not be less than 06 mm. HDPE should be Conforming to IS : 14333-1996 or latest , Thickness of Pipe Min. 5.3 mm and max. 5.9 mm ISI Marked, CM / L : 7395589 , Material Grade : PE 100 , Make of Pipe : Asian, Apollo Pipes, Vectus ,UTAKARSH, Delight | — | — | — | 13,19,901 | |
| — | 320.00 | — | — | ||
| Concealed Wiring of Light Point/Fan/Exhaust/ Call Bell point fan point in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire. Make : Polycab, Anchor, Finolex, cpntrolling through flush type 10 Amp. switch to be fitted with frame and Tress plate, Make of switch - ROMA, CONA,Schenieder. | — | — | — | 1,36,092.8 | |
| — | 70.00 | — | — | ||
| Concealed wiring of 6 Amp plug point in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG Copper wire. Make : Polycab, Anchor, Finolex controlling through flush type 10 Amp. switch to be fitted with frame and Tress plate , Make - ROMA, CONA, Schenieder | — | — | — | 21,198.8 | |
| — | 72.00 | — | — | ||
| Supply , fixing, testing and commissioning of 15/5 Amp. 5 in 1 combined switch,socket, fuse units duly ISI Approved as per IS:6538/1971 Make :Anchor,EPP.JJ | — | — | — | 4,817.52 | |
| — | 1000.00 | — | — | ||
| Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 2.5 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells. | — | — | — | 45,230 | |
| — | 1000.00 | — | — | ||
| Concealed wiring of main from main distribution board to sub board in heavy guage PVC conduit pipe as per IS:9537 with PVC multistrand copper conductor of size 2 x 4 sqmm in voltage grade 1100 volt as per IS:694 with ECC of 1/18 SWG copper wire, make of wire: Finolex, Plaza , Polycab,Havells. | — | — | — | 62,350 | |
| — | 600.00 | — | — | ||
| Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 6 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells. | — | — | — | 44,970 | |
| — | 391.00 | — | — | ||
| Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x10 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab . | — | — | — | 30,947.65 | |
| — | 70.00 | — | — | ||
| Supply , fixing, testing and commissioning of LED street light luminaire Wattage - 45 Pressure die cast Aluminium housing with heat resistance toughened glass a n d IP 66 protection. Make - Philips, Havells, Bajaj, , HPL, CG, | — | — | — | 1,52,968.2 | |
| — | 48.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED Street light Luminaires Wattage - 60 , 6500 K pressure Die - Cast Aluminium Housing with heat resistant Toughened Glass and IP 66 protection. Make - Philips, Bajaj, Cromptom, C&S. | — | — | — | 2,69,171.04 | |
| — | 152.00 | — | — | ||
| Supply of LED Batten for surface and pendant applications , Anodized Extructed Aluminium Housing, High transmissitivity diffuser and high Lumen output BCLAB ( BAJAJ) 40 Watt Run length 4 Ft. VIVA LED suitable for surface , wall & Conduit mounting with all acessories. Make- Bajaj, Philips, Surya, Havells, Cromptom. | — | — | — | 92,019.28 | |
| — | 152.00 | — | — | ||
| Fixing of above Batten light fittings with suitable clamps. | — | — | — | 9,158 | |
| — | 38.00 | — | — | ||
| Supply of LED lamp 9 W Make - Philips, , C&S, BAJAJ, cromptom. | — | — | — | 2,820.74 | |
| — | 32.00 | — | — | ||
| Supply, Fixing, Testing and commissioning of wall mounted bracket fan of 400 mm. sweep duly ISI approved complete in all respect. make - Khaitan, Usha, Polar,Bajaj. CG. | — | — | — | 41,403.2 | |
| — | 44.00 | — | — | ||
| Fixing, Testing and commisioning of BLDC Ceiling fan 5 star rated with suitable clamps ensuring the safety of fan. (Ceiling fan supplied by railway) | — | — | — | 1,732.28 | |
| — | 16.00 | — | — | ||
| Fixing of Exhaust fans with suitable clmps ensuring safety of the fan. (Exhaust fan will be supplied by Railway ) | — | — | — | 1,015.52 | |
| — | 70.00 | — | — | ||
| Supply, and erection of Earthing with 50 mm Dia. 3 mtr. Length GI Pipe, B-Class as per IS:3043-1987, Confirming to IS :1239 or latest complete with earth box including connection from earth Electrode to MDB/SDB/Poles with 8 SWG GI Wire. Make of Pipe : TATA, JINDAL Surya,Bhushan with latest Amendment and Technical Specifications. | — | — | — | 2,39,562.4 | |
| — | 10.00 | — | — | ||
| Supply, Fixing, testing and commissioning of 3 way DB with 03 Nos. SP MCB 16 amp. /240 V as per IS 11039/ 83 (Reaffirm 2005 ) -8828 /IEC 898. Make -Siemens, Standard, Havells, Haggers. | — | — | — | 2,808.1 | |
| — | 30.00 | — | — | ||
| Supply,fixing,testing and commissioning of 32 Amp DP main switch make : Anchor, Havelles, Standard. | — | — | — | 1,924.8 | |
| — | 16.00 | — | — | ||
| Supply of 63 Amp DP MCB with steel sheet enclosure.Make - Siemens, L&T, Havells. | — | — | — | 14,108 | |
| — | 16.00 | — | — | ||
| "Fixing, testing and commissioning of DP MCB 63 Amp,240 volt." | — | — | — | 1,122.4 | |
| — | 8.00 | — | — | ||
| "Supply of 4 pole 63 Amp Automatic change over switch. Make-Anchor, Havells, Standard, L&T" | — | — | — | 37,804.88 | |
| — | 8.00 | — | — | ||
| Fixing,testing and commissioning of 4 pole 63 Amp. Change over switch./street light Panel. | — | — | — | 2,809.12 | |
| — | 16.00 | — | — | ||
| Supply, Fixing , testing and commissioning of 4 pole 63 Amp MCCB / 440 V A.C with sheet steel enclosure Make Siemens, Havells, Standard. | — | — | — | 38,420 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of 4 pole 100 Amp MCCB with sheet steel enclosure. Make : siemens, L&T, Havells. | — | — | — | 28,830.6 | |
| — | 8.00 | — | — | ||
| Supply, Fixing , testing and commissioning of MCCB DB for distribution of 3 phase supply 415 volt AC comprising with following : For incoming : 1 ) MCCB 4 pole 100 A - 01 nos, make Siemens cat no. 3 V T 82161 A A - 040 A A Z , OR SIMILAR For Outgoing : 2 ) MCB SP 06 A to 32 AMp - 08 nos, as per site requirement, make: Siemens, L&T, Standard, HPL 3 ) Beta bus plus vertical Bus Bar DBs with MCCB incoming cat No. 8 GB 31571RC Make : Siemens, L&T, Havells, HPL. | — | — | — | 50,370.32 | |
| — | 8.00 | — | — | ||
| "Supply, Fixing, Testing and commissioning of of LT panel board of requisite as per site requirement and thickness 2 mm comprising of following. 1) 4 pole 200 Amp capacity 415 volt AC MCCB - 02 no for Incoming make ABB, GE, Siemen, L&T, Havells, Standard, for outgoing. 2) 4 pole 63 Amp capacity 415 volt AC MCCB - 04 nos. make : ABB, GE, Siemens, L&T, Havells, Standard. 3) MCCB of 32 Amp. cap = 04 nos. complete in all respect i.e. copper busbar of 2300 Amp. Cap. (02 nos.) of appropriate size to fulfill above incoming & Outgoing criterion with Ammeter, Voltmeter, Selector switch etc. of approved & ISI approved make. All equipments will be as per site requirement and site incharge." | — | — | — | 7,58,160.72 | |
| — | 16.00 | — | — | ||
| "Installation ,Fixing,Testing and Commissioning of 2 Tr /1.5Tr split type Air conditioner. (supplied by Rly)" | — | — | — | 11,815.04 | |
| — | 16.00 | — | — | ||
| Supply, Fixing, testing and commissioning of single phase starter with overload protection socket and plug top in plastic enclosure, As per Havells code DHDMCSNO2510525, 25 Amp MCB DBOXX COMBO Make :-North west, Havells.Legrand, Standard | — | — | — | 6,044 | |
| — | 16.00 | — | — | ||
| Supply , fixing , testing and commissioning of Automatic Voltage stabliser of 5 KVA cap. With TDR , input =145 to 280 V AC output =200 to 240 v=/-2 V, cutoff =High/ Low volt, Voltmeter =0-300 V, Make =LOGIC STATE, VENUS, V-Guard, Live- Guard. | — | — | — | 58,994.88 | |
| — | 16.00 | — | — | ||
| Supply and commissioning of wall / floor mounted heavy duty powder coated Bracket with fastener for outdoor unit of split A.C. complete with all related acessories as per technical scope pf work. | — | — | — | 6,561.44 | |
| — | 256.00 | — | — | ||
| Supply , fixing, testing and commissioning of Backlit type Signage board as per RDSO Draft specification No.: RDSO /PE/ SPEC/PS/0086 - 2009 (Rev. 1) Dtd. 03/09/2012 or latest Revision/ Amendment. Board size will be as per site requirement (with GST) | — | — | — | 3,81,726.72 | |
| — | 40.00 | — | — | ||
| "Supply of octagonal pole (Dip Galvanised in single dep average 86 micron) 6 mtrs. Long Top dia 70 mm , Bottom Dia. 135 mm. Sheet thickness 3 mm. in single section with base plate (220 x 220 x 12 mm L x B x H) with 700 mm Long Double Arm Bracket and 04 Nos. 16 mm dia. x 600 mm long (100 mm. thread projectional ), foundation Bolts , complete with smart pack junction Box with 6 A MCB and stud terminals (For mounting inside base plate) and Internal wiring for terminal to fitting with 2 x 2.5 Sq. mm. cable of Reputed make i.e. Polycab , finolex , Havells ,Anchor , Plaza ) Make of pole : Bajaj , Jindal , Utkarsh, BPP.( The octagonal poles are designed for maximum wind speed of 169 Km/hr.)" | — | — | — | 3,23,080 | |
| — | 40.00 | — | — | ||
| "Erection and casting of Foundation for Octagonal Tubular pole with earth excavation with cement , concrete and sand (1 :3 :6) and muffing of Base Foundation as per manufacturers drawing and dimension as required under the suppression of site incharge" | — | — | — | 64,021.6 | |
| — | 16.00 | — | — | ||
| Supply and fixing of Fabrication outdoor type water proof MCCB enclosur, suitable for fixing of MCCB's upto 250 Amp. Cap to be fitted on Tr -D mast for provision of AT supply for Railway essential services. The size of enclosure should be of 28" X 12" X 8" ( H X W X D ) and made of CRCA sheet steel of thickness of 16 SWG consisting of arrangement for proper incoming and outgoing power supply with 2" dia cable gland , fixture for base fixing arrangement on Tr - D mast , Provision of enclosure earthing and rain protected door & auto locking arrangement along with cleaning , finishing and painting with powder coating in approved shade as instructed by the site supervisor/engineer. | — | — | — | 1,06,226.56 | |
| — | 16.00 | — | — | ||
| — | 800.00 | — | — | ||
| — | — | — | 13,216 | ||
| — | 72.00 | — | — | ||
| PCC casting above the digged trench. | — | — | — | 83,854.08 | |
| — | — | — | 30,65,625.61 | ||
| — | 7175.00 | — | — | ||
| Transportation of above cable from store to site. (supplied by Railway) | — | — | — | 5,309.5 | |
| — | 2400.00 | — | — | ||
| Wall clamping of cable on wall /bridge through suitable clamp of size 50x6 mm of MS flat or catenary of cable through 4 SWG GI wire with suitable clamps (As per site requrement) | — | — | — | 29,520 | |
| — | 4775.00 | — | — | ||
| Supply of HDPE, Laying and drawing of HT / LT cables manually inside the pipe and proper connection to junction Box as per site requirement in all respect ( Size of cable HT / LT 3 core / 4 core from 50 sq mm to 240 sq. mm ), thickness of HDPE should not be less than 06 mm. HDPE should be Confirming to IS : 14333 1996 or latest , Thickness of Pipe Min. 5.3 mm and max. 5.9 mm ISI Marked, CM / L : 7395589 , Material Grade : PE 100 , Make of Pipe : Asian, Apollo Pipes, Vectus ,UTAKARSH,Delight | — | — | — | 11,35,590.5 | |
| — | 120.00 | — | — | ||
| Concealed Wiring of Light Point/Fan/Exhaust/ Call Bell point fan point in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG copper wire. Make : Polycab, Anchor, Finolex, cpntrolling through flush type 10 Amp. switch to be fitted with frame and Tress plate, Make of switch - ROMA, CONA,Schenieder. | — | — | — | 51,034.8 | |
| — | 48.00 | — | — | ||
| Concealed wiring of 6 Amp plug point in heavy gauge PVC conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG Copper wire. Make : Polycab, Anchor, Finolex.controlling through flush type 10 Amp. switch to be fitted with frame and Tress plate , Make - ROMA, CONA, Schenieder | — | — | — | 14,536.32 | |
| — | 40.00 | — | — | ||
| Supply , fixing, testing and commissioning of 15/5 Amp. 5 in 1 combined switch,socket, fuse units duly ISI Approved as per IS:6538/1971 Make :Anchor,EPP.JJ | — | — | — | 2,676.4 | |
| — | 1107.00 | — | — | ||
| Concealed Wiring of main from main distribution board to sub board in heavy gauge PVC conduit Pipe as per IS : 9537 with PVC multistrand copper conductor of size 2 x 2.5 sqmm in voltagegrade 1100 volt as per IS: 694 with ECC of 1/18 SWG copper wire, make of wire : Finolex, Plaza, Polycab,Havells. | — | — | — | 50,069.61 | |
| — | 800.00 | — | — | ||
| Concealed wiring of main from main distribution board to sub board in heavy guage PVC conduit pipe as per IS:9537 with PVC multistrand copper conductor of size 2 x 4 sqmm in voltage grade 1100 volt as per IS:694 with ECC of 1/18 SWG copper wire, make of wire: Finolex, Plaza , Polycab,Havells. | — | — | — | 49,880 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
UDINNO.GUIDELINE.pdf
ATTACHMENT
GCC2022UPDATED.pdf
ATTACHMENT
AnnexureVupdated.pdf
ATTACHMENT
Annexure-VA1.pdf
ATTACHMENT
GCC2022ACSNO.080910.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
mandateform.pdf
ATTACHMENT
I_CT_GCC-
ATTACHMENT
NewTenderDument2026_.pdf Tender Document 2026
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
NewTenderDument2026_.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].